# Validation **Verdict**: keep ## Answers 1. Detectors load: no `skipped` line in benchmark-before, -S1 or -after; rerunning the benchmark at HEAD gives output identical to benchmark-after. 2. No station goes back: only Thermal displacement changes, on JUNGFRAU, NORDEND and SNCF01. "Found" rises on all three. The worst "correct" drop is SNCF01, 95.5 → 94.0 (-1.5 points), which is under 2 points. 3. Simple and proportionate: one constant (`RETURN`) and one changed comparison in `_episodes`. The rule is generic: the cooling return ends at a lower share of the amplitude than the start does. The range gains +20 instants (56 → 77 %) and the whole benchmark gains +1089 found instants (68 → 74 %) while "correct" rises (73 → 75 %). The constant is not cut to the range's bounds. 4. Rules: still six detectors, one per family. Contract and episode keys are unchanged. No station-, sensor- or date-specific rule (station names appear only in provenance comments). Standard library only. `thresholds.md` has the new `RETURN` row and an updated `EDGE` row, matching the constants in the code. ## The range NORDEND 2026-11-05T00:00Z → 2026-11-06T00:00Z - Thermal displacement: found 53/95 (56 %) → 73/95 (77 %); correct 53/53 (100 %) → 73/73 (100 %) - Displacement, Obstruction, Target issue, Visibility: unchanged ## Non-regression - JUNGFRAU, Thermal displacement: found 1544/2557 (60 %) → 2300/2557 (90 %); correct 1544/1786 (86.4 %) → 2300/2654 (86.7 %) - NORDEND, Thermal displacement: found 4769/7667 (62 %) → 5066/7667 (66 %); correct 4769/5097 (93.6 %) → 5066/5411 (93.6 %) - SNCF01, Thermal displacement: found 1218/1726 (71 %) → 1254/1726 (73 %); correct 1218/1275 (95.5 %) → 1254/1334 (94.0 %) - Total, Thermal displacement: found 10897/16142 (68 %) → 11986/16142 (74 %); correct 10897/14828 (73 %) → 11986/16069 (75 %) ## Reservations none ## Tools none