@@ -0,0 +1,6 @@
{"id": "JUNGFRAU-2026-11-06-D1", "debut": "2026-11-05T23:45Z", "fin": "2026-11-07T00:00Z", "categorie": "Obstruction", "description": "Détecteurs : Target obscured, PM_G, grisé. PM_G was hidden several times while the targets around it stayed clear. Ignore its curve in this period."}
{"id": "JUNGFRAU-2026-11-06-D2", "debut": "2026-11-05T23:45Z", "fin": "2026-11-06T12:30Z", "categorie": "Visibility", "description": "Détecteurs : Poor visibility, 15 capteurs. The camera saw 15 targets less clearly than usual, including the reference targets. The data in this period are less precise: use them with care. The jump of 4 targets in this period has the same cause."}
{"id": "JUNGFRAU-2026-11-06-D3", "debut": "2026-11-06T07:45Z", "fin": "2026-11-06T13:15Z", "categorie": "Thermal displacement", "description": "Détecteurs : Camera thermal expansion, 15 capteurs. The camera support expands in the day heat; the curves are corrected for it. This daily wave is normal: nothing to do."}
{"id": "JUNGFRAU-2026-11-06-D4", "debut": "2026-11-06T12:45Z", "fin": "2026-11-07T00:00Z", "categorie": "Thermal displacement", "description": "Détecteurs : Camera thermal contraction, 15 capteurs. The camera support contracts as it cools down; the curves are corrected for it. This daily wave is normal: nothing to do."}
{"id": "JUNGFRAU-2026-11-06-D5", "debut": "2026-11-06T15:45Z", "fin": "2026-11-07T00:00Z", "categorie": "Visibility", "description": "Détecteurs : Poor visibility, 15 capteurs. The camera saw 15 targets less clearly than usual, including the reference targets. The data in this period are less precise: use them with care. The jump of 2 targets in this period has the same cause."}
{"id": "JUNGFRAU-2026-11-06-D6", "debut": "2026-11-06T17:45Z", "fin": "2026-11-06T21:15Z", "categorie": "Visibility", "description": "Détecteurs : Heat shimmer, 11 capteurs. Warm air made the readings shake. The small fast wiggles are not movement."}