- 32 analyses: each label kept, rewritten or removed by its analyst (section Requalification of the report; mm magnitudes where the targets have them) - SNCF01 x3, WILDSTRUBEL 2026-09-01 -> 2026-10-06 x3: verified from their existing labels under the new rules - long labels (no analysis): auto/analyses/long-labels/<STATION>/; NORDEND-169 and -195 run to 07/11, so NORDEND-283 and -284 (their continuation) are removed - reading-rules.md, stations.md: the citations of removed or rewritten labels point to their successor, or to [expert] Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
1.1 KiB
1.1 KiB
Requalification of the long labels: MICHIGAN
- MICHIGAN-3 (Target issue, REFPOU22, 09/10 08:00 → 01/11 00:00): kept as is. A reference rejected at every measurement from 09/10 12:00 to the end of the month (100 %: 20/20 in the first period, 65/65 in the second, every one in the third, according to the period reports), so a target rejected almost always; its loss also makes all the targets jump at 09/10 12:00 (period report 1).
- MICHIGAN-7 (Displacement, slow camera tilt, 16/10 12:00 → 01/11 00:00): removed.
ranges.py --k 5 --min-measurements 6on the label's range (work/ranges_m7.txt): no target has a corr_x or corr_y range of six or more measurements (one day) beyond 5 of its own noises. The 60 short corr_x ranges and 16 short corr_y ranges are the brief common excursions already labelled apart (MICHIGAN-8, -9, -11, -13, -14, -15). The slow drift itself stays within the noise of the corrected curves. The correction asked for (the camera leans back from 16/10 12:00 to 17/10 12:00) therefore no longer applies. Confidence medium: the--rollingcheck and the magnitudes in mm were not run (usage limit reached).