Essai du 2026-11-05 : le batch, le scan, la première séance d'amélioration, l'audit du scanner et ses outils
batches/2026-11-05/ : détecteurs, vérité, rapport du scanner, improve/ (mesures, modification, validation, bilan, tools/instants.py de l'upgrader) ; docs/essais/ : le journal de l'essai et l'audit ; outils/ : les scripts de lecture de l'audit, réutilisables (JOUR=AAAA-MM-JJ). Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
1 parent
dab71a9037
commit
ed4cedbe70
47 files changed
+1490
No files matched your search
@@ -0,0 +1,25 @@
|
||||
# Validation
|
||||
|
||||
**Verdict**: keep
|
||||
|
||||
## Answers
|
||||
1. The detectors load: no `skipped` line in benchmark-before, S1, S2 or after; the benchmark rerun at HEAD is identical to benchmark-after.
|
||||
2. No station goes back: benchmark-before, -S1, -S2 and -after are identical, line for line, on all 11 stations and every family.
|
||||
3. The code stays simple and the gain justifies it. S1 replaces the median gap with a general measure, the cycle per clock hour. It adds no constant and removes 286 false No data instants (0 % correct) on SUSTENHORN. S2 reuses the existing "inside heat shimmer" filter for Poor visibility episodes of point 3, as a one-line change. It drops duplicate events, so the per-instant score does not move, but the same instants are no longer reported twice. Neither change is fitted to the range: no value is cut to its bounds.
|
||||
4. Nothing forbidden: the six detectors are unchanged in number and family, and `detect` keeps its signature and episode keys. Only the standard library is used and no constant was added. Station names appear only in the docstrings and `thresholds.md` as provenance, never in a rule. The `MISSING` line of `thresholds.md` is updated.
|
||||
|
||||
## The range
|
||||
SUSTENHORN, 2026-11-05 → 2026-11-06:
|
||||
- No data: correct 0/286 (0 %) → no instants flagged (the false day of No data is gone).
|
||||
- Every other family on SUSTENHORN, and all of BREITHORN and LENZSPITZE: unchanged.
|
||||
|
||||
Total: No data 0/286 → none. The other families are unchanged: Displacement 33/33, 33/36; Obstruction 31/66, 31/37; Thermal displacement 513/513, 513/519; Visibility 20/35, 20/34.
|
||||
|
||||
## Non-regression
|
||||
No line changed, on any station or family, between benchmark-before and benchmark-after (nor in benchmark-S1 or benchmark-S2). The `Total` block is unchanged: Displacement 5746/6345, 5746/20444; No data 75/836, 75/100; Obstruction 1044/4061, 1044/3718; Target issue 19080/22627, 19080/19467; Thermal displacement 10897/16142, 10897/14828; Visibility 3412/7207, 3412/4442.
|
||||
|
||||
## Reservations
|
||||
- No data, S1: the cadence step can only rise, so a station whose hours are only partly filled sees a longer step and needs a longer hole before it reports one. This costs nothing on the reference truth (No data 75/836 and 75/100, unchanged). Watch for missed short holes on stations with an irregular cadence.
|
||||
|
||||
## Tools
|
||||
none
|
||||
Reference in new issue
Block a user