2.6 KiB
2.6 KiB
Tools: NORDEND_2026-11-05T0600_2026-11-05T1200
Tools modified: none data.py: unchanged
What the analyst used
inventory.pyon the range: references kept at each instant, rejections of CTR01 and PR09.overview.py --min 1(widened window from 04:00 to 14:00), then--rigid 2026-11-05T06:00Z --follow … --residuals no: the pose and the table by step dated the jolt of 12:00 (rotation, tilt, raw positions); the residual PNGs showed the drift of the right edge.ranges.py --columns corr_x,corr_y --rolling 4 --instants 3: under the thermal drift, it returned only two instants (09:45 with 3 sensors, 12:00 with 8), with the state of the references. It is the command that grounds the label.summary.py --step 15min --level window --mark(corr_y,error_value),metrics.py,plot.py --zone,thumbnails.py --radius 40, the whole image of 12:00.- The folder has no
scripts/: the analyst wrote no script. Its "Difficulties" mention only Ollama (labeling/precedents.py), which does not depend on this repository. Its "Documentation" section talks about the labeling rules, not about reading. - What was cluttering, slightly: a
| tail -22onsummary.pyand a| head -20onmetrics.py, to cut an output.--start/--endand the pipe togrepdescribed in the guide already do it.
What I decided
- All the tools used: left as they are. They showed what the analyst had to see: the one-measurement jolt under the drift (
ranges.py --rolling --instants), the pose and the references (overview.py,--rigid). Nothing was missing for it. summary.py,metrics.py: left as they are. Thehead/tailwere the analyst's choice, not a lack of the tool. The Conventions of the guide already say how to shorten an output.- No script to bring in:
scripts/does not exist.
What changed
none
Trial
No tool changed, so there was nothing new to try. I nevertheless reran, from tools/scripts/, the tools the report cites: the analysis ran just before commit 67c8862, which moved the tools into scripts/. The figures are stored in work/: common, multiples-error_value, residuals-corr_x/corr_y/error_value, rigid, metrics.
Report commands rerun
5, with the tools/scripts/ paths (overview.py --min 1, metrics.py, ranges.py --rolling 4 --instants 3, overview.py --rigid 2026-11-05T06:00Z, inventory.py): no failure. ranges.py returns the same two instants (09:45: 3 sensors; 12:00: 8 sensors) as those cited by the analyst.
Difficulties
- The log cites the tools at their old path (
tools/inventaire.py,tools/ensemble.py…). The report names them without a path. I reran withtools/scripts/, like the current guide.