Files
aimsight-optimizer/batches/2026-11-12/verite/JUNGFRAU.jsonl
T
maximeandClaude Opus 5.5 bcd65c3b00 Optimizer : un batch de 24 h, les détecteurs, leurs figures et le scanner
Les détecteurs (le dépôt detectors, en sous-module) passent sur un jour UTC de
toutes les stations ; leurs étiquettes et une figure par station vont dans
batches/<jour>/ ; le scanner (Sonnet) note les irrégularités dans rapport.md
et les corrige dans verite/. Premier batch : 2026-11-12. L'amélioration par
/detectors:wf-improve n'est pas encore branchée.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-13 16:24:49 +01:00

7 lines
1.8 KiB
JSON

{"id": "JUNGFRAU-2026-11-12-D1", "debut": "2026-11-12T00:00Z", "fin": "2026-11-12T23:45Z", "categorie": "Obstruction", "description": "Détecteurs : Target obscured, PM_G, grisé. PM_G was hidden several times while the targets around it stayed clear. Ignore its curve in this period."}
{"id": "JUNGFRAU-2026-11-12-D2", "debut": "2026-11-12T00:00Z", "fin": "2026-11-12T10:45Z", "categorie": "No data", "description": "Détecteurs : No data, tous les capteurs. No measurement in the export for 34 h 30 min (usually one every 15 min)."}
{"id": "JUNGFRAU-2026-11-12-D3", "debut": "2026-11-12T08:00Z", "fin": "2026-11-12T13:00Z", "categorie": "Thermal displacement", "description": "Détecteurs : Camera thermal expansion, 15 capteurs. The camera support expands in the day heat; the curves are corrected for it. This daily wave is normal: nothing to do. The jump of 5 targets in this period has the same cause."}
{"id": "JUNGFRAU-2026-11-12-D4", "debut": "2026-11-12T11:45Z", "fin": "2026-11-12T19:30Z", "categorie": "Visibility", "description": "Détecteurs : Poor visibility, 10 capteurs. The camera saw 10 targets less clearly than usual, including the reference targets. The data in this period are less precise: use them with care. The jump of 3 targets in this period has the same cause."}
{"id": "JUNGFRAU-2026-11-12-D5", "debut": "2026-11-12T13:00Z", "fin": "2026-11-12T23:45Z", "categorie": "Thermal displacement", "description": "Détecteurs : Camera thermal contraction, 15 capteurs. The camera support contracts as it cools down; the curves are corrected for it. This daily wave is normal: nothing to do."}
{"id": "JUNGFRAU-2026-11-12-D6", "debut": "2026-11-12T20:15Z", "fin": "2026-11-12T22:45Z", "categorie": "Displacement", "description": "Détecteurs : Sudden jump, back to normal, PM_D. One target jumped and came back. The cause is not established: look at the images."}