- 32 analyses: each label kept, rewritten or removed by its analyst (section Requalification of the report; mm magnitudes where the targets have them) - SNCF01 x3, WILDSTRUBEL 2026-09-01 -> 2026-10-06 x3: verified from their existing labels under the new rules - long labels (no analysis): auto/analyses/long-labels/<STATION>/; NORDEND-169 and -195 run to 07/11, so NORDEND-283 and -284 (their continuation) are removed - reading-rules.md, stations.md: the citations of removed or rewritten labels point to their successor, or to [expert] Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
27 lines
21 KiB
JSON
27 lines
21 KiB
JSON
{"start": "2026-10-22T10:30Z", "end": "2026-10-22T13:30Z", "family": "No data", "description": "Between two outages, on 22/10 in late morning, measurements are missing intermittently: only a few isolated measurements arrive. No measurement for any sensor between them, all curves are missing; no image either. The power metrics of the station are empty over the whole month: the cause is not established (acquisition, power or transmission). If long outages repeat, check the power and the transmission of the station.", "review": "2026-11-17"}
|
|
{"start": "2026-10-22T10:30Z", "end": "2026-10-22T15:30Z", "family": "Thermal displacement", "description": "Daytime thermal cycle (22/10), over a few measurements between outages, under an overcast sky (13:30 and 14:00 images): the pan of the camera is low and its scale high until early afternoon, at their extreme at 13:30, then they begin to come back at the isolated 15:30 measurement, the tilt staying low. The corrected curves keep it: the corr_x of P5 and P7 and the corr_y of P6 stay clearly above their level of the previous evening all day, flat, and P7 starts to come back at 15:30, when the corrections of the references also shift a little. Deduced cause: the camera and its mount move with the heat of the day (camera pose), the compensation absorbing only part of it; the structure, a masonry wall, is not supposed to move like that. No temperature is available to confirm it. Normal, nothing to do."}
|
|
{"start": "2026-10-22T15:00Z", "end": "2026-10-25T08:30Z", "family": "No data", "description": "One measurement is missing on 22/10 in the afternoon, then, after a single isolated measurement, an outage of nearly three days, until the morning of 25/10. No measurement for any sensor, all curves are missing; no image either. The power metrics of the station are empty over the whole month: the cause is not established (acquisition, power or transmission). If long outages repeat, check the power and the transmission of the station.", "review": "2026-11-17"}
|
|
{"start": "2026-10-25T08:30Z", "end": "2026-10-25T13:15Z", "family": "Visibility", "description": "By day (25/10, from the resumption of the measurements), in the sun (sunny morning with passing clouds on the images of 09:00 to 13:00, sharp shadows on the wall): the corrected curves of the targets fluctuate from one measurement to the next much more than at night, with one-measurement jumps that come back at once, above all CV.4, F4.2, F4.6, CV.9 and P1, and the noisy F4.3;; CV.2 and CV.4 are rejected at times, their curves having gaps. The recognition error of most sensors, the references included, varies strongly from one measurement to the next, which it does not do at night nor on the overcast days (22/10, 26/10), when the curves stay calm. The jumps stop after 13:00, when the sky clouds over (14:00 image). Deduced cause: heat shimmer, the air heated by the sun above the tracks and the ballast making the spots tremble (a fast noise over the whole scene, sunny hours only), not a nuisance seen on the images. Do not trust the small movements of these curves by day; this is not a movement of the structure."}
|
|
{"start": "2026-10-25T08:30Z", "end": "2026-10-25T22:15Z", "family": "Thermal displacement", "description": "Daytime thermal cycle (25/10): from the morning, the pan and the tilt of the camera drop and its scale rises, then they slowly come back in the afternoon and the evening; measurements resumed in the morning after the outage. The corrected curves follow the same cycle, poorly compensated: corr_x of P7, P5, P6 and corr_y of P5, P6, P7, P4 move away from their night level during the day then come back, partly all at once at nightfall, when the recognition error also comes back (the lighting plays a part). Deduced cause: the camera and its mount move with the heat of the day (camera pose); the structure, a masonry wall, is not supposed to move like that. No temperature is available to confirm it. Normal, nothing to do.", "review": "2026-11-17"}
|
|
{"start": "2026-10-25T23:30Z", "end": "2026-10-26T00:00Z", "family": "Obstruction", "description": "At night (25/10 23:45), for the time of one measurement, the CV targets (CV.1, CV.2, CV.4, CV.5, CV.8, CV.9) and F4.2 are rejected together, their curves are missing; the recognition error of the references BG.3.1 and R1 and of P5 and P7 rises without crossing the threshold, and P7, left under its threshold, jumps clearly in corr_x for that measurement: its point is wrong. The other targets do not move; everything comes back at the next measurement. Cause: probably a passage in front of this part of the scene, deduced from the signature (no image at that moment, the images being on the hour). The structure is not moving: point to ignore, nothing to do."}
|
|
{"start": "2026-10-26T08:15Z", "end": "2026-10-26T22:00Z", "family": "Thermal displacement", "description": "Daytime thermal cycle (26/10), under an overcast sky (12:00 image): from the morning, the pan and the tilt of the camera drop and its scale rises, less than on the sunny days, with no return before the 22:00 outage: the pan keeps dropping in the evening. The corrected curves keep part of it: the corr_x of P7 and P5 move clearly away from their night level during the day, P7 most at 10:00 when the tilt drops at once; in the evening they move further, during the episode labelled separately (Visibility). Deduced cause: the camera and its mount move with the heat of the day (camera pose); the structure, a masonry wall, is not supposed to move like that. No temperature is available to confirm it. Normal, nothing to do."}
|
|
{"start": "2026-10-26T14:30Z", "end": "2026-10-26T15:15Z", "family": "No data", "description": "Two measurements are missing for all sensors, all curves are missing; no image either. The power metrics of the station are empty over the whole month. The same gap occurs at the same time on the other stations that measure at that time (CLARIDEN, FLORIDA, JUNGFRAU, LENZSPITZE, NIEDERHORN, NORDEND), and their metrics are also missing at the same minutes: a common cause outside the station (transmission or reception of the data), not a station failure; it is not established. The curves are missing over the range; nothing to do on the station. The hourly metrics of BREITHORN, MICHIGAN and NEBRASKA are also missing at 15:00.", "review": "2026-11-17"}
|
|
{"start": "2026-10-26T15:15Z", "end": "2026-10-26T22:00Z", "family": "Visibility", "description": "In late afternoon and in the evening (26/10), from the resumption after the common gap of 15:00 until the 22:00 outage: the corr_x of P5 and P6 and the corr_y of P6 rise steadily and clearly, while the corr_y of P4, P3, P1 and the corr_x of P1 go down, instead of coming back as on the other evenings; the camera pose does not come back either (the pan drops, the scale rises again) and the registration residual is at its highest of the range. From 17:00 the recognition error of the reference R2, of BG.3.1 and of P1, P3, CV.1, F4.2 rises markedly; F4.2 then CV.8 are rejected for a while, and at 18:15 most CV and F4 targets rise together. The night images of 16:00 to 21:00 show nothing clear, the scene as on the night before. After the outage, on 28/10, the curves are back at their level. Cause not established: references less well seen (a visibility drop over the scene is likely) that skew the compensation. Do not trust the curves over the range."}
|
|
{"start": "2026-10-26T22:00Z", "end": "2026-10-28T07:15Z", "family": "No data", "description": "Outage of more than a day, with a single isolated measurement on 27/10 at 14:00. No measurement for any sensor, all curves are missing; no image either. The power metrics of the station are empty over the whole month: the cause is not established (acquisition, power or transmission). If long outages repeat, check the power and the transmission of the station.", "review": "2026-11-17"}
|
|
{"start": "2026-10-28T07:30Z", "end": "2026-10-28T22:45Z", "family": "Thermal displacement", "description": "Daytime thermal cycle (28/10): from the morning, the pan and the tilt of the camera drop and its scale rises, then they slowly come back in the afternoon and the evening; measurements resumed in the morning after the outage. The corrected curves follow the same cycle, poorly compensated: corr_x of P7, P5, P6 and corr_y of P5, P6, P7, P4 move away from their night level during the day then come back, partly all at once at nightfall, when the recognition error also comes back (the lighting plays a part). Deduced cause: the camera and its mount move with the heat of the day (camera pose); the structure, a masonry wall, is not supposed to move like that. No temperature is available to confirm it. Normal, nothing to do.", "review": "2026-11-17"}
|
|
{"start": "2026-10-28T08:00Z", "end": "2026-10-28T14:45Z", "family": "Visibility", "description": "By day (28/10), in the sun (full sun on the 12:00 image, sharp shadows on the wall): the corrected curves of the targets fluctuate from one measurement to the next much more than at night, with one-measurement jumps that come back at once, above all CV.4 and CV.2, then P2, P3 and CV.1;; CV.2 and CV.4 are rejected at times, their curves having gaps. The recognition error of most sensors, the references included, varies strongly from one measurement to the next, which it does not do at night nor on the overcast days (22/10, 26/10), when the curves stay calm. The jumps start in mid-morning, once the sun is on the scene, and stop in mid-afternoon. Deduced cause: heat shimmer, the air heated by the sun above the tracks and the ballast making the spots tremble (a fast noise over the whole scene, sunny hours only), not a nuisance seen on the images. Do not trust the small movements of these curves by day; this is not a movement of the structure."}
|
|
{"start": "2026-10-28T10:15Z", "end": "2026-10-28T10:45Z", "family": "Obstruction", "description": "CV.2 makes a very large jump in corr_x and corr_y for the time of one measurement, its raw position jumping by several pixels: another spot was taken for the target; CV.4 is rejected; everything comes back at the next measurement. Cause: probably a passage, like on 17/10 at 10:00; deduced (no image at that moment). The structure is not moving: point to ignore, nothing to do.", "review": "2026-11-17"}
|
|
{"start": "2026-10-28T21:00Z", "end": "2026-10-28T21:30Z", "family": "Obstruction", "description": "One single measurement: most targets (the CV, the F4 and some of the P) are rejected and their curves are missing; the references are affected too (BG.3.1 and R1 rejected), the compensation retains none of them, and the targets that stayed under the threshold (BG.2, BG.3, F4.5 and some P) jump in corr_x and corr_y for the time of the measurement. Everything comes back at the next measurement. Cause: a passage in front of the targets and the references, no image at that moment; deduced from the signature, the same as that of the trains seen on the images of the other passages. The structure is not moving: point to ignore, nothing to do.", "review": "2026-11-17"}
|
|
{"start": "2026-10-28T22:30Z", "end": "2026-10-28T23:00Z", "family": "Obstruction", "description": "One single measurement: most targets (the CV, the F4 and some of the P) are rejected and their curves are missing; the references are affected too (BG.3.1 and R1 rejected), the compensation retains none of them, and the targets that stayed under the threshold (BG.2, BG.3, F4.5 and some P) jump in corr_x and corr_y for the time of the measurement. Everything comes back at the next measurement. Cause: a passage in front of the targets and the references, no image at that moment; deduced from the signature, the same as that of the trains seen on the images of the other passages. The structure is not moving: point to ignore, nothing to do.", "review": "2026-11-17"}
|
|
{"start": "2026-10-29T07:45Z", "end": "2026-10-29T23:15Z", "family": "Thermal displacement", "description": "Daytime thermal cycle (29/10), sunny day (12:00 image): from the morning, the pan and the tilt of the camera drop and its scale rises, then they slowly come back in the afternoon and the evening, the pan reaching its night level late in the evening. The corrected curves follow the same cycle, poorly compensated: the corr_y of P5 and P6 and the corr_x of P7, P6 and P5 move clearly away from their night level during the day, then come back gradually in the evening. Deduced cause: the camera and its mount move with the heat of the day (camera pose); the structure, a masonry wall, is not supposed to move like that. No temperature is available to confirm it. Normal, nothing to do."}
|
|
{"start": "2026-10-29T10:45Z", "end": "2026-10-29T15:30Z", "family": "Visibility", "description": "By day (29/10), in the sun (full sun on the 12:00 image, sharp shadows on the wall): the corrected curves of the targets fluctuate from one measurement to the next much more than at night, with one-measurement jumps that come back at once, above all CV.4, F4.2, CV.6, BG.3 and BG.2;; CV.2 and CV.4 are rejected at times, their curves having gaps. The recognition error of most sensors, the references included, varies strongly from one measurement to the next, which it does not do at night nor on the overcast days (22/10, 26/10), when the curves stay calm. The jumps start late in the morning and stop in mid-afternoon. Deduced cause: heat shimmer, the air heated by the sun above the tracks and the ballast making the spots tremble (a fast noise over the whole scene, sunny hours only), not a nuisance seen on the images. Do not trust the small movements of these curves by day; this is not a movement of the structure."}
|
|
{"start": "2026-10-29T14:45Z", "end": "2026-10-29T15:15Z", "family": "No data", "description": "One measurement is missing for all sensors, all curves have a gap, although the 15:00 image exists. The power metrics of the station are empty over the whole month. The same gap occurs at the same time on the other stations that measure at that time (CLARIDEN, LENZSPITZE, NORDEND): a common cause outside the station (transmission or reception of the data), not a station failure; it is not established. The curves are missing over the range; nothing to do on the station.", "review": "2026-11-17"}
|
|
{"start": "2026-10-30T08:00Z", "end": "2026-10-31T07:45Z", "family": "Thermal displacement", "description": "Daytime thermal cycle (30/10): from the morning, the pan and the tilt of the camera drop and its scale rises, then they slowly come back in the afternoon, the evening and all night, until the start of the next morning. The corrected curves follow the same cycle, poorly compensated: corr_x of P7, P5, P6 and corr_y of P5, P6, P7, P4 move away from their night level during the day then come back, partly all at once at nightfall, when the recognition error also comes back (the lighting plays a part). Deduced cause: the camera and its mount move with the heat of the day (camera pose); the structure, a masonry wall, is not supposed to move like that. No temperature is available to confirm it. Normal, nothing to do.", "review": "2026-11-17"}
|
|
{"start": "2026-10-30T09:15Z", "end": "2026-10-30T15:30Z", "family": "Visibility", "description": "By day (30/10), in the sun (full sun on the 12:00 image, sharp shadows on the wall): the corrected curves of the targets fluctuate from one measurement to the next much more than at night, with one-measurement jumps that come back at once, above all CV.2, then F4.2, CV.6, F4.6, F4.5 and CV.4;; CV.2 and CV.4 are rejected at times, their curves having gaps. The recognition error of most sensors, the references included, varies strongly from one measurement to the next, which it does not do at night nor on the overcast days (22/10, 26/10), when the curves stay calm. The jumps start in mid-morning and stop in mid-afternoon. Deduced cause: heat shimmer, the air heated by the sun above the tracks and the ballast making the spots tremble (a fast noise over the whole scene, sunny hours only), not a nuisance seen on the images. Do not trust the small movements of these curves by day; this is not a movement of the structure."}
|
|
{"start": "2026-10-30T17:45Z", "end": "2026-10-30T18:15Z", "family": "Obstruction", "description": "One single measurement: most targets (the CV, the F4 and some of the P) are rejected and their curves are missing; the references are affected too (BG.3.1 and R1 rejected), the compensation retains none of them, and the targets that stayed under the threshold (BG.2, BG.3, F4.5 and some P) jump in corr_x and corr_y for the time of the measurement. Everything comes back at the next measurement. Cause: a passage in front of the targets and the references, a lit train passing: on the 18:00 night image, most of the spots have disappeared and large bright spots appear. The structure is not moving: point to ignore, nothing to do.", "review": "2026-11-17"}
|
|
{"start": "2026-10-30T18:15Z", "end": "2026-10-30T18:45Z", "family": "Obstruction", "description": "One single measurement: most targets (the CV, the F4 and some of the P) are rejected and their curves are missing; the references are affected too (BG.3.1 and R1 rejected), the compensation retains none of them, and the targets that stayed under the threshold (BG.2, BG.3, F4.5 and some P) jump in corr_x and corr_y for the time of the measurement. Everything comes back at the next measurement. Cause: a passage in front of the targets and the references, no image at that moment; deduced from the signature, the same as that of the trains seen on the images of the other passages. The structure is not moving: point to ignore, nothing to do.", "review": "2026-11-17"}
|
|
{"start": "2026-10-30T21:15Z", "end": "2026-10-30T22:00Z", "family": "Obstruction", "description": "Two measurements, at night (30/10): at 21:30, CV.2 is rejected, its curve is missing; the recognition error of the reference BG.3.1 rises markedly without crossing its threshold, the camera pose jumps (pan), and P3 clearly, P1 and BG.3 a little, jump in corr_x for the time of the measurement. At 21:45, F4.2 is rejected alone, its curve is missing; everything then comes back. Cause: probably a passage in front of the bottom of the scene and the reference BG.3.1, deduced from the signature, weaker than that of the trains (no image at that moment, the images being on the hour). The structure is not moving: point to ignore, nothing to do."}
|
|
{"start": "2026-10-31T07:45Z", "end": "2026-11-01T00:00Z", "family": "Thermal displacement", "description": "Daytime thermal cycle (31/10), sunny day (12:00 and 13:00 images): from the morning, the pan and the tilt of the camera drop and its scale rises; at 12:30 the tilt also makes a step, labelled separately (Displacement). In the afternoon and the evening the pan and the scale come back slowly, the tilt only partly. The corrected curves follow the cycle, poorly compensated: the corr_y of P6, P5 and P4 and the corr_x of P7 and P5 move clearly away from their night level during the day; in the evening P7 comes back, but the corr_y of P6 and P5 stays clearly above its level of the previous nights until the end of the range. Deduced cause: the camera and its mount move with the heat of the day (camera pose), plus the step of the camera; the structure, a masonry wall, is not supposed to move like that. No temperature is available to confirm it. Normal, nothing to do; see the step of 12:30."}
|
|
{"start": "2026-10-31T08:15Z", "end": "2026-10-31T16:00Z", "family": "Visibility", "description": "By day (31/10), in the sun (full sun on the 12:00 and 13:00 images, sharp shadows on the wall): the corrected curves of the targets fluctuate from one measurement to the next much more than at night, with one-measurement jumps that come back at once, above all CV.4, P2, CV.2 and P1, then BG.3 and F4.2;; CV.2 and CV.4 are rejected at times, their curves having gaps. The recognition error of most sensors, the references included, varies strongly from one measurement to the next, which it does not do at night nor on the overcast days (22/10, 26/10), when the curves stay calm. The jumps start in the morning and stop in late afternoon. Deduced cause: heat shimmer, the air heated by the sun above the tracks and the ballast making the spots tremble (a fast noise over the whole scene, sunny hours only), not a nuisance seen on the images. Do not trust the small movements of these curves by day; this is not a movement of the structure."}
|
|
{"start": "2026-10-31T12:15Z", "end": "2026-10-31T12:45Z", "family": "Displacement", "description": "Step of the camera at 12:30 on 31/10, in full sun (12:00 and 13:00 images): the tilt of the camera jumps at once, far more steeply than in its daily cycle, and all the sensors, references and targets, shift together in the image; the targets move relative to each other only a little. The compensation does not erase it all: the corr_y of P6, P7, P5 and P3 steps up clearly at that measurement and stays there all afternoon. The tilt does not come back to its earlier night level, and the corr_y of P6 and P5 stays clearly above its level of the previous nights until the end of the range; at 17:00 the corrections of the references BG.3.1, R1 and R2 also shift relative to each other and stay. Cause not established (the camera or its mount moving in the sun is likely). It is not a movement of the structure; the camera is to be monitored, and the level of the following nights checked."}
|