Optimizer : l'optimisation des détecteurs depuis une analyse (skill improve, ex wf-improve, agents du dépôt agents, benchmark detectors/bench) ; le batch et le scanner archivés
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
1 parent
010c297f60
commit
2cb0c88a2b
117 files changed
+132
-38
No files matched your search
@@ -0,0 +1,7 @@
|
||||
{"id": "LENZSPITZE-2026-11-12-D1", "debut": "2026-11-12T00:00Z", "fin": "2026-11-12T10:40Z", "categorie": "No data", "description": "Détecteurs : No data, tous les capteurs. No measurement in the export for 34 h 10 min (usually one every 5 min)."}
|
||||
{"id": "LENZSPITZE-2026-11-12-D2", "debut": "2026-11-12T09:00Z", "fin": "2026-11-12T23:00Z", "categorie": "Visibility", "description": "Détecteurs : Heat shimmer, 39 capteurs, grisé. Warm air made the readings shake. The small fast wiggles are not movement. The jumps of 31 targets in this period have the same cause."}
|
||||
{"id": "LENZSPITZE-2026-11-12-D3", "debut": "2026-11-12T10:40Z", "fin": "2026-11-12T10:40Z", "categorie": "Displacement", "description": "Détecteurs : Jump, not back yet, 101B. One target shifted and has not come back yet. Check whether the structure moved: look at the images."}
|
||||
{"id": "LENZSPITZE-2026-11-12-D4", "debut": "2026-11-12T10:40Z", "fin": "2026-11-12T21:25Z", "categorie": "Visibility", "description": "Détecteurs : Poor visibility, 22 capteurs. The camera saw 22 targets less clearly than usual, including the reference targets. The data in this period are less precise: use them with care."}
|
||||
{"id": "LENZSPITZE-2026-11-12-D5", "debut": "2026-11-12T11:55Z", "fin": "2026-11-12T11:55Z", "categorie": "Obstruction", "description": "Détecteurs : Brief obstruction, 18 capteurs, grisé. Something passed in front of 18 targets for a single measurement. Ignore this point on the curves."}
|
||||
{"id": "LENZSPITZE-2026-11-12-D6", "debut": "2026-11-12T11:55Z", "fin": "2026-11-12T23:55Z", "categorie": "Thermal displacement", "description": "Détecteurs : Camera thermal movement, 41 capteurs. The camera moved with a change of temperature and all the curves moved with it; this is not a movement of the structure, nothing to do."}
|
||||
{"id": "LENZSPITZE-2026-11-12-D7", "debut": "2026-11-12T22:20Z", "fin": "2026-11-12T22:20Z", "categorie": "Obstruction", "description": "Détecteurs : Brief obstruction, 8014, grisé. Something passed in front of one target for a single measurement. Ignore this point on the curves."}
|
||||
Reference in new issue
Block a user