{"start": "2026-10-01T09:45Z", "end": "2026-10-01T19:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day; the corr_x of Sellette 6, Massif 2 and Sellette 4 rises a little during the day, the corr_y of Sellette 6 too, and returns in the evening. Deduced: the camera movement follows the housing temperature, ordinary error_value outside the other episodes. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-17"}
|
|
{"start": "2026-10-01T20:30Z", "end": "2026-10-02T08:45Z", "family": "Visibility", "description": "Night of rain or mist: from 20:45 the error_value of all the targets and of both references rises together and the corrected curves of Sellette 4 and Sellette 5 already shift a little; from 21:00 p1_r (and its twin Sellette 3), Sellette 4 and Sellette 5 are rejected all night and the camera is no longer registered until the morning. From 21:00 to 22:30 the kept measurements of Massif 2 and Sellette 6 jump strongly downward in corr_y (compensation on r1_r alone); from 22:45 to about 02:00 almost all the sensors are rejected, then only rare points remain, still shifted. Seen on the 00:00 image: very weak spots, drops on the leaves in the foreground. Everything comes back in the morning, Sellette 4 last. The structure does not move: nothing to do, curves of the range to ignore.", "review": "2026-11-18"}
|
|
{"start": "2026-10-02T01:45Z", "end": "2026-10-02T02:15Z", "family": "No data", "description": "One measurement absent for all sensors, although the image of that moment exists; the station synchronizes at that moment and its voltage is normal: it is running, the measurement is missing; measurements resume at the next one. SNCF01 has no data yet that day. This one-measurement gap in the night, around 02:00 UTC, falls on the same measurement at FLORIDA and SNCF01 on 09, 14 and 15/10, and only on them; other stations have the same night gap around the same hour in other weeks (JUNGFRAU and NORDEND in early September): a common cause outside the station, at night, is probable; it is not established. Nothing to do on the station if it does not get worse.", "review": "2026-11-17"}
|
|
{"start": "2026-10-02T08:30Z", "end": "2026-10-02T09:45Z", "family": "Visibility", "description": "The morning after the rain, the reference r1_r, one of the only two references of the station, loses its light without being rejected: on the 09:00 thumbnail its spot is barely visible, much fainter than on the 11:00 thumbnail and than the 3rd at 09:00, nothing in front of it. Its measured position slides against the targets, the camera pose (pan, scale) goes off, and the compensation passes it into all the targets: the corr_x of Massif 2 and Sellette 5 rise, that of Sellette 4 drops, the corr_y of Sellette 6 drops, then everything comes back at 09:45. Deduced cause: a reference that loses its brightness after the rain, without obstacle. With two references, the slightest error of one passes into all the points: points to ignore; this is not a movement.", "review": "2026-11-18"}
|
|
{"start": "2026-10-02T09:45Z", "end": "2026-10-02T10:30Z", "family": "Visibility", "description": "r1_r, one of the only two references of the station, sees its error_value rise above the threshold for two measurements, in the morning: it is rejected and the camera is no longer registered. The corrected curves are then computed on p1_r alone: the corr_x of Massif 2, Sellette 4 and Sellette 5, and the corr_y of Massif 2 and Sellette 5, jump a little and return at the next registration. Pont Ernen, the twin of r1_r, is rejected with it. Raw positions of the targets without a step. Seen on the 10:00 thumbnail: the background behind r1_r, a tiny spot, is in full sun and its spot drowns in it; the same sunlit background comes back on the other sunny mornings at that hour. Not a movement: data of the range not to be trusted, nothing to do on the structure.", "review": "2026-11-18"}
|
|
{"start": "2026-10-02T10:30Z", "end": "2026-10-02T11:00Z", "family": "Visibility", "description": "For one measurement in late morning, the error_value of the reference p1_r (and of its twin Sellette 3) rises clearly, under its threshold: the compensation, on two references only, is distorted and the corr_x of Sellette 4, Sellette 5 and Sellette 6 jump down together, then return at the next measurement; Massif 2 is rejected at the same instant (labeled separately). No image at that instant; the scene is in full daylight at 10:00 and 11:00. Cause not established, probably the morning light on the reference. Not a movement: points to ignore.", "review": "2026-11-18"}
|
|
{"start": "2026-10-02T10:45Z", "end": "2026-10-02T18:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day; the corr_x of Sellette 6, Massif 2 and Sellette 4 rises a little during the day and returns in the evening. Deduced: the camera movement follows the housing temperature, ordinary error_value outside the other episodes. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-17"}
|
|
{"start": "2026-10-02T18:00Z", "end": "2026-10-02T18:30Z", "family": "Visibility", "description": "At nightfall, Massif 2 alone keeps one measurement with its error_value just under the threshold, and its corr_y jumps clearly upward, then returns at the next measurement; the other targets do not move. On the 18:00 thumbnail its spot is as usual. Deduced cause: a weak spot at the change of light, as at its other isolated rejections before its Target issue (from the 6th, labeled separately). Point to ignore; this is not a movement.", "review": "2026-11-18"}
|
|
{"start": "2026-10-02T18:30Z", "end": "2026-10-02T23:30Z", "family": "Visibility", "description": "At the start of the night, the reference r1_r, one of the only two references of the station, weakens: on the thumbnails from 19:00 to 22:00 its spot is smaller than at 18:00 and 23:00, nothing in front. Its measured position slides against the targets and the camera pose follows it; the compensation passes it into the targets: the corr_x of Massif 2, Sellette 5 and Sellette 6 rise a little from 18:45 to 21:45. In the middle of it, the error_value of p1_r (and of its twin Sellette 3) rises for one measurement at 21:00, Sellette 4 jumps down; Massif 2 is rejected for two measurements, its curve is missing, and its corr_y stays low at the next one. Then p1_r flickers: at 22:30, 22:45 and 23:15 the corr_x of Sellette 4, Sellette 5 and Massif 2 drop together and come back at 23:30. Deduced cause: references that lose part of their light at night, without obstacle. Points to ignore; this is not a movement.", "review": "2026-11-18"}
|
|
{"start": "2026-10-03T08:45Z", "end": "2026-10-03T19:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day; the corr_x of Sellette 6, Massif 2 and Sellette 4 rises a little during the day, the corr_y of Sellette 4 goes down a little, and everything returns in the evening. Deduced: the camera movement follows the housing temperature, ordinary error_value outside the other episodes. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-17"}
|
|
{"start": "2026-10-04T08:30Z", "end": "2026-10-04T09:00Z", "family": "Perturbation", "description": "One-measurement jump of the corr_x of Sellette 5, Massif 2 and Sellette 6 (Sellette 4 a little), all downward, then back at the next measurement: in the raw image the targets do not move against each other, while the reference r1_r is measured slightly shifted alone for this measurement, without its error_value rising; the camera pose (tilt, scale) jumps with it and the compensation, on two references only, passes the jump into the targets. No image at that instant; on the 08:00 and 09:00 thumbnails r1_r looks as usual. Cause not established. Not a movement: points to ignore.", "review": "2026-11-18"}
|
|
{"start": "2026-10-04T11:45Z", "end": "2026-10-04T18:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day; the corr_x of Sellette 6, Massif 2 and Sellette 4 rises a little during the day, the corr_y of Sellette 4 goes down a little, and everything returns in the evening. Deduced: the camera movement follows the housing temperature, ordinary error_value outside the other episodes. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-17"}
|
|
{"start": "2026-10-05T07:45Z", "end": "2026-10-05T19:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day; the corr_x of Sellette 6, Massif 2 and Sellette 4 rises a little during the day, the corr_y of Sellette 4 goes down a little, and everything returns in the evening. Deduced: the camera movement follows the housing temperature, ordinary error_value outside the other episodes. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-17"}
|
|
{"start": "2026-10-06T09:45Z", "end": "2026-10-06T22:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day; the corr_x of Sellette 6 rises during the day, that of Sellette 5 and the corr_y of Sellette 4 go down a little, and everything returns in the evening. Deduced: the camera movement follows the housing temperature, ordinary error_value outside the other episodes. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-17"}
|
|
{"start": "2026-10-07T08:45Z", "end": "2026-10-07T20:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day. Most of it is absorbed by the compensation, but not all: the corr_y of Sellette 6 rises clearly above its night level in the afternoon and comes back in the evening, and the corr_y of Massif 2 dips around midday; the other targets stay close to their night level. Deduced: the camera movement follows the housing temperature, ordinary error_value. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-18"}
|
|
{"start": "2026-10-08T03:15Z", "end": "2026-10-09T08:00Z", "family": "Visibility", "description": "Rainy day and damp night: the error_value of the targets and the references rises from 3h30, and the targets jump from that measurement; p1_r (and its twin Sellette 3) is rejected at times until the evening, Sellette 4 and Sellette 5 almost over the whole range, Massif 2 and Sellette 6 often. When p1_r is kept but poorly seen, the camera pose goes off (tilt, scale) and the corr of all the targets jumps strongly; when it is rejected, no more registration. Seen on the images: drops on the leaves at 05:00, scene veiled at 14:00, smaller spots. Back on the morning of the 9th. Not a movement: curves of the range to ignore.", "review": "2026-11-17"}
|
|
{"start": "2026-10-09T01:45Z", "end": "2026-10-09T02:15Z", "family": "No data", "description": "One measurement absent for all sensors, and no image at that moment; the station nevertheless synchronizes at that moment and its voltage is normal: it is running, the measurement is missing; measurements resume at the next one. This one-measurement gap in the night, around 02:00 UTC, falls on the same measurement at FLORIDA and SNCF01 on 09, 14 and 15/10, and only on them; other stations have the same night gap around the same hour in other weeks (JUNGFRAU and NORDEND in early September): a common cause outside the station, at night, is probable; it is not established. Nothing to do on the station if it does not get worse.", "review": "2026-11-17"}
|
|
{"start": "2026-10-09T08:00Z", "end": "2026-10-09T13:30Z", "family": "Perturbation", "description": "After the rain episode of the 8th, the corr_x of Sellette 5, already shifted upward at the end of the rain, and that of Sellette 4, which joins it in the early afternoon of the 9th, take a slightly higher level and stay there until the morning of the 15th (return labeled separately); at the same time the camera pose has changed level (tilt, scale) and the error_value of r1_r is lower than before the rain. A reference spot that changes appearance changes the basis; the housing temperature also drops on those days and rises again when the shift fades, but at equal temperature, on the 17th and 18th, Sellette 5 does not have this level: link not established. Cause not established. The shift fades on the morning of the 15th (return labelled separately): nothing to do, points to ignore."}
|
|
{"start": "2026-10-10T06:45Z", "end": "2026-10-10T20:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day. Apart from the p1_r episode of the morning (labeled separately), the corrected curves keep part of it: the corr_x of Sellette 6 and Massif 2 rise above their night level in the afternoon, then at the end of the day the corr_x of Sellette 5 and the corr_y of Sellette 6 go below it before returning to it in the night. Deduced: the camera movement follows the housing temperature, ordinary error_value outside the morning episode. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-18"}
|
|
{"start": "2026-10-10T07:15Z", "end": "2026-10-10T11:30Z", "family": "Visibility", "description": "In the morning, the error_value of p1_r rises from 7h30 and the corr_y of Sellette 4 and Sellette 5 shifts; then p1_r (and its twin Sellette 3) goes above the threshold and is rejected for several measurements, Sellette 5 and Sellette 6 too: the camera is no longer registered, and at the kept measurements the corr_x of Sellette 4 jumps clearly then returns. Thumbnails: the spot of p1_r has a wider halo at 09:00 than at 13:00, scene in full daylight without obstacle; probably the morning light, cause not established. Not a movement: curves of the range to ignore.", "review": "2026-11-17"}
|