T
maximeandClaude Opus 5.5 ddb17c2189 auto: labels requalified under the 5-noise rules (only what stands out from the noise): 32 analyses refined, the 6 paused periods verified, the long labels requalified with the fixes the period analysts found; 1153 -> 961 labels
- 32 analyses: each label kept, rewritten or removed by its analyst (section Requalification of the report; mm magnitudes where the targets have them)
- SNCF01 x3, WILDSTRUBEL 2026-09-01 -> 2026-10-06 x3: verified from their existing labels under the new rules
- long labels (no analysis): auto/analyses/long-labels/<STATION>/; NORDEND-169 and -195 run to 07/11, so NORDEND-283 and -284 (their continuation) are removed
- reading-rules.md, stations.md: the citations of removed or rewritten labels point to their successor, or to [expert]

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-17 23:58:00 +01:00

460 B

CLARIDEN long labels: requalification

2 labels: 1 kept, 1 corrected, 0 removed.

  • CLARIDEN-14 corrected: the drift does stand out (up to about 20 noises: D-301-C horizontal about 1 mm, D-303-B vertical about 0.4 mm), but its text said "no camera movement". In fact the targets follow the slow tilt of the camera, so the conclusion is now "the camera is to be monitored" rather than "the targets may be moving". The bounds and the family are unchanged.