@@ -0,0 +1,11 @@
# Station Guide — Relative Horizontal / Vertical [mm]
“Relative Horizontal” and “Relative Vertical” represent the horizontal and vertical displacement
of the tracked target relative to its reference position, expressed in millimetres.
When camera-motion correction is enabled, the estimated global movement of the camera is
removed from these values.
Practical use: These are the principal displacement values used for structural monitoring and
interpretation. They represent target movement after applying the configured image calibration
and, when enabled, camera-motion compensation.
Source : AIMsight Station Guide, rév. 1.5