{"start": "2026-09-30T00:00Z", "end": "2026-09-30T07:15Z", "family": "Thermal displacement", "description": "End of the night cooling, begun before the batch: the vertical corrections (corr_y) of the bridge targets rise slowly until early morning, mostly PBJ_C, PM_D, PM_C and BJ_D; the corrections of the references REF_CT, REF_D and REF_G stay stable, the error_value of all the targets is stable, the camera pose hardly moves. The camera housing temperature drops until morning. Cause deduced from the curves and the temperature: the bridge rises as it cools. Normal thermal movement of the structure, nothing to do.", "review": "2026-11-17"}
{"start": "2026-09-30T07:30Z", "end": "2026-09-30T17:00Z", "family": "Thermal displacement", "description": "Warming of the day, with little sun (the station voltage hardly rises): the camera, fixed to the bridge, moves from the morning (pan, rotation and scale rise until the middle of the afternoon) and the raw positions of the three references and of all the targets move together in the image; this movement is well compensated, the corr_x stay flat. The corr_y of the bridge targets (PBJ_C, PM_D, PM_C, BJ_D) sink moderately until late afternoon; corrections of the references almost flat, error_value stable. Deduced from the curves, the camera pose and the camera housing temperature, which rises. Normal thermal effect of the bridge and of the camera support, nothing to do.", "review": "2026-11-17"}
{"start": "2026-09-30T17:15Z", "end": "2026-10-01T04:30Z", "family": "Thermal displacement", "description": "Cooling of the evening and the night: the camera comes back (pan, scale, raw positions of all the sensors return together), and the corr_y of the bridge targets (PBJ_C, PM_D, PM_C, BJ_D) rise all night, then stabilize before daylight; corrections of the references stable, error_value stable. Deduced from the curves and the camera housing temperature, which drops. The bridge rises as it cools: normal thermal movement, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-01T06:15Z", "end": "2026-10-01T07:45Z", "family": "Visibility", "description": "At the change from night to day, on an overcast morning: the error_value of most targets (BL_C, PBL_C, PM_C, and the three targets BJ_G, BJ_C, BJ_D) rises a little for about an hour, then drops all at once at 07:45. Meanwhile the corr_y of BJ_G, BJ_C and BJ_D sinks clearly, the corr_x of BJ_G goes down and that of BJ_D goes up (the two move apart), then all three come back at once with the error_value; the other targets hardly move, the references stay calm and the camera pose does not move. Images of 06:00, 07:00 and 07:30: nothing in front of the targets, no fog seen, spots like at 07:45 and like the day before at the same hour. Cause not established: a brief degradation of the image at daybreak, deduced from the error_value rising on most targets together with sharp edges. This is not a movement: points not to be trusted.", "review": "2026-11-18"}
{"start": "2026-10-01T07:45Z", "end": "2026-10-01T11:15Z", "family": "Thermal displacement", "description": "Weak warming of an overcast morning: the camera housing temperature rises a little and the corrected curves keep a small slow drift: the corr_y of BL_G sinks steadily all morning, that of PBL_D rises a little, the corr_y of PBJ_C and PM_D begin to sink in late morning, and the corr_x of BL_C rises a little then comes back. At the same time the camera tilts slowly (the tilt goes down, the pan and the scale rise a little), the raw positions of all the sensors moving together, a movement mostly absorbed by the compensation. References stable, error_value at its level. Deduced from the corrected curves, the camera pose and the housing temperature. From late morning the drop in visibility, labeled apart, takes over and hides the rest of the cycle. Normal thermal movement of the bridge and of the camera fixed to it, nothing to do.", "review": "2026-11-18"}
{"start": "2026-10-01T11:15Z", "end": "2026-10-01T21:30Z", "family": "Visibility", "description": "Reduced visibility over the whole scene, on a day without sun: the error_value of almost all the targets and of the reference REF_G rises clearly from late morning, in steps, stays high in the afternoon and evening, then drops all at once in the evening; PM_C is rejected all afternoon and evening, PM_D approaches its threshold. The corrected curves become agitated, with apparent movements that disappear when visibility returns: corr_y of BJ_C, BJ_D and BJ_G sinking, corr_x of BJ_G, PBL_C, BJ_D and PM_D moving away; the corrections of the references REF_CT, REF_D and REF_G also deviate and the camera pose is agitated, but the three references remain retained, none is rejected. Images: nothing in front of the targets; the spots are smaller and weaker than at the same hour on other days, and at night the background is more veiled, with reflections on the roadway. Cause deduced from the weather: the nearby MeteoSwiss station measures rain from early afternoon to early evening, with the air close to saturation, and its humidity drops in the evening at the hour the error_value falls back; the drops themselves are not seen on the images. Data less precise over the range, the structure does not move: nothing to do.", "review": "2026-11-18"}
{"start": "2026-10-01T21:30Z", "end": "2026-10-02T06:30Z", "family": "Thermal displacement", "description": "Cooling of the night, after a day without sun: the camera housing temperature drops clearly; the corr_y of the bridge targets (PBJ_C, PM_D, PM_C) rise all night, and the corr_x of BJ_D and BJ_G slowly move apart, in opposite directions; corrections of the references stable, error_value at the usual night level. Deduced from the curves and the temperature. The bridge rises as it cools: normal thermal movement, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-02T01:45Z", "end": "2026-10-02T03:45Z", "family": "Visibility", "description": "The reference REF_G is seen less well in the middle of the night: its error_value jumps clearly, stays high a little over an hour, then drops all at once; that of REF_D also rises a little; none is rejected, the three references remain retained. The camera pose, computed on the references, changes all at once (pan, rotation, sigma0) while the raw positions of the targets do not move: the basis is distorted, and the corr_x of several targets (BJ_G, BJ_C, PBJ_C, BL_G, PM_C) jump, then return as soon as REF_G is well seen again. Images: the spot of REF_G, and that of REF_D, are smaller and weaker than before and after, nothing visible in front; the cause is not established. The jumps are not a movement of the structure: points to ignore, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-02T06:45Z", "end": "2026-10-02T17:30Z", "family": "Thermal displacement", "description": "Warming of a sunny day (the station voltage rises with the sun): from the morning the camera moves (pose and raw positions of all the sensors together), then the bridge targets move strongly: the corr_y of PBJ_C, PM_D, PM_C, BJ_D, BJ_C and BJ_G sink until late afternoon, the corr_x of BJ_C, BJ_G, PBJ_C, PM_C and PM_D rise until the middle of the afternoon. The references REF_CT, REF_D and REF_G keep almost flat corrections and shift relative to the block of targets; the error_value of the targets drops a little in the sun; around noon, the camera pose becomes agitated from one measurement to the next and REF_D has a few error_value peaks, without rejection or visible effect on the corrections. Deduced from the curves, the camera pose and the camera housing temperature. The bridge expands in the sun, poorly compensated by the camera fixed to it: normal thermal movement, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-02T11:15Z", "end": "2026-10-02T11:45Z", "family": "No data", "description": "One measurement is missing for all sensors, and the image of that moment too; the station nevertheless synchronizes at that moment and its voltage is normal (metrics): it is running, the measurement is not made or not recorded; only station affected that day at that hour, cause not established. The curves resume at the next measurement: nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-02T12:00Z", "end": "2026-10-02T12:30Z", "family": "No data", "description": "One measurement is missing for all sensors, and the image of that moment too; the station nevertheless synchronizes at that moment and its voltage is normal (metrics): it is running, the measurement is not made or not recorded; only station affected that day at that hour, cause not established. The curves resume at the next measurement: nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-02T13:15Z", "end": "2026-10-02T13:45Z", "family": "No data", "description": "One measurement is missing for all sensors, and the image of that moment too; the station nevertheless synchronizes at that moment and its voltage is normal (metrics): it is running, the measurement is not made or not recorded; only station affected that day at that hour, cause not established. The curves resume at the next measurement: nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-02T17:45Z", "end": "2026-10-03T06:45Z", "family": "Thermal displacement", "description": "Cooling of the evening and the night: the camera comes back (pose, raw positions of all the sensors), the corr_x of the bridge targets go back down in the evening, and the corr_y of PBJ_C, PM_D, PM_C, BJ_D, BJ_C and BJ_G rise all night until morning; corrections of the references stable, error_value stable. Deduced from the curves and the camera housing temperature, which drops. The bridge rises as it cools: normal thermal movement, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-03T07:00Z", "end": "2026-10-03T17:00Z", "family": "Thermal displacement", "description": "Warming of a sunny day: from the morning the camera moves (pose and raw positions of all the sensors together, pose agitated from one measurement to the next in late morning), the corr_y of the bridge targets (PBJ_C, PM_D, PM_C, BJ_D, BJ_C, BJ_G) sink until late afternoon; the corr_x move much less than the day before (BL_C and BL_G rise a little). Corrections of the references almost flat, error_value stable. Deduced from the curves, the pose and the camera housing temperature. The bridge expands in the sun, poorly compensated by the camera fixed to it: normal thermal movement, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-03T17:15Z", "end": "2026-10-04T06:45Z", "family": "Thermal displacement", "description": "Cooling of the evening and the night: the camera comes back (pose, raw positions), the corr_y of the bridge targets rise, clearly in the evening, then more gently at night (PBJ_C, PM_D above all), the camera housing temperature dropping little that night; corrections of the references stable, error_value stable. Deduced from the curves and the temperature. The bridge rises as it cools: normal thermal movement, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-04T07:00Z", "end": "2026-10-04T17:15Z", "family": "Thermal displacement", "description": "Warming of the day, sunny mostly around noon: from the morning the camera moves (pose and raw positions of all the sensors together), the corr_y of the bridge targets (PBJ_C, PM_D, PM_C, BJ_D, BJ_C, BJ_G) sink until late afternoon, the corr_x of BJ_G, PBJ_C, PM_C, BL_C and BJ_C rise moderately in the early afternoon. Corrections of the references almost flat, error_value stable. Deduced from the curves, the pose and the camera housing temperature. The bridge expands in the sun, poorly compensated by the camera fixed to it: normal thermal movement, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-04T17:30Z", "end": "2026-10-05T06:15Z", "family": "Thermal displacement", "description": "Cooling of the evening and the night: the camera comes back (pose, raw positions of all the sensors), the corr_y of the bridge targets (PBJ_C, PM_D, PM_C, BJ_D, BJ_C, BJ_G) rise all night until morning, the camera housing temperature dropping clearly; corrections of the references stable, error_value stable. Deduced from the curves and the temperature. The bridge rises as it cools: normal thermal movement, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-04T19:30Z", "end": "2026-10-04T20:00Z", "family": "Perturbation", "description": "In the evening, for the duration of one measurement, the corr_x of most targets (PM_C, BL_G, BJ_D, BJ_C, PM_D, PBL_D) shift a little together, then come back at the next one; the corrections of the references REF_CT and REF_D move apart in opposite directions and the camera scale jumps. On the raw positions, only REF_D shifts, the targets do not move in the image: the base of the compensation changes for one measurement, all three references retained, error_value stable. Thumbnail of 19:45: spot of REF_D unchanged, nothing in front. Cause not established. It is not a movement of the structure: point to ignore.", "review": "2026-11-18"}
{"start": "2026-10-05T06:00Z", "end": "2026-10-05T06:30Z", "family": "No data", "description": "One measurement is missing for all sensors, although the image of that moment exists; the station nevertheless synchronizes at that moment and its voltage is normal (metrics): it is running, the measurement is not made or not recorded; only station affected that day at that hour, cause not established. The curves resume at the next measurement: nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-05T06:30Z", "end": "2026-10-05T17:15Z", "family": "Thermal displacement", "description": "Warming of a very sunny day, the strongest of the batch: from the morning the camera moves (pose and raw positions of all the sensors together, pose agitated from one measurement to the next around noon), the corr_y of the bridge targets (PBJ_C, PM_D, PM_C, BJ_D, BJ_C, BJ_G) sink until late afternoon, the corr_x of BJ_G, PBJ_C, BJ_C, PM_C and PM_D rise strongly until the middle of the afternoon. Corrections of the references almost flat; REF_D has error_value peaks in the morning, REF_CT and REF_G in the afternoon, without rejection or clear effect on the corrections; the error_value of the targets drops a little in the sun. Deduced from the curves, the pose and the camera housing temperature. The bridge expands in the sun, poorly compensated by the camera fixed to it: normal thermal movement, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-05T10:30Z", "end": "2026-10-05T11:00Z", "family": "No data", "description": "One measurement is missing for all sensors, and the image of that moment too; the station nevertheless synchronizes at that moment and its voltage is normal (metrics): it is running, the measurement is not made or not recorded; only station affected that day at that hour, cause not established. The curves resume at the next measurement: nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-05T16:00Z", "end": "2026-10-05T16:30Z", "family": "Visibility", "description": "Small one-measurement jump on the corr_x of a few targets (BJ_C, BJ_G, BL_D, PBJ_C), then partial return. The error_value of the reference REF_G rises for the duration of one measurement, under its threshold: on the 16:15 thumbnail, the background behind it, and that of REF_CT, are in full sun and its spot drowns in it; the compensation is slightly distorted by it. This is not a movement; nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-05T17:30Z", "end": "2026-10-06T07:00Z", "family": "Thermal displacement", "description": "Cooling of the evening and the night: the camera comes back (pose, raw positions of all the sensors), the corr_x of the bridge targets go back down, and the corr_y of the bridge targets (PBJ_C, PM_D, PM_C, BJ_D, BJ_C, BJ_G) rises steadily until the morning of 06/10, the camera tilt follows; references stable, ordinary error_value. Deduced from the curves and the camera housing temperature, which drops. The bridge rises as it cools: normal thermal movement, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-06T05:45Z", "end": "2026-10-06T06:15Z", "family": "Obstruction", "description": "Jump of all the targets on corr_x and corr_y for the duration of one measurement, then return. A truck is in front of the reference REF_G (seen on the 06:00 image): its measurement is rejected, the compensation has nothing left to register on and the basis jumps. This is not a movement; ignore this point.", "review": "2026-11-17"}
{"start": "2026-10-06T07:00Z", "end": "2026-10-06T17:15Z", "family": "Thermal displacement", "description": "Warming of the day: the corr_y of the bridge targets sinks throughout the day (mostly PBJ_C, BJ_G, BJ_C, PM_D), the corr_x of most rises then goes back down in the afternoon; the camera pose follows the cycle. References stable, ordinary error_value of the targets. Deduced from the curves and the camera housing temperature, which rises during the day. The bridge expands and the camera, fixed to it, moves with it: normal, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-06T17:15Z", "end": "2026-10-07T06:30Z", "family": "Thermal displacement", "description": "Cooling of the night: the corr_y of the bridge targets rises steadily from late afternoon to morning, the camera tilt follows. Deduced from the curves and the camera housing temperature, which drops: the bridge rises as it cools. Normal, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-07T06:30Z", "end": "2026-10-07T12:15Z", "family": "Thermal displacement", "description": "Weak warming in the morning: the corr_y of the bridge targets goes down a little, much less than on other days; the camera housing temperature stays almost flat (overcast day). From late morning, the drop in visibility is mixed in and makes reading difficult. Normal, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-07T08:30Z", "end": "2026-10-08T16:00Z", "family": "Visibility", "description": "Visibility drops over the whole scene: the error_value of almost all the targets and of the three references (REF_G above all, but under its threshold) rises clearly, PM_C is rejected over long ranges and disappears from the curves, and the corrections of most targets become agitated, with common jumps of several targets (BJ_G, BL_C, BL_G, PBJ_C in the lead) that are not movements. Images: gray and dull scene, wet road on the 16:00 image, nothing in front of the targets. Cause deduced from the weather: the nearby MeteoSwiss station measures rain in the afternoon and the night of 07/10, heavy rain with strong gusts of wind in the second half of the night and the morning of 08/10, showers until the afternoon of 08/10; the end of the range comes with the drop of its humidity; according to the expert, nothing clear on the images, perhaps wind. The thermal cycle of the bridge partly fades out. Do not trust the curves over the range.", "review": "2026-11-18"}
{"start": "2026-10-08T14:30Z", "end": "2026-10-09T06:30Z", "family": "Thermal displacement", "description": "Cooling: the corr_y of the bridge targets rises steadily from the afternoon to the morning, without clear warming the day before; the camera housing temperature drops in the late afternoon. Deduced from the curves and the temperature: the bridge rises as it cools. Normal, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-09T00:45Z", "end": "2026-10-09T01:15Z", "family": "Perturbation", "description": "At night, for the duration of one measurement, the corr_x of most targets shift a little together (BJ_D clearly, PM_D, BJ_C, BL_D, PBL_D less), then come back at the next one; the corrections of the references REF_CT and REF_D move apart in opposite directions and the camera scale jumps. On the raw positions, only REF_D shifts, the targets do not move in the image; its error_value rises only slightly, all three references retained: the base of the compensation changes for one measurement. Thumbnail of 01:00: spot of REF_D unchanged, nothing in front. Cause not established, same signature as on the evening of 04/10. It is not a movement of the structure: point to ignore.", "review": "2026-11-18"}
{"start": "2026-10-09T06:30Z", "end": "2026-10-09T18:30Z", "family": "Thermal displacement", "description": "Warming of the day: the corr_y of the bridge targets sinks from morning to evening, the corr_x rises in the early afternoon then returns; the camera pose follows. References stable, ordinary error_value. Deduced from the curves and the camera housing temperature, which rises. Normal, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-09T11:45Z", "end": "2026-10-09T12:15Z", "family": "No data", "description": "One measurement is missing for all sensors, and the image of that moment too; the station nevertheless synchronizes at that moment and its voltage is normal (metrics): it is running, the measurement is not made or not recorded; only station affected that day at that hour, cause not established. The curves resume at the next measurement: nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-09T18:30Z", "end": "2026-10-10T08:30Z", "family": "Thermal displacement", "description": "Cooling of the night: the corr_y of the bridge targets rises until morning, the camera tilt follows. Deduced from the curves and the camera housing temperature, which drops. Normal, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-10T08:30Z", "end": "2026-10-10T16:15Z", "family": "Thermal displacement", "description": "Warming of the day: the corr_y of the bridge targets goes down until late afternoon; references stable, ordinary error_value; the camera pose follows the cycle. Deduced from the curves and the camera housing temperature. Normal, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-10T10:30Z", "end": "2026-10-10T11:00Z", "family": "No data", "description": "One measurement is missing for all sensors, and the image of that moment too; the station nevertheless synchronizes at that moment and its voltage is normal (metrics): it is running, the measurement is not made or not recorded; only station affected that day at that hour, cause not established. The curves resume at the next measurement: nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-10T12:15Z", "end": "2026-10-10T13:30Z", "family": "Visibility", "description": "Brief drop in visibility in the early afternoon, on a windy day: the error_value of almost all the targets rises from 12:30 (BL_G, PBL_C, BL_C and PM_C the most), then comes back by 13:30; the corrections become agitated: the corr_y of BJ_C and BJ_G drops sharply at 12:45, the corr_x of BJ_G, PBJ_C, BJ_C and BL_G go down at 13:00 and 13:15, then all come back; the camera pose jumps from one measurement to the next. Thumbnails: the spots are smaller from 12:45 to 13:15 than at 12:15 and 13:45, nothing in front; 13:00 image: trees blurred by the wind, sun on the slopes, road dry. The nearby MeteoSwiss station measures strong gusts and a trace of rain at that hour. Cause not established: a change of light or a passing shower, in the wind. This is not a movement: points not to be trusted.", "review": "2026-11-18"}