{"start": "2026-10-31T20:00Z", "end": "2026-10-31T20:30Z", "family": "Displacement", "description": "A single measurement after three weeks without measurement: the camera has nodded down a lot since 09/10 (its tilt well above that of early October, already slowly rising from 03/10 to 09/10), all the raw positions have risen in the image. The compensation runs on five references (R2 rejected), but almost all targets have their corrected curves shifted upward on corr_y, PB1_2 and PB2_2 the most, PA_9 on corr_x, and the reprojection errors of the references are higher than usual. No image at that hour. Cause not established: the camera has tilted, and the compensation does not quite catch up with it; a single point does not say whether it is lasting. To be checked: look at the mount of the camera, keep watching the next measurements.", "review": "2026-11-17"}
{"start": "2026-10-31T20:15Z", "end": "2026-11-01T00:00Z", "family": "No data", "description": "No measurement for any sensor until the end of the batch; the metrics stop at the same moment, although the battery was full and the voltage normal. This is not an end-of-file delay: nothing arrives on the following days either, when the other stations have their data. Cause not established (station stopped again). The curves are missing: to be checked with the operator.", "review": "2026-11-17"}