- 32 analyses: each label kept, rewritten or removed by its analyst (section Requalification of the report; mm magnitudes where the targets have them) - SNCF01 x3, WILDSTRUBEL 2026-09-01 -> 2026-10-06 x3: verified from their existing labels under the new rules - long labels (no analysis): auto/analyses/long-labels/<STATION>/; NORDEND-169 and -195 run to 07/11, so NORDEND-283 and -284 (their continuation) are removed - reading-rules.md, stations.md: the citations of removed or rewritten labels point to their successor, or to [expert] Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
30 lines
22 KiB
JSON
30 lines
22 KiB
JSON
{"start": "2026-10-14T07:15Z", "end": "2026-10-15T01:15Z", "family": "Thermal displacement", "description": "Daytime thermal cycle (14/10): from the morning, the pan and the tilt of the camera drop and its scale rises, then they slowly come back in the afternoon, the evening and the night, until the camera comes to rest around one in the morning; the two-in-the-morning gap and the camera jump of the early morning, labelled separately, come after this rest. The corrected curves follow the same cycle, poorly compensated: corr_x of P7, P5, P6 and corr_y of P5, P6, P7, P4 move away from their night level during the day then come back, partly all at once at nightfall, when the recognition error also comes back (the lighting plays a part). Deduced cause: the camera and its mount move with the heat of the day (camera pose); the structure, a masonry wall, is not supposed to move like that. No temperature is available to confirm it. Normal, nothing to do.", "review": "2026-11-17"}
|
|
{"start": "2026-10-14T09:30Z", "end": "2026-10-14T16:30Z", "family": "Visibility", "description": "By day (14/10), in the sun (hard shadows on the wall on the image of 13:00): the corrected curves of the low targets fluctuate much more than at night, from one measurement to the next, with one-measurement jumps that come back at once, mostly CV.4, CV.2, F4.3, CV.6, F4.2, BG.2, F4.5 and F4.6, and CV.2 and CV.4 are rejected at times; the night before and the evening after are calm. Deduced cause: heat shimmer from the air heated above the tracks (a fast noise over the scene, by sunny day only), not visible as such on the images; some rejections of CV.2 and CV.4, low targets, may also come from passages, not seen. Do not trust the small movements of these curves by day; this is not a movement of the structure."}
|
|
{"start": "2026-10-14T10:30Z", "end": "2026-10-14T11:00Z", "family": "Obstruction", "description": "One single measurement: CV.2, CV.4 and CV.8 are rejected, their curves are missing, the recognition error of the reference BG.3.1 jumps strongly while staying under its threshold, and CV.6, F4.2 and F4.6 make a corr jump that comes back at the next measurement. Cause: a passage in front of the bottom of the scene and of BG.3.1, deduced from the signature (several low targets and a reference hit together for one measurement; no image at that minute, the station takes one per hour). The structure is not moving: point to ignore, nothing to do."}
|
|
{"start": "2026-10-15T01:45Z", "end": "2026-10-15T02:45Z", "family": "No data", "description": "Two measurements are missing half an hour apart, with a single measurement between them, for all sensors, around two in the morning: all curves have a gap; the image of two o'clock exists nonetheless. The power metrics of the station are empty over the whole month. This one-measurement night gap, around 02:00 UTC, falls at the same measurement on FLORIDA and SNCF01 on 09, 14 and 15/10, and only on them; other stations have the same night gap around the same hour on other weeks (JUNGFRAU and NORDEND in early September): a common cause outside the station, at night, is probable; it is not established. Nothing to do on the station if it does not get worse.", "review": "2026-11-17"}
|
|
{"start": "2026-10-15T05:15Z", "end": "2026-10-15T05:45Z", "family": "Displacement", "description": "One-measurement jump that lasts: on the 15th in the early morning, from one measurement to the next, the raw positions of all sensors, references included, jump together in the image (the tilt of the camera makes a step, which the pose then keeps), and the recognition error of P4, P7 and of the references R1, R2 goes up a notch. The compensation does not absorb it entirely: corr_y of P4, P5, P7, CV.1 and of the reference R1 drops at once, that of R2 rises, and these levels mostly remain on the following days. No image at that moment; cause not established (a jolt of the camera or of its mount, deduced from the pose). Relative to the overall movement, the targets move together with the camera, without moving relative to one another; the references R1 and R2 do not quite follow it, hence the remainder on the corrected curves. This is not an established movement of the structure: to be watched, on the camera and mount side.", "review": "2026-11-17"}
|
|
{"start": "2026-10-15T08:15Z", "end": "2026-10-15T15:45Z", "family": "Visibility", "description": "By day (15/10): the corrected curves of all targets fluctuate much more than at night, from one measurement to the next, especially CV.2, CV.4, F4.2, BG.3, CV.6, CV.9, with one-measurement jumps that come back at once, and CV.2, CV.4 (sometimes F4.2) are rejected at times, their curves having gaps; their recognition error varies strongly by day. At night everything becomes calm again. Deduced cause: heat shimmer from the air heated above the tracks (a fast noise over the whole scene, by day only), not visible on the images; the rejections of CV.2 and CV.4, low targets, may also come from passages, not seen. Do not trust the small movements of these curves by day; this is not a movement of the structure.", "review": "2026-11-17"}
|
|
{"start": "2026-10-15T08:45Z", "end": "2026-10-15T22:45Z", "family": "Thermal displacement", "description": "Daytime thermal cycle (15/10): from the morning, the pan and the tilt of the camera drop and its scale rises, then they slowly come back in the afternoon and the evening; the night outage falls before the return. The corrected curves follow the same cycle, poorly compensated: corr_x of P7, P5, P6 and corr_y of P5, P6, P7, P4 move away from their night level during the day then come back, partly all at once at nightfall, when the recognition error also comes back (the lighting plays a part). Deduced cause: the camera and its mount move with the heat of the day (camera pose); the structure, a masonry wall, is not supposed to move like that. No temperature is available to confirm it. Normal, nothing to do.", "review": "2026-11-17"}
|
|
{"start": "2026-10-15T22:45Z", "end": "2026-10-16T04:00Z", "family": "No data", "description": "No measurement for any sensor for several hours, on the night of 15 to 16, all curves are missing; no image either. The power metrics of the station are empty over the whole month. The gap starts at the same hour, around 23:00, on the nine stations that were measuring then (LENZSPITZE has its first measurements only in the middle of that night, WILDSTRUBEL is already stopped), and their metrics stop at the same time on most of them; measurements and metrics resume at different hours depending on the station, most in late morning. JUNGFRAU, whose metrics continue, accumulates unsent entries all night, sent in late morning, and its night measurements are nonetheless missing from the data: a common cause outside the stations (transmission or reception of the data), not an outage of the stations; it is not established. The curves are missing over the range; nothing to do on the station if it does not repeat.", "review": "2026-11-17"}
|
|
{"start": "2026-10-16T07:00Z", "end": "2026-10-17T07:30Z", "family": "Thermal displacement", "description": "Daytime thermal cycle (16/10): from the morning, the pan and the tilt of the camera drop and its scale rises, then they slowly come back in the afternoon, the evening and all night, until the start of the next morning. The corrected curves follow the same cycle, poorly compensated: corr_x of P7, P5, P6 and corr_y of P5, P6, P7, P4 move away from their night level during the day then come back, partly all at once at nightfall, when the recognition error also comes back (the lighting plays a part). Deduced cause: the camera and its mount move with the heat of the day (camera pose); the structure, a masonry wall, is not supposed to move like that. No temperature is available to confirm it. Normal, nothing to do.", "review": "2026-11-17"}
|
|
{"start": "2026-10-16T08:15Z", "end": "2026-10-16T13:30Z", "family": "Visibility", "description": "By day (16/10): the corrected curves of all targets fluctuate much more than at night, from one measurement to the next, especially CV.2, CV.4, F4.2, BG.3, CV.6, CV.9, with one-measurement jumps that come back at once, and CV.2, CV.4 (sometimes F4.2) are rejected at times, their curves having gaps; their recognition error varies strongly by day. At night everything becomes calm again. Deduced cause: heat shimmer from the air heated above the tracks (a fast noise over the whole scene, by day only), not visible on the images; the rejections of CV.2 and CV.4, low targets, may also come from passages, not seen. Do not trust the small movements of these curves by day; this is not a movement of the structure.", "review": "2026-11-17"}
|
|
{"start": "2026-10-16T11:30Z", "end": "2026-10-16T12:00Z", "family": "Obstruction", "description": "CV.4 makes a very large jump in corr_x and corr_y for the time of one measurement, its raw position jumping by several pixels, while CV.2 is rejected; everything comes back at the next measurement. Cause: probably a passage hiding these low targets, the system locking onto another spot; deduced (no image at that moment). The structure is not moving: point to ignore, nothing to do.", "review": "2026-11-17"}
|
|
{"start": "2026-10-16T13:30Z", "end": "2026-10-16T14:00Z", "family": "No data", "description": "One measurement is missing for all sensors, all curves have a gap; no image at that moment. The power metrics of the station are empty over the whole month. The same gap occurs at the same time on the other stations that measure at that time (FLORIDA, JUNGFRAU, NORDEND): a common cause outside the station (transmission or reception of the data), not a station failure; it is not established. The curves are missing over the range; nothing to do on the station.", "review": "2026-11-17"}
|
|
{"start": "2026-10-16T14:15Z", "end": "2026-10-16T14:45Z", "family": "No data", "description": "One measurement is missing for all sensors, all curves have a gap; no image at that moment. The power metrics of the station are empty over the whole month. The same gap occurs at the same time on the other stations that measure at that time (CLARIDEN, FLORIDA, LENZSPITZE, NORDEND): a common cause outside the station (transmission or reception of the data), not a station failure; it is not established. The curves are missing over the range; nothing to do on the station.", "review": "2026-11-17"}
|
|
{"start": "2026-10-16T15:45Z", "end": "2026-10-16T16:15Z", "family": "Obstruction", "description": "One single measurement: the CV, F4 and P targets are rejected and their curves are missing; the references BG.3.1 and R1 are rejected too, the compensation retains none of them, and the targets that stayed under their threshold, BG.2, BG.3 and F4.5, jump strongly in corr_x and corr_y for the time of the measurement, as does the reference R2. Everything comes back at the next measurement. Cause: a train passing in front of the targets and the references, seen blurred across the whole lower scene on the 16:00 image. The structure is not moving: point to ignore, nothing to do."}
|
|
{"start": "2026-10-17T07:30Z", "end": "2026-10-18T07:45Z", "family": "Thermal displacement", "description": "Daytime thermal cycle (17/10): from the morning, the pan and the tilt of the camera drop and its scale rises, then they slowly come back in the afternoon, the evening and all night, until the start of the next morning; the rejections of F4.2 that night, labelled separately, do not affect the references and do not distort the pose. The corrected curves follow the same cycle, poorly compensated: corr_x of P7, P5, P6 and corr_y of P5, P6, P7, P4 move away from their night level during the day then come back, partly all at once at nightfall, when the recognition error also comes back (the lighting plays a part). Deduced cause: the camera and its mount move with the heat of the day (camera pose); the structure, a masonry wall, is not supposed to move like that. No temperature is available to confirm it. Normal, nothing to do.", "review": "2026-11-17"}
|
|
{"start": "2026-10-17T08:00Z", "end": "2026-10-17T16:45Z", "family": "Visibility", "description": "By day (17/10): the corrected curves of all targets fluctuate much more than at night, from one measurement to the next, especially CV.2, CV.4, F4.2, BG.3, CV.6, CV.9, with one-measurement jumps that come back at once, and CV.2, CV.4 (sometimes F4.2) are rejected at times, their curves having gaps; their recognition error varies strongly by day. At night everything becomes calm again. Deduced cause: heat shimmer from the air heated above the tracks (a fast noise over the whole scene, by day only), not visible on the images; the rejections of CV.2 and CV.4, low targets, may also come from passages, not seen. Do not trust the small movements of these curves by day; this is not a movement of the structure.", "review": "2026-11-17"}
|
|
{"start": "2026-10-17T09:45Z", "end": "2026-10-17T10:15Z", "family": "Obstruction", "description": "CV.2 makes a very large jump in corr_x and corr_y for the time of one measurement, its raw position jumping by several pixels: another spot was taken for the target; CV.4 is rejected; everything comes back at the next measurement. Cause: a blurry, bright object passes in front of the bottom of the scene and hides CV.2 and CV.1, seen on the 10:00 image (thumbnails). The structure is not moving: point to ignore, nothing to do.", "review": "2026-11-17"}
|
|
{"start": "2026-10-18T07:45Z", "end": "2026-10-18T15:45Z", "family": "Visibility", "description": "By day (18/10): the corrected curves of all targets fluctuate much more than at night, from one measurement to the next, especially CV.2, CV.4, F4.2, BG.3, CV.6, CV.9, with one-measurement jumps that come back at once, and CV.2, CV.4 (sometimes F4.2) are rejected at times, their curves having gaps; their recognition error varies strongly by day. At night everything becomes calm again. Deduced cause: heat shimmer from the air heated above the tracks (a fast noise over the whole scene, by day only), not visible on the images; the rejections of CV.2 and CV.4, low targets, may also come from passages, not seen. Do not trust the small movements of these curves by day; this is not a movement of the structure."}
|
|
{"start": "2026-10-18T07:45Z", "end": "2026-10-19T00:00Z", "family": "Thermal displacement", "description": "Daytime thermal cycle (18/10): from the morning, the pan and the tilt of the camera drop and its scale rises, then they slowly come back in the afternoon, the evening and the evening. The corrected curves follow the same cycle, poorly compensated: corr_x of P7, P5, P6 and corr_y of P5, P6, P7, P4 move away from their night level during the day then come back, partly all at once at nightfall, when the recognition error also comes back (the lighting plays a part). Deduced cause: the camera and its mount move with the heat of the day (camera pose); the structure, a masonry wall, is not supposed to move like that. No temperature is available to confirm it. Normal, nothing to do.", "review": "2026-11-17"}
|
|
{"start": "2026-10-18T20:00Z", "end": "2026-10-18T20:30Z", "family": "Obstruction", "description": "One single measurement: most targets (the CV, the F4 and some of the P) are rejected and their curves are missing; the references are affected too (BG.3.1 and R1 rejected), the compensation retains none of them, and the targets that stayed under the threshold (BG.2, BG.3, F4.5 and some P) jump in corr_x and corr_y for the time of the measurement. Everything comes back at the next measurement. Cause: a passage in front of the targets and the references, no image at that moment; deduced from the signature, the same as that of the trains seen on the images of the other passages. The structure is not moving: point to ignore, nothing to do.", "review": "2026-11-17"}
|
|
{"start": "2026-10-19T07:15Z", "end": "2026-10-20T12:45Z", "family": "Displacement", "description": "On 19/10, an overcast day (images of 08:00 and 13:00, no sun on the wall), the camera moves in the morning and does not come back: its pan and tilt drop and its scale rises, then stay at their new level in the afternoon and at night, until the outage of 20/10. At the same time the targets move apart from each other in the image (residual relative to the overall movement): corr_x of P5, P6 and P7 rises and that of P2 drops clearly, and corr_y of P5 rises, through the afternoon and the night, while the residual of the compensation rises from late morning and the recognition error of the reference R1 from the late afternoon. No return before the outage; after it, on 21/10, P2 and P5 are still near their new levels. Not the daily thermal cycle: no sun, the pose does not come back, no temperature is available. Cause not established (a camera or reference movement that the compensation does not follow, or a movement of the scene). Movement of the structure not established: to monitor; part of the month-long drift labelled separately."}
|
|
{"start": "2026-10-19T09:00Z", "end": "2026-10-19T10:15Z", "family": "No data", "description": "Several consecutive measurements are missing for all sensors, for an hour, all curves are missing; no image either. The power metrics of the station are empty over the whole month. The same gap occurs at the same time on the other stations that measure at that time (CLARIDEN, FLORIDA, JUNGFRAU, LENZSPITZE, NIEDERHORN, NORDEND): a common cause outside the station (transmission or reception of the data), not a station failure; it is not established. The curves are missing over the range; nothing to do on the station.", "review": "2026-11-17"}
|
|
{"start": "2026-10-19T20:45Z", "end": "2026-10-19T21:15Z", "family": "No data", "description": "One measurement is missing for all sensors, all curves have a gap; no image at that moment. The power metrics of the station are empty over the whole month. The same gap occurs at the same time on the other stations that measure at that time (CLARIDEN, FLORIDA, JUNGFRAU, LENZSPITZE, NIEDERHORN, NORDEND): a common cause outside the station (transmission or reception of the data), not a station failure; it is not established. The curves are missing over the range; nothing to do on the station. The hourly metrics of BREITHORN, MICHIGAN and NEBRASKA are also missing at 21:00.", "review": "2026-11-17"}
|
|
{"start": "2026-10-20T04:45Z", "end": "2026-10-20T08:00Z", "family": "Visibility", "description": "At night on 20/10, before dawn, the reference R1 is less well seen: its recognition error rises a notch at once and stays high until mid-morning, and its measured position slides alone in the image (the targets do not move relative to the overall movement). The compensation follows it: corr_y of P7, P6 and P5 rises together clearly for a few hours, while the reference R2 moves the other way, then everything comes back as the position of R1 returns, around eight. The train passage of that morning, labelled separately, falls inside. Nothing in front of R1 on the night images of 05:00, 06:00 and 07:00 (its spot whole, same place); the night is one of poor visibility for several faint targets (CV.6 rejected all night, F4.2 at times). Cause deduced: the reference less well seen in the night of poor visibility, not an obstacle. Do not trust the small shift of these curves over the range; this is not a movement of the structure."}
|
|
{"start": "2026-10-20T05:30Z", "end": "2026-10-20T06:00Z", "family": "Obstruction", "description": "One single measurement: the CV, F4 and P targets are rejected and their curves are missing; the references BG.3.1 and R1 are rejected too, the compensation retains none of them, and the targets that stayed under their threshold, BG.2, BG.3, F4.5 and F4.6, jump strongly in corr_x and corr_y for the time of the measurement, as does the reference R2. Everything comes back at the next measurement. Cause: a passage in front of the targets and the references, deduced from the signature, the same as that of the train seen on the 16:00 image of 16/10 (no image at that minute). It falls inside the episode of the reference R1 of that morning, labelled separately. The structure is not moving: point to ignore, nothing to do."}
|
|
{"start": "2026-10-20T12:45Z", "end": "2026-10-21T10:00Z", "family": "No data", "description": "Measurements are missing intermittently, then an outage of about twenty hours. No measurement for any sensor, all curves are missing; no image either. The power metrics of the station are empty over the whole month: the cause is not established (acquisition, power or transmission). If long outages repeat, check the power and the transmission of the station.", "review": "2026-11-17"}
|
|
{"start": "2026-10-21T10:00Z", "end": "2026-10-21T15:45Z", "family": "Visibility", "description": "By day (21/10): the corrected curves of all targets fluctuate much more than at night, from one measurement to the next, especially CV.2, CV.4, F4.2, BG.3, CV.6, CV.9, with one-measurement jumps that come back at once, and CV.2, CV.4 (sometimes F4.2) are rejected at times, their curves having gaps; their recognition error varies strongly by day. At night everything becomes calm again. Deduced cause: heat shimmer from the air heated above the tracks (a fast noise over the whole scene, by day only), not visible on the images; the rejections of CV.2 and CV.4, low targets, may also come from passages, not seen. Do not trust the small movements of these curves by day; this is not a movement of the structure.", "review": "2026-11-17"}
|
|
{"start": "2026-10-21T10:00Z", "end": "2026-10-21T19:30Z", "family": "Thermal displacement", "description": "Daytime thermal cycle (21/10, sunny, between two measurement outages): in late morning the pan of the camera drops and its scale rises, then the camera comes back in the afternoon and its tilt rises in the evening. The compensation absorbs most of it, but not all: in the late afternoon and the evening, with the tilt rising, corr_x of P5 and P7 dips clearly below its level of the morning, then they come back at the isolated measurement after the gap. Deduced cause: the camera and its mount move with the heat of the day (camera pose); the structure, a masonry wall, is not supposed to move like that. No temperature is available to confirm it. Normal, nothing to do."}
|
|
{"start": "2026-10-21T19:30Z", "end": "2026-10-22T10:30Z", "family": "No data", "description": "Night outage, one single isolated measurement at the start. No measurement for any sensor, all curves are missing; no image either. The power metrics of the station are empty over the whole month: the cause is not established (acquisition, power or transmission). If long outages repeat, check the power and the transmission of the station.", "review": "2026-11-17"}
|