Files
T

8.2 KiB

Modification

Verdict: changed Changed: scripts/ranges.py data.py: unchanged

What the analyst used

  • Tools: inventory.py, ranges.py --rolling 8, days.py (night levels, byhour), overview.py --rigid (29/09), summary.py (error_value, 1 h), plot.py, thumbnails.py, metrics.py.
  • Its own scripts, for a re-check of 94 existing labels against a "5 own noises" rule:
    • exceed.py: every target measurement more than K noises from its rolling level (the same computation as ranges.py --rolling 8 --instants 1), plus the labels covering each instant (to find the uncovered ones) and per label, the largest deviation strictly inside with the number of instants beyond K. It was the backbone of the 42 removals and 12 additions.
    • labeldev.py: the same per label, against the edge level as well (previous session).
    • thermal.py, days_dev.py: per day, the deviation of corr from the night level at "clean" instants (no reference lost except one named sensor, outside brief labels), with the longest run beyond K.
    • clipplot.py: corr in mm, 1st-99th percentile clipped, long labels shaded. build_labels.py: writes the file.
  • What it missed: no tool relates the corr deviations to a labels file. quality.py --labels/--outside does it only with the image quality metrics, which this station does not have. Its one documentation remark about the tools: measurement timestamps carry seconds, so comparing them with minute label bounds needs flooring.

Diagnosis

  • Label check by corr deviation (the main task of a re-check, and of any search for forgotten labels on a station without quality metrics): no tool does it. Cause: ranges.py computes the deviations per instant but knows nothing of labels; quality.py knows labels but only reads quality metrics. The analyst rewrote the ranges.py computation in exceed.py and labeldev.py just to add the labels.
  • Seconds in the timestamps against minute label bounds: a script that compares them directly counts a measurement at a bound as inside. Same cause: no tool did the comparison, so each script had to deal with it.
  • Day-by-day thermal deviation at clean instants (thermal.py, days_dev.py): partly covered by days.py --bounds and --smoothing. Excluding instants with a lost reference is general, but it needs a new mode for days.py, and the "except R3" choice was specific to this station.

What I decided

  • ranges.py: changed (S1). New option --labels F. It does what exceed.py did, with the computation ranges.py already has, so it works on any station.
  • exceed.py, labeldev.py (analyst): not added as scripts. ranges.py --labels replaces exceed.py (rolling level). labeldev.py's edge level is close to --rolling with a small N and was a secondary column.
  • thermal.py, days_dev.py (analyst): left where they are. days.py --bounds --smoothing covers the per-day deviation from the night level. The "clean instants" filter (no reference lost) would be a new days.py mode, and this one range is not enough to design it: see "Not fixed".
  • clipplot.py: left. plot.py plus corr_x_mm/corr_y_mm covers it. The percentile clipping did not block the analyst.
  • GUIDE.md: left untouched, as the request requires (already modified by someone else). The guide text for the option is under "For the user to decide".
  • Removals: none.

What changed

  • S1, commit f5ff319 in tools, scripts/ranges.py: new option --labels F (one JSON per line with start, end, family, and id if present, numbered in file order). Docstring section 4 and usage line added.
    • With --instants N, each instant line ends with | labels: <numbers> or | labels: none.
    • After that, a "Per label" table: number, id, start, end, family, and the number of measurement instants strictly inside (start < instant < end, instant floored to the minute). Then the largest deviation inside, from the level (rolling if --rolling): sensor.column, signed in noises, instant. Last, the number of instants inside where a sensor is more than --k noises off. A label with no measurement inside says so.
    • Without --labels, the output is byte-identical to before.

Why

  • A label re-check, or a search for forgotten labels on a station without quality metrics, asks two questions. What does each label hold beyond k noises? Which instants beyond k does no label cover? ranges.py already computed the deviations but could not answer either, so the analyst re-implemented it. The option answers both from the existing computation (| grep 'labels: none' lists the uncovered instants).
  • A measurement is compared with the bounds on its minute, strictly inside. A point at a bound (the point before or after) is not counted inside, even if its timestamp carries seconds.

Checks

  • python3 tools/scripts/ranges.py data/WILDSTRUBEL --columns corr_x,corr_y --rolling 8 --instants 1 --sensors PB1_2,PB2_2,PB4,PB_5,PA2_2,PA3_2,PA_9 --labels labeling/auto/analyses/WILDSTRUBEL_2026-09-24T0230_2026-10-06T1945/work/existing.jsonl --start 2026-09-24T02:30Z --end 2026-10-06T19:45Z → work/tools/ranges-labels-existing.txt, 0.5 s.
    • It reproduces the analyst's work/exceed.txt. Same two uncovered instants (24/09 02:30 PB2_2 cx+12; 03/10 05:00 PB1_2 cy+44). Same per-label maxima and counts, e.g. WILDSTRUBEL-94 PB4.cx +16.6, -96 PB1_2.cx +27.6, -87 +2.3, -115 +5.4, -120 to -127 identical. -111 (No data): no measurement inside.
  • The same with --min-measurements 6, no --instants, on the final labels.jsonl (no id) → work/tools/ranges-labels-new.txt. The per-label table prints - for the id, exit 0.
  • No PNG (ranges.py makes none).
  • python3 tools/scripts/quality.py --self-test: ok.
  • Without --labels, the old and new ranges.py give byte-identical output on --rolling 8 (the report's command) and on --columns corr_x,corr_y --rolling 8 --instants 2 (with a fixed PYTHONHASHSEED, see "Not fixed").

Report commands rerun: 1 (ranges.py --rolling 8 on the range → work/ranges_roll8.txt), no failure.

For the user to decide

  • GUIDE.md must document the new option in the same change (tools CLAUDE.md), but the request forbids touching GUIDE.md, so the option is committed without its guide text. Proposed text to add to the guide (by whoever commits GUIDE.md):
    • usage line of ranges.py: add [--labels F] before [--sensors A,B];
    • a bullet under ranges: "--labels F (one JSON per line, start, end, family, id if any): each line of --instants ends with the numbers of the labels that cover the instant (labels: none otherwise: | grep 'labels: none' lists the deviations no label holds); then, per label, the measurements strictly inside (start < instant < end, to the minute: a measurement at a bound is the point before or after), the largest deviation inside (sensor, column, noises, instant) and the number of instants beyond --k. To check a labels file against the curves: --columns corr_x,corr_y --rolling 8 --instants 1 --sensors <targets> --labels F."
  • Inside means strictly inside, on the minute, following the analyst's reading of the bounds (a label goes from the point before to the point after). quality.py --labels counts the bounds as inside. I kept the two tools apart rather than change quality.py.

Not fixed

  • Day-by-day deviation from the night level at "clean" instants, with the longest run beyond k (thermal.py). It could become a days.py --bounds filter: drop the instants where a retained reference is lost. That is a new mode, and this range alone does not settle which references to ignore (here, one always rejected by day). Wait for a second analysis that needs it.
  • ranges.py --instants: the order of the "rejected" list changes from one run to the next (it is built from a set, and string hashing varies between runs). It existed before this change, and the values are unaffected. A one-line fix (iterate names then references in order) if wanted.

Limits

none

Tools

none

Difficulties

  • The request forbids committing or reverting GUIDE.md, while the tools CLAUDE.md requires a new option to enter the guide in the same change. I committed the script alone and gave the guide text above.
  • The output folder already held another session's files (modification.md, validation.md, tools/). I only added tools.md and work/.