Add the loop's end-of-session page and a detector benchmark on the case base

- End-of-session page for /boucle: the session's curves, the analyst's
  labels against the detectors' events per category, a plain score table
  and the benchmark (comparaison.py, D-066)
- Detectors moved to vues-deplacements/detectors/ (D-067)
- Detectors must detect everything; what the client sees is a separate
  layer (D-068)
- Benchmark: each case keeps its labels from creation (etiquettes.json),
  benchmark.py scores the detectors on every case, history in
  vues-deplacements/benchmark/historique.csv; run by /boucle at each lot,
  after each change and at the end, read by the upgrader and validator;
  labels for C-001..C-005 from one analyst pass corrected by their files,
  C-006..C-008 from lot 01 (D-069)
- Fixes from the releveur's notes: /boucle arguments and other sessions,
  branch name in the spec, detector name in categories.py output, learned
  case header, anonymiser.py (camera/, no empty CSVs, --etiquettes),
  ensemble.py (clock-aligned steps, title), plages.py (same-sign merge),
  labeling request written into /nouveau-cas
- Also carries the other session's uncommitted D-065 edits in the same
  files; data/, .gitignore, pomper.py and stations.py are left out

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
maximeandClaude Opus 5.5 committed 2026-10-26 16:48:13 +01:00
1 parent 6b3d058a67
commit d5bae7a696
57 files changed
+1727 -157

No files matched your search

@@ -0,0 +1,61 @@
{"station": "C-001", "debut": "2026-10-08T22:00Z", "fin": "2026-10-14T10:00Z", "moments": [
{"debut": "2026-10-08T22:00Z", "fin": "2026-10-14T09:45Z", "capteurs": ["C12"],
"categorie": "aucune", "evenement": null, "preuve": "deduite",
"description": "C12 rejetée à toutes les mesures : error_value 0,41, au-dessus de son seuil de 0,3, avec le même cycle jour/nuit que les autres cibles ; pas de courbe corrigée.", "apres_detecteurs": false},
{"debut": "2026-10-08T22:00Z", "fin": "2026-10-09T07:45Z", "capteurs": ["C1", "C2", "C3", "C4", "C5", "C6", "C7", "C8", "C9", "C10", "C11"],
"categorie": "contraction_thermique", "evenement": "Daily thermal cycle", "preuve": "deduite",
"description": "Fin du retour de nuit de la vague journalière : corr_y remonte lentement jusqu'au matin (C7 +0,37, C1 +0,51).", "apres_detecteurs": false},
{"debut": "2026-10-09T01:00Z", "fin": "2026-10-09T01:00Z", "capteurs": ["R1", "R2", "R3", "C1", "C2", "C4", "C8", "C11"],
"categorie": "saut_bref", "evenement": null, "preuve": "deduite",
"description": "Saut de la compensation d'une seule mesure : corr_x des références (8 à 11 bruits) et de plusieurs cibles (C11 −12 bruits), retour à 01:15.", "apres_detecteurs": false},
{"debut": "2026-10-09T08:00Z", "fin": "2026-10-09T15:30Z", "capteurs": ["C1", "C2", "C3", "C4", "C5", "C6", "C7", "C8", "C9", "C10", "C11"],
"categorie": "dilatation_thermique", "evenement": "Daily thermal cycle", "preuve": "deduite",
"description": "Phase chaude : corr_y descend (C7 −0,60, C11 −0,43), bosse de corr_x (C3 +0,55, C7 +0,49) ; positions brutes en mode commun le jour, error_value ordinaire.", "apres_detecteurs": false},
{"debut": "2026-10-09T12:00Z", "fin": "2026-10-09T12:00Z", "capteurs": [],
"categorie": "trou", "evenement": "No data", "preuve": "deduite",
"description": "Une mesure absente pour tous les capteurs.", "apres_detecteurs": false},
{"debut": "2026-10-09T15:45Z", "fin": "2026-10-10T08:00Z", "capteurs": ["C1", "C2", "C3", "C4", "C5", "C6", "C7", "C8", "C9", "C10", "C11"],
"categorie": "contraction_thermique", "evenement": "Daily thermal cycle", "preuve": "deduite",
"description": "Retour de la vague : corr_y remonte lentement toute la nuit, corr_x revient de sa bosse.", "apres_detecteurs": false},
{"debut": "2026-10-10T08:15Z", "fin": "2026-10-10T16:45Z", "capteurs": ["C1", "C2", "C3", "C4", "C5", "C6", "C7", "C8", "C9", "C10", "C11"],
"categorie": "dilatation_thermique", "evenement": "Daily thermal cycle", "preuve": "deduite",
"description": "Phase chaude plus faible en corr_x ; corr_y C7 −0,46, C1 −0,59 ; à 12:30-12:45 error_value des cibles en hausse deux mesures et pas de corr_y de C1, C3.", "apres_detecteurs": false},
{"debut": "2026-10-10T10:45Z", "fin": "2026-10-10T10:45Z", "capteurs": [],
"categorie": "trou", "evenement": "No data", "preuve": "deduite",
"description": "Une mesure absente pour tous les capteurs.", "apres_detecteurs": false},
{"debut": "2026-10-10T17:00Z", "fin": "2026-10-11T07:45Z", "capteurs": ["C1", "C2", "C3", "C4", "C5", "C6", "C7", "C8", "C9", "C10", "C11"],
"categorie": "contraction_thermique", "evenement": "Daily thermal cycle", "preuve": "deduite",
"description": "Retour de nuit de la vague ; à 18:00 une mesure où l'error_value de nombreuses cibles monte un peu, retour à 18:15.", "apres_detecteurs": false},
{"debut": "2026-10-11T08:00Z", "fin": "2026-10-11T17:30Z", "capteurs": ["C1", "C2", "C3", "C4", "C5", "C6", "C7", "C8", "C9", "C10", "C11"],
"categorie": "dilatation_thermique", "evenement": "Daily thermal cycle", "preuve": "deduite",
"description": "Phase chaude : corr_y C7 −0,43 ; bosse de corr_x moyenne (C3 +0,29, C7 +0,24).", "apres_detecteurs": false},
{"debut": "2026-10-11T17:45Z", "fin": "2026-10-12T07:15Z", "capteurs": ["C1", "C2", "C3", "C4", "C5", "C6", "C7", "C8", "C9", "C10", "C11"],
"categorie": "contraction_thermique", "evenement": "Daily thermal cycle", "preuve": "deduite",
"description": "Retour de nuit ; corr_y au matin le plus haut du lot (C7 +0,70).", "apres_detecteurs": false},
{"debut": "2026-10-12T07:30Z", "fin": "2026-10-12T17:15Z", "capteurs": ["C1", "C2", "C3", "C4", "C5", "C6", "C7", "C8", "C9", "C10", "C11"],
"categorie": "dilatation_thermique", "evenement": "Daily thermal cycle", "preuve": "deduite",
"description": "Phase chaude la plus forte : corr_x C7 +0,73, C1 +0,54, C3 +0,71 vers 14:30-15:45 ; corr_y C7 −0,64, C11 −0,46.", "apres_detecteurs": false},
{"debut": "2026-10-12T16:00Z", "fin": "2026-10-12T16:00Z", "capteurs": ["R1", "R2", "R3", "C3", "C6", "C7"],
"categorie": "saut_bref", "evenement": null, "preuve": "deduite",
"description": "Saut de la compensation d'une mesure (corr_x R1 −8 bruits, C3 −0,13), retour à 16:15 ; error_value de R3 ×2,7 à 16:00, de R1 en pic à 15:30 et 16:15.", "apres_detecteurs": false},
{"debut": "2026-10-12T17:30Z", "fin": "2026-10-13T07:00Z", "capteurs": ["C1", "C2", "C3", "C4", "C5", "C6", "C7", "C8", "C9", "C10", "C11"],
"categorie": "contraction_thermique", "evenement": "Daily thermal cycle", "preuve": "deduite",
"description": "Retour de nuit de la vague (C7 +0,58 au matin).", "apres_detecteurs": false},
{"debut": "2026-10-13T00:00Z", "fin": "2026-10-13T04:00Z", "capteurs": ["R2", "R3"],
"categorie": "visibilite_reduite", "evenement": "Rain or fog", "preuve": "deduite",
"description": "Deux références dehors moins bien vues : R3 jusqu'à 0,55 (+245 bruits), R2 jusqu'à 0,42, sans rejet ; sigma0 ×1,3, corr des références et de C3 décalés ; retour sans palier.", "apres_detecteurs": false},
{"debut": "2026-10-13T07:15Z", "fin": "2026-10-13T16:30Z", "capteurs": ["C1", "C2", "C3", "C4", "C5", "C6", "C7", "C8", "C9", "C10", "C11"],
"categorie": "dilatation_thermique", "evenement": "Daily thermal cycle", "preuve": "deduite",
"description": "Phase chaude : corr_y C7 −0,44 ; corr_x faible malgré la médiane brute x la plus haute.", "apres_detecteurs": false},
{"debut": "2026-10-13T16:45Z", "fin": "2026-10-14T07:30Z", "capteurs": ["C1", "C2", "C3", "C4", "C5", "C6", "C7", "C8", "C9", "C10", "C11"],
"categorie": "contraction_thermique", "evenement": "Daily thermal cycle", "preuve": "deduite",
"description": "Retour de nuit de la vague, mêlé à l'épisode de R2, R3.", "apres_detecteurs": false},
{"debut": "2026-10-13T23:45Z", "fin": "2026-10-14T05:15Z", "capteurs": ["R2", "R3"],
"categorie": "visibilite_reduite", "evenement": "Rain or fog", "preuve": "deduite",
"description": "R3 jusqu'à 0,67, R2 jusqu'à 0,69 (au ras du seuil 0,7), R1 intacte ; sigma0 ×1,5 ; paliers de corr_x des cibles à l'entrée et à la sortie de R3 (C3 −0,35 à 03:45) ; vignettes : taches de R2, R3 réduites à un point, témoins inchangés ; brume ou buée déduite, pas vue (fiche).", "apres_detecteurs": false},
{"debut": "2026-10-14T07:45Z", "fin": "2026-10-14T09:45Z", "capteurs": ["C1", "C2", "C3", "C4", "C5", "C6", "C7", "C8", "C9", "C10", "C11"],
"categorie": "dilatation_thermique", "evenement": "Daily thermal cycle", "preuve": "deduite",
"description": "Début de la phase chaude, jusqu'à la fin du lot.", "apres_detecteurs": false},
{"debut": "2026-10-14T09:30Z", "fin": "2026-10-14T09:30Z", "capteurs": [],
"categorie": "trou", "evenement": "No data", "preuve": "deduite",
"description": "Une mesure absente pour tous les capteurs.", "apres_detecteurs": false}]}