- 32 analyses: each label kept, rewritten or removed by its analyst (section Requalification of the report; mm magnitudes where the targets have them) - SNCF01 x3, WILDSTRUBEL 2026-09-01 -> 2026-10-06 x3: verified from their existing labels under the new rules - long labels (no analysis): auto/analyses/long-labels/<STATION>/; NORDEND-169 and -195 run to 07/11, so NORDEND-283 and -284 (their continuation) are removed - reading-rules.md, stations.md: the citations of removed or rewritten labels point to their successor, or to [expert] Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
7.6 KiB
NORDEND: the labels of 24 October to 7 November, kept to what stands out from the noise
You asked to requalify the labels of 24/10 16:30 → 07/11 14:00 (UTC) under the new rules: only what stands out from the noise of the corrected curves is labelled.
In short
28 labels stay, 8 are removed: single missed points that moved nothing else, a jolt too small to stand out, and one thermal day the correction absorbed. The curves can't be trusted during the rain, the fog, the low sun, the nights when the cobweb covers reference CTR03, or around midday on most sunny days. PR09, PR10, PR11 and PR17 stay offset by a few mm after the rain. No real movement of the quarry is seen.
Requalification
Kept: 26 unchanged. Rewritten: 2. Removed: 8. The deviation of a target is counted in its own noise; the threshold is 5.
- NORDEND-281 (28/10 11:45, PR04 missed once): removed. Only a missing point, on a target that doesn't enter the correction. The small dip of other curves at that time belongs to the thermal cycle of the day.
- NORDEND-286 (02/11, thermal cycle): removed. The correction absorbs it: no target goes beyond 4.9 noises from its night level.
- NORDEND-289 (03/11 13:30, camera jolt): removed. At most 3.6 noises (PR01, vertical).
- NORDEND-232 (05/11 morning, PR09 rejected at times): removed. Only missing points, and PR09's kept points stay within 3.9 noises. The spike at 03:30 keeps its own label (CTR03).
- NORDEND-235, NORDEND-238, NORDEND-241, NORDEND-242 (05/11 15:00 PR09, 06/11 09:30 PR10, 07/11 11:30 PR04, 07/11 14:00 PR07): removed. Each is a single missing point; no target moves beyond 5 noises.
- NORDEND-218 (26/10) and NORDEND-220 (27/10), thermal cycles: rewritten. Their text said the correction absorbs the movement, but the corrected curves keep it: PR18 horizontal at −7 and −10 noises, PR10 vertical at −9 noises on 27/10.
What happened
Rain, then fog, then low sun (24–25/10, 27–28/10, 30/10). On the night of 24 to 25 October, rain drops on the window hide most targets and the three references in turn. The remaining curves jump by up to about 40 mm (PR18 vertical). On the morning of 28 October, fog makes the correction fail for one measurement at 07:15: about 30 to 40 mm on many targets. On 30 October around 09:30, a low sun leaves the quarry in shadow: about 25 mm. Confirmed on the images.
Drop marks left on the window (from 25/10 to the end). After the rain, marks stay on the window near PR09, PR10, PR11 and the reference CTR02. These three targets have stayed offset ever since, by about 3 to 4 mm (PR09 horizontal, PR10 vertical), 10 to 13 times their noise. PR17 keeps the offset left by an older mark in front of it: about 2 mm horizontal against early October, about 6 mm vertical against September. Marks seen on the night images; that they cause the offsets is likely.
The daily thermal cycle of the camera (every day except 2 November). The camera turns a little each morning as its housing warms, and comes back in the evening. The correction absorbs most of it, not all: around midday the targets on the right edge drift, mostly PR18 (116 m away), by about 2 to 4 mm horizontally. That is 7 to 16 times its noise. From 1 to 3 November the housing stayed warm at night and the camera did not come back until the evening of the 3rd. Confirmed thermal: the camera follows the housing temperature. Why the nights stayed warm is unknown: there is no weather record for this station.
Top panels: the pan and the tilt stay on a plateau from the 1st to the 3rd instead of making a daily wave.
The cobweb (2–7 November). Threads of a web in front of the lens, lit by the infrared, cross the group of targets every night. On the night of 2 to 3 November, a knot sits on PR07 and PR08: PR07's kept points slide by about 2 mm, PR08's by about 1 mm. On 5, 6 and 7 November, a thread covers reference CTR03. Each time it is lost, the correction runs on two references and almost all curves jump together for that measurement: about 7 to 8 mm vertically on PR17 and PR18. Confirmed on the images.
The bright lines are the web threads; the knot at the bottom of the group of dots sits on PR07 and PR08.
Other moments. At 12:00 on 5 November, a one-measurement jolt of the camera leaves a dip of about 2 mm on several curves (PR01, PR10). The cause is not established. CTR01, the local reference read as a target, is rejected two times out of three, every day. Three short gaps (26, 27 and 29 October) have no measurement at all. Other stations had the same gaps, so the cause was in the transmission, not the station.
What to do
Clean the window: the drop marks, the mark in front of PR17 and the cobweb are all on it. Check CTR01 (its spot is barely visible by day). Nothing to do for the camera movements.
Not established
- Why the housing stayed warm at night from 1 to 3 November: daytime images or a weather record would tell whether warm air or cloud was there.
- Whether PR17's present level is still the mark or a return: a check of the prism and a clean window would settle it.
Labels
| Start (UTC) | End (UTC) | Family | Targets | In a few words |
|---|---|---|---|---|
| 24/10 16:30 | 25/10 09:00 | Visibility | almost all, CTR02–04 | night of rain |
| 25/10 05:45 | 07/11 14:00 | Visibility | PR09, PR10, PR11 | drop marks on the window, lasting offsets |
| 25/10 07:30 | 26/10 07:15 | Thermal displacement | PR01, PR12, PR18 | weak camera cycle |
| 26/10 07:15 | 27/10 06:30 | Thermal displacement | PR18, PR17 | weak camera cycle, no return at night (rewritten) |
| 26/10 14:15 | 26/10 15:00 | No data | all | common gap |
| 27/10 06:30 | 27/10 16:30 | Thermal displacement | PR18, PR10, PR13 | camera cycle (rewritten) |
| 27/10 08:45 | 27/10 09:15 | No data | all | common gap |
| 27/10 16:30 | 28/10 09:15 | Visibility | most, references | degrading night, fog |
| 28/10 09:15 | 29/10 06:45 | Thermal displacement | PR18, PR15–17 | camera cycle |
| 29/10 06:45 | 30/10 07:45 | Thermal displacement | PR18, PR16, PR10 | camera cycle |
| 29/10 14:45 | 29/10 15:15 | No data | all | common gap |
| 30/10 07:45 | 31/10 07:45 | Thermal displacement | PR18, PR16, PR10 | camera cycle |
| 30/10 08:45 | 30/10 10:45 | Visibility | most, CTR02, CTR03 | low sun |
| 31/10 07:45 | 01/11 06:00 | Thermal displacement | PR18, PR16, PR10 | camera cycle |
| 01/11 00:00 | 07/11 14:00 | Target issue | CTR01 | rejected two times out of three (now carried by NORDEND-195, extended to 07/11) |
| 01/11 00:00 | 07/11 14:00 | Obstruction | PR17 | window mark, lasting offset (now carried by NORDEND-169, extended to 07/11) |
| 01/11 06:00 | 02/11 06:30 | Thermal displacement | PR18, PR13 | camera turned, no return at night |
| 02/11 19:15 | 03/11 06:00 | Obstruction | PR07, PR08 | cobweb thread |
| 03/11 07:00 | 03/11 23:00 | Thermal displacement | PR10, PR01–PR12 | camera comes back as the housing cools |
| 03/11 23:00 | 05/11 06:30 | Thermal displacement | PR17, PR18 | camera cycle of 04/11 |
| 05/11 00:45 | 05/11 01:30 | Obstruction | CTR03, all | cobweb on a reference |
| 05/11 03:15 | 05/11 03:45 | Obstruction | CTR03, all | cobweb on a reference |
| 05/11 06:30 | 06/11 07:00 | Thermal displacement | PR18, PR17 | camera cycle |
| 05/11 11:45 | 05/11 12:15 | Displacement | PR01, PR10 | camera jolt |
| 05/11 23:00 | 06/11 10:00 | Obstruction | CTR03, all | cobweb on a reference |
| 06/11 07:00 | 07/11 06:30 | Thermal displacement | PR18, PR16 | camera cycle |
| 06/11 21:15 | 07/11 11:00 | Obstruction | CTR03, all | cobweb on a reference |
| 07/11 06:30 | 07/11 14:00 | Thermal displacement | PR18, PR06 | camera cycle |