FLORIDA: check of the labels from 11 to 22 October

You asked me to check the 23 existing labels of this range.

In short

All 23 labels hold. I added 5 short labels. On the night of the 11th to the 12th, and once on the evening of the 12th, a reference was measured wrongly and made Sellette 4 and Sellette 5 jump for one measurement each time. No real movement of the structure is seen.

Verification

Kept 23, corrected 0, removed 0, added 5.

  • Added: 12/10 00:30–01:00, 01:45–03:00, 03:45–04:30, 06:15–06:45, 22:15–22:45. The reference p1_r is measured at a slightly wrong position, and the targets jump with it.
  • FLORIDA-41: kept, but its start (10:45) may be late. The camera already seems to move from about 08:00, before the gap in the data. This is still to be checked.
  • Spanning labels FLORIDA-1 and FLORIDA-14: nothing wrong seen within the range.

What happened

On the night of the 11th to the 12th, the reference p1_r was measured slightly off at single measurements: at 00:45, 02:00, 02:45, 04:00 and 06:30, then at 22:30 on the 12th. Each time, the corrected curves of Sellette 4 and Sellette 5 jump clearly and come back at the next measurement. The targets themselves do not move in the image. On the camera images, a small bright point next to p1_r is there at the hours without a jump and missing at the hours with one. The cause is likely, but what this point is remains unknown.

p1_r thumbnails Look at the small point at the upper left of p1_r: present at 01:00 and 03:00, absent at 02:00 and 04:00, the hours of the jumps.

What to do

Nothing on site for now. If these jumps come back, look near the reference p1_r for a light or reflection.

Not established

  • What the small point next to p1_r is.
  • The exact start of the thermal cycle on the 19th (FLORIDA-41).
  • FLORIDA-30 was not re-checked in detail.
  • The other stations were not re-read for the No data labels.

Labels

Start (UTC) End (UTC) Family Targets In a few words
12/10 00:30 12/10 01:00 Obstruction p1_r, Sellette 4, Sellette 5 reference measured off for one point
12/10 01:45 12/10 03:00 Obstruction same two such jumps
12/10 03:45 12/10 04:30 Obstruction same one jump
12/10 06:15 12/10 06:45 Obstruction same one jump
12/10 22:15 12/10 22:45 Obstruction same one jump