{"start": "2026-10-15T22:50Z", "end": "2026-10-16T10:30Z", "family": "No data", "description": "No measurement or image for almost twelve hours, on the night of 15 to 16, and no station metric. The gap starts at the same time, around 23:00, on the nine stations that were measuring then (LENZSPITZE only has its first measurements in the middle of that night, WILDSTRUBEL is already stopped), and their metrics stop at the same time on most of them; measurements and metrics resume at different times depending on the station, most of them in late morning. JUNGFRAU, whose metrics continue, accumulates unsent entries all night, sent in late morning, and yet its measurements for the night are missing from the data: a common cause outside the stations (transmission or reception of the data), not a shutdown of the stations; it is not established. In addition, at CLARIDEN, the station restarts on its battery: the voltage stays well below its usual level, without charge, until early afternoon, then charging resumes; its power supply was also missing that night. The curves are missing over the range; check the site power supply if it repeats.", "review": "2026-11-18"}
{"start": "2026-10-16T14:20Z", "end": "2026-10-16T14:40Z", "family": "No data", "description": "One measurement is missing, for all sensors, a few hours after the resumption of the 16th: the curves have a short gap; normal voltage around it. The same gap falls at the same moment on the other stations measuring at that time (FLORIDA, LENZSPITZE, NORDEND, SNCF01): a common cause outside the station (transmission or reception of the data), not a failure of the station; it is not established. The curves are missing over the range; nothing to do on the station.", "review": "2026-11-17"}
{"start": "2026-10-18T08:50Z", "end": "2026-10-18T09:30Z", "family": "Visibility", "description": "For three measurements, the corrected curves of many targets make a bump that comes back: first the targets of row A (D-300-A, D-301-A, D-302_A, D-303-A, D-304-A, P-298-A) rise vertically; over the next two measurements, the recognition error of most targets and of the references PR-293 and PR-295 rises, D-302-B and PR_BG (same prism) rise strongly vertically, D-301-C goes down strongly horizontally, and P-301-B and D-303-B move horizontally. All come back at the following measurement. The camera pose jumps at the same time (tilt, scale), and the housing temperature drops. The image of the first measurement shows nothing in front of the targets. The signature is that of the other view obstruction episodes at the station: the error rises on most sensors, and the edges are sharp. Reduced visibility is deduced from it; the cause is not seen. Points to ignore.", "review": "2026-11-18"}
{"start": "2026-10-18T13:50Z", "end": "2026-10-18T23:30Z", "family": "No data", "description": "No measurement or image for almost ten hours, nor station metric. On resumption, the battery is depleted and the voltage low, then they rise: signature of a power cut. The curves are missing over the range; check the power supply if it repeats.", "review": "2026-11-18"}
{"start": "2026-10-19T09:00Z", "end": "2026-10-19T10:10Z", "family": "No data", "description": "Four measurements are missing within one hour, for all sensors, between isolated measurements: the curves have gaps; normal voltage around them. The same gap falls at the same moment on the other stations measuring at that time (FLORIDA, JUNGFRAU, LENZSPITZE, NIEDERHORN, NORDEND, SNCF01): a common cause outside the station (transmission or reception of the data), not a failure of the station; it is not established. The curves are missing over the range; nothing to do on the station.", "review": "2026-11-18"}
{"start": "2026-10-19T20:40Z", "end": "2026-10-19T21:30Z", "family": "No data", "description": "Three measurements are missing in less than an hour, for all sensors: the curves have a gap; normal voltage around it. The same gap falls at the same moment on the other stations measuring at that time (FLORIDA, JUNGFRAU, LENZSPITZE, NIEDERHORN, NORDEND, SNCF01): a common cause outside the station (transmission or reception of the data), not a failure of the station; it is not established. The curves are missing over the range; nothing to do on the station. The hourly metrics of BREITHORN, MICHIGAN and NEBRASKA are also missing at 21:00.", "review": "2026-11-18"}