7.1 KiB
CLARIDEN: check of the labels, 1 to 11 October
You asked to check the existing labels of 1 October 00:00 to 11 October 00:00 (UTC): keep, correct, remove or add.
In short
The old labels are almost all right: 11 kept, 1 corrected by ten minutes, none removed, 4 added. The curves cannot be trusted during the short "view obstruction" episodes, during the outage of 3 to 5 October and its restart, and on D-303-B from 6 October, which follows the camera tilt. No real movement of the structure is established; the descent of row B on 1 October stays open.
What happened
Short view obstructions (1 Oct morning, 2 Oct evening, 3 Oct 17:40, 6 Oct evening). The recognition error of most targets rises together for one to four hours, and the same group of targets (D-301-C, D-302-B, D-304-B, P-301-B) makes a bump that comes back. The camera housing cools at the same time, and the camera moves a little with it; the correction absorbs that part. Nothing shows on the images. The cause is unknown (likely the tunnel air). The curves are wrong by several times their usual noise during these hours.
Row B goes down on the evening of 1 October. D-306-B, D-304-B and D-303-B go down vertically, with no camera movement and no visible cause. D-303-B comes back to its old level over the next day and night; the two others stay low until the outage. Cause unknown: a real movement of these targets is possible.
Look at the blue curve (D-303-B): it falls with the others on the evening of the 1st, then climbs back alone. The red curve (P-301-B) jumps up on the morning of the 3rd.
P-301-B alone, 3 October. Its vertical curve jumps up around 09:50, stays high until early afternoon, then comes back down by late afternoon. Its own recognition error rises at the same time, and its neighbours do not move. The images show a clean spot. Cause unknown; most likely a change in how this one target is seen, not a movement.
The station stops for almost two days (3 Oct 17:50 to 5 Oct 10:30). No measurements, no images, no station data, with normal power before and after. On restart, the 10:30 image shows a large blurred object right in front of the lens and a worker in the tunnel: work was going on at the camera. The first twenty minutes are disturbed, and at 12:20 something passes in front of the right part of the scene. After the outage, many targets sit at a new level. Likely an intervention during the stop; a real movement is not excluded.
The camera tilts, and D-303-B follows it (6 to 11 October). The camera tilt makes a small step at 13:10 on 6 October and the opposite step at 09:00 on 8 October, and drifts slowly in between and after. The correction absorbs this for almost all targets, but not for D-303-B, and only partly for D-303-C, D-304-C and D-301-C. Their curves copy the tilt. This is confirmed: it is a remainder of the camera movement, not a movement of the structure.
The blue curve (D-303-B) and the red one (the tilt, turned upside down) move together, steps included (grey bands).
P-300-B is rejected at every measurement of the range (an older label, still true).
What to do
- Ask the site what was done at the camera between 3 and 5 October, and whether the camera mount was touched on 6 and 8 October.
- Check how the camera is fixed: its tilt moves in steps and drifts.
- Do not read D-303-B, D-303-C, D-304-C and D-301-C as movements while the tilt moves; the correction does not handle them well.
- Correct the position of P-300-B in the configuration, or check the prism.
- Compare the descent of row B on 1 October with the other measurements of the site.
Not established
- The cause of the view obstructions. A measurement of the tunnel air (temperature, dust) at the camera would settle it.
- Whether row B really went down on 1 October, and whether the new levels after the outage are real. The site's own measurements of these targets would settle it.
- Why P-301-B jumped on 3 October.
Verification
12 old labels checked: 11 kept, 1 corrected, 0 removed, 4 added. 16 labels now cover the range.
- CLARIDEN-4 (view obstruction, 2 Oct evening): start moved from 21:45 to 21:30. The 21:40 measurement is already disturbed and was left out.
- Added (2 Oct 03:40 to 3 Oct 03:00): D-303-B climbs back after its descent of the 1st. CLARIDEN-3 mentioned this return in words but did not cover it; a descent and its return are two labels.
- Added (3 Oct 09:40 to 17:00): P-301-B jumps up alone and comes back. No old label covered it.
- Added (6 Oct 13:00 to 13:30): camera tilt step; D-303-B keeps a step down. No old label covered it.
- Added (8 Oct 08:50 to 09:10): the opposite camera tilt step; D-303-B keeps a step up. No old label covered it.
The long labels crossing the range:
- CLARIDEN-1 (P-300-B always rejected): right within the range.
- CLARIDEN-14 (slow drift, 6 to 11 Oct): its dates and family hold, but its text is wrong. It says "no camera movement", yet the camera tilt drifts over the same days and the drifting targets follow it closely. It is a remainder of the camera tilt, not a movement of the targets. Its text should be corrected when its own range is checked.
Labels
| Start (UTC) | End (UTC) | Family | Targets | In a few words |
|---|---|---|---|---|
| 2026-10-01 06:15 | 2026-10-01 08:45 | Visibility | D-301-C, D-302-B, PR_BG, D-306-B, D-303-B, P-301-B, row A | View obstruction, curves bump and come back |
| 2026-10-01 17:45 | 2026-10-02 02:30 | Displacement | D-306-B, D-304-B, D-303-B | Row B goes down, cause unknown |
| 2026-10-02 03:40 | 2026-10-03 03:00 | Displacement | D-303-B | Returns to its level from before the descent |
| 2026-10-02 21:30 | 2026-10-02 23:00 | Visibility | D-304-B, D-301-C, D-302-B, PR_BG, P-301-B, D-304-C | View obstruction, curves bump and come back |
| 2026-10-02 21:50 | 2026-10-02 23:20 | Thermal displacement | camera | Housing cools, camera moves, well corrected |
| 2026-10-03 07:40 | 2026-10-03 08:00 | No data | all | One measurement missing |
| 2026-10-03 09:40 | 2026-10-03 17:00 | Displacement | P-301-B | Jumps up alone, then comes back |
| 2026-10-03 17:30 | 2026-10-03 17:45 | Visibility | D-301-C, D-302-B, PR_BG, D-304-B, D-304-C, P-301-B | Last point before the outage, disturbed |
| 2026-10-03 17:45 | 2026-10-05 10:30 | No data | all | Station stopped for almost two days |
| 2026-10-03 17:45 | 2026-10-05 10:45 | Displacement | many | New levels after the outage |
| 2026-10-05 10:30 | 2026-10-05 11:20 | Obstruction | whole scene | Object at the lens, work at the camera |
| 2026-10-05 12:10 | 2026-10-05 12:30 | Obstruction | row C, D-302-C | Something passes in front, one point |
| 2026-10-06 13:00 | 2026-10-06 13:30 | Displacement | D-303-B | Camera tilt step, D-303-B keeps a step down |
| 2026-10-06 18:00 | 2026-10-06 22:10 | Visibility | D-301-C, D-302-B, PR_BG, D-304-B | View obstruction for four hours |
| 2026-10-06 18:40 | 2026-10-06 22:40 | Thermal displacement | camera | Housing cools, camera moves, well corrected |
| 2026-10-08 08:50 | 2026-10-08 09:10 | Displacement | D-303-B | Opposite tilt step, D-303-B keeps a step up |