- 32 analyses: each label kept, rewritten or removed by its analyst (section Requalification of the report; mm magnitudes where the targets have them) - SNCF01 x3, WILDSTRUBEL 2026-09-01 -> 2026-10-06 x3: verified from their existing labels under the new rules - long labels (no analysis): auto/analyses/long-labels/<STATION>/; NORDEND-169 and -195 run to 07/11, so NORDEND-283 and -284 (their continuation) are removed - reading-rules.md, stations.md: the citations of removed or rewritten labels point to their successor, or to [expert] Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
5.5 KiB
CLARIDEN: labels of 11–20 October, requalified
You asked me to requalify the labels of 11 October 00:00 → 20 October 04:00 (UTC) under the new rule: only what stands out from the noise is labelled.
In short
11 of the 12 labels stay. The slight straightening of the camera on the 11th–13th leaves too little on the curves to label, so it is removed. The curves cannot be trusted during the camera tilt of the 17th to the 20th, in a few short bumps, and in the gaps. No real movement of the structure is established. Row C comes back slowly on the 11th–16th, and D-306-B and D-302-B keep a jump after the 20th: both are still to be checked.
Requalification
Kept 10, rewritten 1, removed 1.
- CLARIDEN-51 (11th 14:00 → 13th 02:00, camera straightens slowly): removed. No target goes beyond 5 noises, measured against the level before, the level after, or the label's own range. The largest remainder, D-306-B in vertical, is about 3 noises (about 0.03 mm).
- CLARIDEN-49 (11th 06:00 → 16th 12:00, slow return of row C): rewritten. Its description said the straightening of the 11th–13th was "labeled separately", which is no longer true. The label stays: against the level reached after the return, D-301-C stays beyond 5 noises for two hours on the 11th (up to about 6 noises).
What happened
The camera tilts slowly from the 17th to the 20th, and the correction does not follow evenly. All targets and references move together in the image as the camera tilts. After the correction, a few targets keep part of the movement in vertical: D-302-B rises, while D-303-B, D-304-B, P-301-B, D-303-C and D-304-C go down. The error reaches about 0.1 to 0.2 mm at its deepest, on the 19th (up to about 7 noises). They come back at once when the camera jumps back on the 20th. On the 11th–13th the camera straightened a little the other way, but that time the correction absorbed it. Cause: likely an incomplete correction of a camera movement. The temperature does not explain it.
Top: the camera tilt. Bottom: the vertical curves of five targets. In the second grey zone (17th–20th) they follow the tilt and jump back with it on the 20th. In the first one (11th–13th) they stay within the noise.
The camera jumps on the 20th, shortly after midnight. The whole scene shifts in two measurements, and most targets return to where they were before the 17th. D-306-B jumps up and stays there: only about 0.06 mm, because it is 2 m from the camera. D-302-B/PR_BG jumps sideways by about 0.14 mm and stays there. Cause of the camera jump: unknown.
Row C comes back slowly, 11th–16th. After their drift of the 6th–11th, D-301-C comes back sideways by about 0.2 mm, and D-304-C and D-303-C come back down by about 0.13–0.15 mm. The camera is still while they move. This is just above the threshold. Cause: not established. In a tunnel under construction, a movement of these targets is possible.
Short disturbances. On the 18th from 08:50 to 09:30, a short bump on many targets (up to about 0.6 mm on D-301-C, 0.3 mm on D-302-B) comes with a rise of the recognition error on most sensors. Reduced visibility is likely, but it is not seen on the image. On the 11th at 09:00 and the 18th at 06:40, many targets jump together for one measurement (about 0.3–0.5 mm on row A). The references move slightly against each other, which skews the correction. Cause unknown; ignore these points.
Gaps. No measurement at all on the night of the 15th–16th, for one measurement on the 16th, and twice on the 19th: these gaps fall at the same time at other stations. On the 18th from 13:50 to 23:30 there was a power cut. The station is in a tunnel and has no weather station nearby.
What to do
Check the camera mount and its fixing: its tilt wanders a little over days and jumped on the 20th. Compare row C (11th–16th), D-306-B and D-302-B (after the 20th) with the other measurements of the site.
Not established
- The cause of the slow tilt and of the jump of the 20th. Tunnel work at that time should be checked with the site.
- Whether the slow return of row C and the new levels of D-306-B and D-302-B are real movements. The other measurements of the site would settle it.
Labels
| Start (UTC) | End (UTC) | Family | Targets | In a few words |
|---|---|---|---|---|
| 2026-10-11 06:00 | 2026-10-16 12:00 | Displacement | D-301-C, D-303-C, D-304-C | slow return of row C after its drift of the 6th–11th |
| 2026-10-11 08:50 | 2026-10-11 09:10 | Displacement | row A, D-301-C, D-302-B/PR_BG, P-299-B… | one measurement, correction skewed |
| 2026-10-15 22:50 | 2026-10-16 10:30 | No data | all | night gap, common to the stations |
| 2026-10-16 14:20 | 2026-10-16 14:40 | No data | all | one missing measurement |
| 2026-10-17 16:00 | 2026-10-20 00:30 | Displacement | D-302-B/PR_BG, D-303-B, D-304-B, P-301-B, D-306-B, D-303-C, D-304-C | camera tilts slowly, part left on a few targets |
| 2026-10-18 06:30 | 2026-10-18 06:50 | Displacement | row A, D-302-B/PR_BG | one measurement, correction skewed |
| 2026-10-18 08:50 | 2026-10-18 09:30 | Visibility | row A, D-302-B/PR_BG, D-301-C, P-301-B, D-303-B | short bump with recognition error up |
| 2026-10-18 13:50 | 2026-10-18 23:30 | No data | all | power cut |
| 2026-10-19 09:00 | 2026-10-19 10:10 | No data | all | common gaps |
| 2026-10-19 20:40 | 2026-10-19 21:30 | No data | all | common gaps |
| 2026-10-20 00:10 | 2026-10-20 00:40 | Displacement | D-306-B, D-302-B/PR_BG, D-303-C, D-304-C, D-304-B, D-303-B, P-301-B | camera jump; most come back, D-306-B and D-302-B keep a jump |