Commit Graph
8 Commits
Author SHA1 Message Date
maximeandClaude Opus 5.5 fc74fec10f Add the day color matrix, the energy diagnostic manual and the site figure
D-020: the delivered energy diagnostic keeps analyses 03 and 04 only,
combined by the state x trend matrix of cas-d-usage-03-04.drawio into
one color per day (green / orange / red, grey when unknown), coded in
src/day_color.py (standard library). docs/guide/diagnostic-energetique.md
explains it: part 1 for the client, part 2 for support.

D-021: energy_plot.daily_figure builds the figure for the monitoring
site (panel 03 above panel 04, shared time axis), written by
analyse_01.py as out/<STATION>_daily.html and .json. battery_state no
longer imports energy_check, so analyses 03 and 04 ship on their own.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-12 16:23:21 +02:00
maximeandClaude Opus 5.5 129d4ff59b Plot daily analysis points at noon of their day
Analyses 03 and 04 now place each day's point and bar at 12:00 UTC
instead of 23:00, where they read as the next day. Computations are
unchanged. D-019 records the choice and the rejected one-day shift of
the night-end voltage (tried in 03, then in 04 only); sheet 04 gains
limit 6 (night end of J reflects J-1), and the data-pitfalls note
explains why.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-12 12:11:45 +02:00
maximeandClaude Opus 5.5 e058a2e3e7 Plot DAILY_BATTERY_TREND as the fourth analysis panel
One bar per day for the night-end voltage delta, coloured by trend
(blue better, grey stable, red worse), with the 0.05 V dead band.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-12 11:35:40 +02:00
maximeandClaude Opus 5.5 a3590fab62 Plot DAILY_BATTERY_STATE as the third analysis panel
Daily maximum and night-end voltage, 14.0 V and 12.8 V thresholds,
one marker colour and symbol per day state.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-12 10:52:40 +02:00
maximeandClaude Opus 5.5 9be9a636f7 Shade battery state voltage zones on the BusVoltage plot
Background bands for discharge (12.0-13.2 V), charging (13.1-13.8 V)
and full charge (14.0-14.4 V), from the battery voltage report.
Display only, no effect on the analyses.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-12 10:45:43 +02:00
maximeandClaude Opus 5.5 7b1da6d7cf Add analysis 02 (midnight sample), simplify plots, spell out rule names
- Analysis 02 MOVING_AVERAGE_7_DAYS_MIDNIGHT_UTC_DROP: same rule as
  analysis 01 on the 00:00 UTC BusVoltage sample only, one point per
  day. Shared computation in energy_check._ma_drop(); analysis 01
  results unchanged on VERMONT.
- Common page: one panel per analysis (02 under 01), then the time
  series (D-016); src/analyse_02.py launches that page.
- Analysis panel reduced to two curves on one volt axis: 7-day mean
  and threshold; gap and reference moved to hover (D-015).
- Date tick labels under every subplot.
- Rule IDs spelled out: MA7D_DROP -> MOVING_AVERAGE_7_DAYS_DROP,
  MA7D_MIDNIGHT_DROP -> MOVING_AVERAGE_7_DAYS_MIDNIGHT_UTC_DROP (D-017).
- Docs: analysis sheet 02, sheet 01, CLAUDE.md, README, decisions
  D-015..D-017, analysis rule and nouvelle-analyse skill.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-12 09:31:52 +02:00
maximeandClaude Opus 5.5 0b950199b8 Rework analysis 01 entry point and plots, drop tests
- src/analyse_01.py: single entry point, analyses data/, writes and
  opens the HTML report (switches to .venv for plotly).
- Plot: analysis on top, one subplot per time series below; zoom in
  time only, y axes rescaled to the visible range on every zoom.
- Tests removed: experimental prototype phase (D-008).
- Ignore __pycache__/.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-09 23:29:42 +02:00
maximeandClaude Opus 5.5 79bd98c9cb Add plotly HTML report for MA7D_DROP
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-09 19:27:28 +02:00