- 32 analyses: each label kept, rewritten or removed by its analyst (section Requalification of the report; mm magnitudes where the targets have them) - SNCF01 x3, WILDSTRUBEL 2026-09-01 -> 2026-10-06 x3: verified from their existing labels under the new rules - long labels (no analysis): auto/analyses/long-labels/<STATION>/; NORDEND-169 and -195 run to 07/11, so NORDEND-283 and -284 (their continuation) are removed - reading-rules.md, stations.md: the citations of removed or rewritten labels point to their successor, or to [expert] Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
3 lines
3.7 KiB
JSON
3 lines
3.7 KiB
JSON
{"id": "BREITHORN-2", "start": "2026-10-03T00:00Z", "end": "2026-10-13T04:00Z", "family": "Displacement", "description": "From the start of the data to 13 October, six targets drift slowly and steadily, all in the same direction, mostly in corr_x, in corr_y too except POUI19: COLH20, COLI20, COLI21, COLJ19, POUI19 and POUI20; COLI24 drifts in the opposite direction in corr_y. Their drift follows the camera pose step by step, as the camera gradually tilts (tilt increasing, pan and rotation decreasing), while their position in the image hardly moves and their error_value stays stable; the other targets, such as POUH21, do not drift. Cause given by the expert: the camera is gradually nodding forward and the compensation of its movement is not complete, correcting some targets better than others. According to the expert, COLJ19 and POUI19, which drift the most, are much closer to the camera than the other targets; for the other drifting targets, the reason for their poorer compensation (position, angle) is not established. The temperature of the camera housing drops slightly over the range, link not established. According to the expert, BREITHORN, MICHIGAN and NEBRASKA are in the same building: the cameras of the three stations tilt together, in the same direction and on the same dates (advance until 12 October, stop and slight backward movement from 13 to 16, resumption from the 17th to the end of the month), which points to a cause common to the building rather than a fault of this camera alone; at equal housing temperature, the cameras are more tilted at the end of the month than in the middle: temperature does not explain it alone, link not established. For the customer: the targets do not move relative to each other, this is not a movement of the structure; the camera tilt is to be monitored.", "review": "2026-11-17"}
|
|
{"id": "BREITHORN-13", "start": "2026-10-16T20:00Z", "end": "2026-11-01T00:00Z", "family": "Displacement", "description": "From 17 October to the end of the batch, the drift resumes, faster than at the beginning of the month until the 25th, then clearly slower without stopping: the camera tilts again (tilt increasing, pan and rotation decreasing), and COLH20, COLI20, COLI21, COLJ19, POUI19 and POUI20 drift with it, mostly in corr_x and also in corr_y, POUI19 the most; COLI24 drifts in the opposite direction in corr_y. COLI22, COLH20''', POUI22 and POUI24 drift too, more noisily, between their own rejections. Their position in the image hardly moves, their error_value stays stable, POUH21 does not drift. Cause given by the expert: the camera is nodding forward and the compensation of its movement is not complete, correcting some targets better than others. According to the expert, COLJ19 and POUI19, which drift the most, are much closer to the camera than the other targets; for the other drifting targets, the reason for their poorer compensation (position, angle) is not established. The resumption coincides with the drop in the camera housing temperature, but the drift does not come back when it rises: link not established. According to the expert, BREITHORN, MICHIGAN and NEBRASKA are in the same building: the cameras of the three stations tilt together, in the same direction and on the same dates (advance until 12 October, stop and slight backward movement from 13 to 16, resumption from the 17th to the end of the month), which points to a cause common to the building rather than a fault of this camera alone; at equal housing temperature, the cameras are more tilted at the end of the month than in the middle: temperature does not explain it alone, link not established. For the customer: the targets do not move relative to each other, this is not a movement of the structure; the camera tilt is to be monitored."}
|