The night end and rise were anchored on the first daily maximum,
which can be the 00:00 tail of the previous evening: 2026-05-05 was
read NO_CHARGE despite a +0.079 V rise, 2026-09-30 showed a wrong
night end, and 2026-09-26 stayed unknown from 04:00 to 11:00 when
evaluated mid-day. The rise now starts from an earlier minimum and
the knee is tested on the daily minimum (min_v). VERMONT: 139 / 31 /
14 / 0.
Docs: sheet 02 page order, battery_state.py in the CLAUDE.md map,
phase C exception to "anomaly = None means UNKNOWN".
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
One state per UTC day from BusVoltage: FULL_CHARGE, BELOW_PLATEAU,
NO_CHARGE, PARTIAL_CHARGE or unknown, with hardware thresholds
(14.0 V end of charge, 12.8 V LiFePO4 knee). No verdict yet.
Includes the implementation plan.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>