- 32 analyses: each label kept, rewritten or removed by its analyst (section Requalification of the report; mm magnitudes where the targets have them) - SNCF01 x3, WILDSTRUBEL 2026-09-01 -> 2026-10-06 x3: verified from their existing labels under the new rules - long labels (no analysis): auto/analyses/long-labels/<STATION>/; NORDEND-169 and -195 run to 07/11, so NORDEND-283 and -284 (their continuation) are removed - reading-rules.md, stations.md: the citations of removed or rewritten labels point to their successor, or to [expert] Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
29 lines
22 KiB
JSON
29 lines
22 KiB
JSON
{"start": "2026-10-04T08:45Z", "end": "2026-10-04T16:30Z", "family": "Visibility", "description": "By day (04/10), sunny day (cast shadows on the wall on the image of 12:00): the corrected curves of the low targets fluctuate from one measurement to the next beyond their noise, mostly CV.4 (corr_x and corr_y), F4.2, BG.2, BG.3, with one-measurement jumps that come back at once; late in the morning, BG.3, F4.2, BG.2 and the P targets jump together in corr_x for one measurement; CV.2 and CV.4 are rejected at times (missing points). At night everything is calm again. Deduced cause: heat shimmer, the air heated by the sun above the tracks and the ballast, which makes the spots tremble (a fast noise, by day only, with the recognition error of these low targets rising), nothing in front of the targets on the images. Do not trust the small movements of these curves over the range; this is not a movement of the structure."}
|
|
{"start": "2026-10-04T09:00Z", "end": "2026-10-05T06:30Z", "family": "Thermal displacement", "description": "Daytime thermal cycle (04/10): from the morning, the pan and the tilt of the camera drop and its scale rises, then they slowly come back in the afternoon, the evening and all night, until the start of the next morning. The corrected curves follow the same cycle, poorly compensated: corr_x of P7, P5, P6 and corr_y of P5, P6, P7, P4 move away from their night level during the day then come back, partly all at once at nightfall, when the recognition error also comes back (the lighting plays a part). Deduced cause: the camera and its mount move with the heat of the day (camera pose); the structure, a masonry wall, is not supposed to move like that. No temperature is available to confirm it. Normal, nothing to do.", "review": "2026-11-17"}
|
|
{"start": "2026-10-05T06:30Z", "end": "2026-10-06T07:15Z", "family": "Thermal displacement", "description": "Daytime thermal cycle (05/10): from the morning, the pan and the tilt of the camera drop and its scale rises, then they slowly come back in the afternoon, the evening and all night, until the start of the next morning. The corrected curves follow the same cycle, poorly compensated: corr_x of P7, P5, P6 and corr_y of P5, P6, P7, P4 move away from their night level during the day then come back, partly all at once at nightfall, when the recognition error also comes back (the lighting plays a part). Deduced cause: the camera and its mount move with the heat of the day (camera pose); the structure, a masonry wall, is not supposed to move like that. No temperature is available to confirm it. Normal, nothing to do.", "review": "2026-11-17"}
|
|
{"start": "2026-10-05T07:00Z", "end": "2026-10-05T15:15Z", "family": "Visibility", "description": "By day (05/10), sunny day (cast shadows on the image of 12:00): the corrected curves of the low targets fluctuate from one measurement to the next beyond their noise, the most strongly of the batch: CV.4 and CV.2 in both columns, F4.2, BG.3, and in late morning the corr_y of P1, P2, P3 jump together for one or two measurements; CV.2, CV.4 and F4.2 are rejected at times (missing points). Calm again before nightfall; the train of 16:00 is labelled apart. Deduced cause: heat shimmer, the air heated by the sun above the tracks and the ballast, which makes the spots tremble (a fast noise, by day only, with the recognition error of these low targets rising), nothing in front of the targets on the images. Do not trust the small movements of these curves over the range; this is not a movement of the structure."}
|
|
{"start": "2026-10-05T15:45Z", "end": "2026-10-05T16:15Z", "family": "Obstruction", "description": "One single measurement: most targets (the CV, the F4 and some of the P) are rejected and their curves are missing; the references are affected too (BG.3.1 and R1 rejected), the compensation retains none of them, and the targets that stayed under the threshold (BG.2, BG.3, F4.5 and some P) jump in corr_x and corr_y for the time of the measurement. Everything comes back at the next measurement. Cause: a passage in front of the targets and the references, a train passing, blurred, in front of the wall and the targets, seen on the 16:00 image. The structure is not moving: point to ignore, nothing to do.", "review": "2026-11-17"}
|
|
{"start": "2026-10-06T07:00Z", "end": "2026-10-06T13:15Z", "family": "Visibility", "description": "By day (06/10), sunny morning (cast shadows on the image of 12:00): the corrected curves of the low targets fluctuate beyond their noise, mostly CV.4 in corr_x, F4.2 in both columns and CV.2, with one-measurement jumps that come back at once; CV.2 and CV.4 are rejected at times (missing points). The other targets stay within their noise; calm again from early afternoon. Deduced cause: heat shimmer, the air heated by the sun above the tracks and the ballast, which makes the spots tremble (a fast noise, by day only, with the recognition error of these low targets rising), nothing in front of the targets on the images. Do not trust the small movements of these curves over the range; this is not a movement of the structure."}
|
|
{"start": "2026-10-06T07:15Z", "end": "2026-10-07T03:00Z", "family": "Thermal displacement", "description": "Daytime thermal cycle (06/10), sunny day (cast shadows on the image of 12:00): from the morning, the pan and the tilt of the camera drop strongly and its scale rises, until early afternoon; they come back slowly in the afternoon, the evening and the first half of the night. The compensation absorbs only part of it: corr_x of P7 rises clearly, with corr_y of P6 and P7, while corr_x of P1 drops and that of P5 rises; the curves come back to their night level late in the evening, the pose in the night. Deduced cause: the camera and its mount move with the heat of the day (camera pose); the structure, a masonry wall, is not supposed to move like that. No temperature is available to confirm it. Normal, nothing to do."}
|
|
{"start": "2026-10-07T07:30Z", "end": "2026-10-08T04:15Z", "family": "Thermal displacement", "description": "Weak daytime thermal cycle (07/10), overcast day (image of 12:00): in the morning, the pan and the tilt of the camera drop a little and its scale rises a little, then the camera stays in that position all afternoon; it comes back in the evening and all night, beyond its position of the previous night, until early on the 8th. The corrected curves follow, less than on the sunny days: corr_x of P5 and P7 rises, corr_y of P7 and P6 too, corr_x of P1 drops; P7 comes back late in the evening, P5 only after midnight. The three train passages of the day (13:00, 16:00, 19:45) are labelled apart. Deduced cause: the camera and its mount move with the heat of the day (camera pose); the structure, a masonry wall, is not supposed to move like that. No temperature is available to confirm it. Normal, nothing to do."}
|
|
{"start": "2026-10-07T12:45Z", "end": "2026-10-07T13:15Z", "family": "Obstruction", "description": "One single measurement: most targets (the CV, the F4 except F4.5 and F4.6, and all the P) are rejected and their curves are missing; the references are affected too (R1 rejected, BG.3.1 just under its threshold and left out), the compensation retains none of them; the targets that stayed under the threshold jump a little beyond their noise, BG.3 in corr_x, F4.5 and F4.6 in corr_y. Everything comes back at the next measurement. Cause seen: a train passing in front of the wall and the targets, blurred, on the image of 13:00. The structure is not moving: point to ignore, nothing to do."}
|
|
{"start": "2026-10-07T15:45Z", "end": "2026-10-07T16:15Z", "family": "Obstruction", "description": "One single measurement: most targets (the CV, the F4 and some of the P) are rejected and their curves are missing; the references are affected too (BG.3.1 and R1 rejected), the compensation retains none of them, and the targets that stayed under the threshold (BG.2, BG.3, F4.5 and some P) jump in corr_x and corr_y for the time of the measurement. Everything comes back at the next measurement. Cause: a passage in front of the targets and the references, a train passing in front of the targets, seen on the 16:00 image. The structure is not moving: point to ignore, nothing to do.", "review": "2026-11-17"}
|
|
{"start": "2026-10-07T19:30Z", "end": "2026-10-07T20:00Z", "family": "Obstruction", "description": "One single measurement: most targets (the CV, the F4 and some of the P) are rejected and their curves are missing; the references are affected too (BG.3.1 rejected), the compensation retains none of them, and the targets that stayed under the threshold (BG.2, BG.3, F4.5 and some P) jump in corr_x and corr_y for the time of the measurement. Everything comes back at the next measurement. Cause: a passage in front of the targets and the references, no image at that moment; deduced from the signature, the same as that of the trains seen on the images of the other passages. The structure is not moving: point to ignore, nothing to do.", "review": "2026-11-17"}
|
|
{"start": "2026-10-08T06:45Z", "end": "2026-10-08T16:30Z", "family": "Visibility", "description": "By day (08/10): the corrected curves of all targets fluctuate much more than at night, from one measurement to the next, especially CV.2, CV.4, F4.2, BG.3, CV.6, CV.9, with one-measurement jumps that come back at once, and CV.2, CV.4 (sometimes F4.2) are rejected at times, their curves having gaps; their recognition error varies strongly by day. At night everything becomes calm again. Deduced cause: heat shimmer from the air heated above the tracks (a fast noise over the whole scene, by day only), not visible on the images; the rejections of CV.2 and CV.4, low targets, may also come from passages, not seen. Do not trust the small movements of these curves by day; this is not a movement of the structure.", "review": "2026-11-17"}
|
|
{"start": "2026-10-08T08:15Z", "end": "2026-10-09T04:30Z", "family": "Thermal displacement", "description": "Daytime thermal cycle (08/10), weak by day and prolonged at night: from the morning, the pan and the tilt of the camera drop a little and its scale rises; in the evening, the camera rises beyond its position of the previous night and comes back to it only on the morning of the 9th. The corrected curves follow, poorly compensated: corr_y of P5, P6, P7, P4 moves away from its night level during the day; in the evening and at night, corr_x of P1, P5, P6, P7 exceeds its level of the previous night in the other direction, until the morning of the 9th. Deduced cause: the camera and its mount move with the heat of the day (camera pose); the structure, a masonry wall, is not supposed to move like that. No temperature is available to confirm it. Normal, nothing to do.", "review": "2026-11-17"}
|
|
{"start": "2026-10-09T01:45Z", "end": "2026-10-09T02:15Z", "family": "No data", "description": "One measurement is missing, for all sensors, around two in the morning: all curves have a gap; no image at that moment. The power metrics of the station are empty over the whole month. This one-measurement night gap, around 02:00 UTC, falls at the same measurement on FLORIDA and SNCF01 on 09, 14 and 15/10, and only on them; other stations have the same night gap around the same hour on other weeks (JUNGFRAU and NORDEND in early September): a common cause outside the station, at night, is probable; it is not established. Nothing to do on the station if it does not get worse.", "review": "2026-11-17"}
|
|
{"start": "2026-10-09T07:00Z", "end": "2026-10-10T06:00Z", "family": "Thermal displacement", "description": "Daytime thermal cycle (09/10), with no return in the evening: in the morning, the pan and the tilt of the camera drop and its scale rises, then the camera stays in that position all afternoon and evening; it comes back only slowly during the night, on the morning of the 10th. The corrected curves follow, poorly compensated: corr_x of P1, P2, P5, P6, P7 moves away from its night level during the day, stays away in the evening and comes back only on the morning of the 10th. Deduced cause: the camera and its mount move with the heat of the day (camera pose); the structure, a masonry wall, is not supposed to move like that. No temperature is available to confirm it. Normal, nothing to do.", "review": "2026-11-17"}
|
|
{"start": "2026-10-10T01:45Z", "end": "2026-10-10T02:15Z", "family": "No data", "description": "One measurement is missing, for all sensors, around two in the morning: all curves have a gap; the image of that moment exists nonetheless. The power metrics of the station are empty over the whole month. This one-measurement night gap, around 02:00 UTC, falls at the same measurement on FLORIDA and SNCF01 on 09, 14 and 15/10, and only on them (that night, on SNCF01 alone); other stations have the same night gap around the same hour on other weeks (JUNGFRAU and NORDEND in early September): a common cause outside the station, at night, is probable; it is not established. Nothing to do on the station if it does not get worse.", "review": "2026-11-17"}
|
|
{"start": "2026-10-10T07:00Z", "end": "2026-10-11T08:30Z", "family": "Thermal displacement", "description": "Daytime thermal cycle (10/10): from the morning, the pan and the tilt of the camera drop and its scale rises, then they slowly come back in the afternoon, the evening and all night, until the start of the next morning. The corrected curves follow the same cycle, poorly compensated: corr_x of P7, P5, P6 and corr_y of P5, P6, P7, P4 move away from their night level during the day then come back, partly all at once at nightfall, when the recognition error also comes back (the lighting plays a part). Deduced cause: the camera and its mount move with the heat of the day (camera pose); the structure, a masonry wall, is not supposed to move like that. No temperature is available to confirm it. Normal, nothing to do.", "review": "2026-11-17"}
|
|
{"start": "2026-10-10T07:00Z", "end": "2026-10-10T13:00Z", "family": "Visibility", "description": "By day (10/10), sunny morning (cast shadows on the image of 12:00): the corrected curves of the low targets fluctuate beyond their noise, mostly CV.4 in both columns, CV.9 and CV.2 in corr_y, F4.2 and F4.5, and in mid-morning BG.3, P2, P3 jump together in corr_x for one measurement; they come back at once. Calm again from early afternoon. Deduced cause: heat shimmer, the air heated by the sun above the tracks and the ballast, which makes the spots tremble (a fast noise, by day only, with the recognition error of these low targets rising), nothing in front of the targets on the images. Do not trust the small movements of these curves over the range; this is not a movement of the structure."}
|
|
{"start": "2026-10-11T10:00Z", "end": "2026-10-11T15:30Z", "family": "Visibility", "description": "By day (11/10), overcast day (image of 12:00), the weakest agitation of the batch that still crosses the noise: CV.4 in corr_y, F4.2, CV.2, and P1, P2 in corr_y make a few one-measurement jumps just beyond their noise, coming back at once; the train of 14:15 is labelled apart. Calm at night. Deduced cause: a weak shimmer of the air above the tracks by day, the same signature as on the sunny days, much weaker; nothing in front of the targets on the images. Do not trust the small movements of these curves over the range; this is not a movement of the structure."}
|
|
{"start": "2026-10-11T08:30Z", "end": "2026-10-12T02:45Z", "family": "Thermal displacement", "description": "Daytime thermal cycle (11/10), overcast day (image of 12:00): from the morning, the pan and the tilt of the camera drop and its scale rises, until early afternoon; they come back in the late afternoon, the evening and the first half of the night, beyond their position of the previous night. The compensation absorbs part of it: corr_x of P7 rises clearly, with corr_y of P6 and P5, while corr_x of P1 drops; the curves are back at their night level in the evening, the pose in the night. The train of 14:15 is labelled apart. Deduced cause: the camera and its mount move with the heat of the day (camera pose); the structure, a masonry wall, is not supposed to move like that. No temperature is available to confirm it. Normal, nothing to do."}
|
|
{"start": "2026-10-11T14:00Z", "end": "2026-10-11T14:30Z", "family": "Obstruction", "description": "One single measurement: most targets (the CV, the F4 and all the P) are rejected and their curves are missing; the references are affected too (BG.3.1 and R1 rejected), the compensation retains none of them, and the targets that stayed under the threshold, BG.2, BG.3 and F4.5, jump strongly in corr_x and corr_y for the time of the measurement. Everything comes back at the next measurement. Cause: a passage in front of the targets and the references; the camera takes its image on the hour, none at that measurement; deduced from the signature, the same as that of the trains seen on the images of the other passages. The structure is not moving: point to ignore, nothing to do."}
|
|
{"start": "2026-10-12T06:30Z", "end": "2026-10-12T07:00Z", "family": "Obstruction", "description": "One single measurement, early in the morning: CV.8 and F4.2 go above their threshold (CV.6 too), their curves are missing, and the recognition error of most CV and F4 targets and of the reference BG.3.1 rises; CV.4, left under its threshold with its recognition error dropping, jumps clearly in corr_x for that measurement, and comes back at the next one. The references hold, the other targets stay within their noise. Cause deduced from the signature: a partial passage in front of the low targets, CV.4 latching onto a light or a reflection; no image at that measurement (the camera takes one on the hour). The structure is not moving: point to ignore, nothing to do."}
|
|
{"start": "2026-10-12T07:30Z", "end": "2026-10-12T14:45Z", "family": "Visibility", "description": "By day (12/10), sunny day (cast shadows on the image of 12:00): the corrected curves of the low targets fluctuate beyond their noise, mostly CV.4 in both columns, F4.2, CV.2, F4.5, F4.6, and in mid-morning BG.3, F4.2, F4.6, P2, P3, P4, P6 jump together in corr_x for one measurement; they come back at once; CV.2 and CV.4 are rejected at times (missing points). Calm again in the afternoon. Deduced cause: heat shimmer, the air heated by the sun above the tracks and the ballast, which makes the spots tremble (a fast noise, by day only, with the recognition error of these low targets rising), nothing in front of the targets on the images. Do not trust the small movements of these curves over the range; this is not a movement of the structure."}
|
|
{"start": "2026-10-12T08:00Z", "end": "2026-10-14T04:00Z", "family": "Thermal displacement", "description": "Thermal cycle of 12 and 13/10, as one single episode: on the 12th, from the morning, the pan and the tilt of the camera drop and its scale rises; during the night from 12 to 13, the camera comes back only in part, and the corrected curves do not come back: corr_x of P1, P5, P6, P7 and corr_y of P4, P5, P6, P7 stay away from their night level all night, while the recognition error of the P rises a little; on the 13th, a second daytime dip is added to it, then everything comes back on the evening of the 13th and during the night, on the morning of the 14th. Deduced cause: the camera and its mount move with the heat of the day (camera pose); the night without return is not explained, no temperature being available. Nothing to do.", "review": "2026-11-17"}
|
|
{"start": "2026-10-12T15:45Z", "end": "2026-10-12T16:15Z", "family": "Obstruction", "description": "One single measurement: most targets (the CV, the F4 and all the P) are rejected and their curves are missing; the references are affected too (BG.3.1 and R1 rejected), the compensation retains none of them, and the targets that stayed under the threshold, BG.2, BG.3 and F4.5, jump strongly in corr_x and corr_y for the time of the measurement. Everything comes back at the next measurement. Cause seen: a train passing in front of the wall and the targets, blurred, on the image of 16:00. The structure is not moving: point to ignore, nothing to do."}
|
|
{"start": "2026-10-13T01:45Z", "end": "2026-10-13T02:15Z", "family": "No data", "description": "One measurement is missing, for all sensors, around two in the morning: all curves have a gap; no image at that moment. The power metrics of the station are empty over the whole month. This one-measurement night gap, around 02:00 UTC, falls at the same measurement on FLORIDA and SNCF01 on 09, 14 and 15/10, and only on them (that night, on SNCF01 alone); other stations have the same night gap around the same hour on other weeks (JUNGFRAU and NORDEND in early September): a common cause outside the station, at night, is probable; it is not established. Nothing to do on the station if it does not get worse.", "review": "2026-11-17"}
|
|
{"start": "2026-10-13T07:45Z", "end": "2026-10-13T14:00Z", "family": "Visibility", "description": "By day (13/10), sun and clouds (image of 12:00): the corrected curves of the low targets fluctuate beyond their noise, mostly CV.4 in corr_x, F4.2, F4.6, CV.2, and around midday P1, P2 and F4.2 jump together in corr_x for one measurement; they come back at once. Calm again in the afternoon. Deduced cause: heat shimmer, the air heated by the sun above the tracks and the ballast, which makes the spots tremble (a fast noise, by day only, with the recognition error of these low targets rising), nothing in front of the targets on the images. Do not trust the small movements of these curves over the range; this is not a movement of the structure."}
|
|
{"start": "2026-10-14T01:15Z", "end": "2026-10-14T01:45Z", "family": "No data", "description": "One measurement is missing, for all sensors, around two in the morning: all curves have a gap. The power metrics of the station are empty over the whole month. This one-measurement night gap, around 02:00 UTC, falls at the same measurement on FLORIDA and SNCF01 on 09, 14 and 15/10, and only on them; other stations have the same night gap around the same hour on other weeks (JUNGFRAU and NORDEND in early September): a common cause outside the station, at night, is probable; it is not established. Nothing to do on the station if it does not get worse.", "review": "2026-11-17"}
|