tools: the reading harness of the AIMsight agents (`README.md`), and nothing else. The user guide is `GUIDE.md`; a new tool or a new option goes into it in the same change, a removed one leaves it in the same change. `DATA.md` (what the data are) is maintained by hand by the user; `GUIDE.md` is the upgrader's (`agents` repository, run by Optimizer's `optimize` skill).
- **Checking a change**: rerun the touched tool from a calling repository (aimsight-app: `python3 tools/scripts/<tool>.py data/<STATION> --start … --end …`), and the commands of the guide that use it; `python3 tools/scripts/quality.py --self-test` (from the calling repository).
- Break nothing by accident: the analyses' reports cite commands, so a change keeps the existing options and outputs working; only a removal (below) may break one, and its report gives the command that replaces it.
- Add, change or remove. A sentence of the guide is changed or removed freely. A tool (or one of its options or outputs) is removed only for a good reason, said in the change's report: it is superseded (another tool, or an option of one, now shows the same: nothing is lost), or it is wrong (false values, a judgement in its output) and fixing it costs more than it is worth. Not a reason: it did not help on one range; it may help on another, and a single analysis is not enough to clean the list. Never removed by a change to improve the tools, only proposed to the user: `data.py`, `common.py`, a tool named outside this repository (`README.md`, aimsight-app's `instructions/analyst.md`).
- The simplest first: a sentence of the guide or a better default; otherwise an option of an existing tool; a new tool as a last resort. A new script has a docstring at the top, like the others, and enters the table of `GUIDE.md` in the same change.
-`scripts/data.py` is the one reader of the station data, shared by the app, the tools and the detectors (which import it: benchmark, Optimizer): touch it only to fix a reading error, never remove or rename a public name. A change to it changes the detectors' benchmark: rerun `python3 detectors/bench/regression.py --labels labeling/auto --data data` from aimsight-app, and say the change at the top of the change's report. Standard library only, no import from the other scripts.
-`scripts/common.py`: what the tools share beyond reading (columns, steps, noise, sensor list, runs, file names); standard library, no matplotlib (some tools run with `python3`). A tool imports `data` and `common`, never another tool.