# How can I detect deformation of the reference network?
|
||||
|
||||
Camera-motion estimation provides a reprojection error called sigma0, which is available in the
|
||||
system metrics.
|
||||
Sigma0 measures how well the observed displacement of the different reference targets can be
|
||||
explained by the estimated global camera motion.
|
||||
An abnormal increase in sigma0 can therefore indicate that the reference network is deforming in
|
||||
a way that can no longer be explained by simple camera movement. A low value indicates that
|
||||
the observed movements of the reference targets remain consistent with a common camera
|
||||
movement.
|
||||
It is useful for monitoring the consistency and stability of the reference network and can be
|
||||
used to trigger further investigation if necessary.
|
||||
Sigma0 and the per-target Error Value provide complementary information:
|
||||
• Error Value checks whether an individual target is still visible and resembles its reference
|
||||
image;
|
||||
• sigma0 checks whether the reference targets remain geometrically consistent with the
|
||||
estimated camera movement.
|
||||
|
||||
Source : AIMsight FAQ, rév. 1.5
|
||||