15 lines
9.1 KiB
JSON
15 lines
9.1 KiB
JSON
{"start": "2026-10-20T04:00Z", "end": "2026-10-25T18:00Z", "family": "Displacement", "description": "Slow drift of targets of row C, then stabilization at a new level: D-301-C rises horizontally from the 20th, D-304-C and D-303-C rise vertically mostly from the 22nd. No camera movement, ordinary recognition error. The rise of D-301-C starts before the work seen around the station on the 22nd (workers and a frame): no link established. The position in the image of D-301-C, D-304-C and D-303-C moves clearly away from that of the other targets, in the direction of their curves. The camera housing temperature stays almost constant over these days: no link with it. D-304-C and D-303-C then come back down a little from the 26th to the 29th, without returning to their level from before: too small to be labeled. Cause not established, in a tunnel under construction: a movement of these targets is not excluded. To be checked against the other measurements of the site; monitor this row.", "review": "2026-11-18"}
|
|
{"start": "2026-10-20T06:10Z", "end": "2026-10-20T06:30Z", "family": "No data", "description": "One measurement is missing, for all sensors: the curves have a short gap; the station nevertheless synchronizes at that moment, normal voltage. The same moment is also missing at LENZSPITZE, and at no other station: a common cause outside the station is possible, not established. Nothing to do.", "review": "2026-11-17"}
|
|
{"start": "2026-10-20T20:40Z", "end": "2026-10-20T21:40Z", "family": "No data", "description": "Five measurements are missing within one hour, for all sensors: the curves have a gap. The station is nevertheless running (continuous synchronizations, 21:00 image, normal voltage): the measurement is not made or not recorded. The 21:00 measurement is also missing at NIEDERHORN, and at no other station: a common cause is possible, not established. Nothing to do.", "review": "2026-11-18"}
|
|
{"start": "2026-10-22T06:30Z", "end": "2026-10-22T08:50Z", "family": "Visibility", "description": "In two phases, from 06:40 to 06:50 then from 07:50 to 08:30, the recognition error of several targets and of the references D-302-C and PR-293 rises, and the corrected curves of the usual group make a bump that comes back: D-301-C horizontally, D-302-B and PR_BG vertically, P-301-B, D-304-B, D-304-C, and at the start D-302_A, P-298-A, D-304-A, D-303-A; between the two, D-302-B and PR_BG move once more. The camera housing temperature drops during these hours. The 08:00 image shows lights at the far end of the tunnel (machine or vehicle), nothing in front of the targets. Diffuse view obstruction of cause not established, the same as in the other episodes at the station. Curves to ignore over the range; the structure does not move.", "review": "2026-11-18"}
|
|
{"start": "2026-10-26T14:30Z", "end": "2026-10-26T15:10Z", "family": "No data", "description": "Three measurements are missing in less than an hour, for all sensors: the curves have a gap; normal voltage around it. The same gap falls at the same moment on the other stations measuring at that time (FLORIDA, JUNGFRAU, LENZSPITZE, NIEDERHORN, NORDEND, SNCF01), and their metrics are also missing at the same minutes: a common cause outside the station (transmission or reception of the data), not a failure of the station; it is not established. The curves are missing over the range; nothing to do on the station. The hourly metrics of BREITHORN, MICHIGAN and NEBRASKA are also missing at 15:00.", "review": "2026-11-18"}
|
|
{"start": "2026-10-27T09:00Z", "end": "2026-10-27T09:30Z", "family": "No data", "description": "Two measurements are missing, for all sensors: the curves have a short gap; normal voltage around it. The same gap falls at the same moment on the other stations measuring at that time (FLORIDA, JUNGFRAU, LENZSPITZE, NORDEND): a common cause outside the station (transmission or reception of the data), not a failure of the station; it is not established. The curves are missing over the range; nothing to do on the station.", "review": "2026-11-17"}
|
|
{"start": "2026-10-27T12:00Z", "end": "2026-10-27T12:20Z", "family": "Target issue", "description": "For the duration of one measurement, the target PR-284 jumps by several pixels horizontally and vertically, then returns: the measured position has left its spot, with a high recognition error but under the threshold, so kept in the curve. Since 24 October around 14:20, the spot of PR-284 is clearly weaker (thumbnails of the 24th at 12:00 and 16:00, of the 27th at 12:00) and its recognition error has stayed high. False point to ignore; look at the state of the target PR-284 if the false points repeat.", "review": "2026-11-17"}
|
|
{"start": "2026-10-29T14:50Z", "end": "2026-10-29T15:10Z", "family": "No data", "description": "One measurement is missing, for all sensors: the curves have a short gap; the station nevertheless synchronizes at that moment, normal voltage. The same gap falls at the same moment on the other stations measuring at that time (LENZSPITZE, NORDEND, SNCF01): a common cause outside the station (transmission or reception of the data), not a failure of the station; it is not established. The curves are missing over the range; nothing to do on the station.", "review": "2026-11-17"}
|
|
{"start": "2026-10-29T23:50Z", "end": "2026-10-30T00:10Z", "family": "Target issue", "description": "At midnight, D-302-B jumps vertically and a little horizontally and stays at this new level until the end of the batch; PR_BG, on the same prism, jumps in the opposite direction. The raw positions of the two sensors do not move, only their starting position has changed (the relative displacement jumps without any movement in the image): a configuration or processing change of these two sensors, not a movement of the structure. Check their configuration with the operator; do not read this jump as a movement, nor compare their curves before and after.", "review": "2026-11-18"}
|
|
{"start": "2026-10-30T17:00Z", "end": "2026-10-30T17:50Z", "family": "No data", "description": "Four measurements are missing in less than an hour, for all sensors: the curves have a gap. The station's own record stops too: its minute-by-minute synchronizations are missing over the same half hour, while the 17:00 image exists and the voltage stays normal before and after, so it is not a lack of energy. The other stations measuring at that time (ALASKA, FLORIDA, JUNGFRAU, LENZSPITZE, NADELHORN, NORDEND, SNCF01, WYOMING) have their measurements: the cause is specific to the station, not established. The curves are missing over the range; nothing to do unless it repeats.", "review": "2026-11-18"}
|
|
{"start": "2026-10-31T09:20Z", "end": "2026-10-31T15:00Z", "family": "Thermal displacement", "description": "The camera housing temperature rises a little in the late morning of the 31st, and the camera scale rises with it while the pan goes down, until early afternoon; they come back when the housing cools, mostly during the view obstruction of the early afternoon, labeled separately. The compensation absorbs most of it, but a few corrected curves follow a little over these hours and come back with it: D-301-C horizontally, D-304-C, D-303-C and D-304-B vertically. Only a light at the far end of the tunnel on the 12:00 image, nothing in front of the targets. Camera movement by thermal effect, deduced from its pose against the housing temperature; normal, nothing to do.", "review": "2026-11-18"}
|
|
{"start": "2026-10-31T13:50Z", "end": "2026-10-31T15:10Z", "family": "Visibility", "description": "For one hour, the corrected curves of the usual group make a bump that comes back: D-301-C (horizontal), D-302-B and PR_BG (vertical), D-301-A, D-300-A, D-304-B, D-304-C, D-302_A, and for a moment the reference PR-295; the recognition error of a few sensors rises during the episode. Same signature as the other episodes of view obstruction at the station; cause not established. Curves to ignore over the range.", "review": "2026-11-18"}
|
|
{"start": "2026-10-31T18:40Z", "end": "2026-10-31T20:00Z", "family": "Visibility", "description": "For the duration of a few measurements, the corrected curves of D-301-C, P-301-B, P-299-A, D-302-B and PR_BG, D-303-B make a bump that comes back, and the reference PR-295, which is seen less well from 18:50, leaves its level; it is rejected at 19:50 (its curve is missing at that measurement), without the targets moving because of it. View obstruction of cause not established; points to ignore.", "review": "2026-11-18"}
|
|
{"start": "2026-10-31T22:20Z", "end": "2026-11-01T00:00Z", "family": "Visibility", "description": "The reference PR-295 is seen poorly: its spot is weaker (23:00 thumbnail), it is rejected at times and, between two rejections, it is poorly measured; the compensation changes basis, and at 22:50 many targets jump together then return, without any movement of their raw positions. Until 23:50, the curves of D-301-C, P-301-B, D-302-B and PR_BG stay shifted, then briefly cross to the other side, with the recognition error of several targets rising. The camera housing temperature drops clearly at that hour. Cause of the obstruction not established (same signature as the other episodes). The jumps are not a movement: curves to ignore over the range.", "review": "2026-11-18"}
|