- 32 analyses: each label kept, rewritten or removed by its analyst (section Requalification of the report; mm magnitudes where the targets have them) - SNCF01 x3, WILDSTRUBEL 2026-09-01 -> 2026-10-06 x3: verified from their existing labels under the new rules - long labels (no analysis): auto/analyses/long-labels/<STATION>/; NORDEND-169 and -195 run to 07/11, so NORDEND-283 and -284 (their continuation) are removed - reading-rules.md, stations.md: the citations of removed or rewritten labels point to their successor, or to [expert] Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
3 lines
3.4 KiB
JSON
3 lines
3.4 KiB
JSON
{"id": "MICHIGAN-3", "start": "2026-10-09T08:00Z", "end": "2026-11-01T00:00Z", "family": "Target issue", "description": "The reference REFPOU22 is lost on 9 October between the 08:00 measurement and the 12:00 one, and does not come back until the end of the month: its error_value rises almost to the maximum, it is rejected at every measurement and its raw positions wander far from its place. On the thumbnails, its spot, sharp at 04:00 and 08:00 on 9 October, has disappeared at 12:00 and does not come back (also seen on 12 October, 20 October and 31 October), while the neighboring spots and REF42, REFG43N are intact; no obstacle is visible. At 12:00 on 9 October, corr_x and corr_y of all the targets jump together and stay shifted, without a step in the raw positions: the compensation now only runs on REF42 and REFG43N, its reprojection error drops to zero and the basis changes. With these two references only, close to each other and far from the targets, the compensation is fragile: the curves of all the targets are more agitated than before, and the slightest deviation of these two references relative to the targets passes, amplified, into all the targets. At the same measurement, NEBRASKA, in the same building as MICHIGAN according to the expert, also loses one of its references (REFCOLH22), whose spot disappears in the same way with no visible obstacle: a cause common to both, in the building, is to be looked for; it is not established. The reference of the same name seen by BREITHORN stays sharp on its images. Cause of the loss not established (prism masked, turned or removed). For the customer: the jump is not a movement, and the corrected curves since 9 October are not very reliable; check the prism of REFPOU22 on site and restore it.", "review": "2026-11-17"}
|
|
{"id": "MICHIGAN-7", "start": "2026-10-16T12:00Z", "end": "2026-11-01T00:00Z", "family": "Displacement", "description": "From 16 October to the end of the month, the camera nods forward again, rotates and its scale drops, faster from 17 October with the drop in the camera housing temperature; all the targets slide together in the image, without moving relative to each other. The corr_x of all the targets rises by a step on 17 and 18 October and stays high until the 28th; after the cold mornings of 29 and 30 October, it ends up lower and stays there until the end of the month; the corr_y of all the targets goes down slowly over the whole range. The compensation on REF42 and REFG43N alone, since the loss of REFPOU22, passes this movement into all the targets. Deduced from the curves and the camera pose; nothing on the images. According to the expert, BREITHORN, MICHIGAN and NEBRASKA are in the same building: the cameras of the three stations tilt together, in the same direction and on the same dates (advance until 12 October, stop and slight backward movement from 13 to 16, resumption from the 17th to the end of the month), which points to a cause common to the building rather than a fault of this camera alone; at equal housing temperature, the cameras are more tilted at the end of the month than in the middle: temperature does not explain it alone, link not established. The station is in a factory, indoors, according to the expert: it is not a day/night cycle. For the customer: the targets do not move relative to each other, this is not a movement of the structure; the camera tilt is to be monitored, and restoring a third reference will make the curves reliable again.", "review": "2026-11-17"}
|