{"id": "LENZSPITZE-2026-11-05-D1", "debut": "2026-11-05T00:00Z", "fin": "2026-11-05T18:30Z", "categorie": "Thermal displacement", "description": "Détecteurs : Camera thermal movement, 41 capteurs. The camera moved with a change of temperature and all the curves moved with it; this is not a movement of the structure, nothing to do. The jump of 3 targets in this period has the same cause."}
{"id": "LENZSPITZE-2026-11-05-D2", "debut": "2026-11-05T02:35Z", "fin": "2026-11-05T02:50Z", "categorie": "Visibility", "description": "Détecteurs : Poor visibility, 35 capteurs. The camera saw 35 targets less clearly than usual, including the reference targets. The data in this period are less precise: use them with care. The jumps of 6 targets in this period have the same cause."}
{"id": "LENZSPITZE-2026-11-05-D3", "debut": "2026-11-05T02:40Z", "fin": "2026-11-05T02:40Z", "categorie": "Obstruction", "description": "Détecteurs : Brief obstruction, 1010, 7013B, 7013H, grisé. Something passed in front of 3 targets for a single measurement. Ignore this point on the curves."}
{"id": "LENZSPITZE-2026-11-05-D4", "debut": "2026-11-05T07:55Z", "fin": "2026-11-05T07:55Z", "categorie": "Obstruction", "description": "Détecteurs : Brief obstruction, 9 capteurs, grisé. Something passed in front of 9 targets for a single measurement. Ignore this point on the curves."}
{"id": "LENZSPITZE-2026-11-05-D5", "debut": "2026-11-05T08:20Z", "fin": "2026-11-05T08:35Z", "categorie": "Visibility", "description": "Détecteurs : Poor visibility, 28 capteurs. The camera saw 28 targets less clearly than usual, including the reference targets. The data in this period are less precise: use them with care. The jumps of 12 targets in this period have the same cause."}
{"id": "LENZSPITZE-2026-11-05-D6", "debut": "2026-11-05T09:55Z", "fin": "2026-11-05T09:55Z", "categorie": "Obstruction", "description": "Détecteurs : Brief obstruction, 92H, grisé. Something passed in front of one target for a single measurement. Ignore this point on the curves."}
{"id": "LENZSPITZE-2026-11-05-D7", "debut": "2026-11-05T14:40Z", "fin": "2026-11-05T14:50Z", "categorie": "Visibility", "description": "Détecteurs : Poor visibility, 26 capteurs. The camera saw 26 targets less clearly than usual, including the reference targets. The data in this period are less precise: use them with care. The jumps of 5 targets in this period have the same cause."}
{"id": "LENZSPITZE-2026-11-05-D8", "debut": "2026-11-05T21:20Z", "fin": "2026-11-05T23:55Z", "categorie": "Displacement", "description": "Détecteurs : Jump, not back yet, 16 capteurs. 16 targets shifted and have not come back yet. Check whether the structure moved: look at the images."}
{"id": "LENZSPITZE-2026-11-05-D9", "debut": "2026-11-05T22:55Z", "fin": "2026-11-05T23:55Z", "categorie": "Visibility", "description": "Détecteurs : Poor visibility, 27 capteurs. The camera saw 27 targets less clearly than usual. The data in this period are less precise: use them with care."}