{"start": "2026-10-01T06:15Z", "end": "2026-10-01T08:45Z", "family": "Visibility", "description": "The recognition error of most targets rises together, first a little, then clearly around 07:50-08:00, and comes back down; at the same time the corrected curves of several targets make a bump that comes back: D-301-C horizontally, D-302-B and PR_BG (same prism) vertically, D-306-B, D-303-B, P-301-B, then around 08:00 D-301-A, D-302_A, D-304-A. The scene deforms a little (scale and rotation of the targets, references PR-291 and PR-293 moving away from the targets), without camera movement. Nothing on the 07:00 and 08:00 images, which are dark as always. Diffuse obstruction of the view in the tunnel, cause not established (the tunnel air?); same signature as the episodes of 2, 6, 18, 22 and 31 October. The structure does not move: do not trust the curves over the range.", "review": "2026-11-17"}
{"start": "2026-10-02T21:30Z", "end": "2026-10-02T23:00Z", "family": "Visibility", "description": "The recognition error of most targets rises together for one hour, and the corrected curves of D-304-B (vertical) above all, of D-301-C (horizontal), D-302-B and PR_BG, P-301-B, D-304-C make a bump that comes back; D-304-B is still shifted at the last measurement, before 23:00. The camera housing temperature drops clearly at the same time. Nothing visible on the 22:00 image. Diffuse obstruction of the view, cause not established, perhaps a change in the tunnel air. The structure does not move: curves to ignore over the range.", "review": "2026-11-18"}
{"start": "2026-10-03T07:40Z", "end": "2026-10-03T08:00Z", "family": "No data", "description": "One measurement is missing, for all sensors: the curves have a short gap. Cause not established.", "review": "2026-11-17"}
{"start": "2026-10-03T17:30Z", "end": "2026-10-03T17:45Z", "family": "Visibility", "description": "Last measurement before the gap of 3 October: the same one-measurement bump on D-301-C, D-302-B and PR_BG, D-304-B, D-304-C, P-301-B, with the recognition error of many targets rising. Same signature as the episodes of view obstruction at the station; cause not established, perhaps linked to the station shutdown that follows. Point to ignore.", "review": "2026-11-17"}
{"start": "2026-10-03T17:45Z", "end": "2026-10-05T10:30Z", "family": "No data", "description": "No measurement or image for almost two days, for all sensors, and the station metrics are missing too: the entire station stopped. Voltage and battery normal before and after the gap, so not the signature of a power cut; on resumption, the camera has moved and a blurred object is very close to the lens (10:30 image), which suggests an intervention on the station. Cause not established: the curves are missing over the range.", "review": "2026-11-17"}
{"start": "2026-10-03T17:45Z", "end": "2026-10-05T10:45Z", "family": "Displacement", "description": "After the gap of 3 to 5 October, many targets resume at a different level, and do not return to the previous one until the end of the batch: D-304-C and D-303-C above all, in both directions, then D-302_A and D-301-A, P-299-B, D-300-C, D-303-B and D-304-B horizontally, D-301-C vertically; D-306-B, for its part, returns to its level from before its descent of the evening of the 1st. The raw positions of D-304-C and D-303-C have moved in the image relative to the other targets, the recognition error of several targets (D-302-C, D-301-C, D-303-C, D-304-C, D-301-A, D-306-B) also changes level, and the camera scale is no longer the same: the appearance of these targets and the camera pose changed during the shutdown. On resumption, a blurred object is very close to the lens (10:30 image). Cause not established: intervention or changed setting during the shutdown, or real movement; to be checked before trusting these new levels.", "review": "2026-11-17"}
{"start": "2026-10-05T10:30Z", "end": "2026-10-05T11:20Z", "family": "Obstruction", "description": "First measurement after the gap: the whole scene, references included, is shifted by several pixels in the image and the camera is tilted, then it returns within twenty minutes; the compensation absorbs it poorly for the duration of one measurement, and the corrected curves of many targets jump then return (D-303-C, D-302-B and PR_BG, D-306-B, D-304-B, P-299-C above all; D-303-B stays slightly shifted until 11:10). D-304-C is rejected. The 10:30 image shows a large blurred object very close to the lens, on the right, which hides D-304-C, and a worker in reflective clothing in the tunnel, at the top left: work is going on around the camera. Points to ignore; the structure does not move.", "review": "2026-11-17"}
{"start": "2026-10-05T12:10Z", "end": "2026-10-05T12:30Z", "family": "Obstruction", "description": "For the duration of one measurement, the whole right-hand row C (D-300-C, D-301-C, D-303-C, D-304-C, P-298-C, P-299-C) and the reference D-302-C are rejected, their recognition error almost at 1; the compensation runs without D-302-C and the targets that stayed under the threshold jump then return at the next measurement (D-306-B above all vertically, D-303-B, D-304-B, P-299-B, P-301-B, D-302-B and PR_BG). No image at 12:20: the cause is not seen, but the signature is that of something passing in front of the right-hand part of the scene. Point to ignore.", "review": "2026-11-17"}
{"start": "2026-10-06T18:00Z", "end": "2026-10-06T22:10Z", "family": "Visibility", "description": "For four hours, the corrected curves of the same group of targets take a step that starts and ends sharply: D-301-C horizontally above all, D-302-B and PR_BG (same prism) horizontally then vertically, D-304-B vertically, and at times P-301-B, D-303-B, D-302_A, D-301-A, D-304-C. The recognition error of the references PR-293, PR-295, PR-296 and of a few targets rises a little; the references move away from each other in the image. The camera housing temperature drops clearly over these hours. Nothing visible on the 20:00 image. View obstruction of cause not established, probably the tunnel air (colder); the curves and the recognition error return at 22:00, before the camera scale. The structure does not move: curves to ignore over the range."}