auto: the analysts verified the labels of 32 periods (11 stations, up to 14 days each): 710 labels -> 835, 587 unchanged; one analysis folder per period with its report (section Verification)
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
1 parent
df979301b5
commit
2a5d87659b
279 files changed
+10758
-710
No files matched your search
@@ -0,0 +1,116 @@
|
||||
# Labels: CLARIDEN, 2026-10-11T00:00Z → 2026-10-20T04:00Z (UTC)
|
||||
|
||||
The task was to verify the 8 existing labels of the range (`work/existing.jsonl`). The 2 labels that span the range (`work/spanning.jsonl`) are context only. Station: a tunnel under construction, cadence 10 min, five references (D-302-C, PR-291, PR-293, PR-295, PR-296). PR-296 is retained by the compensation at every instant, although `stations.md` lists four references. There are no image-quality metrics (inventory: export peak to snr empty), so `quality.py` does not apply. Images: one per hour, always dark (night-like infrared view).
|
||||
|
||||
**Weather**: none. There is no `data/CLARIDEN/weather/` folder and no CLARIDEN line in `~/aimsight-data/extraction/stations.txt`: the station has no Swiss position. In any case it is in a tunnel.
|
||||
|
||||
## Verdict per old id
|
||||
|
||||
| id | verdict | evidence |
|
||||
|---|---|---|
|
||||
| CLARIDEN-15 | **corrected** (end, description) | 3 h medians: D-304-C corr_y goes from about −0.48 (14th–15th) to −0.494 at the first steps after the gap of the 16th (10:30), then stays at −0.49…−0.50 until the 17th. D-303-C goes from −0.13 to −0.14…−0.147 and stays there. D-301-C corr_x has been flat around −0.08…−0.09 since the 14th. The return is over at 2026-10-16T12:00Z; afterwards it is a plateau, and a plateau is not a return (labeling-rules §2). The further dip of D-303-C and D-304-C on 18–19 follows the camera tilt and comes back at the jump of the 20th 00:30, so it belongs to the new tilt label. The description said "No camera movement during these days", but the tilt rises from about −2 to +0.3 thousandths of a degree on the 11th–13th and falls to −4.6 on the 19th. |
|
||||
| CLARIDEN-16 | **corrected** (start 22:45 → 22:50) | Last measurement before the gap: 22:50 (inventory: "between 22:50 and 10:30: 69 missing"). 22:45 is not a measurement instant at a 10 min cadence. The description is kept. |
|
||||
| CLARIDEN-17 | **kept** | Single missing step 14:30; bounds 14:20 → 14:40 are measurement instants; metrics normal (BusVoltage ~14.36 V). |
|
||||
| CLARIDEN-18 | **corrected** (start 09:00 → 08:50, description) | At 09:00 the row A targets are already up in corr_y: D-300-A +0.075, D-302_A +0.095, D-303-A +0.098, D-304-A +0.004 (usual about −0.065), D-301-A −0.056 (usual −0.12) and P-298-A +0.053, each about +3 to +3.5 noises, together. D-302-B is at 0.094. At 09:10–09:20, error_value rises on 9 to 11 sensors (PR-293, PR-295, D-300-C, D-301-C, D-302-B, D-303-B, D-303-C, D-304-B…). D-302-B/PR_BG corr_y reaches 0.154 (+8 noises), D-301-C corr_x −0.21 (−9 noises), P-301-B corr_x +0.05. Everything is back at 09:30. The 09:00 image shows nothing in front of the targets (looked at; same as 08:00). Family Visibility kept: sharp edges and an error_value rising on most sensors, like the reviewed CLARIDEN-12. The old text named neither the row A targets nor the 09:00 image. |
|
||||
| CLARIDEN-19 | **corrected** (start 13:45 → 13:50) | The last measurement is 13:50. Metrics: none from 15:00 to 21:00 (metrics.py), BusVoltage 13.26 V at the restart then rising: the description holds. |
|
||||
| CLARIDEN-20 | **corrected** (end 10:15 → 10:10) | Present instants: 09:00, 09:30, 09:50, 10:10. The first measurement after the last gap is 10:10. |
|
||||
| CLARIDEN-21 | **corrected** (start 20:45 → 20:40) | Present: 20:40, 21:10, 21:30; the gap starts after 20:40. |
|
||||
| CLARIDEN-22 | **corrected** (bounds 00:15→00:45 → 00:10→00:40, description) | Raw y of the targets: −0.0325 at 00:10, +0.005 at 00:20 (already moving), +0.165 at 00:30, then a plateau. The tilt goes from −0.0027 to −0.0012 to +0.0023. The new level is reached at 00:30, so the end is 00:40. In corr_y, D-306-B goes 0.034 → 0.105 (+7 noises) and stays, beyond its level of the 16th–17th (≈0.05). D-303-C goes −0.157 → −0.124, D-304-C −0.518 → −0.477, D-304-B −0.075 → −0.058, P-301-B and D-303-B also rise: these jumps bring them back to their level of before the 17th, so the jump erases the tilt remainder. D-302-B/PR_BG jump in corr_x (2 h medians 0.064 → 0.090 → 0.101) and do not jump in corr_y. The old description ("D-303-C, D-302-B and PR_BG a smaller jump that remains") was wrong on the nature of most of the jumps. Images of 00:00 and 01:00: work lights at the far end of the tunnel, nothing in front of the targets. |
|
||||
|
||||
**Spanning labels** (not changed):
|
||||
- **CLARIDEN-1** (P-300-B Target issue): holds in the range. P-300-B is rejected at all 1187 instants (inventory), with error_value about 0.93.
|
||||
- **CLARIDEN-14** (drift of the 6th–11th, ends 11th 06:00): its in-range part (11th 00:00–06:00) is a plateau, which is consistent. But its sentence "No camera movement" is contradicted just before the range: the tilt goes from +0.8 (9th 00h) to −2.0 (11th) thousandths of a degree (6 h table, `work/tilt_vs_targets_6h.txt`), and D-306-B corr_y follows it down (0.045 → 0.022). This is outside my range (9th–11th); it is to be checked by whoever verifies the range of the 6th–11th.
|
||||
|
||||
## 1. My labels
|
||||
|
||||
### 2026-10-11T06:00Z → 2026-10-16T12:00Z (CLARIDEN-15, corrected)
|
||||
- **Phenomenon of the catalogue**: Targets move slowly, alone, then come back (return part).
|
||||
- **Precedents**: CLARIDEN-14 (its outward), reviewed.
|
||||
- **Family**: Displacement. No cause is established, and the movement does not follow the temperature (housing at 40.0–40.4 °C).
|
||||
- **Measured**: 3 h medians (above). D-301-C corr_x −0.042 (11th) → −0.08/−0.09 (14th–15th). D-303-C corr_y −0.12 → −0.145, and D-304-C −0.455 → −0.495, reached at 16th 09:00–12:00. These movements do not follow the tilt: they continue on the 13th–15th while the tilt is flat around 0.
|
||||
- **Images**: 13th 12:00, a whole-zone thumbnail: nothing in front of the targets.
|
||||
- **Confidence**: medium. The end is read on medians of about 0.01 px steps, close to the noise (MAD 0.011 per measurement).
|
||||
|
||||
### 2026-10-15T22:50Z → 2026-10-16T10:30Z (CLARIDEN-16, corrected start)
|
||||
- **Phenomenon**: A gap common to several stations, plus a station restart on its battery (as described).
|
||||
- **Family**: No data. **Measured**: 69 missing steps; no metrics 00:00–09:00; BusVoltage 13.3 V at the restart, then 14.36 V. **Images**: none from 22:00 to 10:30. **Confidence**: high.
|
||||
|
||||
### 2026-10-16T14:20Z → 2026-10-16T14:40Z (CLARIDEN-17, kept)
|
||||
No data, one step; high confidence.
|
||||
|
||||
### 2026-10-18T08:50Z → 2026-10-18T09:30Z (CLARIDEN-18, corrected)
|
||||
- **Phenomenon**: Visibility drops over the whole scene, without an obstacle (by its signature); like CLARIDEN-12.
|
||||
- **Precedents**: CLARIDEN-12 (reviewed Visibility, same group D-301-C, D-302-B/PR_BG, D-304-B).
|
||||
- **Family**: Visibility rather than Displacement. The error_value rises on most sensors, including references, with sharp edges (families.md boundary "Thermal or Visibility"). The pose jump comes with it.
|
||||
- **Measured**: values above; the camera tilt goes −0.0012 → −0.0028 → −0.0038 → −0.0025 → −0.0008 (08:50 → 09:30). The housing temperature drops to 39.6 °C on the 08:00–10:00 step.
|
||||
- **Images**: 08:00 and 09:00, whole image: identical, nothing in front.
|
||||
- **Confidence**: medium. The bounds are sure; the cause is deduced, not seen.
|
||||
|
||||
### 2026-10-18T13:50Z → 2026-10-18T23:30Z (CLARIDEN-19, corrected start)
|
||||
No data; signature of a power cut (low voltage at the restart). High confidence.
|
||||
|
||||
### 2026-10-19T09:00Z → 2026-10-19T10:10Z (CLARIDEN-20) and 2026-10-19T20:40Z → 2026-10-19T21:30Z (CLARIDEN-21), corrected bounds
|
||||
No data; the common gaps with other stations are as described (not re-read on the other stations: the descriptions were validated). High confidence on the bounds.
|
||||
|
||||
### 2026-10-20T00:10Z → 2026-10-20T00:40Z (CLARIDEN-22, corrected)
|
||||
- **Phenomenon**: A step of the camera that the compensation does not erase.
|
||||
- **Precedents**: WILDSTRUBEL-200 (a camera tilt not caught by the compensation, Displacement).
|
||||
- **Family**: Displacement. The cause of the camera step is not established, and remainders stay on D-306-B and D-302-B.
|
||||
- **Measured**: above (native table `summary.py --column corr_y --step 10min`, 19th 23:30 → 20th 01:30).
|
||||
- **Images**: 00:00 and 01:00 (zone thumbnails): work lights at the far end of the tunnel.
|
||||
- **Confidence**: high on the jump; medium on what stays.
|
||||
|
||||
### 2026-10-11T08:50Z → 2026-10-11T09:10Z (new)
|
||||
- **Phenomenon**: none in the catalogue exactly. It is close to "The base changes without a reference lost", for a single measurement.
|
||||
- **Precedents**: none useful.
|
||||
- **Family**: Displacement: a jump then the return, without an established cause. The error_value is flat, so it is not Visibility.
|
||||
- **Measured**: `scripts/group_flips.py`: 10 targets beyond 3 noises downward in corr_y at 09:00 (D-304-A −5.7, D-301-A −5.5, D-303-A −4.5, D-301-C −4.2, D-302_A −3.9, D-302-B/PR_BG −3.8, P-299-B −3.7, P-301-B −3.3, P-299-A −3.2). Raw values: D-301-A −0.212 against −0.11 around; D-304-A −0.176 against −0.05. Rigid fit (base 08:00): ty +0.063 and rotation −0.00114 at 09:00. D-302-C dy −0.010 against +0.04…+0.09 for the other references. The camera rotation hits its window minimum (−0.0054°) at 09:00. All is back at 09:10.
|
||||
- **Images**: 09:00 (zone thumbnail): nothing in front.
|
||||
- **Confidence**: medium. It is clearly a common one-measurement jump, but small (about 0.1 px).
|
||||
|
||||
### 2026-10-11T14:00Z → 2026-10-13T02:00Z (new)
|
||||
- **Phenomenon**: The camera tilts little by little (here it straightens).
|
||||
- **Precedents**: BREITHORN-2 and BREITHORN-11 (reviewed): slow tilt, incomplete compensation, Displacement. NEBRASKA-1 likewise.
|
||||
- **Family**: Displacement rather than Thermal displacement. The tilt does not come back at equal housing temperature: tilt ≈ +0.3 at 40.3 °C on the 13th, ≈ −0.6 at 40.6 °C on the 17th, ≈ −2.5 at 40.15 °C on the 19th. metrics.py gives r = +0.51 between tilt and temperature over the range: a weak link, not established.
|
||||
- **Measured** (2 h medians, `work/tilt_2h_11-13.txt`): tilt −2.33 (11th 12h) → +0.61 (13th 00h), in thousandths of a degree. Over the same time, corr_y moves as follows: D-306-B 0.026–0.034 → 0.064; D-304-B −0.071 → −0.053; D-303-B 0.059 → 0.07; D-302-B 0.064 → 0.036 at 13th 00h, then back to about 0.05. Raw y of all sensors, references included, rises together (overview, y panel).
|
||||
- **Images**: 11th 09:00, 13th 12:00: nothing in front.
|
||||
- **Confidence**: medium. The amplitude is small (2–3 noises per measurement, clear on the 2 h medians and the residuals), but the sign pattern is the same as on 17–20 with the opposite direction.
|
||||
|
||||
### 2026-10-17T16:00Z → 2026-10-20T00:30Z (new)
|
||||
- **Phenomenon**: The camera tilts little by little; incomplete compensation.
|
||||
- **Precedents**: BREITHORN-2 and BREITHORN-11 (the compensation corrects some targets better than others), SNCF01-7.
|
||||
- **Family**: Displacement, as above. The temperature drops on the 18th (39.6 °C at 08:00, 39.55 °C at the restart), but the tilt keeps going down until 19th 04:30 while the housing is back at 40.1 °C. A gap does not cut it: the movement is visible on both sides of CLARIDEN-19.
|
||||
- **Measured** (2 h medians, `work/tilt_2h_17-20.txt`): tilt −0.01 (17th 16h) → −1.0 (18th 00h) → −4.6 (19th 04h) → −2.4…−2.9 (19th afternoon) → +1.35 (20th 00h). Over the same time, corr_y moves as follows: D-302-B 0.041 → 0.098 (19th 04h), back to 0.073–0.085; D-303-B 0.062 → 0.026 (19th 08h); D-304-B −0.069 → −0.086; P-301-B −0.009 → −0.033; D-306-B 0.058 → 0.022; D-303-C −0.139 → −0.182; D-304-C −0.487 → −0.540. D-301-C corr_x −0.09 → −0.064. All but D-306-B and D-302-B come back at once at the jump of 00:30. `overview.py --others`: the same shapes remain after removing the median of the others, so they are specific to these targets. Rigid fit: the target |residual| median rises only slightly. Error_value: at its level (the 19th 01:50 instant with 5 sensors is isolated).
|
||||
- **Images**: 19th 04:00 (zone thumbnail): nothing in front. 18th 07:00: work lights at the far end.
|
||||
- **Confidence**: medium-high on the event and its bounds (start ±2 h, a slow onset). The family is uncertain between Displacement and a lagging thermal effect of the camera.
|
||||
|
||||
### 2026-10-18T06:30Z → 2026-10-18T06:50Z (new)
|
||||
- **Phenomenon**: as on the 11th 09:00, in corr_x.
|
||||
- **Family**: Displacement (error_value flat).
|
||||
- **Measured**: group_flips: 7 targets at +3.2…+5.0 noises in corr_x at 06:40 (D-304-A 5.0, D-302_A 4.9, D-303-A 4.3, D-300-A 4.2, D-302-B/PR_BG 3.8, P-298-A 3.2). Rigid fit (base 06:00): tx ≈ 0, with PR-291 dx −0.06, PR-293 −0.03, PR-295 −0.03. The camera pan hits its minimum and the scale its maximum at 06:40 (overview, 16th–20th window). Back at 06:50.
|
||||
- **Images**: no image at 06:40; the 06:00 and 07:00 images exist, and 07:00 shows work lights at the far end.
|
||||
- **Confidence**: medium.
|
||||
|
||||
## 2. What I left without a label
|
||||
|
||||
- One-measurement group flips of 5–7 targets at 3–4 noises (group_flips): 12th 01:00, 13th 21:30, 15th 09:00, 15th 13:30, 17th 03:40, 18th 06:00, 18th 09:50 (just after CLARIDEN-18), 19th 13:00. None reaches 5 noises on any target. They are the ordinary jitter of the pose (the rotation scatters by about ±0.002° from one measurement to the next). The 19th 04:20 instant (8 targets, max 4.1) falls inside the tilt label.
|
||||
- Isolated single-sensor spikes at ≈5 noises (P-299-B corr_x 15th 03:20, D-300-C corr_y 11th 02:00, P-299-A corr_y 15th 05:10, PR-284 corr_x 18th 11:20): on noisy targets (noise 0.01–0.03 px), single points within what each sensor does elsewhere.
|
||||
- The housing temperature dip of the 18th 08:00–10:00 is inside CLARIDEN-18. On its own, it moves only the pose already labeled.
|
||||
|
||||
## 3. The documentation
|
||||
|
||||
- Helpful: `families.md` "The camera tilts little by little" and `reading-rules.md` §5 ("A drift specific to a few targets that follows the camera, on the same dates, is the scene deforming with it"). Also labeling-rules §2 ("bounds are measurement instants", "a plateau is not a return", "a lasting jump is bounded on the jump") and §3 ("A deviation specific to targets, mixed with a camera movement, is the same event if it follows it in both directions").
|
||||
- The precedents BREITHORN-2 and BREITHORN-11 gave the family and the wording.
|
||||
- Reading rule "A jump is judged against the neighbours / the past of the target" was decisive for CLARIDEN-22: most of its jumps are returns.
|
||||
- The validator did not flag the off-cadence bounds (22:45, 13:45, 10:15, 20:45, 00:15, 00:45): perhaps it could check against the station cadence.
|
||||
- Contradicted: CLARIDEN-14 and CLARIDEN-15 said "No camera movement", but the camera tilt does move by a few thousandths of a degree over days. This is small next to "a few hundredths" (DATA.md orders of magnitude), but enough to leave remainders of several noises on some targets. `stations.md` lists four references for CLARIDEN, while PR-296 is a fifth global reference retained at every instant.
|
||||
- The catalogue entry "The camera drifts away when the temperature of its housing drops, without a daily cycle" was tempting. The test "comes back at equal temperature" rejected it here.
|
||||
|
||||
## Difficulties
|
||||
|
||||
- The instructions file changed during the work (the weather moved to `data/<STATION>/weather/`); neither source has CLARIDEN.
|
||||
- The regression part of `scripts/tilt_vs_targets.py` printed nothing: the timestamps of the displacement and camera files differ by seconds. The 2 h tables were enough.
|
||||
|
||||
## Sources read
|
||||
|
||||
`instructions/analyst.md`, `tools/GUIDE.md`, `tools/DATA.md`, `labeling/families.md`, `labeling/labeling-rules.md`, `labeling/reading-rules.md`, `labeling/stations.md`, `labeling/auto/CLARIDEN.jsonl` (labels 10–25 at the edges), `work/existing.jsonl`, `work/spanning.jsonl`, precedents (WILDSTRUBEL-83/102/71/47/55/200, BREITHORN-2/11, SNCF01-7, NEBRASKA-1). Tools: inventory, overview (range; 16th–20th with --others and --rigid; 19th–20th and 18th at 10 min; 11th and 18th with --rigid), summary, plot, metrics, ranges (--rolling 12), thumbnails (zone); my scripts `scripts/tilt_vs_targets.py`, `scripts/group_flips.py`, `scripts/fig_tilt.py`. Images: 18th 08:00 and 09:00 whole; zone thumbnails 11th 09:00, 13th 12:00, 18th 07:00, 19th 04:00, 20th 00:00, 20th 01:00.
|
||||
@@ -0,0 +1,12 @@
|
||||
{"start": "2026-10-11T06:00Z", "end": "2026-10-16T12:00Z", "family": "Displacement", "description": "The targets of row C slowly come back after their drift of the 6th to the 11th: D-301-C goes back down horizontally from the 11th to the 15th, D-304-C and D-303-C go back down vertically from the 12th until the first measurements after the gap of the night of the 15th to the 16th, then stay at that level until the 17th: the return is over. Their later movements are not part of it: the dip of the 18th and 19th follows the slow tilting of the camera and comes back at its jump of the 20th (both labeled separately). These movements do not follow the slow straightening of the camera of the 11th to the 13th (labeled separately) either: they continue while the camera is still. Nothing in front of the targets on the image of the 13th. The housing temperature stays almost constant over these days: no link with it. This is the return of the drift of the 6th to the 11th, labeled separately. Cause not established, in a tunnel under construction: a movement of these targets is not excluded. To be checked against the other measurements of the site; monitor this row."}
|
||||
{"start": "2026-10-11T08:50Z", "end": "2026-10-11T09:10Z", "family": "Displacement", "description": "For one measurement, the corrected vertical curves of many targets drop together, then come back at the next one. D-304-A, D-301-A, D-303-A and D-302_A drop the most; D-301-C, D-302-B and PR_BG (same prism), P-299-B, P-301-B and P-299-A drop less. At that measurement, the whole scene shifts slightly in the image and the camera pose jumps (rotation, tilt), but the reference D-302-C does not follow the other references: the compensation is skewed for one measurement. The recognition error does not move. The image of that instant shows nothing in front of the targets. Cause not established; points to ignore, not a movement of the structure."}
|
||||
{"start": "2026-10-11T14:00Z", "end": "2026-10-13T02:00Z", "family": "Displacement", "description": "From the 11th to the 13th, the camera slowly straightens: its tilt rises, and the raw positions of all sensors, references included, move together vertically in the image. The compensation does not render this movement evenly. The corrected vertical curves of D-306-B, D-304-B and D-303-B rise a little, following the tilt step by step, then stay at their new level, the camera being still from the 13th; those of D-302-B and PR_BG (same prism) go down a little during the movement and come back soon after. These are the same targets as in the tilting of the 17th to the 19th (labeled separately), moving in the opposite direction. The recognition error stays at its level, and the images of the 11th and the 13th show nothing in front of the targets. The housing temperature rises a little over these days, but on other days the tilt is not the same at equal temperature: link not established. This is not a movement of the structure but the remainder of an incomplete compensation of the camera movement; the camera is to be monitored."}
|
||||
{"start": "2026-10-15T22:50Z", "end": "2026-10-16T10:30Z", "family": "No data", "description": "No measurement or image for almost twelve hours, on the night of 15 to 16, and no station metric. The gap starts at the same time, around 23:00, on the nine stations that were measuring then (LENZSPITZE only has its first measurements in the middle of that night, WILDSTRUBEL is already stopped), and their metrics stop at the same time on most of them; measurements and metrics resume at different times depending on the station, most of them in late morning. JUNGFRAU, whose metrics continue, accumulates unsent entries all night, sent in late morning, and yet its measurements for the night are missing from the data: a common cause outside the stations (transmission or reception of the data), not a shutdown of the stations; it is not established. In addition, at CLARIDEN, the station restarts on its battery: the voltage stays well below its usual level, without charge, until early afternoon, then charging resumes; its power supply was also missing that night. The curves are missing over the range; check the site power supply if it repeats."}
|
||||
{"start": "2026-10-16T14:20Z", "end": "2026-10-16T14:40Z", "family": "No data", "description": "One measurement is missing, for all sensors, a few hours after the resumption of the 16th: the curves have a short gap; normal voltage around it. The same gap falls at the same moment on the other stations measuring at that time (FLORIDA, LENZSPITZE, NORDEND, SNCF01): a common cause outside the station (transmission or reception of the data), not a failure of the station; it is not established. The curves are missing over the range; nothing to do on the station.", "review": "2026-11-17"}
|
||||
{"start": "2026-10-17T16:00Z", "end": "2026-10-20T00:30Z", "family": "Displacement", "description": "From the 17th to the 19th, the camera slowly tilts the other way: its tilt goes down, more and more after the restart that follows the outage of the 18th; it partly comes back during the 19th, then suddenly jumps back on the 20th (labeled separately). The raw positions of all sensors, references included, move together vertically in the image with it. The compensation does not render this movement evenly. The corrected vertical curves of D-302-B and PR_BG (same prism) rise. Those of D-303-B, D-304-B, P-301-B, D-306-B, D-303-C and D-304-C go down, and D-301-C rises a little horizontally. They follow the tilt step by step, come back partly with it on the 19th, and return at once at the camera jump of the 20th. The recognition error stays at its level, and the image of the 19th shows nothing in front of the targets. The housing temperature drops a little on the 18th and is low at the restart after the outage; but the tilt keeps going down after the housing has warmed again, and it does not come back at equal temperature: link not established. This is not a movement of the structure but the remainder of an incomplete compensation of the camera movement; the camera is to be monitored."}
|
||||
{"start": "2026-10-18T06:30Z", "end": "2026-10-18T06:50Z", "family": "Displacement", "description": "For one measurement, the corrected horizontal curves of the targets of row A (D-304-A, D-302_A, D-303-A, D-300-A, P-298-A, D-301-A) and of D-302-B and PR_BG (same prism) jump together, then come back at the next one. The raw positions of the targets do not move; the references PR-291, PR-293 and PR-295 shift slightly horizontally against them, and the camera pose jumps (pan, scale): the compensation is skewed for one measurement. The recognition error stays at its level. There is no image at that instant; the image of the next hour shows work lights at the far end of the tunnel and nothing in front of the targets. Cause not established; points to ignore, not a movement of the structure."}
|
||||
{"start": "2026-10-18T08:50Z", "end": "2026-10-18T09:30Z", "family": "Visibility", "description": "For three measurements, the corrected curves of many targets make a bump that comes back: first the targets of row A (D-300-A, D-301-A, D-302_A, D-303-A, D-304-A, P-298-A) rise vertically; over the next two measurements, the recognition error of most targets and of the references PR-293 and PR-295 rises, D-302-B and PR_BG (same prism) rise strongly vertically, D-301-C goes down strongly horizontally, and P-301-B and D-303-B move horizontally. All come back at the following measurement. The camera pose jumps at the same time (tilt, scale), and the housing temperature drops. The image of the first measurement shows nothing in front of the targets. The signature is that of the other view obstruction episodes at the station: the error rises on most sensors, and the edges are sharp. Reduced visibility is deduced from it; the cause is not seen. Points to ignore."}
|
||||
{"start": "2026-10-18T13:50Z", "end": "2026-10-18T23:30Z", "family": "No data", "description": "No measurement or image for almost ten hours, nor station metric. On resumption, the battery is depleted and the voltage low, then they rise: signature of a power cut. The curves are missing over the range; check the power supply if it repeats."}
|
||||
{"start": "2026-10-19T09:00Z", "end": "2026-10-19T10:10Z", "family": "No data", "description": "Four measurements are missing within one hour, for all sensors, between isolated measurements: the curves have gaps; normal voltage around them. The same gap falls at the same moment on the other stations measuring at that time (FLORIDA, JUNGFRAU, LENZSPITZE, NIEDERHORN, NORDEND, SNCF01): a common cause outside the station (transmission or reception of the data), not a failure of the station; it is not established. The curves are missing over the range; nothing to do on the station."}
|
||||
{"start": "2026-10-19T20:40Z", "end": "2026-10-19T21:30Z", "family": "No data", "description": "Three measurements are missing in less than an hour, for all sensors: the curves have a gap; normal voltage around it. The same gap falls at the same moment on the other stations measuring at that time (FLORIDA, JUNGFRAU, LENZSPITZE, NIEDERHORN, NORDEND, SNCF01): a common cause outside the station (transmission or reception of the data), not a failure of the station; it is not established. The curves are missing over the range; nothing to do on the station. The hourly metrics of BREITHORN, MICHIGAN and NEBRASKA are also missing at 21:00."}
|
||||
{"start": "2026-10-20T00:10Z", "end": "2026-10-20T00:40Z", "family": "Displacement", "description": "On the 20th, over two measurements, the whole scene, references included, suddenly shifts in the image, mostly vertically: the camera has moved (its tilt jumps). The compensation absorbs most of it, but the corrected curves of several targets jump. Vertically, D-303-C, D-304-C, D-304-B, D-303-B and P-301-B go back up to the level they had before the slow tilting of the camera of the 17th to the 19th (labeled separately): this jump erases its remainder. D-306-B jumps up clearly, beyond its earlier level, and stays there. D-302-B and PR_BG (same prism) jump horizontally and stay there. The recognition error of D-302-B and D-303-B changes level at the same moment. Work lights are visible at the far end of the tunnel on the images of the hour before and the hour after; nothing is in front of the targets. The cause of the camera movement is not established. The lasting jumps of D-306-B and D-302-B are not an established movement of the structure: to be checked; the camera is to be monitored."}
|
||||
@@ -0,0 +1,65 @@
|
||||
# CLARIDEN: verification of the labels, 11–20 October
|
||||
|
||||
You asked me to verify the 8 existing labels of 11 October 00:00 → 20 October 04:00 (UTC): keep, correct, remove or add.
|
||||
|
||||
## In short
|
||||
|
||||
One label holds as is, seven needed corrections (mostly bounds), and four labels were added. The main miss: the camera slowly tilts on the 11th–13th and the 17th–20th, and the corrected curves of a few targets follow it. Between the 17th and the 20th, do not read the vertical drift of D-302-B, D-303-B, D-304-B, P-301-B, D-306-B, D-303-C and D-304-C as a movement. No real movement of the structure is established; the jumps of D-306-B and D-302-B on the 20th remain to be checked.
|
||||
|
||||
## Verification
|
||||
|
||||
Kept 1, corrected 7, removed 0, added 4.
|
||||
|
||||
- CLARIDEN-15: the end moves from the 20th 00:20 to the 16th 12:00. The return of row C is complete on the 16th; after that the curves are flat. Their dip of the 18th–19th follows the camera tilt (new label). The description no longer says "no camera movement".
|
||||
- CLARIDEN-16: start 22:45 → 22:50, the last measurement before the gap (the station measures every 10 min).
|
||||
- CLARIDEN-18: start 09:00 → 08:50. At 09:00 the row A targets already jump vertically. The description now names them and says that the 09:00 image shows nothing in front.
|
||||
- CLARIDEN-19: start 13:45 → 13:50, the last measurement before the gap.
|
||||
- CLARIDEN-20: end 10:15 → 10:10, the first measurement after the gaps.
|
||||
- CLARIDEN-21: start 20:45 → 20:40, the last measurement before the gap.
|
||||
- CLARIDEN-22: bounds 00:15→00:45 → 00:10→00:40 (measurement instants; the scene starts moving at 00:20). The old description was wrong on most of the jumps. Most of them bring D-303-C, D-304-C, D-304-B, D-303-B and P-301-B back to where they were before the 17th. Only D-306-B (vertically) and D-302-B/PR_BG (horizontally) keep a new level.
|
||||
- Added: the camera straightens slowly, 11th 14:00 → 13th 02:00.
|
||||
- Added: the camera tilts slowly, 17th 16:00 → 20th 00:30.
|
||||
- Added: a one-measurement jump of many targets, 11th 09:00 (vertical).
|
||||
- Added: a one-measurement jump of many targets, 18th 06:40 (horizontal).
|
||||
- Spanning CLARIDEN-1 (P-300-B always rejected): correct in the range.
|
||||
- Spanning CLARIDEN-14: correct in the range (11th 00:00–06:00). Just before the range, though, its "no camera movement" is contradicted: the camera tilts from the 9th to the 11th, and D-306-B follows it.
|
||||
|
||||
## What happened
|
||||
|
||||
**The camera tilts slowly, and the compensation does not follow evenly.** From the 11th to the 13th the camera straightens a little. From the 17th to the 19th it tilts the other way, more strongly after the power cut of the 18th, then partly comes back on the 19th. All raw positions, references included, move together. A few targets do not get the same correction as the others. Vertically, D-302-B rises while D-303-B, D-304-B, P-301-B, D-306-B, D-303-C and D-304-C go down, by a few hundredths of a pixel, following the tilt step by step. They come back at once when the camera jumps back on the 20th. The housing temperature varies little, and the tilt does not come back at equal temperature, so a thermal link is not established. Cause: likely an incomplete compensation of a camera movement, as at BREITHORN.
|
||||
|
||||

|
||||
|
||||
Top: the camera tilt; bottom: the vertical curves of five targets. In the grey zones they move with the tilt, and they jump back with it on the 20th.
|
||||
|
||||
**The camera jumps on the 20th, shortly after midnight.** The whole scene shifts in two measurements. Most targets come back to their normal level (see above). D-306-B jumps up beyond its usual level and stays there; D-302-B/PR_BG jump sideways and stay there. Work lights are visible at the far end of the tunnel on the images around it. The cause is unknown.
|
||||
|
||||
**Short disturbances.** On the 18th 08:50–09:30, a three-measurement bump on many targets comes with a rise of the recognition error on most sensors: likely reduced visibility, not seen on the image. On the 11th 09:00 and the 18th 06:40, many targets jump together for a single measurement. The references move slightly against each other, which skews the correction. The cause is unknown; these points are to be ignored.
|
||||
|
||||
**Gaps.** Four gaps: the night of the 15th–16th, a short one on the 16th, and two on the 19th. They are common to several stations. A power cut on the 18th from 13:50 to 23:30. All as already labeled; only the bounds were set on the measurement instants.
|
||||
|
||||
## What to do
|
||||
|
||||
Check the camera mount and its fixing, since its tilt wanders by small amounts over days and jumped on the 20th. Compare D-306-B and D-302-B after the 20th with the other measurements of the site.
|
||||
|
||||
## Not established
|
||||
|
||||
- The cause of the slow tilt: a thermal effect with a delay is possible, but the temperature does not explain it at equal value. Watching the tilt against the housing temperature over more weeks would settle it.
|
||||
- The cause of the jump of the 20th, and whether the new level of D-306-B and D-302-B is real. Tunnel work at that time is the hypothesis to check with the site.
|
||||
|
||||
## Labels
|
||||
|
||||
| Start (UTC) | End (UTC) | Family | Targets | In a few words |
|
||||
|---|---|---|---|---|
|
||||
| 2026-10-11 06:00 | 2026-10-16 12:00 | Displacement | D-301-C, D-303-C, D-304-C | slow return of row C, ends on the 16th (corrected) |
|
||||
| 2026-10-11 08:50 | 2026-10-11 09:10 | Displacement | row A, D-301-C, D-302-B/PR_BG, P-299-B… | one measurement, compensation skewed (added) |
|
||||
| 2026-10-11 14:00 | 2026-10-13 02:00 | Displacement | D-306-B, D-304-B, D-303-B, D-302-B/PR_BG | camera straightens slowly, remainder on a few targets (added) |
|
||||
| 2026-10-15 22:50 | 2026-10-16 10:30 | No data | all | night gap, common to the stations (bounds corrected) |
|
||||
| 2026-10-16 14:20 | 2026-10-16 14:40 | No data | all | one missing measurement (kept) |
|
||||
| 2026-10-17 16:00 | 2026-10-20 00:30 | Displacement | D-302-B/PR_BG, D-303-B, D-304-B, P-301-B, D-306-B, D-303-C, D-304-C | camera tilts slowly, remainder on a few targets (added) |
|
||||
| 2026-10-18 06:30 | 2026-10-18 06:50 | Displacement | row A, D-302-B/PR_BG | one measurement, compensation skewed (added) |
|
||||
| 2026-10-18 08:50 | 2026-10-18 09:30 | Visibility | row A, D-302-B/PR_BG, D-301-C, P-301-B, D-303-B | short bump with recognition error up (corrected) |
|
||||
| 2026-10-18 13:50 | 2026-10-18 23:30 | No data | all | power cut (bounds corrected) |
|
||||
| 2026-10-19 09:00 | 2026-10-19 10:10 | No data | all | common gaps (bounds corrected) |
|
||||
| 2026-10-19 20:40 | 2026-10-19 21:30 | No data | all | common gaps (bounds corrected) |
|
||||
| 2026-10-20 00:10 | 2026-10-20 00:40 | Displacement | D-306-B, D-302-B/PR_BG, D-303-C, D-304-C, D-304-B, D-303-B, P-301-B | camera jump; most targets come back, D-306-B and D-302-B keep a jump (corrected) |
|
||||
@@ -0,0 +1,6 @@
|
||||
{
|
||||
"station": "CLARIDEN",
|
||||
"start": "2026-10-11T00:00Z",
|
||||
"end": "2026-10-20T04:00Z",
|
||||
"hints": "Verify the existing labels of the range (work/existing.jsonl): keep, correct, remove, add."
|
||||
}
|
||||
@@ -0,0 +1,19 @@
|
||||
"""Figure: camera tilt and corr_y of the targets that follow it, 2h medians, from tilt_vs_targets.py output."""
|
||||
import sys, matplotlib; matplotlib.use('Agg'); import matplotlib.pyplot as plt
|
||||
from datetime import datetime
|
||||
rows=[l.split() for l in open(sys.argv[1]) if l[:2]=='10' and '-' in l[:6]]
|
||||
t=[datetime.strptime('2026-'+r[0],'%Y-%m-%dT%H:%M') for r in rows]
|
||||
def col(i): return [float(r[i]) if r[i] != '-' else float('nan') for r in rows]
|
||||
fig,ax=plt.subplots(2,1,figsize=(11,6),sharex=True)
|
||||
ax[0].plot(t,col(1),'k.-'); ax[0].set_ylabel('camera tilt\n(thousandths of a degree)')
|
||||
names=['D-302-B','D-303-B','D-304-B','P-301-B','D-306-B']
|
||||
for j,n in enumerate(names):
|
||||
v=col(3+j); m=sorted(x for x in v if x==x)[len(v)//2]
|
||||
ax[1].plot(t,[x-m for x in v],'.-',label=n)
|
||||
ax[1].set_ylabel('corrected vertical curve\nminus its median (px)'); ax[1].legend(ncol=5,fontsize=8)
|
||||
for a in ax:
|
||||
for s,e in [('2026-10-11T14:00','2026-10-13T02:00'),('2026-10-17T16:00','2026-10-20T00:30')]:
|
||||
a.axvspan(datetime.fromisoformat(s),datetime.fromisoformat(e),color='0.9')
|
||||
a.grid(alpha=.3)
|
||||
fig.suptitle('CLARIDEN: the camera tilt and the targets that follow it (2 h medians, UTC)')
|
||||
fig.tight_layout(); fig.savefig(sys.argv[2],dpi=90); print(sys.argv[2])
|
||||
@@ -0,0 +1,40 @@
|
||||
"""Instants where many targets deviate together, same sign, from their rolling local level.
|
||||
For each target and column (corr_x, corr_y), deviation = value - median of the +-N neighbouring
|
||||
accepted measurements (itself excluded), in units of the target's own noise (median |step|).
|
||||
Prints the instants where at least K targets exceed THR noises with the same sign.
|
||||
Usage: python3 group_flips.py START END [N=6] [THR=3] [K=6]"""
|
||||
import csv, glob, sys, statistics as st
|
||||
from datetime import datetime, timedelta
|
||||
|
||||
S = datetime.fromisoformat(sys.argv[1].replace('Z', '+00:00'))
|
||||
E = datetime.fromisoformat(sys.argv[2].replace('Z', '+00:00'))
|
||||
N = int(sys.argv[3]) if len(sys.argv) > 3 else 6
|
||||
THR = float(sys.argv[4]) if len(sys.argv) > 4 else 3
|
||||
K = int(sys.argv[5]) if len(sys.argv) > 5 else 6
|
||||
REFS = {'D-302-C', 'PR-291', 'PR-293', 'PR-295', 'PR-296'}
|
||||
data = {}
|
||||
d = S.date() - timedelta(days=1)
|
||||
while d <= E.date():
|
||||
for f in glob.glob(f'data/CLARIDEN/displacement/CLARIDEN_advanced_{d:%Y%m%d}.csv'):
|
||||
for r in csv.DictReader(open(f)):
|
||||
t = r['time_utc'][:16].replace(' ', 'T') + 'Z'
|
||||
tt = datetime.fromisoformat(t.replace('Z', '+00:00'))
|
||||
if not (S <= tt <= E) or r['sensor_name'] in REFS or r['corr_x'] == '':
|
||||
continue
|
||||
data.setdefault(r['sensor_name'], {})[t] = (float(r['corr_x']), float(r['corr_y']))
|
||||
d += timedelta(days=1)
|
||||
dev = {}
|
||||
for s, series in data.items():
|
||||
ts = sorted(series)
|
||||
for i, col in enumerate(('x', 'y')):
|
||||
v = [series[t][i] for t in ts]
|
||||
noise = st.median(abs(v[j + 1] - v[j]) for j in range(len(v) - 1)) or 1e-9
|
||||
for j, t in enumerate(ts):
|
||||
nb = v[max(0, j - N):j] + v[j + 1:j + 1 + N]
|
||||
dev.setdefault(t, []).append((s, col, (v[j] - st.median(nb)) / noise))
|
||||
for t in sorted(dev):
|
||||
for col in ('x', 'y'):
|
||||
for sign in (1, -1):
|
||||
hit = [(s, round(z, 1)) for s, c, z in dev[t] if c == col and z * sign > THR]
|
||||
if len(hit) >= K:
|
||||
print(t, f'corr_{col}', '+' if sign > 0 else '-', len(hit), ' '.join(f'{s}:{z}' for s, z in sorted(hit, key=lambda h: -abs(h[1]))))
|
||||
@@ -0,0 +1,77 @@
|
||||
"""Per-step medians of camera tilt, housing temperature and corr_y/corr_x of chosen targets; and
|
||||
the regression of each target's corr on the tilt over chosen windows.
|
||||
Usage: python3 tilt_vs_targets.py START END STEP_HOURS"""
|
||||
import csv, glob, sys, statistics as st
|
||||
from datetime import datetime, timedelta, timezone
|
||||
|
||||
S = datetime.fromisoformat(sys.argv[1].replace('Z', '+00:00'))
|
||||
E = datetime.fromisoformat(sys.argv[2].replace('Z', '+00:00'))
|
||||
H = float(sys.argv[3])
|
||||
T = ['D-302-B', 'D-303-B', 'D-304-B', 'P-301-B', 'D-306-B', 'D-303-C', 'D-304-C', 'D-301-C']
|
||||
base = 'data/CLARIDEN'
|
||||
|
||||
def t(s):
|
||||
return datetime.fromisoformat(s.split('.')[0].replace(' ', 'T')[:19] + '+00:00')
|
||||
|
||||
def days():
|
||||
d = S.date() - timedelta(days=1)
|
||||
while d <= E.date():
|
||||
yield d
|
||||
d += timedelta(days=1)
|
||||
|
||||
corr = {} # (sensor, col) -> list of (time, value)
|
||||
for d in days():
|
||||
for f in glob.glob(f'{base}/displacement/CLARIDEN_advanced_{d:%Y%m%d}.csv'):
|
||||
for r in csv.DictReader(open(f)):
|
||||
tt = t(r['time_utc'])
|
||||
if not (S <= tt <= E) or r['sensor_name'] not in T or r['corr_y'] == '':
|
||||
continue
|
||||
for c in ('corr_x', 'corr_y'):
|
||||
corr.setdefault((r['sensor_name'], c), []).append((tt, float(r[c])))
|
||||
tilt = []
|
||||
for d in days():
|
||||
for f in glob.glob(f'{base}/camera/CLARIDEN_camera_{d:%Y%m%d}.csv'):
|
||||
for r in csv.DictReader(open(f)):
|
||||
tt = t(r['time_utc'])
|
||||
if S <= tt <= E:
|
||||
tilt.append((tt, float(r['median_tilt'])))
|
||||
temp = []
|
||||
for d in days():
|
||||
for f in glob.glob(f'{base}/metrics/CLARIDEN_sensor_GPU_deg_c_{d:%Y_%m_%d}_*.csv'):
|
||||
for r in csv.DictReader(open(f)):
|
||||
tt = t(r['time_utc'])
|
||||
if S <= tt <= E and r['metric'] != '':
|
||||
temp.append((tt, float(r['metric'])))
|
||||
|
||||
def binned(series):
|
||||
out = {}
|
||||
for tt, v in series:
|
||||
k = int((tt - S).total_seconds() // (H * 3600))
|
||||
out.setdefault(k, []).append(v)
|
||||
return {k: st.median(v) for k, v in out.items()}
|
||||
|
||||
bt, bT = binned(tilt), binned(temp)
|
||||
bc = {k: binned(v) for k, v in corr.items()}
|
||||
keys = sorted(bt)
|
||||
print('step_start tilt*1e3 temp ' + ' '.join(f'{s[:7]:>8}y' for s in T) + ' D-302-Bx D-301-Cx')
|
||||
for k in keys:
|
||||
row = [f'{(S + timedelta(hours=k * H)):%m-%dT%H:%M}', f'{bt[k]*1e3:8.2f}', f'{bT.get(k, float("nan")):5.2f}']
|
||||
for s in T:
|
||||
v = bc.get((s, 'corr_y'), {}).get(k)
|
||||
row.append(f'{v:9.3f}' if v is not None else ' -')
|
||||
for s in ('D-302-B', 'D-301-C'):
|
||||
v = bc.get((s, 'corr_x'), {}).get(k)
|
||||
row.append(f'{v:8.3f}' if v is not None else ' -')
|
||||
print(' '.join(row))
|
||||
|
||||
# regression of each target's corr_y on tilt, per measurement
|
||||
tl = dict(tilt)
|
||||
print('\nregression of corr_y on tilt (per measurement): slope px per 1e-3 deg, r')
|
||||
for s in T:
|
||||
pts = [(tl[tt], v) for tt, v in corr.get((s, 'corr_y'), []) if tt in tl]
|
||||
if len(pts) < 10:
|
||||
continue
|
||||
xs, ys = zip(*pts)
|
||||
mx, my = st.mean(xs), st.mean(ys)
|
||||
sxy = sum((a - mx) * (b - my) for a, b in pts); sxx = sum((a - mx) ** 2 for a in xs); syy = sum((b - my) ** 2 for b in ys)
|
||||
print(f'{s:8} slope {sxy / sxx * 1e-3:+.4f} r {sxy / (sxx * syy) ** 0.5:+.2f} n {len(pts)}')
|
||||
Binary file not shown.
|
After Width: | Height: | Size: 127 KiB |
Reference in new issue