Files
aimsight-labeling/auto/analyses/NORDEND_2026-08-23T0515_2026-09-04T0615/analysis.md
T

19 KiB
Raw Blame History

Labels: NORDEND, 2026-08-23T05:15Z → 2026-09-04T06:15Z (UTC)

Request: verify the 37 existing labels of the range (work/existing.jsonl, all reviewed by the user on 2026-11-17), keep / correct / remove, and add what they miss. DETECTORS: no. Result: 32 kept, 5 corrected (one of them split in two), 0 removed, 4 added; 42 labels in labels.jsonl.

Context read first:

  • Weather: no data/NORDEND/weather/ folder: no MeteoSwiss weather for this station (no Swiss position). The images are the only witness of the weather.
  • Image quality: none (old camera, quality.py: "No quality metrics"); the occultations are read on error_value, the rejections and the images.
  • Housing temperature: 26.5 °C (24/08 05:00) to 46.9 °C (27/08 12:00); pan r = −0.98, scale r = +0.97, tilt r = +0.74 against it over the range (metrics.py, hourly): the daily camera cycle is thermal. BusVoltage 13.7 to 14.3 V all along: no energy problem.
  • Inventory: 1133 instants, 15 min; 7 gaps (1, 1, 1, 16, 1, 2, 2 missing steps); one instant with 0 retained references (28/08 12:45, CTR04 rejected, CTR02 and CTR03 with empty inlier); PR04 rejected 141 times (spanning Target issue NORDEND-24), PR07 135, CTR01 55, everything else 9 or fewer (work/inventory.txt).
  • Method of the check: scripts/scan.py lists, at each instant, the targets whose corr_x/corr_y leave a rolling median (±4 measurements, self excluded) by more than 5 (then 4) own noises, the rejected sensors, and the non-thermal existing labels that cover the instant (work/scan.txt); every edge of a short label was then read on summary.py at 15 min; the thermal cycles on the pose at 15 min (morning turning points) and scripts/thermal_days.py (targets that dip each day); the images with thumbnails.py (work/img/).

Verdict per old label

Old id Verdict Evidence
NORDEND-51 kept pose cycle pan 0.039°, tilt 0.058°; corr_x PR18 −0.12, PR16, PR15, PR14/PR17 dip at 07h, PR18 corr_y up; start at the range edge
NORDEND-52 kept turning point 05:15 (tilt leaves −0.132 at 05:15, pan at 05:30); PR18, PR16, PR15, PR14 dip (PR17 as much as PR14), PR18 corr_y up
NORDEND-53 kept PR07 rejected 24/08 11:15 → 25/08 12:15; 22:00 thumbnail: pale blurred band over PR07, weak spot by day (10:00, 14:00, 09:00)
NORDEND-54 kept 25/08 01:30 missing for all; image 01:30 exists, last_sync at 01:30, voltage normal; no other station has data that day
NORDEND-55 kept turning point 05:15; PR18, PR16, PR15, PR17 dip
NORDEND-56 kept turning point 06:00; PR18 and PR15 dip (PR16 as much as PR15, not named: incomplete, not wrong)
NORDEND-57 kept PR07 rejected from 07:15, CTR01 until 09:45, PR16, PR09; jumps of PR08, PR13, PR11, PR06, PR16 at 08:00-08:30; CTR01 still off on corr_y at 10:15 → end 10:30 right
NORDEND-58 kept 27/08 01:30 missing, no image, no sync at 01:30 (syncs 01:00, 01:15, 01:45)
NORDEND-59 corrected end 06:15 → 07:00: the next morning's turning point is 07:00 (section 1)
NORDEND-60 corrected end 12:00 → 07:45 (last measurement before the gap); description: the drops come right after the spider, then PR08 again around midnight
NORDEND-61 kept 21:15 image: the spider's lit body bottom right, spots faded; 13 targets rejected at 21:15, 10 at 21:30; PR09 rejected again at 21:45, but the 21:45 image shows no spider and the cobweb (NORDEND-60) explains it
NORDEND-62 kept 28/08 01:45 missing, no image, no sync at 01:45
NORDEND-63 corrected start 06:15 → 07:00 (section 1)
NORDEND-64 kept 28/08 08:00 → 11:45 missing (16 steps), no image; metrics hourly all along, voltage 14.1-14.3 V
NORDEND-65 kept 12:45: CTR04 rejected, 0 retained references (CTR02, CTR03 inlier empty), 14 targets jump up to 65 noises; PR06, PR08, PR15, PR16, PR18 rejected; back at 13:00
NORDEND-66 kept CTR01 rejected 14:30; at the same measurement the error_value of all the sensors rises and PR18, PR17, PR09 move a little on corr_x (not described: incomplete, not wrong)
NORDEND-67 kept rejections 16:00-16:15 of PR09, PR11, PR12, PR14, PR15, PR16, PR07; PR15 corr_y −0.048 at 17:00, −0.026 at 17:15 (halfway), −0.013 at 17:30 → end 17:30 right
NORDEND-68 kept turning point 06:00; PR18, PR16, PR15, PR14 dip, PR18 corr_y up
NORDEND-69 kept PR07 rejected 16:30-16:45, PR07 corr_x jumps until 18:45 → end 19:00 right
NORDEND-70 kept PR07 rejected 22:30; PR16, PR15 jump 22:30-23:00
NORDEND-71 kept PR07, PR09, PR11, PR12, PR14 rejected 00:30-00:45; PR14 corr_x +21 noises at 00:45, PR12 corr_y +11 at 01:00, back 01:15
NORDEND-72 kept turning point 05:45-06:00 by pan and tilt, 06:15 within one or two steps of a gradual onset; PR14, PR15 dip a little, PR18 corr_y up
NORDEND-73 kept PR07 rejected 00:00; PR16 corr_y −22 noises, PR08, PR15 at 00:00, PR14 at 00:15
NORDEND-74 kept turning point 07:00; PR18, PR14 dip a little
NORDEND-75 kept PR07 rejected 12:45-13:15; PR14 corr_x −21 noises at 13:00, 15 sensors at 13:15; back 13:30
NORDEND-76 corrected (split) CTR01 rejected at 14:45 and at 16:00 only, four clean measurements between (15:15 thumbnail: rock less lit) → two labels
NORDEND-77 kept 01/09 01:00 missing, no image; JUNGFRAU has the same gap (00:45 → 01:15). WILDSTRUBEL measures at that minute (not mentioned; the label's "possible" stays right)
NORDEND-78 kept turning point 06:45; PR18, PR16 dip a little, PR18 corr_y up
NORDEND-79 kept CTR01 rejected 15:00-15:15
NORDEND-80 kept pan step 0.006° at 15:45 (among the largest daytime steps of the range); 11 targets off by 4-8 noises at 15:45 only
NORDEND-81 kept turning point 05:45-06:00; PR18, PR16, PR17, PR15 dip
NORDEND-82 kept 03/09 01:30, 01:45 missing, no image, syncs 01:00, 01:15 only; JUNGFRAU same minutes (WILDSTRUBEL measures)
NORDEND-83 kept turning point 06:30; PR15 dips a little; ends at the range end
NORDEND-84 corrected end 13:45 → 14:00: at 13:45 PR18 corr_x +0.04 (+7 noises) and PR07 below its level; back at 14:00
NORDEND-85 kept PR07 error_value up, PR14 +13, PR18 +11, PR07 +9 noises on corr_x at 16:45, back 17:00
NORDEND-86 kept PR07 rejected 23:00-23:30; PR16 corr_x +0.10 at 23:00, PR15 down to 00:15; 22:45 and 00:30 already back (PR14 0.112, PR15 0.134)
NORDEND-87 kept 04/09 01:15, 01:30 missing, no image, syncs 01:00 and 01:45; JUNGFRAU same minutes (WILDSTRUBEL measures)

Spanning NORDEND-24 (PR04, Target issue, 17/08 → 01/10): holds within the range: PR04 rejected 50 times in a row on 23/08 and most of 24-25/08, its corr noise 0.012 (twice that of its neighbours). Its "rejected almost every day" is less true here: no rejection of its own on 26/08, 29/08, 01/09 and 02/09 (only shared ones on 27/08 21:15 and 28/08 13:00). Not wrong enough to call for a change.

1. My labels

Only the changed and the new labels are detailed; the kept ones are in the table above.

2026-08-27T05:45Z → 2026-08-28T07:00Z (NORDEND-59, end corrected)

  • Phenomenon of the catalogue: The camera moves through a thermal effect
  • Precedents: NORDEND-41 (a cycle whose morning falls in a gap) for the reading of 28/08
  • Family: Thermal displacement, unchanged
  • Measured: 28/08, pan −0.0013 to −0.0019° from 03:00 to 06:15, then −0.0022 (06:30), −0.0024 (06:45), −0.0030 (07:00), −0.0046 (07:45); tilt −0.1129 to −0.1152° all night, one point at −0.1110 at 06:30 then back to −0.1146 at 06:45, −0.1126 at 07:00, out at 07:15 (−0.1075). The later of the two axes leaves at 07:15: the cycle of 27/08 ends, and that of 28/08 starts, at 07:00; 06:15 was three steps early.
  • Images: none needed (pose)
  • Confidence: medium: a weak morning, and the gap at 08:00 hides the fast part.

2026-08-28T07:00Z → 2026-08-29T06:00Z (NORDEND-63, start corrected)

  • Same reading as above; the rest of the label holds (weak cycle, the jump at 12:45 and the afternoon disturbances labelled apart).

2026-08-27T19:30Z → 2026-08-28T07:45Z (NORDEND-60, end and description corrected)

  • Phenomenon of the catalogue: A spider web in front of the lens (Visibility when it veils the image)
  • Precedents: none useful beyond the label itself
  • Family: Visibility, unchanged (the web veils the bottom right of the scene, several targets)
  • Measured: CTR01 and PR07 rejected almost every measurement from 21:00 to 07:45 (PR07 from 19:45); after the spider, corr_x of PR08 −0.106 (21:45), PR03, PR06, PR16, PR15, PR05 down at 21:45-22:15, back at 22:30; PR08 down again from 23:00 to 01:00 (−0.004 at 01:00 against about 0.05), back by 02:00. The old end, 12:00, ran over the four-hour gap (NORDEND-64): the last touched measurement before the gap is 07:45, and at 12:00 neither CTR01 nor PR07 is rejected any more (labelling rules, 2: at the edge of a gap, the last measurement before). The old description put the drops "a few hours after the spider's passage": they come right after it, and only PR08 drops again around midnight.
  • Images: 21:00, 21:45, 22:15, 22:30: wide blurred pale bands across the bottom of the scene, over the targets at the bottom right; 05:00 the same; 07:45 (day) still a faint pale band
  • Confidence: high

2026-08-31T14:30Z → 15:00Z and 15:45Z → 16:15Z (NORDEND-76, split)

  • Phenomenon of the catalogue: The sun in the field or behind a spot
  • Precedents: NORDEND-66, NORDEND-79 (the same CTR01 on sunny afternoons); JUNGFRAU-45/55 (a lit background behind a spot)
  • Family: Visibility, unchanged
  • Measured: CTR01 rejected at 14:45 and at 16:00 only; at 15:00, 15:15, 15:30, 15:45 it is measured and nothing deviates (scan at 4 noises). An intermittent episode is cut at a pause of several measurements, and the isolated rejections of a target each have their label (labelling rules, 1 and 3).
  • Images: CTR01 at 14:30, 14:45, 15:15, 16:00: the rock behind it in full sun at 14:45 and at 16:00, less lit at 15:15
  • Confidence: high

2026-09-03T13:15Z → 14:00Z (NORDEND-84, end corrected)

  • Phenomenon of the catalogue: A faint spot lost when the light is missing
  • Precedents: NORDEND-85, NORDEND-75 (PR07 the same days)
  • Family: Visibility, unchanged (consistency with the other PR07 moments of the station)
  • Measured: 13:30 PR07 rejected, PR15 corr_x +0.05, PR16, PR12, PR01 corr_y up; 13:45 PR18 corr_x 0.260 against 0.22 (+7 noises), PR07 0.046 against 0.07; 14:00 all back. A measurement still touched at 13:45: the end is 14:00.
  • Images: the 13:30 thumbnail already cited (weak PR07)
  • Confidence: high on the bounds

2026-08-28T12:00Z → 12:30Z (added)

  • Phenomenon of the catalogue: none exactly (closest: visibility drops over the whole scene, without an obstacle, but brief)
  • Precedents: NORDEND-65 (the next measurement, same signature with CTR04 lost); NORDEND-173 (error up on almost all sensors)
  • Family: Visibility: the whole scene degraded (error_value up on every sensor together), no object, no camera step; same family as NORDEND-65
  • Measured: error_value of all the sensors about three times higher at 12:00 and 12:15 (CTR04 0.20, 0.24; targets 0.15-0.21; 0.04-0.07 at 12:30), no rejection; corr_x at 12:15: PR03 0.045 (0.028 around), PR09 +0.03, PR12 +0.025, PR11 +0.02, PR01, PR10 corr_y down (7 targets at 5-6 noises); 12:00 already PR03 −0.02, PR17 corr_y −7 noises; 12:30 back. 12:00 is the first measurement after the gap: the event starts there (labelling rules, 2). 12:30 is clean, hence a label apart from NORDEND-65.
  • Images: zone of the targets at 12:00, 12:15, 12:30, 12:45: quarry in the sun, nothing in front, no visible difference at that scale
  • Confidence: medium (the cause is not seen)

2026-08-29T11:45Z → 12:15Z (added)

  • Phenomenon of the catalogue: A step of the camera that the compensation does not erase
  • Precedents: NORDEND-80 (same station, same signature, reviewed); LENZSPITZE-84 (a one-measurement jolt of the camera during the thermal day, Displacement); SNCF01-42
  • Family: Displacement, like NORDEND-80: a camera step with a remainder, cause not established
  • Measured: pan −0.0090 → −0.0003 → −0.0033°, rotation −0.0127 → −0.0031 → −0.0090° (a pan step of 0.0087°, the 4th largest daytime pan step of the range; median night step 0.0005°); rigid fit from 11:30: translation 0.37, −0.39 px at 12:00, still 0.28, −0.33 px at 12:15 (the camera keeps most of it); residuals PR15 +0.032, PR16 +0.030 px, CTR04 −0.025 px at 12:00 only; corr_x PR15 0.168 (0.12 around), PR16 0.170 (0.12-0.13), PR14 +0.015; error_value at its level, no rejection.
  • Images: PR15, PR16, CTR04 at 11:45, 12:00, 12:15 (fixed frame): spots intact, nothing in front; background darker at 12:00
  • Confidence: medium

2026-08-31T11:30Z → 12:00Z (added)

  • Phenomenon of the catalogue: none exactly (closest: the base changes without a reference lost)
  • Precedents: JUNGFRAU-45/55/72 (group jumps of one measurement when a reference shifts, there with the sun behind it); none of this exact shape at NORDEND
  • Family: Displacement: a jump then the return without an established cause; no nuisance seen that would make it Visibility
  • Measured: corr_x PR05 0.072 → 0.009 → 0.072 (−13 noises), PR08 0.052 → 0.015 → 0.046, PR12 0.059 → 0.025 → 0.060; error_value lower, not higher (CTR04 0.025 against 0.064); all three references retained; rigid residuals at 11:45: PR05 −0.045 px, CTR04 +0.036 px, median of the targets 0.015. Pose agitated (rotation −0.0189° at 11:30, −0.0109° at 11:45).
  • Images: PR05, PR08, PR12, PR06, CTR04, CTR02 at 11:30, 11:45, 12:00: spots intact; image background 23 → 5 grey levels from 11:30 to 11:45 (whole scene darker)
  • Confidence: medium (a real but small, one-measurement event; cause open)

2026-09-03T08:45Z → 09:15Z (added)

  • Phenomenon of the catalogue: A faint spot lost when the light is missing (here kept, not rejected)
  • Precedents: NORDEND-85 (PR07, error up for one measurement without rejection, Visibility)
  • Family: Visibility, consistent with the other PR07 moments
  • Measured: PR07 error_value 0.194 (0.06-0.07 around, threshold 0.4), corr_y 0.141 against 0.087-0.091, back at 09:15; PR06 and PR08 unchanged; pose without step.
  • Images: PR07, PR06 at 08:45, 09:00, 09:15 (fixed frame): PR07's spot dimmer at 09:00, nothing in front
  • Confidence: high on the event, cause not established

2. What I left without a label

  • Morning agitation of the thermal cycles (23/08 08:30, 24/08 08:00-09:00, 25/08 08:15-09:30, 30/08 09:00, 01/09 08:15-08:30, 02/09 08:30-09:45): 3-9 targets at 5-9 noises during the fast morning movement of the camera (tilt steps up to 0.026° by day against 0.0007° at night): the remainder of the compensation, described in the thermal labels ("the compensation does not erase everything").
  • Afternoon jumps under the pose agitation (23/08 15:15 and 15:45, 24/08 15:15 and 15:45 with PR01 corr_y +0.05 and PR14 corr_x +0.04, 26/08 14:45 and 16:15): 2-5 targets at 4-9 noises, the pose stepping (tilt −0.107 → −0.115° at 24/08 15:45), error_value not rising: the agitation of the thermal day, which goes into the thermal label (labelling rules, 5), not a Visibility. The 24/08 ones fall under NORDEND-53, whose subject is PR07 alone.
  • Whole-scene error_value rises with nothing on the curves: 27/08 10:45, 11:45, 19:30; 28/08 13:30; 29/08 07:45, 10:00; 30/08 10:30; 31/08 08:45, 09:00, 11:00, 12:00, 14:00, 14:30, 15:15, 16:15, 16:30; 01/09 11:15 (14-21 sensors above 5 MAD): no target leaves its level at 5 noises at these instants; an error_value without effect on the curves is not labelled.
  • References alone at 5-8 noises (23/08 08:30, 24/08 14:45 and 17:00, 27/08 10:45 and 14:30, 02/09 14:00, 03/09 14:15): their corr only, the targets do not follow.
  • CTR04 and PR05, PR08, PR15 error_value raised all night 24-25/08 without effect on their corr (the thread of NORDEND-53 nearby).

3. The documentation

  • labeling-rules.md, section 2, settled the three bound corrections: the camera cycle starts at the later of tilt and pan (28/08), at the edge of a gap the bound is the last measurement before (NORDEND-60), a measurement still halfway is touched (NORDEND-84; it also confirmed NORDEND-67 and NORDEND-57 as right). Sections 1 and 3 (isolated rejections, an intermittent episode cut at a pause of several measurements) settled the split of NORDEND-76.
  • families.md, "A jump then the return ... without an established cause: Displacement", for the 31/08 group jump. The station's own brief PR07 labels (NORDEND-75, 84, 85) are Visibility with "cause not established": I followed them for PR07 (same target, same family), but the boundary text would rather say Displacement for a jump without a seen nuisance; a line in families.md on a weak target that flickers in daylight (Visibility, "A faint spot lost when the light is missing", even without rejection) would remove the doubt.
  • Missing: the catalogue has no entry for a whole-scene error_value rise of one or two measurements by day, without an obstacle (28/08 12:00-12:45, and the many instants left without a label when the curves stay still). Its cause (exposure, sun, a less sharp image) is not established here.
  • labeling-rules.md, 3 (a target rejected alone just after a passage is the same event) would extend NORDEND-61 to 22:00 for PR09 at 21:45; the 21:45 image shows the web and no spider, and the web is labelled over that measurement: kept as is.
  • The No data labels NORDEND-77, 82, 87 cite JUNGFRAU only; WILDSTRUBEL has measurements at those minutes. The rule ("with two stations only, the common cause is possible") still fits; saying that a third station measures would be more complete.
  • Precedents: NORDEND-80 and LENZSPITZE-84 fixed the family and conclusion of the 29/08 camera step; the JUNGFRAU REF_G series pointed to the reference residual for 31/08.

Difficulties

  • No weather for NORDEND (no weather/ folder), no image quality (old camera): the causes rest on the images alone.
  • My scan (scripts/scan.py) first printed false gaps (the export times carry seconds); fixed by rounding to the minute.

Sources read

  • agents/agents/analyst.md, instructions/analyst.md, the request (work/prompt.txt, request.json), work/existing.jsonl, work/spanning.jsonl
  • tools/GUIDE.md, tools/DATA.md, labeling/families.md, labeling/labeling-rules.md, labeling/reading-rules.md, labeling/stations.md (in full)
  • tools/scripts/data.py (the loader, for my scripts)
  • Tools: inventory.py, overview.py (range; 27-28/08; --rigid on 29/08 and 31/08), ranges.py --rolling 4 --instants 3, summary.py (15 min tables), metrics.py, stations.py (NORDEND, JUNGFRAU, WILDSTRUBEL), quality.py (no metrics), thumbnails.py, plot.py, gif.py, precedents.py (4 queries)
  • Raw: metrics/ last_sync on the gap nights, the images listing around each gap
  • My scripts: scripts/scan.py, scripts/thermal_days.py; outputs in work/