Files
aimsight-labeling/auto/analyses/CLARIDEN_2026-10-01T0000_2026-10-11T0000/report.md
T
maximeandClaude Opus 5.5 ddb17c2189 auto: labels requalified under the 5-noise rules (only what stands out from the noise): 32 analyses refined, the 6 paused periods verified, the long labels requalified with the fixes the period analysts found; 1153 -> 961 labels
- 32 analyses: each label kept, rewritten or removed by its analyst (section Requalification of the report; mm magnitudes where the targets have them)
- SNCF01 x3, WILDSTRUBEL 2026-09-01 -> 2026-10-06 x3: verified from their existing labels under the new rules
- long labels (no analysis): auto/analyses/long-labels/<STATION>/; NORDEND-169 and -195 run to 07/11, so NORDEND-283 and -284 (their continuation) are removed
- reading-rules.md, stations.md: the citations of removed or rewritten labels point to their successor, or to [expert]

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-17 23:58:00 +01:00

6.3 KiB
Raw Blame History

CLARIDEN: requalified labels, 1 to 11 October

You asked to requalify the labels of 1 October 00:00 to 11 October 00:00 (UTC) under the new rules: keep only what stands out from the noise of the corrected curves.

In short

13 of the 16 labels stay. The 3 removed ones did not move the corrected curves beyond their noise: two camera movements caused by temperature, which the correction absorbs, and one small step on 8 October. The curves cannot be trusted during the short "view obstruction" episodes, around the outage of 3 to 5 October, and on D-303-B after the camera step of 6 October. No real movement of the structure is established. The drop of row B on 1 October is still unexplained.

What happened

There is no weather data for this station. It is in a tunnel, so the weather matters little. The targets are 2 to 17 m from the camera.

Short view obstructions (1 Oct morning, 2 Oct evening, 3 Oct 17:40, 6 Oct evening). The recognition error of most targets rises at the same moment, for one to four hours. The same group of targets bumps and then comes back: D-301-C by up to about 0.9 mm sideways (12 m away), D-302-B by about 0.4 mm, D-304-B and P-301-B by 0.2 to 0.4 mm. The camera housing cools at the same time. Nothing shows on the images. Cause unknown, possibly the tunnel air (likely, not confirmed).

Row B drops on the evening of 1 October. D-306-B, D-304-B and D-303-B go down by 0.1 to 0.25 mm. The camera does not move and nothing shows on the images. D-303-B climbs back by about 0.27 mm over the next day and night. The other two stay low until the outage. Cause unknown. A real movement of these targets is possible.

Row B and P-301-B, 1 to 3 October The blue curve (D-303-B) falls with the others on the evening of the 1st, then climbs back alone. The red curve (P-301-B) jumps up on the morning of the 3rd.

P-301-B alone, 3 October. Around 09:50 its vertical curve jumps up by about 0.4 mm. It stays there until early afternoon, then comes back by late afternoon. Its own recognition error rises at the same time, and its neighbours do not move. The images show a clean spot. Cause unknown. Most likely something changed in how this one target is seen, not a movement.

The station stops for almost two days (3 Oct 17:50 to 5 Oct 10:30). There are no measurements and no images. The power is normal before and after the stop. At the restart, the 10:30 image shows a large blurred object right in front of the lens and a worker in the tunnel. The first measurement is off by up to about 1 to 2 mm, and 12:20 again by about 0.4 mm, when something passes in front of the right part of the scene. After the stop, several targets sit at a new level: D-303-C by about 1.8 mm sideways, D-304-C by about 1.5 mm vertically, D-306-B by about 0.5 mm. An intervention during the stop is likely. A real movement is not excluded.

Camera step on 6 October. At 13:10 the camera tilts slightly and keeps the new position. The correction absorbs this for every target except D-303-B: it drops by about 0.2 mm and stays low. This is what is left of the camera movement, not a movement of the structure (confirmed). The opposite step on 8 October leaves D-303-B within its noise, so it is no longer labelled.

D-303-B against the camera tilt, 5 to 11 October The blue curve (D-303-B) and the red one (the tilt, upside down) move together.

What to do

  • Ask the site what was done at the camera between 3 and 5 October, and whether the camera mount was touched on 6 October.
  • Check how the camera is fixed: its tilt moves in steps.
  • Compare the drop of row B on 1 October and the new levels after the outage with the site's other measurements.

Not established

  • The cause of the view obstructions. A measurement of the tunnel air at the camera (temperature, dust) would settle it.
  • Whether row B really went down on 1 October, and whether the new levels after the outage are real. The site's own surveys of these targets would settle it.
  • Why P-301-B jumped on 3 October.

Requalification

16 labels: 12 kept, 1 rewritten, 3 removed.

  • CLARIDEN-5 (camera thermal movement, 2 Oct 21:50–23:20): removed. The correction absorbs it. Outside the view obstruction of the same evening, no target goes beyond 5 noises.
  • CLARIDEN-13 (camera thermal movement, 6 Oct 18:40–22:40): removed, for the same reason. After 22:00, no target goes beyond 5 noises.
  • CLARIDEN-48 (camera step, 8 Oct 08:50–09:10): removed. What is left on D-303-B reaches only 4.2 noises (about 0.12 mm), and no other target reaches 5.
  • CLARIDEN-47 (camera step, 6 Oct 13:00–13:30): rewritten. It is kept (D-303-B reaches 8.2 noises), but its text pointed to the removed step of the 8th.

Labels

Start (UTC) End (UTC) Family Targets In a few words
2026-10-01 06:15 2026-10-01 08:45 Visibility D-301-C, D-302-B, PR_BG, D-304-B, P-301-B, row A View obstruction, curves bump and come back
2026-10-01 17:45 2026-10-02 02:30 Displacement D-306-B, D-304-B, D-303-B Row B goes down, cause unknown
2026-10-02 03:40 2026-10-03 03:00 Displacement D-303-B Climbs back to its level from before the drop
2026-10-02 21:30 2026-10-02 23:00 Visibility D-301-C, D-304-B, D-302-B, PR_BG, P-301-B, D-304-C View obstruction, curves bump and come back
2026-10-03 07:40 2026-10-03 08:00 No data all One measurement missing
2026-10-03 09:40 2026-10-03 17:00 Displacement P-301-B Jumps up alone, then comes back
2026-10-03 17:30 2026-10-03 17:45 Visibility D-302-B, PR_BG, D-301-C, D-304-C, D-304-B, P-301-B Last point before the outage, disturbed
2026-10-03 17:45 2026-10-05 10:30 No data all Station stopped for almost two days
2026-10-03 17:45 2026-10-05 10:45 Displacement D-303-C, D-304-C, D-306-B, others New levels after the outage
2026-10-05 10:30 2026-10-05 11:20 Obstruction whole scene Object at the lens, work at the camera
2026-10-05 12:10 2026-10-05 12:30 Obstruction D-306-B, row B, via row C and D-302-C Something passes in front, one point
2026-10-06 13:00 2026-10-06 13:30 Displacement D-303-B Camera tilt step, D-303-B keeps a step down
2026-10-06 18:00 2026-10-06 22:10 Visibility D-301-C, D-302-B, PR_BG, D-304-B View obstruction for four hours