# Station Guide — Measurement Range and Optical Options With 25 mm prisms, differential-mode measurements are possible at distances of up to approximately 200 m, subject to alignment, atmospheric conditions, background, target reflectivity, and exposure settings. Narrower-field-of-view lenses are available. They provide improved angular resolution and therefore better displacement precision at long range, at the cost of a smaller field of view and more demanding alignment. Refer to the applicable lens data sheet for the exact focal length, field of view, and expected precision. Source : AIMsight Station Guide, rév. 1.5