43 lines
26 KiB
JSON
43 lines
26 KiB
JSON
{"start": "2026-08-23T05:15Z", "end": "2026-08-24T05:15Z", "family": "Thermal displacement", "description": "Thermal cycle of the camera, poorly compensated. In the morning, when the housing heats up strongly, the camera turns all at once (tilt rising, pan dropping, scale changing); the raw positions of all the targets and references move together. The compensation does not erase everything: the corr_x of PR18, PR16, PR15 and PR17 drops strongly, the corr_y of PR18 rises, then the curves come back in the afternoon; the camera then comes back slowly, in the evening and all night (the pan rises again), until the start of the next morning. Cold night following, like the previous one: the registration error rises and PR10 departs a little on corr_y at the trough of the housing temperature. Deduced cause: the pose follows the housing temperature, and the rock face of the quarry cannot move with the temperature. This is not a movement of the structure: nothing to do.", "review": "2026-11-17"}
|
|
{"start": "2026-08-24T05:15Z", "end": "2026-08-25T05:15Z", "family": "Thermal displacement", "description": "Thermal cycle of the camera, poorly compensated. In the morning, when the housing heats up strongly, the camera turns gradually (tilt rising, pan dropping, scale changing); the raw positions of all the targets and references move together. The compensation does not erase everything: the corr_x of PR18, PR16, PR15 and PR14 drops strongly, the corr_y of PR18 rises, then the curves come back in the afternoon; the camera then comes back slowly, in the evening and all night (the pan rises again), until the start of the next morning. The reference CTR04 also departs a little from the overall movement at the height of the morning. Deduced cause: the pose follows the housing temperature, and the rock face of the quarry cannot move with the temperature. This is not a movement of the structure: nothing to do.", "review": "2026-11-17"}
|
|
{"start": "2026-08-24T11:00Z", "end": "2026-08-25T12:30Z", "family": "Obstruction", "description": "PR07 alone is rejected almost without interruption from late morning to the next midday: its curve is missing. At night, a pale blurred band (lit cobweb thread) covers its spot (22:00 thumbnail); by day, its spot stays weak and the thread cannot be seen (14:00, 09:00). Its neighbours remain measured. Cause seen on the 22:00 thumbnail: the thread in front of the target. Ignore PR07's curve over the range.", "review": "2026-11-17"}
|
|
{"start": "2026-08-25T01:15Z", "end": "2026-08-25T01:45Z", "family": "No data", "description": "One measurement is missing for all the sensors, at night: all the curves have a gap. The image of that instant exists, the station synchronised at that instant (last_sync) and its voltage is normal: the station is running, the measurement of that instant is missing from the data. No other station has data on that date to compare; cause not established. A gap of one or two measurements comes back around the same hour on many nights of the range. The curves resume at the next measurement: nothing to do.", "review": "2026-11-17"}
|
|
{"start": "2026-08-25T05:15Z", "end": "2026-08-26T06:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the camera, poorly compensated. In the morning, when the housing heats up, the camera turns all at once (tilt rising, pan dropping, scale changing); the raw positions of all the targets and references move together. The compensation does not erase everything: the corr_x of PR18, PR16, PR15 and PR17 drops markedly, the corr_y of PR18 rises, then the curves come back in the afternoon; the camera then comes back slowly, in the evening, then only very little at night, until the start of the next morning. Deduced cause: the pose follows the housing temperature, and the rock face of the quarry cannot move with the temperature. This is not a movement of the structure: nothing to do.", "review": "2026-11-17"}
|
|
{"start": "2026-08-26T06:00Z", "end": "2026-08-27T05:45Z", "family": "Thermal displacement", "description": "Thermal cycle of the camera, poorly compensated. In the morning, when the housing heats up strongly, the camera turns all at once (tilt rising, pan dropping, scale changing); the raw positions of all the targets and references move together. The compensation does not erase everything: the corr_x of PR18 and PR15 drops markedly, the corr_y of PR18 hardly moves, then the curves come back in the afternoon; the camera then comes back slowly, in the evening and all night (the pan rises again), until the start of the next morning. Deduced cause: the pose follows the housing temperature, and the rock face of the quarry cannot move with the temperature. This is not a movement of the structure: nothing to do.", "review": "2026-11-17"}
|
|
{"start": "2026-08-26T07:00Z", "end": "2026-08-26T10:30Z", "family": "Visibility", "description": "Morning of poor visibility: CTR01 rejected almost all morning, PR07, PR09 and PR16 at times; the corr_x of PR05, PR06, PR08, PR11, PR13, PR14, PR16 jumps for a few measurements, then comes back. On the 08:00 image, a blurred pale band (cobweb thread near the lens) crosses the bottom of the scene in the sun. Cause seen on the 08:00 image: the cobweb, lit by the morning sun. The structure does not move: do not trust the curves over the range.", "review": "2026-11-17"}
|
|
{"start": "2026-08-27T01:15Z", "end": "2026-08-27T01:45Z", "family": "No data", "description": "One measurement is missing for all the sensors, at night: all the curves have a gap. The image is missing too, with no synchronisation at that instant; the voltage is normal around it. No other station has data on that date to compare; cause not established. A gap of one or two measurements comes back around the same hour on many nights of the range. The curves resume at the next measurement: nothing to do.", "review": "2026-11-17"}
|
|
{"start": "2026-08-27T05:45Z", "end": "2026-08-28T07:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the camera, poorly compensated. In the morning, when the housing heats up strongly, the camera turns gradually (tilt rising, pan dropping, scale changing); the raw positions of all the targets and references move together. The compensation does not erase everything: the corr_x of PR18, PR16, PR15 and PR13 drops markedly, the corr_y of PR18 rises, then the curves come back in the afternoon; the camera then comes back slowly, in the evening, then only very little at night, until the start of the next morning. The evening and the night are disturbed by a cobweb and the spider's passage (labelled separately). Deduced cause: the pose follows the housing temperature, and the rock face of the quarry cannot move with the temperature. This is not a movement of the structure: nothing to do."}
|
|
{"start": "2026-08-27T19:30Z", "end": "2026-08-28T07:45Z", "family": "Visibility", "description": "Cobweb night: blurred bands lit by the infrared cross the bottom of the scene, in front of the targets at the bottom right (21:00, 21:45, 22:30 and 05:00 images, still faint on the 07:45 image, by daylight). CTR01 and PR07 are rejected almost all night, until the morning gap. Right after the spider's passage, the corr_x of PR08, PR03, PR06, PR16, PR15 and PR05 drops for a few measurements, then comes back; later, around midnight, that of PR08 drops again for a few hours before coming back. The measurements stop in the morning (gap labelled separately), hence the end of the range. The spider's passage is labelled separately. Cause seen on the images: the cobweb in front of the lens. The structure does not move: do not trust these curves over the range."}
|
|
{"start": "2026-08-27T21:00Z", "end": "2026-08-27T21:45Z", "family": "Obstruction", "description": "The spider passes in front of the lens: on the 21:15 image, its lit body makes a large white spot at the bottom right, the scene darkens and the spots fade out. Almost all the targets are rejected for two measurements in a row, the others jump; the references hold. Everything then comes back, except what the cobweb keeps disturbed (labelled separately). Points to ignore, this is not a movement.", "review": "2026-11-17"}
|
|
{"start": "2026-08-28T01:30Z", "end": "2026-08-28T02:00Z", "family": "No data", "description": "One measurement is missing for all the sensors, at night: all the curves have a gap. The image is missing too, with no synchronisation at that instant; the voltage is normal around it. No other station has data on that date to compare; cause not established. A gap of one or two measurements comes back around the same hour on many nights of the range. The curves resume at the next measurement: nothing to do.", "review": "2026-11-17"}
|
|
{"start": "2026-08-28T07:00Z", "end": "2026-08-29T06:00Z", "family": "Thermal displacement", "description": "Weak thermal cycle of the camera: the housing warms up little and the pose starts slowly before a gap in the morning measurements (labelled separately); the strongest part of the movement happens during the gap. When measurements resume, the pose has moved and comes back in the afternoon, then slowly in the evening and at night, until the start of the next morning; the raw positions of all the targets and references move together, and the corrected curves hardly depart from it. The jump of the basis at 12:45 and the other disturbances of the day are labelled separately. Deduced cause: the pose follows the housing temperature, and the rock face of the quarry cannot move with the temperature. This is not a movement of the structure: nothing to do."}
|
|
{"start": "2026-08-28T07:45Z", "end": "2026-08-28T12:00Z", "family": "No data", "description": "No measurement or image for a few hours in the morning: all the curves are missing. The system metrics and the synchronisations continue and the voltage is normal: the station is powered and communicates, but delivers neither measurement nor image. No other station has data on that date to compare; cause not established. The curves resume without any offset of their own: nothing to do, to be checked if it happens again.", "review": "2026-11-17"}
|
|
{"start": "2026-08-28T12:00Z", "end": "2026-08-28T12:30Z", "family": "Visibility", "description": "At the resumption of the measurements after the morning gap, the error_value of all the sensors, references included, rises together for two measurements, without any rejection, then comes back; at the second, several targets (PR03, PR09, PR11, PR12) jump a little on corr_x, then come back. The 12:00 and 12:15 thumbnails show the quarry in the sun and nothing in front of the targets. Same signature as a measurement later, at 12:45, when the reference CTR04 is lost (labelled separately). Cause not established (an image of the whole scene less sharp). The structure does not move: points to ignore."}
|
|
{"start": "2026-08-28T12:30Z", "end": "2026-08-28T13:00Z", "family": "Visibility", "description": "The reference CTR04 is rejected for one measurement and the compensation runs without it: the basis changes, almost all the targets jump together on corr_x and corr_y; the corrections of the remaining references fall to zero, as the expert reads it on 04/09, then everything comes back at the next measurement. Several targets of the same area are rejected with it. On the thumbnails, the spots of CTR04 and PR08 are stretched in height at that instant, sharp before and after: the image is slightly less sharp, perhaps motion blur (machines are working in the quarry, 12:45 image), cause not established. The jump is not a movement: point to ignore.", "review": "2026-11-17"}
|
|
{"start": "2026-08-28T14:15Z", "end": "2026-08-28T14:45Z", "family": "Visibility", "description": "CTR01 (local reference, treated as a target) is rejected for one measurement in the afternoon: its corr_x and corr_y curves are missing. Seen on the 14:30 thumbnail: the rock around the target is in full sun, as bright as the spot, which drowns in it. The other targets remain measured. The structure does not move: nothing to do, CTR01's curve is missing on sunny afternoons.", "review": "2026-11-17"}
|
|
{"start": "2026-08-28T15:15Z", "end": "2026-08-28T17:30Z", "family": "Visibility", "description": "Afternoon of reduced visibility: the error_value of the three references rises together without getting them rejected, then PR07, PR09, PR11, PR12, PR14, PR15, PR16 are rejected for one or two measurements, and PR07, PR13, PR15, PR16, PR08 jump on corr_x or corr_y until late afternoon. On the 16:15 image, a blurred band (cobweb thread) can be guessed at the bottom of the scene. Cause not established (perhaps the cobweb, by day). The structure does not move: points to ignore.", "review": "2026-11-17"}
|
|
{"start": "2026-08-29T06:00Z", "end": "2026-08-30T06:15Z", "family": "Thermal displacement", "description": "Thermal cycle of the camera, poorly compensated. In the morning, when the housing heats up, the camera turns gradually (tilt rising, pan dropping, scale changing); the raw positions of all the targets and references move together. The compensation does not erase everything: the corr_x of PR18, PR16, PR15 and PR14 drops markedly, the corr_y of PR18 rises, then the curves come back in the afternoon; the camera then comes back slowly, in the evening and all night (the pan rises again), until the start of the next morning. Deduced cause: the pose follows the housing temperature, and the rock face of the quarry cannot move with the temperature. This is not a movement of the structure: nothing to do.", "review": "2026-11-17"}
|
|
{"start": "2026-08-29T11:45Z", "end": "2026-08-29T12:15Z", "family": "Displacement", "description": "For one measurement, the camera makes a small step (pan and rotation: the raw positions of all the sensors shift together) and keeps most of it afterwards; at that measurement the compensation does not quite absorb it: the corr_x of PR15 and PR16, and more weakly of PR14, jumps together, and the reference CTR04 departs a little from the overall movement; everything comes back at the next measurement. The error_value of the sensors stays at its level and no reference is lost; on the 12:00 thumbnails the spots are intact and nothing is in front of them, the scene a little darker than a measurement earlier. Cause not established: this is not a movement of the structure, the camera moved; point to ignore, the camera is to be watched if it happens again."}
|
|
{"start": "2026-08-29T16:00Z", "end": "2026-08-29T19:00Z", "family": "Visibility", "description": "In late afternoon, PR07 is rejected for two measurements and its corr_x curve jumps several times until the evening, PR16 and PR15 a little; the spot of PR07 is very weak on the 16:30 thumbnail, without any obstacle. Weak target, poorly seen at this hour; points to ignore.", "review": "2026-11-17"}
|
|
{"start": "2026-08-29T22:15Z", "end": "2026-08-29T23:30Z", "family": "Visibility", "description": "At night, PR07 is rejected for one measurement and PR15, PR16 jump on corr_x and corr_y; the 22:30 image is very noisy and the spot of PR07 is lost in it. Points to ignore, nothing to do.", "review": "2026-11-17"}
|
|
{"start": "2026-08-30T00:15Z", "end": "2026-08-30T01:15Z", "family": "Visibility", "description": "At night, PR07, PR09, PR11, PR12 and PR14 are rejected for one or two measurements, and PR14, PR15, PR12, PR16 jump on corr_x or corr_y; the 00:45 image is very noisy, with blurred discs in the corners, the spots weak. Points to ignore, nothing to do.", "review": "2026-11-17"}
|
|
{"start": "2026-08-30T06:15Z", "end": "2026-08-31T07:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the camera, poorly compensated. In the morning, when the housing warms up little, the camera turns gradually (tilt rising, pan dropping, scale changing); the raw positions of all the targets and references move together. The compensation does not erase everything: the corr_x of PR15 and PR14 drops a little, the corr_y of PR18 rises, then the curves come back in the afternoon; the camera then comes back slowly, in the evening and all night (the pan rises again), until the start of the next morning. Deduced cause: the pose follows the housing temperature, and the rock face of the quarry cannot move with the temperature. This is not a movement of the structure: nothing to do.", "review": "2026-11-17"}
|
|
{"start": "2026-08-30T23:45Z", "end": "2026-08-31T00:30Z", "family": "Visibility", "description": "At night, PR07 is rejected for one measurement and PR14, PR15, PR16 jump on corr_x or corr_y; on the 00:00 thumbnail, a pale blurred veil (lit cobweb thread) covers PR07 and PR14. Points to ignore, nothing to do.", "review": "2026-11-17"}
|
|
{"start": "2026-08-31T07:00Z", "end": "2026-09-01T06:45Z", "family": "Thermal displacement", "description": "Thermal cycle of the camera, poorly compensated. In the morning, when the housing warms up little, the camera turns gradually (tilt rising, pan dropping, scale changing); the raw positions of all the targets and references move together. The compensation does not erase everything: the corr_x of PR14 and PR18 drops a little, the corr_y of PR18 hardly moves, then the curves come back in the afternoon; the camera then comes back slowly, in the evening, then only very little at night, until the start of the next morning. Deduced cause: the pose follows the housing temperature, and the rock face of the quarry cannot move with the temperature. This is not a movement of the structure: nothing to do.", "review": "2026-11-17"}
|
|
{"start": "2026-08-31T11:30Z", "end": "2026-08-31T12:00Z", "family": "Displacement", "description": "For one measurement, the corr_x of PR05 drops clearly, those of PR08 and PR12 a little, then they come back at the next measurement. The error_value does not rise and no reference is lost; against the overall movement of the targets, PR05 and the reference CTR04 shift a little at that measurement. On the 11:45 thumbnails the spots are intact and nothing is in front of them; the whole scene is darker than a measurement earlier, as if the sun were veiled. Cause not established; the curves come back at once: this is not a movement of the structure, points to ignore."}
|
|
{"start": "2026-08-31T12:30Z", "end": "2026-08-31T13:30Z", "family": "Visibility", "description": "At midday, PR07 is rejected for three measurements in a row and several targets (PR14 above all, PR16, PR05, PR12) jump on corr_x or corr_y; the spot of PR07 is almost invisible on the 13:00 thumbnail, without any obstacle. Disturbance of the view of unestablished cause; points to ignore.", "review": "2026-11-17"}
|
|
{"start": "2026-08-31T14:30Z", "end": "2026-08-31T15:00Z", "family": "Visibility", "description": "CTR01 (local reference, treated as a target) is rejected for one measurement in the afternoon: its corr_x and corr_y curves are missing. Seen on the 14:45 thumbnail: the rock around the target is in full sun, as bright as the spot, which drowns in it. The other targets remain measured. The rejection comes back later the same afternoon (next label). The structure does not move: nothing to do, CTR01's curve is missing on sunny afternoons."}
|
|
{"start": "2026-08-31T15:45Z", "end": "2026-08-31T16:15Z", "family": "Visibility", "description": "CTR01 (local reference, treated as a target) is rejected again for one measurement, later in the same afternoon: its corr_x and corr_y curves are missing. Seen on the 16:00 thumbnail: the rock around the target is again in full sun, as bright as the spot, which drowns in it; in between, on the 15:15 thumbnail, the rock is less lit and CTR01 is measured. The other targets remain measured. The structure does not move: nothing to do, CTR01's curve is missing on sunny afternoons."}
|
|
{"start": "2026-09-01T00:45Z", "end": "2026-09-01T01:15Z", "family": "No data", "description": "One measurement is missing for all the sensors, at night: all the curves have a gap; the image is missing too, the voltage is normal around it. JUNGFRAU has the same gap at the same minutes: a common cause outside the station (transmission or reception of the data) is possible, not a station failure; it is not established. The curves then resume: nothing to do on the station.", "review": "2026-11-17"}
|
|
{"start": "2026-09-01T06:45Z", "end": "2026-09-02T05:45Z", "family": "Thermal displacement", "description": "Thermal cycle of the camera, poorly compensated. In the morning, when the housing heats up, the camera turns all at once (tilt rising, pan dropping, scale changing); the raw positions of all the targets and references move together. The compensation does not erase everything: the corr_x of PR18 and PR16 drops a little, the corr_y of PR18 rises, then the curves come back in the afternoon; the camera then comes back slowly, in the evening and all night (the pan rises again), until the start of the next morning. Deduced cause: the pose follows the housing temperature, and the rock face of the quarry cannot move with the temperature. This is not a movement of the structure: nothing to do.", "review": "2026-11-17"}
|
|
{"start": "2026-09-01T14:45Z", "end": "2026-09-01T15:30Z", "family": "Visibility", "description": "CTR01 (local reference, treated as a target) is rejected for two measurements in a row in the afternoon: its corr_x and corr_y curves are missing. Deduced cause: same hour and same signature as the other sunny afternoons, where the thumbnails show the rock in full sun around the target and the spot drowning in it (16/08, 21 and 22/09). The other targets remain measured. The structure does not move: nothing to do, CTR01's curve is missing on sunny afternoons.", "review": "2026-11-17"}
|
|
{"start": "2026-09-01T15:30Z", "end": "2026-09-01T16:00Z", "family": "Displacement", "description": "For one measurement, the camera pose makes a small step (pan and rotation) then comes back; the compensation does not quite erase it: the corr_x of PR08, PR13, PR18 and, more weakly, of PR01, PR11 and PR17 jumps together and comes back at the next measurement. The error_value of all the sensors stays at its level and no reference is lost; on the 15:45 image, nothing in front of the targets (a machine is parked at the back of the quarry, far from them). Cause not established: this is not a movement of the structure, the camera moved; point to ignore, the camera is to be watched if it happens again.", "review": "2026-11-17"}
|
|
{"start": "2026-09-02T05:45Z", "end": "2026-09-03T06:30Z", "family": "Thermal displacement", "description": "Thermal cycle of the camera, poorly compensated. In the morning, when the housing heats up, the camera turns all at once (tilt rising, pan dropping, scale changing); the raw positions of all the targets and references move together. The compensation does not erase everything: the corr_x of PR18, PR16, PR17 and PR15 drops markedly, the corr_y of PR18 rises, then the curves come back in the afternoon; the camera then comes back slowly, in the evening, then only very little at night, until the start of the next morning. Deduced cause: the pose follows the housing temperature, and the rock face of the quarry cannot move with the temperature. This is not a movement of the structure: nothing to do.", "review": "2026-11-17"}
|
|
{"start": "2026-09-03T01:15Z", "end": "2026-09-03T02:00Z", "family": "No data", "description": "Two measurements in a row are missing for all the sensors, at night: all the curves have a gap; the images are missing too, the voltage is normal around it. JUNGFRAU has the same gap at the same minutes: a common cause outside the station (transmission or reception of the data) is possible, not a station failure; it is not established. The curves then resume: nothing to do on the station.", "review": "2026-11-17"}
|
|
{"start": "2026-09-03T06:30Z", "end": "2026-09-04T06:15Z", "family": "Thermal displacement", "description": "Thermal cycle of the camera, poorly compensated. In the morning, when the housing warms up little, the camera turns gradually (tilt rising, pan dropping, scale changing); the raw positions of all the targets and references move together. The compensation does not erase everything: the corr_x of PR15 drops a little, the corr_y of PR18 hardly moves, then the curves come back in the afternoon; the camera then comes back slowly, in the evening, then only very little at night, until the start of the next morning. At night, a cobweb thread passes over a few targets (labelled separately). Deduced cause: the pose follows the housing temperature, and the rock face of the quarry cannot move with the temperature. This is not a movement of the structure: nothing to do.", "review": "2026-11-17"}
|
|
{"start": "2026-09-03T08:45Z", "end": "2026-09-03T09:15Z", "family": "Visibility", "description": "The error_value of PR07 rises at once for one measurement, without rejection, and its corr_y jumps, then comes back at the next measurement; on the 09:00 thumbnail its spot is dimmer, nothing in front of it, while its neighbour PR06 does not change. Weak target, poorly seen at that instant; cause not established. Point to ignore, nothing to do."}
|
|
{"start": "2026-09-03T13:15Z", "end": "2026-09-03T14:00Z", "family": "Visibility", "description": "PR07 is rejected for one measurement and PR15, PR16, PR12, PR01 jump together on corr_x or corr_y; at the next measurement, PR18 jumps on corr_x and PR07 comes back below its level, then everything comes back. The spot of PR07 is very weak on the 13:30 thumbnail. Cause not established; points to ignore."}
|
|
{"start": "2026-09-03T16:30Z", "end": "2026-09-03T17:00Z", "family": "Visibility", "description": "The error_value of PR07 rises all at once for one measurement, without rejection, and the corr_x of PR07, PR14 and PR18 jumps, then comes back; nothing clear on the 16:45 image (overcast sky). Cause not established; point to ignore.", "review": "2026-11-17"}
|
|
{"start": "2026-09-03T22:45Z", "end": "2026-09-04T00:30Z", "family": "Obstruction", "description": "A cobweb thread, lit by the infrared, passes as a pale band on the right of the scene (23:00 image), over PR07 and near PR14, PR15, PR16. PR07 is rejected for a few measurements, and PR14, PR15, PR16 depart on corr_x or corr_y for a while, then come back. Earlier in the evening, the same thread covered the reference CTR04 with no signal on the curves (19:00 image): according to the expert, the system then believes it sees its three references and can silently distort values. The structure does not move: ignore these curves over the range.", "review": "2026-11-17"}
|
|
{"start": "2026-09-04T01:00Z", "end": "2026-09-04T01:45Z", "family": "No data", "description": "Two measurements in a row are missing for all the sensors, at night: all the curves have a gap; the images are missing too, the voltage is normal around it. JUNGFRAU has the same gap at the same minutes: a common cause outside the station (transmission or reception of the data) is possible, not a station failure; it is not established. The curves then resume: nothing to do on the station.", "review": "2026-11-17"}
|