Files
aimsight-labeling/stations.md
T
2026-11-18 10:51:31 +01:00

3.0 KiB

The stations

What each station is: its structure, its camera, its references, its neighbours. Context for reading a station's data, not a rule: what happens at a station is in its labels (auto/<STATION>.jsonl), searched by scripts/precedents.py; what generalizes in the cases (auto/cases/, scripts/cases.py). The kind of structure says whether a thermal movement of the structure is possible (reading-rules.md, section 3). Cases are cited by label id; [expert]: the expert's word. Maintained by hand: a new station gets its row when its first range is analysed.

Station Structure Camera References Neighbouring cameras
BREITHORN in a building (a factory, indoors) [expert] one measurement every four hours; COLJ19 and POUI19 much closer to the camera than the other targets [expert]; the camera nods forward over October, compensation incomplete [expert] REFH22, REFPOU22 among the sensors at the bottom of the image MICHIGAN and NEBRASKA, in the same building: a drift common to the three [BREITHORN-2]
CLARIDEN a tunnel under construction, with other measurement systems [expert] images always dark; on mains four references, D-302-C, PR-291, PR-293, PR-295; PR-284 is a local reference, read as a target; D-302-B and PR_BG on the same prism [CLARIDEN-65] —
FLORIDA — — two references only, p1_r and r1_r, each with its twin target (Sellette 3, Pont Ernen) [expert] its one-measurement gaps at night fall at the same instants as SNCF01's
JUNGFRAU a bridge, which rises as it cools [expert] under the deck, fixed to the bridge three references off the bridge, REF_D, REF_G, REF_CT —
LENZSPITZE a railway seen from under a bridge, a work site and machines next to it recent camera, with image quality; x, y relative in the export (tools/DATA.md); only temperature_deg_c is filled nine references, including the distant 8011 to 8014 —
MICHIGAN in the same building as BREITHORN, indoors [expert] one measurement every four hours two references since the loss of REFPOU22 on 09.10 [MICHIGAN-3]; COLH21' and REFH22' on the same point until 05.10 [MICHIGAN-1] BREITHORN, NEBRASKA: lost a reference at the same measurement as NEBRASKA
NEBRASKA in the same building as BREITHORN [expert] one measurement every four hours two references since the loss of REFCOLH22 [NEBRASKA-2] BREITHORN, MICHIGAN
NIEDERHORN railway tracks floodlight at night higher up, on the road above the tracks (PWD_REF08 to PWD_REF12) —
NORDEND a quarry: a rock face too massive to move with the temperature [expert] infrared lighting at night; DIFF images three references, CTR02, CTR03, CTR04; CTR01 is a local reference, read as a target —
SNCF01 a masonry wall along railway tracks no system metrics, hence no temperature three references, BG.3.1, R1, R2 FLORIDA (gaps at the same instants)
WILDSTRUBEL a road, in a town [expert] solar battery six references, R1 and R2 at the edge of the road; R3 invisible by day [WILDSTRUBEL-130] —