{"id": "NEBRASKA-1", "start": "2026-10-03T00:00Z", "end": "2026-10-12T12:00Z", "family": "Displacement", "description": "From the start of the measurements, on 3 October, the corr_x of the targets at the top and the right of the image (COLJ20, POUJ20, POUJ19, COLJ19, then POUH19 and COLH19) rises slowly, without returning, until 12 October around noon; those at the bottom, near the references, hardly move. At the same time, the camera gradually nods forward: its tilt rises, its rotation turns and its scale drops, with a clearer step from the afternoon of 7 October to 8 October, which the compensation absorbs as long as the three references hold (no step on the curves that day). The rise of the targets is weak with three references and clearer after the loss of REFCOLH22 on 9 October (the jump of that day is another label). The raw positions of the targets move mostly with the camera: it is the compensation that renders this movement poorly. The camera housing temperature only drops a little over the phase. According to the expert, BREITHORN, MICHIGAN and NEBRASKA are in the same building: the cameras of the three stations tilt together, in the same direction and on the same dates (advance until 12 October, stop and slight backward movement from 13 to 16, resumption from the 17th to the end of the month), which points to a cause common to the building rather than a fault of this camera alone; at equal housing temperature, the cameras are more tilted at the end of the month than in the middle: temperature does not explain it alone, link not established. Deduced from the curves and the camera pose. For the customer: the camera tilts and the scene deforms with it: a movement of the structure is not established; the camera tilt is to be monitored, and restoring a third reference will make the curves reliable again.", "review": "2026-11-17"}
|
|
{"id": "NEBRASKA-2", "start": "2026-10-09T08:00Z", "end": "2026-11-01T00:00Z", "family": "Target issue", "description": "The reference REFCOLH22 is lost at the 9 October noon measurement and does not come back until the end of the month: its error_value jumps almost to the maximum and all its measurements are rejected. On the thumbnails, its spot, sharp and round until the morning of 9 October, has disappeared from its place at the next measurement, while the neighboring spot and the other references are intact; what made it disappear (prism fallen, removed, hidden) is not visible on the whole image. At the same measurement, MICHIGAN, in the same building as NEBRASKA according to the expert, also loses one of its references (REFPOU22), whose spot disappears in the same way with no visible obstacle: a cause common to both, in the building, is to be looked for; it is not established. At the loss, all the targets jump together in one step: corr_x upward, most on COLJ20, POUJ19, POUJ20 and POUH19, and corr_y upward on COLH19, COLH20, COLJ23 and COLJ24; the jump does not return, it is not a movement. The compensation then runs on the two only references REFH22 and REFP''21 (the corrections of these two references cancel): a more fragile basis, which no longer compensates the camera movement well and makes all the targets move at the slightest deviation of a reference. Very bad sign for the measurement: check the prism of REFCOLH22 on site and restore it.", "review": "2026-11-17"}
|
|
{"id": "NEBRASKA-3", "start": "2026-10-13T04:00Z", "end": "2026-10-17T04:00Z", "family": "Displacement", "description": "Slow bump of the corr_y of the top targets (COLJ20, POUJ20, POUJ19, COLJ19, and a little COLH19 and POUH19): it rises by a notch on 13 October in the morning, stays high, then goes back down on 17 October in the morning; the corr_x of COLJ20 and POUJ20 recedes a little at the same time. At the same moment the camera goes back: its tilt goes back down from its peak of 12 October and its pan goes to its lowest of the month, then goes up again on 17 October. The camera housing temperature rises a little at the start then stays stable: link not established. According to the expert, BREITHORN, MICHIGAN and NEBRASKA are in the same building: the cameras of BREITHORN and MICHIGAN stop and move back on the same days. Deduced from the curves and the pose: it is the camera that moves, poorly compensated with two references, and the scene deforms with it: POUH20 goes back down with it. For the customer: the camera straightens and the scene deforms with it: a movement of the structure is not established; the camera tilt is to be monitored, and restoring a third reference will make the curves reliable again.", "review": "2026-11-17"}
|
|
{"id": "NEBRASKA-4", "start": "2026-10-15T20:00Z", "end": "2026-10-16T12:00Z", "family": "No data", "description": "No measurement for any sensor for three measurements, in the night of 15 to 16 October: all the curves are missing, then resume at the same level as before the gap. The station metrics (voltage, temperatures) are also missing over the same range; the voltage is normal just before and just after, so it is not a lack of energy. The same gap affects the two other stations of the building (BREITHORN, MICHIGAN, in the same building according to the expert), but also all the other stations. The gap starts at the same time, around 23:00, on the nine stations that were measuring then (LENZSPITZE only has its first measurements in the middle of that night, WILDSTRUBEL is already stopped), and their metrics stop at the same time on most of them; measurements and metrics resume at different times depending on the station, most of them in late morning. JUNGFRAU, whose metrics continue, accumulates unsent entries all night, sent in late morning, and yet its measurements for the night are missing from the data: a common cause outside the stations (transmission or reception of the data), not a shutdown of the stations; it is not established. The cause is therefore not specific to the building. The curves are missing over the range; nothing to do on the station if it does not repeat.", "review": "2026-11-17"}
|
|
{"id": "NEBRASKA-5", "start": "2026-10-16T20:00Z", "end": "2026-10-17T20:00Z", "family": "Displacement", "description": "The corr_x of COLJ19 alone jumps upward at the midnight measurement on 17 October, stays high all day, then partly returns in the evening; its neighbors do not jump. Its raw position in the image shifts by as much relative to the other targets, without the camera moving at that moment or its error_value changing; nothing on the thumbnails. It is not an effect of the compensation; cause not established, deduced from the curves and the raw positions. To be checked: look at the target and monitor its curve.", "review": "2026-11-17"}
|
|
{"id": "NEBRASKA-6", "start": "2026-10-16T20:00Z", "end": "2026-11-01T00:00Z", "family": "Displacement", "description": "Long upward drift of the corr_x of all the targets, strongest on the targets at the top and the right of the image (COLJ20, POUJ20, POUJ19, COLJ19, then COLH19, POUH19, COLH20) and weak on those close to the references (COLH21, COLJ23, COLJ24); the corr_y of COLH19, POUH19, POUJ20, COLJ19 and COLH20 goes down, that of POUH20 and COLH21 rises; no return at the end of the month. The camera keeps nodding forward as in the first half of the month (tilt rising, pan and rotation turning, scale dropping), and the compensation on two references only renders it poorly, so that the targets drift with it. The camera housing temperature drops from 16 October and the drift follows its jolts: fast rise until 19 October, slower until 24 October, stop and slight backward movement when the temperature rises again from 25 to 28 October, new rise with the cold of 28 and 29 October, slight backward movement when it rises again on 31 October. But the camera was already nodding forward from 3 to 12 October when the temperature was hardly dropping, and it stays more tilted at the end of the month than in the middle at equal temperature: temperature does not explain it alone, link not established. According to the expert, BREITHORN, MICHIGAN and NEBRASKA are in the same building: the cameras of the three stations tilt together, in the same direction and on the same dates (advance until 12 October, stop and slight backward movement from 13 to 16, resumption from the 17th to the end of the month), which points to a cause common to the building rather than a fault of this camera alone. Checked target by target (ensemble.py --rigide, and a camera transformation fitted on the other targets): the scene does not move quite as a block, it deforms while the camera tilts. POUH20 moves away the most from the other targets, its neighbor POUH21 hardly at all; then COLH21, and the targets at the edges of the image (COLJ19, COLJ20, COLH19); hence the rise of the corr_y of POUH20 and COLH21. These deviations follow the camera tilt in both directions: POUH20 rises with it on 11 and 12 October, goes back down when it straightens from 13 to 16 October, rises fast with it from 17 to 19 October, then slowly until the end of the month; COLH21 only moves away from 18 October, when the camera exceeds its tilt of the 12th. It is the same movement as that of the camera, not a separate event; at equal tilt, POUH20 stays slightly higher after 17 October than before. Cause not established (the camera moving slightly as it tilts, targets at different distances, or a movement of the structure with the building). Deduced from the curves, the raw positions, the pose and the temperatures; images with nothing clear. For the customer: the camera tilts and the scene deforms with it: a movement of the structure is not established; to be monitored, the camera tilt and the curves of POUH20 and COLH21, which move away the most; restoring a third reference will make the curves reliable again.", "review": "2026-11-17"}
|
|
{"id": "NEBRASKA-7", "start": "2026-10-18T16:00Z", "end": "2026-10-19T16:00Z", "family": "Thermal displacement", "description": "Cool morning of 19 October, the coldest of the month so far for the camera housing: the corr_y of POUJ19, COLJ20 and POUH20 rises from the evening of the 18th until noon, then returns; the corr_x of almost all the targets makes a peak at the 08:00 measurement (COLH19, COLH20, COLH21, POUH19, COLJ20). The camera nods forward during the night, most at 08:00, where its pan moves and its scale drops too, then everything returns. No reference poorly seen. Deduced from the curves, the pose and the temperatures: a brief camera movement with the cold, poorly compensated by the two-reference basis, like the cold mornings at the end of the month. The targets do not move: nothing to do, do not trust these points.", "review": "2026-11-17"}
|
|
{"id": "NEBRASKA-8", "start": "2026-10-26T00:00Z", "end": "2026-10-26T20:00Z", "family": "Thermal displacement", "description": "Cool morning of 26 October: from 04:00 to 16:00, the corr_y of the top targets rises (POUJ19, COLJ20, COLJ19, POUJ20 above all), then returns in the evening; the corr_x hardly moves. The camera nods forward and rotates at the same moment, at the trough of the camera housing temperature, read in the metrics, then partly returns. Nothing in front of the targets on the 08:00 image. According to the expert, BREITHORN, MICHIGAN and NEBRASKA are in the same building: the cameras of BREITHORN and MICHIGAN move the same morning, at the same cooling. Deduced from the curves, the pose and the temperatures: a brief camera movement with the cold, poorly compensated by the two-reference basis. The targets do not move: nothing to do, do not trust these points.", "review": "2026-11-17"}
|
|
{"id": "NEBRASKA-9", "start": "2026-10-27T20:00Z", "end": "2026-10-28T16:00Z", "family": "Thermal displacement", "description": "Cool morning of 28 October: from midnight to noon, the corr_y of most targets goes down (COLH19, POUH19, POUJ20, COLJ20, COLH20 above all), then returns in the afternoon; the corr_x of almost all the targets makes a peak at the 08:00 measurement (COLJ19, COLJ20, POUJ19, POUH20, POUH21). The camera moves at the same time, at the coldest hour of the morning for its housing: its pan and rotation move away at 04:00, it nods forward and its scale drops at 08:00, then everything returns at noon; no reference poorly seen, nothing on the images. Deduced from the curves, the pose and the temperatures: a brief camera movement with the cold, poorly compensated by the two-reference basis. The targets do not move: nothing to do, do not trust these points.", "review": "2026-11-17"}
|
|
{"id": "NEBRASKA-10", "start": "2026-10-28T20:00Z", "end": "2026-10-29T12:00Z", "family": "Thermal displacement", "description": "Coldest night of the month for the camera housing, from 28 to 29 October: from midnight to morning, the camera nods forward, its pan, rotation and scale move away, most at 04:00, then everything returns at noon. The corr_x of almost all the targets rises over these measurements, peaking at 04:00; the corr_y of most jumps upward at 04:00 (COLJ20, POUJ19, COLH19, POUH19, COLH20 above all), framed by lower measurements at 00:00 and 08:00. At 04:00, the two remaining references move slightly relative to each other in the image, which the two-reference basis translates into a rotation of the whole scene; the error_value of REFH22, COLH19 and COLH20 also rises, far from the threshold, without rejection. Thumbnails of REFH22, REFP''21 and COLH20 with nothing clear, spots unchanged. Deduced from the curves, the pose and the temperatures: thermal effect on the camera; the cause of the rise in error_value is not established. Not a movement of the structure: nothing to do, do not trust the curves over these measurements.", "review": "2026-11-17"}
|
|
{"id": "NEBRASKA-11", "start": "2026-10-29T20:00Z", "end": "2026-10-30T16:00Z", "family": "Thermal displacement", "description": "Same thing on the following cold night, from 29 to 30 October: the camera nods forward, its rotation and scale move away, most at 04:00, then return in the afternoon. The corr_x of the targets is higher from midnight to noon; the corr_y of most jumps upward at 04:00 (COLJ20, POUJ19, POUH20, POUJ20 above all), then downward at 08:00. The error_value of REFH22 and COLH20 rises to its highest of the month at 04:00, that of COLH19 too, far from the threshold, without rejection. 04:00 thumbnails with nothing clear, spots unchanged. Deduced from the curves, the pose and the temperatures: thermal effect on the camera, poorly compensated by the two-reference basis; the cause of the rise in error_value is not established. Not a movement: do not trust the curves over these measurements.", "review": "2026-11-17"}
|