Files
aimsight-labeling/auto/analyses/long-labels/CLARIDEN/labels.jsonl
T
maximeandClaude Opus 5.5 ddb17c2189 auto: labels requalified under the 5-noise rules (only what stands out from the noise): 32 analyses refined, the 6 paused periods verified, the long labels requalified with the fixes the period analysts found; 1153 -> 961 labels
- 32 analyses: each label kept, rewritten or removed by its analyst (section Requalification of the report; mm magnitudes where the targets have them)
- SNCF01 x3, WILDSTRUBEL 2026-09-01 -> 2026-10-06 x3: verified from their existing labels under the new rules
- long labels (no analysis): auto/analyses/long-labels/<STATION>/; NORDEND-169 and -195 run to 07/11, so NORDEND-283 and -284 (their continuation) are removed
- reading-rules.md, stations.md: the citations of removed or rewritten labels point to their successor, or to [expert]

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-17 23:58:00 +01:00

3 lines
1.8 KiB
JSON

{"id": "CLARIDEN-1", "start": "2026-10-01T00:00Z", "end": "2026-11-01T00:00Z", "family": "Target issue", "description": "The target P-300-B is rejected at every measurement of the batch: its recognition error stays almost at 1, its corrected curve is missing over the whole month. This has lasted since 29 September in the late afternoon, the time when the recognition error of other targets, including its neighbor P-301-B, also changes level all at once: a station setting changed that day. On the thumbnails (the 1st, the 15th and the 31st), the prism spot is sharp and bright, but next to the position where the system looks for it: the target seems badly configured or badly positioned, not hidden. Curve to ignore; correct the position of the target in the configuration or check the prism.", "review": "2026-11-17"}
{"id": "CLARIDEN-14", "start": "2026-10-06T22:00Z", "end": "2026-10-11T06:00Z", "family": "Displacement", "description": "Slow drift of several targets over four days, made of small steps, then stabilization: D-303-B rises vertically, D-303-C and D-304-C rise vertically, D-301-C rises horizontally, D-306-B goes down horizontally. The camera moves: its tilt drifts slowly over the same days, with a small step on the 8th, and these targets follow it closely in the directions of their curves; the compensation does not absorb this tilt equally on every target. Ordinary recognition error, nothing on the images. The camera housing temperature stays almost constant over these days: no link with it. Slow return from the 11th to the 19th, labeled separately. Deduced from the curves and the camera pose: mostly a remainder of the camera tilt, not established as a movement of the structure; the camera is to be monitored, and these targets checked against the other measurements of the site."}