auto: the analysts verified the labels of 32 periods (11 stations, up to 14 days each): 710 labels -> 835, 587 unchanged; one analysis folder per period with its report (section Verification)

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
maximeandClaude Opus 5.5 committed 2026-11-17 15:13:44 +01:00
1 parent df979301b5
commit 2a5d87659b
279 files changed
+10758 -710

No files matched your search

@@ -0,0 +1,118 @@
# Labels: NORDEND, 2026-08-10T01:15Z → 2026-08-23T05:15Z (UTC)
This is a verification of the 49 existing labels (`work/existing.jsonl`, all reviewed by the user on 2026-11-17), plus the spanning NORDEND-24. Verdicts: **47 kept, 2 corrected (NORDEND-40, NORDEND-49), 0 removed, 0 added.** `labels.jsonl` holds the 49 labels: the kept ones exactly as they were (review field included, id removed), the two corrected ones without their review field.
Weather: `stations.txt` gives NORDEND → "Ouffet". `meteoswiss.py` resolved this to L'Ouffette (VS), station MAR Les Marécottes, 4.9 km. NORDEND is a quarry, and the place name may well be Ouffet in Belgium, so this weather is probably not the station's. It was not used as evidence; the images were.
## 0. Verdict per old id
| id | verdict | evidence |
|---|---|---|
| NORDEND-1 | kept | PR12 corr_x at 15 min: level about 0.06–0.08 until 01:15, dips from 01:30 (0.031) to 02:15 (0.017; lowest 0.005 at 02:00), back at 02:30 (0.051). The fast-deviation scan flags only PR12 x at 02:00 and 02:15. The bounds hold. |
| NORDEND-2 | kept | CTR01 rejected at 10/08 05:45 only (inventory). Image 05:45: sun in the field, scene dark. |
| NORDEND-3 | kept | Pose turning point 05:30 (tilt −117 → −115 → −105 m°, pan +9 → +6 → +4). Sun facing the camera on the 05:45 image. The chain to NORDEND-5 is at the next turning point. |
| NORDEND-4 | kept | CTR01 rejected 13:45 → 16:45 (13 measurements); label runs 13:30 → 17:00. |
| NORDEND-5 | kept | Turning point 05:45 (tilt −120 → −116, pan +13 → +12). Sun on the 06:30 image. |
| NORDEND-6 | kept | CTR01 rejected 11/08 06:30 only. Sun on the 06:30 image. |
| NORDEND-7 | kept | CTR01 rejected 13:00, then 13:45 → 16:45; label runs 12:45 → 17:00. |
| NORDEND-8 | kept | CTR01 rejected 12/08 06:00. Sun on the 06:00 image. |
| NORDEND-9 | kept | Turning point 05:45 (tilt −120 → −117 → −71). |
| NORDEND-10 | kept | CTR01 rejected 13:45 → 16:45. 14:30 image: sunlit rock face. |
| NORDEND-11 | kept | CTR01 rejected 13/08 06:00. Sun on the 06:00 image. |
| NORDEND-12 | kept | Turning point 05:45. Strongest pose day: pan lowest −0.050 on 13/08 15:00; housing temperature 58 °C, the highest of the batch. |
| NORDEND-13 | kept | CTR01 rejected 13:45 → 16:45. |
| NORDEND-14 | kept | CTR01 rejected 06:00 → 06:15; label runs 05:45 → 06:30. Sun on the 06:00 image. |
| NORDEND-15 | kept | Turning point 05:45. Ends at the next turning point, 15/08 05:15. |
| NORDEND-16 | kept | CTR01 rejected 13:45 → 16:45. |
| NORDEND-17 | kept | One step missing at 15/08 01:15. Images every 15 min over 13 → 19/08, so the image of that instant exists. |
| NORDEND-18 | kept | Turning point 15/08 05:15 (tilt −116 → −113 → −101). Cloudy jolts: the scan flags PR14, PR01, PR10 at 6–7 noises at 09:30, which the description covers. |
| NORDEND-19 | kept | CTR01 rejected 13:15, 13:45–14:00, 14:30–16:00, 16:45; label runs 13:00 → 17:00. 16/08 14:00 image: sunlit rock. |
| NORDEND-20 | kept | Overcast morning; slow turning point about 06:30 (tilt −111/−113/−110/−108). This is within a step of the uncertainty. |
| NORDEND-21 | kept | CTR01 rejected 16/08 09:30 only. |
| NORDEND-22 | kept | CTR01 rejected 13:15, 14:00–14:15, 14:45, 16:30–16:45; label runs 13:00 → 17:00. 14:00 image: sunlit rock. |
| NORDEND-23 | kept | PR07 rejected from 02:45, CTR01 05:00 → 10:15, PR09 05:00 → 08:45; label runs 02:30 → 10:30. The fast-deviation scan flags PR05, PR06, PR08, PR14, PR15, PR16 between 05:45 and 06:45, all inside the label. |
| NORDEND-25 | kept | Turning point 17/08 07:30 (tilt −119 → −107 at 07:45, pan +9 → +6). |
| NORDEND-26 | kept | CTR01 rejected 13:45, 14:15, 14:45 → 15:15; label runs 13:30 → 15:30. |
| NORDEND-27 | kept | Fast deviation on PR16 x at 06:30, so the 06:15 start holds. Rejections run to 12:00 (CTR01); end 12:15. 07:45 image: uneven light, no obstacle. |
| NORDEND-28 | kept | Turning point 08:15 (tilt −119 → −115 at 08:30). The night with CTR03 lost is correctly referred to its own label. |
| NORDEND-29 | kept | CTR01 rejected 15:30; PR07, PR09, PR11 15:45 → 16:15; fast deviation PR16 x at 16:30. Bounds 15:15 → 16:45 hold. |
| NORDEND-30 | kept | CTR01 rejections 17:45 → 03:45; label runs 17:30 → 04:00. 18/08 23:00 image: lit web. |
| NORDEND-31 | kept | CTR02 rejected 18:00 only, with 0 references retained at that instant. 15 sensors deviate together at 18:00 (scan). |
| NORDEND-32 | kept | CTR03 rejected 22:30 → 01:00 (11 measurements). Plateau of CTR02 y, CTR04 x, PR17, PR18 from 22:30 to 01:00, rebound at 01:15; 01:30 missing, so the end at 01:45 holds. |
| NORDEND-33 | kept | 01:30 missing; image gap 01:15 → 01:45 (inventory). |
| NORDEND-34 | kept | CTR01 rejected 07:00–07:15, 09:00, 10:30, 12:00; label runs 06:45 → 12:15. |
| NORDEND-35 | kept | Turning point 07:15 (tilt −115 → −109 at 07:30). Ends before the gap at 20/08 03:45, as the gap rule says. |
| NORDEND-36 | kept | 23 steps missing 14:30 → 20:00. Images missing over 14:15 → 20:15. No metric 15:00 → 19:00, voltage normal before and after. The claim about FLORIDA, MISSISSIPPI and VERMONT cannot be checked: no other station has August data. |
| NORDEND-37 | kept | CTR01 rejected 20:15–20:30 and 21:00 → 03:45; PR07 rejected 23:00 → 23:30. PR08 corr_x is low (0.004 to 0.04 against about 0.06 the day before) all night, most in the second half. "Departs in the second half" is a little narrow, but not wrong. |
| NORDEND-38 | kept | 20:45 missing; image gap 20:30 → 21:00. |
| NORDEND-39 | kept | 00:45 missing; image gap 00:30 → 01:00. |
| NORDEND-40 | **corrected** (description) | 9 steps missing, 04:00 → 06:00. But `20260820T0600Z_9852824.jpg` exists, and last_sync has a sync at 06:00:17, while the first measurement is at 06:15. The old text said "image and synchronisation come back with the first measurement": that is false by one step. The bounds stay. |
| NORDEND-41 | kept | Measurements resume at 06:15 with the pose already moved (tilt −91 m° against −120 the night before). PR18 corr_x rises all night (0.23 → 0.27). |
| NORDEND-42 | kept | 08:15, 08:30, 08:45 missing; image gap 08:00 → 09:00; only one sync in the 08:00 hour; voltage normal. |
| NORDEND-43 | kept | CTR01 rejected 20/08 14:30 only. |
| NORDEND-44 | kept | PR07 rejected 16:30. PR14, PR15, PR16 corr_x at 0.21 against 0.12 at 16:30, still high at 16:45 and 17:00 (0.14–0.16), back at 17:15. PR13 x at 16:00 is −4 to −6 noises on a single point; not enough to move the start. |
| NORDEND-45 | kept | 00:45 and 01:00 missing; image gap 00:30 → 01:15. |
| NORDEND-46 | kept | Turning point 05:15: pan leaves at 05:15, tilt at 05:00, the later of the two kept. |
| NORDEND-47 | kept | CTR01 rejected 12:30 and 13:15. |
| NORDEND-48 | kept | PR07 rejected from 16:00, CTR01 17:45 → 07:15, most targets 18:00–19:45. PR08 corr_x is at −0.07 at 20:00, about 0 overnight, 0.039 at 07:00 and back at 07:30 (0.044 against a day level of 0.045). |
| NORDEND-49 | **corrected** (description) | Bounds and family hold: turning point 06:00, then the next label at 23/08 05:15. But the cold-night part named PR10 alone. Most targets' corr_y rise from about 22:30, with a step at 00:00, and stay up until 05:30 (see §1). |
| NORDEND-50 | kept | 16:45 missing; image 16:45 exists. No metric 16:00 → 20:00, then DB_not_uploaded climbs from 86 to 229 until 23/08 07:00. |
| NORDEND-24 (spanning) | holds within the range | PR04: no rejection before 17/08 05:30 in the range; rejections on 17, 18, 20, 21 and 22/08, many on 21–22/08. corr_y is noisy and changes level from 17/08. Its start at 05:15 holds. |
## 1. My labels
### 2026-08-20T03:45Z → 2026-08-20T06:15Z (NORDEND-40, corrected)
- **Phenomenon of the catalogue**: The station runs, the measurement is missing (at its last step). It sits at the end of a longer silence whose cause is not established.
- **Precedents**: the other No data labels of the batch (NORDEND-17, 33, 42), written in the same style.
- **Family**: No data. All curves are missing; there are no rejections.
- **Measured**: inventory: 9 instants missing between 03:45 and 06:15. Images: one gap of 135 min, 03:45 → 06:00, then an image every 15 min from 06:00. last_sync: syncs every 15 min until 03:45:16, then one at 06:00:17. No metric in the 04:00 and 05:00 hours. BusVoltage is 14.06 V at 03:00 and 14.30 V at 06:00.
- **Images**: file list checked; `20260820T0600Z_9852824.jpg` exists.
- **Confidence**: high.
### 2026-08-22T06:00Z → 2026-08-23T05:15Z (NORDEND-49, corrected)
- **Phenomenon of the catalogue**: The camera moves through a thermal effect; for the night, the cold-night variant, as in its own next label NORDEND-51.
- **Precedents**: NEBRASKA-10 and NEBRASKA-11 (reviewed): the coldest night, the camera turns, the corr_y of most targets jump, and the references move slightly relative to each other; labelled Thermal displacement. MICHIGAN-15 (reviewed): the same, with one reference moving slightly away from the overall movement. These supported keeping the family. NORDEND-51 (outside the range, reviewed) says the next night is "like the previous one".
- **Family**: Thermal displacement. Why not Visibility: the error_value of the targets stays at or below its evening level (2 h medians); the spots of CTR02, CTR03 and CTR04 are sharp on the fixed thumbnails at 22/08 20:00, 23/08 00:00 and 03:00; the shift is smooth and follows the temperature, without sharp edges; and the curves come back with the morning warming. Why not Displacement: it comes back with the temperature.
- **Measured**:
- Housing temperature falls from 31.3 °C (21:00) to 26.1 °C (05:00), the lowest of the batch.
- Pose: scale 0.99903 at 04:00 (lowest of the batch), tilt −0.132 (lowest), pan +0.022 (highest); cam_sigma0 up to 0.00207 at 03:00 (highest of the batch).
- `overview.py --rigid 2026-08-22T21:00Z`: target residual median about 0.01 px, unchanged, so the targets do not move relative to each other. CTR04 dy slides to −0.04/−0.05 px from 00:00 (−0.0503 at 01:45). CTR02 dy rises to +0.02 (+0.0248 at 05:00). reproj_err of CTR02 and CTR03 rises from 0.09 to 0.12.
- corr_y, 30 min medians, 21:00 → 02:00: PR15 0.017 → 0.051; PR14 0.019 → 0.055; PR07 0.091 → 0.123; PR10 0.124 → 0.147; PR06 0.082 → 0.104; CTR02 0.092 → 0.117. These are about 4 to 6.6 noises.
- Back at 06:30–07:30 on 23/08 as the housing warms up (PR15 0.0007, PR14 0.0076 at 07:30).
- No fast deviation in the scan (rolling ±4, 6 noises) during the night.
- **Images**: 22/08 20:00 and 23/08 03:00 whole images: lit cobweb threads cross the image and the area of the targets. Reference thumbnails as above.
- **Confidence**: medium. The family and the bounds are sure. That the web plays no part in CTR04's slide rests on its sharp spot and its steady error_value.
## 2. What I left without a label
- **Night 20→21/08 (under NORDEND-41)**: lit web threads cross the targets (23:00 image), but no target except PR04 is rejected, and PR04 is under NORDEND-24. The corr stay within noise, except PR09 corr_y at +5.3 noises for 04:30–04:45 against its level outside the night. That is two points at the threshold; PR09 is noisy (noise 0.0088) and there is no fast deviation at 6 noises. Not labelled. NORDEND-41 does not mention the web, which is correct, since the web touches nothing.
- **Single-sensor fast deviations of 6 to 8 noises outside non-thermal labels**:
- 10/08 06:00 (PR16–18): the sunrise jump, covered by NORDEND-3.
- 11/08 11:15 PR09, 12/08 08:15 PR17, 14/08 08:30 PR10, 15/08 06:15 PR18, 15/08 09:30–09:45 (cloudy jolts, NORDEND-18), 19/08 05:15 PR12, 21/08 09:15–09:45 PR15/PR18, 21/08 14:30 CTR02, 22/08 16:15 CTR02: one point, one sensor each, inside the daily thermal agitation.
- PR04 on 18/08 14:30 and 20/08 11:00 and 13:00: covered by NORDEND-24.
- **PR13 corr_x at 20/08 16:00**: one point just before NORDEND-44, at −4 to −6 noises; it does not move the start.
- **12/08 23:00**: a bright blob at the top of the image, probably an insect; no effect on corr.
## 3. The documentation
- **Helpful**:
- `labeling-rules.md` §2 for the turning-point starts, the bounds at gap edges and "a measurement come back halfway is still touched".
- `families.md` boundary "Thermal displacement or Visibility". It cut both ways on 22→23/08, because references do move apart from each other there. The reviewed NEBRASKA and MICHIGAN precedents decided it, together with the steady error_value and the sharp references.
- `reading-rules.md` §5 ("a very stable error_value says the targets stay well visible").
- **Missing**:
- The catalogue's "A spider web in front of the lens" says "no signal at all is possible". It does not say what to do when the web is seen but the curves are untouched. The rule "only what touches corr" answers it: no label. I applied that to 20→21 and 22→23/08.
- `stations.txt` "Ouffet" geocodes to the Valais. The weather of NORDEND is probably not available this way; this should be checked by whoever owns `stations.txt`.
- **Not verifiable**: NORDEND-36 and NORDEND-50 cite "the data documentation" for gaps at FLORIDA, MISSISSIPPI and VERMONT. Nothing in my sources says so, and no other station has August data. I kept them (reviewed); this phrase is the only unverified part.
- No precedent was contradicted by the data.
## Difficulties
- `meteoswiss.py` refuses times with a trailing `Z`; it was run with `2026-08-10T00:00`.
- `metrics.py` needs `.venv/bin/python` (matplotlib), not `python3`.
## Sources read
- `instructions/analyst.md`, `tools/GUIDE.md`, `tools/DATA.md`, `labeling/families.md`, `labeling/labeling-rules.md`, `labeling/reading-rules.md`, `labeling/stations.md`.
- `work/existing.jsonl`, `work/spanning.jsonl`, `labeling/auto/NORDEND.jsonl` (labels at the edges: NORDEND-51 to 53).
- Precedents: `precedents.py` on the cold-night signature (MICHIGAN-2, MICHIGAN-15, NEBRASKA-10, NEBRASKA-11, WYOMING-7, NORDEND-173).
- Data, through `tools/scripts/data.py` and the tools:
- `inventory.py`; `overview.py` (whole range, then `--rigid` on 22/08 12:00 → 23/08 05:15); `ranges.py` (`--rolling 4 --instants 3`; `--outside` on night 20→21); `summary.py` (corr_x, corr_y, error_value on the nights and windows cited); `metrics.py` (10 → 23/08, then around the gaps); `thumbnails.py` (references and PR15, `--fixed`).
- Whole images: 22/08 20:00, 23/08 03:00; sheets of the 23:00 images of every night and of sunrise and afternoon images (`work/nights23.png`, `work/sunrise.png`).
- Weather: `work/weather.csv` (MAR Les Marécottes, 4.9 km, see above).
- My scripts: `scripts/fast.py` (fast deviations against coverage by the labels), `scripts/morning.py` (morning pose table), `scripts/sheet.py` (contact sheets), `scripts/write_labels.py`.
@@ -0,0 +1,49 @@
{"start": "2026-08-10T01:15Z", "end": "2026-08-10T02:30Z", "family": "Obstruction", "description": "At night, PR12 alone departs on corr_x for about an hour, then comes back; its corr_y and the other targets do not move. On the images from 01:30 to 02:30, blurred shapes lit by the infrared, changing from one image to the next, pass very close to the lens, including a band crossing the target area at 02:00: an animal in front of the camera, spider or insect (its nature is not established). At the same time, the error_value of almost all the sensors rises a little, without any rejection, and the camera pose moves slightly, well compensated. The structure does not move: ignore PR12's curve over the range, nothing to do.", "review": "2026-11-17"}
{"start": "2026-08-10T05:30Z", "end": "2026-08-10T06:00Z", "family": "Visibility", "description": "A CTR01 point (local reference, treated as a target) is missing at sunrise: its measurement is rejected for one acquisition (error_value just above the threshold), then comes back. The rising sun is in the camera's field, with reflections, and the scene is very dark (seen on the 05:45 image). Probable cause: dazzle from the rising sun. The other targets remain measured. Point to ignore, nothing to do.", "review": "2026-11-17"}
{"start": "2026-08-10T05:30Z", "end": "2026-08-11T05:45Z", "family": "Thermal displacement", "description": "Thermal displacement of the camera, poorly compensated. At sunrise, the sun enters the camera's field, facing it (seen on the 05:45 image). The camera heats up all at once (housing temperature sharply up at the same moment): its pose jumps (tilt, pan, scale) and the raw positions of all the targets and references move together, then drift throughout the day. The corrected curves are not flattened: corr_x of PR14 to PR18 drops at once then slowly rises back, especially PR18 and PR16; corr_y of PR18 rises; in the morning, those of PR02, PR03, PR05, PR12 and of the references CTR02, CTR03, CTR04 also depart; in the afternoon, those of PR01 and PR11 rise. Most curves come back in early afternoon, PR16 and PR18 only in the night. The return continues slowly in the evening and all night: the pan and the corr_x of PR18 and PR16 still rise back until the jump of the next morning. No reference lost, ordinary error_value (the rejections of CTR01 are labelled separately). Deduced cause: the pose and the housing temperature follow the sun, and the rock face cannot move with the temperature. Nothing to do, this is not a movement of the structure.", "review": "2026-11-17"}
{"start": "2026-08-10T13:30Z", "end": "2026-08-10T17:00Z", "family": "Visibility", "description": "CTR01 (local reference, treated as a target) is rejected without interruption in the afternoon: its corr_x and corr_y curves are missing. Its error_value rises from late morning, crosses the threshold, then drops all at once to its night level when the wall goes back into shadow. Same hour and same signature as 12/08, where the thumbnails show the sun on the rock around the target. The other targets remain measured and their curves show nothing of their own. The structure does not move: nothing to do, CTR01's curve is missing every sunny afternoon.", "review": "2026-11-17"}
{"start": "2026-08-11T05:45Z", "end": "2026-08-12T05:45Z", "family": "Thermal displacement", "description": "Thermal displacement of the camera, poorly compensated. At sunrise, the sun is in the camera's field, facing it (seen on the 06:30 image). The camera heats up all at once (housing temperature sharply up at the same moment): its pose jumps (tilt, pan, scale) and the raw positions of all the targets and references move together, then drift throughout the day. The corrected curves are not flattened: corr_x of PR14 to PR18 drops at once then slowly rises back, especially PR18 and PR16; corr_y of PR18 rises; in the morning, those of PR03, PR05, PR06, PR13 and of the references CTR02, CTR04 also depart; in the afternoon, those of PR01 and PR11 rise. Most curves come back in early afternoon, PR16 and PR18 in the night. The return continues slowly in the evening and all night: the pan and the corr_x of PR18 and PR16 still rise back until the jump of the next morning. No reference lost, ordinary error_value (the rejections of CTR01 are labelled separately). Deduced cause: the pose and the housing temperature follow the sun, and the rock face cannot move with the temperature. Nothing to do, this is not a movement of the structure.", "review": "2026-11-17"}
{"start": "2026-08-11T06:15Z", "end": "2026-08-11T06:45Z", "family": "Visibility", "description": "A CTR01 point (local reference, treated as a target) is missing at sunrise: its measurement is rejected for one acquisition (error_value just above the threshold), then comes back. The rising sun is in the camera's field, with reflections, and the scene is very dark (seen on the 06:30 image). Probable cause: dazzle from the rising sun. The other targets remain measured. Point to ignore, nothing to do.", "review": "2026-11-17"}
{"start": "2026-08-11T12:45Z", "end": "2026-08-11T17:00Z", "family": "Visibility", "description": "CTR01 (local reference, treated as a target) is rejected a first time in early afternoon, then without interruption in the afternoon: its corr_x and corr_y curves are missing. Its error_value rises from late morning, crosses the threshold, then drops all at once to its night level when the wall goes back into shadow. Same hour and same signature as 12/08, where the thumbnails show the sun on the rock around the target. The other targets remain measured and their curves show nothing of their own. The structure does not move: nothing to do, CTR01's curve is missing every sunny afternoon.", "review": "2026-11-17"}
{"start": "2026-08-12T05:45Z", "end": "2026-08-12T06:15Z", "family": "Visibility", "description": "A CTR01 point (local reference, treated as a target) is missing at sunrise: its measurement is rejected for one acquisition (error_value just above the threshold), then comes back. The rising sun is in the camera's field, with reflections, and the scene is very dark (seen on the 06:00 image). Probable cause: dazzle from the rising sun. The other targets remain measured. Point to ignore, nothing to do.", "review": "2026-11-17"}
{"start": "2026-08-12T05:45Z", "end": "2026-08-13T05:45Z", "family": "Thermal displacement", "description": "Thermal displacement of the camera, poorly compensated. At sunrise, the sun enters the camera's field, facing it (seen on the 05:45, 06:00 and 07:00 images). The camera heats up all at once (housing temperature sharply up at the same moment): its pose jumps (tilt, pan, scale) and the raw positions of all the targets and references move together, then drift throughout the day. The corrected curves are not flattened: corr_x of PR14 to PR18 drops at once then slowly rises back, especially PR18 and PR16; corr_y of PR18 rises; in the morning, those of PR02, PR03, PR05, PR12 and of the references CTR02, CTR03, CTR04 also depart. In late afternoon, when the pose goes back in the opposite direction, a second, weaker bump affects PR18, PR16 and, on the other side, PR01, PR05, PR10. The return continues slowly in the evening and all night: the pan and the corr_x of PR18 and PR16 still rise back until the jump of the next morning. No reference lost, ordinary error_value (the rejections of CTR01 are labelled separately). Deduced cause: the pose and the housing temperature follow the sun, and the rock face cannot move with the temperature. Nothing to do, this is not a movement of the structure.", "review": "2026-11-17"}
{"start": "2026-08-12T13:30Z", "end": "2026-08-12T17:00Z", "family": "Visibility", "description": "CTR01 (local reference, treated as a target) is rejected without interruption in the afternoon: its corr_x and corr_y curves are missing. Its error_value rises from late morning, crosses the threshold, then drops all at once to its night level when the wall goes back into shadow. Seen on the thumbnails: at 13:30 the shadow recedes on the rock around the target, at 14:30 and 16:00 the rock in full sun is as bright as the spot, which drowns in it; at 17:15 the area is in shadow again and the spot sharp. The other targets remain measured and their curves show nothing of their own. The structure does not move: nothing to do, CTR01's curve is missing every sunny afternoon.", "review": "2026-11-17"}
{"start": "2026-08-13T05:45Z", "end": "2026-08-13T06:15Z", "family": "Visibility", "description": "A CTR01 point (local reference, treated as a target) is missing at sunrise: its measurement is rejected for one acquisition (error_value just above the threshold), then comes back. Same hour and same signature as the other mornings, when the rising sun is seen in the camera's field. Probable cause: dazzle from the rising sun. The other targets remain measured. Point to ignore, nothing to do.", "review": "2026-11-17"}
{"start": "2026-08-13T05:45Z", "end": "2026-08-14T05:45Z", "family": "Thermal displacement", "description": "Thermal displacement of the camera, poorly compensated. At sunrise, same signature as the other mornings, when the sun is seen in the camera's field. The camera heats up all at once (housing temperature sharply up at the same moment): its pose jumps (tilt, pan, scale) and the raw positions of all the targets and references move together, then drift throughout the day. The corrected curves are not flattened: corr_x of PR14 to PR18 drops at once then slowly rises back, especially PR18 and PR16; corr_y of PR18 rises, those of PR01, PR02, PR03 and of the references CTR02, CTR03, CTR04 also depart. One of the strongest days of the batch. In late afternoon, when the pose goes back in the opposite direction, a second, weaker bump affects PR18, PR16 and, on the other side, PR01, PR05, PR10. The return continues slowly in the evening and all night: the pan and the corr_x of PR18 and PR16 still rise back until the jump of the next morning. No reference lost, ordinary error_value (the rejections of CTR01 are labelled separately). Deduced cause: the pose and the housing temperature follow the sun, and the rock face cannot move with the temperature. Nothing to do, this is not a movement of the structure.", "review": "2026-11-17"}
{"start": "2026-08-13T13:30Z", "end": "2026-08-13T17:00Z", "family": "Visibility", "description": "CTR01 (local reference, treated as a target) is rejected without interruption in the afternoon: its corr_x and corr_y curves are missing. Its error_value rises from late morning, crosses the threshold, then drops all at once to its night level when the wall goes back into shadow. Same hour and same signature as 12/08, where the thumbnails show the sun on the rock around the target. The other targets remain measured and their curves show nothing of their own. The structure does not move: nothing to do, CTR01's curve is missing every sunny afternoon.", "review": "2026-11-17"}
{"start": "2026-08-14T05:45Z", "end": "2026-08-14T06:30Z", "family": "Visibility", "description": "A CTR01 point (local reference, treated as a target) is missing at sunrise: its measurement is rejected for two acquisitions in a row (error_value just above the threshold), then comes back. Same hour and same signature as the other mornings, when the rising sun is seen in the camera's field. Probable cause: dazzle from the rising sun. The other targets remain measured. Point to ignore, nothing to do.", "review": "2026-11-17"}
{"start": "2026-08-14T05:45Z", "end": "2026-08-15T05:15Z", "family": "Thermal displacement", "description": "Thermal displacement of the camera, poorly compensated. At sunrise, same signature as the other mornings, when the sun is seen in the camera's field. The camera heats up all at once (housing temperature sharply up at the same moment): its pose jumps (tilt, pan, scale) and the raw positions of all the targets and references move together, then drift throughout the day. The corrected curves are not flattened: corr_x of PR14 to PR18 drops at once then slowly rises back, especially PR18 and PR16; corr_y of PR18 rises, those of PR01, PR02, PR03 and of the references CTR02, CTR03, CTR04 also depart. One of the strongest days of the batch. In late afternoon, when the pose goes back in the opposite direction, a second, weaker bump affects PR18, PR16 and, on the other side, PR01, PR05, PR10. The return continues slowly in the evening and all night: the pan still rises back until the jump of the next morning; the corrected curves, however, are almost back as early as the evening. No reference lost, ordinary error_value (the rejections of CTR01 are labelled separately). Deduced cause: the pose and the housing temperature follow the sun, and the rock face cannot move with the temperature. Nothing to do, this is not a movement of the structure.", "review": "2026-11-17"}
{"start": "2026-08-14T13:30Z", "end": "2026-08-14T17:00Z", "family": "Visibility", "description": "CTR01 (local reference, treated as a target) is rejected without interruption in the afternoon: its corr_x and corr_y curves are missing. Its error_value rises from late morning, crosses the threshold, then drops all at once to its night level when the wall goes back into shadow. Same hour and same signature as 12/08, where the thumbnails show the sun on the rock around the target. The other targets remain measured and their curves show nothing of their own. The structure does not move: nothing to do, CTR01's curve is missing every sunny afternoon.", "review": "2026-11-17"}
{"start": "2026-08-15T01:00Z", "end": "2026-08-15T01:30Z", "family": "No data", "description": "No measurement for one acquisition, at night: all the curves are missing. The image of that instant exists, the station synchronised at the same moment (last_sync) and its voltage is normal: neither power cut nor loss of link; the measurement of that instant was simply not produced or exported, cause not established. The same one-measurement gap comes back around the same hour on other nights, outside the batch. The curves resume at the next measurement: nothing to do.", "review": "2026-11-17"}
{"start": "2026-08-15T05:15Z", "end": "2026-08-16T06:30Z", "family": "Thermal displacement", "description": "Thermal displacement of the camera, poorly compensated. At sunrise, same jump as the other mornings. The camera heats up all at once (housing temperature sharply up at the same moment): its pose jumps (tilt, pan, scale) and the raw positions of all the targets and references move together, then drift throughout the day. The corrected curves are not flattened: corr_x of PR14 to PR18 drops at once then slowly rises back, especially PR18 and PR16; corr_y of PR18 rises; in the morning, those of PR01, PR02, PR03, PR09, PR10 and of the references CTR02, CTR04 also depart. Cloudy day (clouds seen on the 10:00 image): the sun comes and goes, the housing temperature drops in late morning then rises again, and the pose and the corrected curves move in jolts; the excursion is weaker than on the previous days. The return continues slowly in the evening and all night: the pan still rises back until the jump of the next morning; the corrected curves, however, are almost back as early as 19:00. No reference lost, ordinary error_value (the rejections of CTR01 are labelled separately). Deduced cause: the pose and the housing temperature follow the sun, and the rock face cannot move with the temperature. Nothing to do, this is not a movement of the structure.", "review": "2026-11-17"}
{"start": "2026-08-15T13:00Z", "end": "2026-08-15T17:00Z", "family": "Visibility", "description": "CTR01 (local reference, treated as a target) is rejected intermittently in the afternoon: its corr_x and corr_y curves are missing. Its error_value rises from late morning, crosses the threshold, then drops all at once to its night level when the wall goes back into shadow. Cloudy day (10:00 image): the rejections follow the sun coming and going on the wall, as on 12/08 when the thumbnails show the sun on the rock around the target. The other targets remain measured and their curves show nothing of their own. The structure does not move: nothing to do, CTR01's curve is missing every sunny afternoon.", "review": "2026-11-17"}
{"start": "2026-08-16T06:30Z", "end": "2026-08-17T07:30Z", "family": "Thermal displacement", "description": "Thermal cycle of the camera, poorly compensated. In the morning, when the housing heats up, the camera turns gradually (tilt rising, pan dropping, scale changing); the raw positions of all the targets and references move together. The compensation does not erase everything: the corr_x of PR16 and PR18 drops a little, the corr_y of PR18 hardly moves, then the curves come back in the afternoon; the camera then comes back slowly, in the evening and all night (the pan rises again), until the start of the next morning. Deduced cause: the pose follows the housing temperature, and the rock face of the quarry cannot move with the temperature. This is not a movement of the structure: nothing to do.", "review": "2026-11-17"}
{"start": "2026-08-16T09:15Z", "end": "2026-08-16T09:45Z", "family": "Visibility", "description": "CTR01 (local reference, treated as a target) is rejected for one measurement in the morning: its curve is missing. On the 09:30 thumbnail, the scene is dark (overcast sky) and the spot of CTR01, already weak, is barely visible, without any obstacle; the other targets remain measured. Cause not established: perhaps the lack of light on this weak target. Points to ignore, nothing to do.", "review": "2026-11-17"}
{"start": "2026-08-16T13:00Z", "end": "2026-08-16T17:00Z", "family": "Visibility", "description": "CTR01 (local reference, treated as a target) is rejected at times in the afternoon: its corr_x and corr_y curves are missing. Seen on the 14:00 thumbnail: the rock around the target is in full sun, as bright as the spot, which drowns in it. The other targets remain measured. The structure does not move: nothing to do, CTR01's curve is missing on sunny afternoons.", "review": "2026-11-17"}
{"start": "2026-08-17T02:30Z", "end": "2026-08-17T10:30Z", "family": "Visibility", "description": "End of night and overcast morning: PR07 is rejected at times from the end of the night, then at dawn CTR01 and PR09 are rejected almost all morning, PR07 and PR01 at times; their curves are missing. At dawn, several targets (PR05, PR06, PR08, PR16) make small jumps on corr_x. On the images, the end of the night is dark and very noisy (04:30), then the sky stays overcast and the spots are weak (07:00, 09:30), without any obstacle. Cause not established (perhaps the lack of light on the weakest targets). The structure does not move: do not trust the curves of these targets over the range, nothing to do.", "review": "2026-11-17"}
{"start": "2026-08-17T07:30Z", "end": "2026-08-18T08:15Z", "family": "Thermal displacement", "description": "Thermal cycle of the camera, poorly compensated. In the morning, when the housing heats up, the camera turns gradually (tilt rising, pan dropping, scale changing); the raw positions of all the targets and references move together. The compensation does not erase everything: the corr_x of PR18 drops a little, the corr_y of PR18 hardly moves, then the curves come back in the afternoon; the camera then comes back slowly, in the evening and all night (the pan rises again), until the start of the next morning. The morning is overcast (07:00 and 09:30 images): the pose starts slowly. Deduced cause: the pose follows the housing temperature, and the rock face of the quarry cannot move with the temperature. This is not a movement of the structure: nothing to do.", "review": "2026-11-17"}
{"start": "2026-08-17T13:30Z", "end": "2026-08-17T15:30Z", "family": "Visibility", "description": "CTR01 (local reference, treated as a target) is rejected at times in the afternoon: its corr_x and corr_y curves are missing. Deduced cause: same hour and same signature as the other sunny afternoons, where the thumbnails show the rock in full sun around the target and the spot drowning in it (16/08, 21 and 22/09). The other targets remain measured. The structure does not move: nothing to do, CTR01's curve is missing on sunny afternoons.", "review": "2026-11-17"}
{"start": "2026-08-18T06:15Z", "end": "2026-08-18T12:15Z", "family": "Visibility", "description": "Morning of poor visibility: CTR01 is rejected all morning, PR07 and PR09 at times, PR14, PR15, PR16 for one or two measurements; the corrected curves of PR16 above all, and of PR15, PR14, PR13, PR08, jump from one measurement to the next. On the 07:45 and 09:45 images, the light is uneven (sun on part of the wall, the rest in shadow) and the spots are weak, without visible obstacle. Cause not established (perhaps the morning light, uneven on the wall). The structure does not move: do not trust the curves over the range.", "review": "2026-11-17"}
{"start": "2026-08-18T08:15Z", "end": "2026-08-19T07:15Z", "family": "Thermal displacement", "description": "Thermal cycle of the camera, poorly compensated. In the morning, when the housing warms up little, the camera turns gradually (tilt rising, pan dropping, scale changing); the raw positions of all the targets and references move together. The compensation does not erase everything: the corr_x of PR18 drops markedly, the corr_y of PR18 hardly moves, then the curves come back in the afternoon; the camera then comes back slowly, in the evening and all night (the pan rises again), until the start of the next morning. Weak day, the housing warms up little: the pose hardly moves and neither does the dip of the corrected curves. At night, the compensation runs for a few hours without the reference CTR03, hidden by the cobweb (labelled separately). Deduced cause: the pose follows the housing temperature, and the rock face of the quarry cannot move with the temperature. This is not a movement of the structure: nothing to do.", "review": "2026-11-17"}
{"start": "2026-08-18T15:15Z", "end": "2026-08-18T16:45Z", "family": "Visibility", "description": "In mid-afternoon, PR07, PR09 and PR11 are rejected for one or two measurements, CTR01 once, and PR13, PR14, PR16 jump on corr_x or corr_y; nothing clear on the 16:00 image (wall in shadow, weak spots). Cause not established, a passing disturbance of the view. The structure does not move: points to ignore.", "review": "2026-11-17"}
{"start": "2026-08-18T17:30Z", "end": "2026-08-19T04:00Z", "family": "Visibility", "description": "A spider weaves its cobweb in front of the lens in early evening: on the images, the cobweb shows as wide blurred bands lit by the infrared (19:00, 21:00, 23:30, 03:00), absent the next day in daylight (10:00). All night, CTR01 is rejected, PR01, PR09, PR02 and PR03 at times: their curves are missing, and PR01 and CTR01 jump a little on corr_y between the rejections. The spider's passage and the hidden reference CTR03 are labelled separately. The structure does not move: do not trust the curves over the range, nothing to do.", "review": "2026-11-17"}
{"start": "2026-08-18T17:45Z", "end": "2026-08-18T18:15Z", "family": "Obstruction", "description": "The spider itself passes in front of the lens at 18:00: its lit body makes a large, blurred white spot in the middle of the image (18:00 image). The reference CTR02 is rejected for the time of this measurement and the compensation runs without it: all the targets jump together on corr_y; the corrections of the remaining references CTR03 and CTR04 fall to zero, as the expert reads it on 04/09, then everything comes back at the next measurement. Point to ignore, this is not a movement.", "review": "2026-11-17"}
{"start": "2026-08-18T22:15Z", "end": "2026-08-19T01:45Z", "family": "Obstruction", "description": "A strip of the cobweb settles on the reference CTR03 (22:30 and 01:00 images, where the lit strip covers it; at 01:15 it has moved away). CTR03 is rejected for several hours and the compensation runs without it: the basis changes, all the targets and the references CTR02 and CTR04 shift at once, mainly on corr_y, and stay on this plateau as long as CTR03 is missing; the raw positions have no step. When CTR03 returns, the curves come back, with a small rebound at the first measurement. The jumps are not a movement: do not trust the curves over the range.", "review": "2026-11-17"}
{"start": "2026-08-19T01:15Z", "end": "2026-08-19T01:45Z", "family": "No data", "description": "One measurement is missing for all the sensors, at night: all the curves have a gap. The image of that instant is missing too, but the station synchronised at that instant (last_sync) and its voltage is normal. No other station has data on that date to compare; cause not established. A gap of one or two measurements comes back around the same hour on many nights of the range. The curves resume at the next measurement: nothing to do.", "review": "2026-11-17"}
{"start": "2026-08-19T06:45Z", "end": "2026-08-19T12:15Z", "family": "Visibility", "description": "CTR01 (local reference, treated as a target) is rejected at times all morning: its curve is missing. On the 07:00 and 10:30 thumbnails, the scene is dark (overcast sky) and the spot of CTR01, already weak, is barely visible, without any obstacle; the other targets remain measured. Cause not established: perhaps the lack of light on this weak target. Points to ignore, nothing to do.", "review": "2026-11-17"}
{"start": "2026-08-19T07:15Z", "end": "2026-08-20T03:45Z", "family": "Thermal displacement", "description": "Thermal cycle of the camera, poorly compensated. In the morning, when the housing warms up little, the camera turns gradually (tilt rising, pan dropping, scale changing); the raw positions of all the targets and references move together. The compensation does not erase everything: the corr_x of PR16 drops a little, the corr_y of PR18 hardly moves, then the curves come back in the afternoon; the camera then comes back slowly, in the evening, then only very little at night, until the start of the next morning. The measurements are missing in the afternoon and a few times at night (gaps labelled separately): the return is only partly seen, under the cobweb of the night (labelled separately). Deduced cause: the pose follows the housing temperature, and the rock face of the quarry cannot move with the temperature. This is not a movement of the structure: nothing to do.", "review": "2026-11-17"}
{"start": "2026-08-19T14:15Z", "end": "2026-08-19T20:15Z", "family": "No data", "description": "No measurement or image for several hours in the afternoon, and the system metrics (voltage, synchronisations, temperatures) are also missing: all the curves are missing. The voltage is normal before and after. According to the data documentation, FLORIDA, MISSISSIPPI and VERMONT have a gap on the same day at the same hour (their data for this date are not in the folder): a common cause outside the station (transmission or reception of the data), not a station failure; it is not established. The curves resume without any offset of their own: nothing to do on the station.", "review": "2026-11-17"}
{"start": "2026-08-19T20:15Z", "end": "2026-08-20T03:45Z", "family": "Visibility", "description": "Cobweb night: on the 22:00 and 02:00 images, very noisy, a lit blurred band crosses the top of the group of targets and blurred discs are at the bottom left. CTR01 is rejected all night, PR07 for a few measurements; the corr_x of PR07 jumps at the start of the night and that of PR08 departs in the second half of the night. The range is cut by measurement gaps (labelled separately). The structure does not move: do not trust these curves over the range.", "review": "2026-11-17"}
{"start": "2026-08-19T20:30Z", "end": "2026-08-19T21:00Z", "family": "No data", "description": "One measurement is missing for all the sensors, just after the resumption from the afternoon gap: all the curves have a gap. The image is missing too, but the station synchronised at that instant (last_sync) and its voltage is normal. No other station has data on that date to compare; cause not established. The curves resume at the next measurement: nothing to do.", "review": "2026-11-17"}
{"start": "2026-08-20T00:30Z", "end": "2026-08-20T01:00Z", "family": "No data", "description": "One measurement is missing for all the sensors, at night: all the curves have a gap. The image of that instant is missing too, but the station synchronised at that instant (last_sync) and its voltage is normal. No other station has data on that date to compare; cause not established. A gap of one or two measurements comes back around the same hour on many nights of the range. The curves resume at the next measurement: nothing to do.", "review": "2026-11-17"}
{"start": "2026-08-20T03:45Z", "end": "2026-08-20T06:15Z", "family": "No data", "description": "No measurement at the end of the night, for a few hours: all the curves are missing from 04:00 to 06:00. The images and the system metrics are missing too from 04:00; the voltage is normal before and after. The image and a synchronisation (last_sync) come back at 06:00, one acquisition before the first measurement (06:15): at that instant the station is running and only the measurement is missing. No other station has data on that date to compare; cause not established. The curves resume without any offset of their own (the pose started with the morning, in the thermal cycle labelled separately): nothing to do."}
{"start": "2026-08-20T06:15Z", "end": "2026-08-21T05:15Z", "family": "Thermal displacement", "description": "Thermal cycle of the camera, poorly compensated. The start of the morning falls in a measurement gap (labelled separately): when measurements resume, the pose has already moved (tilt up, pan down). The raw positions of all the targets and references move together; the compensation does not erase everything, the corr_x of PR18 and PR16 drops a little, then comes back in the afternoon; the camera then comes back slowly, in the evening and all night (the pan rises, the corr_x of PR18 too), until the start of the next morning. Deduced cause: the pose follows the housing temperature, and the rock face of the quarry cannot move with the temperature. This is not a movement of the structure: nothing to do.", "review": "2026-11-17"}
{"start": "2026-08-20T08:00Z", "end": "2026-08-20T09:00Z", "family": "No data", "description": "Three measurements in a row are missing for all the sensors in the morning, the images too, with no synchronisation at those instants; the hourly metrics are there and the voltage is normal. No other station has data on that date to compare; cause not established. The curves then resume: nothing to do.", "review": "2026-11-17"}
{"start": "2026-08-20T14:15Z", "end": "2026-08-20T14:45Z", "family": "Visibility", "description": "CTR01 (local reference, treated as a target) is rejected for one measurement in the afternoon: its corr_x and corr_y curves are missing. Seen on the 14:30 thumbnail: the rock around the target is in full sun, as bright as the spot, which drowns in it. The other targets remain measured. The structure does not move: nothing to do, CTR01's curve is missing on sunny afternoons.", "review": "2026-11-17"}
{"start": "2026-08-20T16:15Z", "end": "2026-08-20T17:15Z", "family": "Visibility", "description": "The sun reaches the wall in late afternoon (16:15, 16:30, 16:45 thumbnails): PR07 disappears and is rejected for one measurement, the corr_x of PR14, PR15 and PR16 jumps for the time of this measurement, PR05 and PR08 a little at the next, then everything comes back. Points to ignore, nothing to do.", "review": "2026-11-17"}
{"start": "2026-08-21T00:30Z", "end": "2026-08-21T01:15Z", "family": "No data", "description": "Two measurements in a row are missing for all the sensors, at night: all the curves have a gap, the images are missing too; the station synchronised at the start of the gap (last_sync) and its voltage is normal. No other station has data on that date to compare; cause not established. A gap of one or two measurements comes back around the same hour on many nights of the range. The curves then resume: nothing to do.", "review": "2026-11-17"}
{"start": "2026-08-21T05:15Z", "end": "2026-08-22T06:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the camera, poorly compensated. In the morning, when the housing heats up, the camera turns all at once (tilt rising, pan dropping, scale changing); the raw positions of all the targets and references move together. The compensation does not erase everything: the corr_x of PR18 drops markedly, the corr_y of PR18 rises, then the curves come back in the afternoon; the camera then comes back slowly, in the evening, then only very little at night, until the start of the next morning. In the evening and at night, the cobweb (labelled separately) makes its own jumps. Deduced cause: the pose follows the housing temperature, and the rock face of the quarry cannot move with the temperature. This is not a movement of the structure: nothing to do.", "review": "2026-11-17"}
{"start": "2026-08-21T12:15Z", "end": "2026-08-21T13:30Z", "family": "Visibility", "description": "CTR01 (local reference, treated as a target) is rejected twice in early afternoon: its curve is missing. On the 12:30 thumbnail, the scene is dark (overcast sky) and the spot of CTR01, already weak, is barely visible, without any obstacle; the other targets remain measured. Cause not established: perhaps the lack of light on this weak target. Points to ignore, nothing to do.", "review": "2026-11-17"}
{"start": "2026-08-21T15:45Z", "end": "2026-08-22T07:30Z", "family": "Visibility", "description": "A cobweb settles in front of the lens in late afternoon: blurred bands are already visible by day (16:45 image), then at night as wide lit bands covering a large part of the scene (18:15, 19:15, 20:30, 03:00); the image becomes sharp again in the morning (07:30). PR07 is rejected from 16:00, CTR01 all night; at dusk, most of the targets are rejected at the same time and the corrected curves of the others jump in both directions; PR08 stays offset on corr_x until the morning. The structure does not move: do not trust the curves over the range, nothing to do.", "review": "2026-11-17"}
{"start": "2026-08-22T06:00Z", "end": "2026-08-23T05:15Z", "family": "Thermal displacement", "description": "Thermal cycle of the camera, poorly compensated. In the morning, when the housing heats up, the camera turns all at once (tilt rising, pan dropping, scale changing); the raw positions of all the targets and references move together. The compensation does not erase everything: the corr_x of PR18, PR14, PR16 and PR15 drops markedly, the corr_y of PR18 rises, then the curves come back in the afternoon; the camera then comes back slowly, in the evening and all night (the pan rises again), until the start of the next morning. The following night is the coldest of the batch: as the housing temperature keeps falling, the camera keeps turning (scale dropping, rotation and pan rising), the registration error rises, and the reference CTR04 slides a little downward against the targets while CTR02 slides the other way; through the compensation, the corr_y of most targets rises a little and stays up from midnight to the end of the night (PR15, PR07, PR10, PR06, PR14, PR16 above all, and the reference CTR02, while CTR03 goes down), then comes back as the housing warms up in the next morning. The targets do not move relative to each other, their error_value stays at its level, and the reference thumbnails show sharp spots, although lit cobweb threads cross the image all night (20:00 and 03:00 images). Deduced cause: the pose follows the housing temperature, and the rock face of the quarry cannot move with the temperature. This is not a movement of the structure: nothing to do."}
{"start": "2026-08-22T16:30Z", "end": "2026-08-22T17:00Z", "family": "No data", "description": "One measurement is missing for all the sensors in late afternoon; the image of that instant exists. The system metrics are missing for several hours from that hour, then the entries waiting to be sent (DB_not_uploaded) accumulate until the next morning before being sent: the station is running, the sending of its data is hindered. According to the data documentation, FLORIDA and MISSISSIPPI also have a gap on the same day around the same hour (their data for this date are not in the folder): a common cause outside the station (transmission or reception of the data), not a station failure; it is not established. The curves resume at the next measurement: nothing to do on the station.", "review": "2026-11-17"}
Binary file not shown.

After

Width:  |  Height:  |  Size: 439 KiB

Binary file not shown.

After

Width:  |  Height:  |  Size: 960 KiB

@@ -0,0 +1,66 @@
# NORDEND: check of the 49 labels, 10 to 23 August
You asked me to check the existing labels of 10/08 01:15 → 23/08 05:15 (UTC): keep, correct, remove or add.
## In short
47 labels hold as they are. Two are corrected, both in their text only: one gap (20/08) and one thermal day (22/08). None is removed, none added.
The curves cannot be trusted on CTR01 on sunny afternoons and sunrises, on the cobweb nights (18→19, 19→20, 21→22/08) and on the dull mornings of 17 and 18/08. Every day the camera moves with the heat of its housing, and the compensation leaves some of it on PR14 to PR18.
No real movement of the quarry face is seen.
## Verification
- Kept: 47. Corrected: 2. Removed: 0. Added: 0.
- **NORDEND-40** (No data, 20/08 03:45 → 06:15): the bounds stay, the text changes. It said the image and the synchronisation come back with the first measurement. In fact they come back at 06:00, one step before the first measurement at 06:15. So the station was running at 06:00 and only the measurement was missing.
- **NORDEND-49** (thermal day, 22/08 06:00 → 23/08 05:15): the bounds and family stay, the text changes. It said that in the cold night only PR10 moves a little in the vertical direction. In fact most targets do: PR15, PR07, PR10, PR06, PR14, PR16 and the reference CTR02 move up together, and CTR03 moves down, from about midnight to the end of the night. This is because the reference CTR04 slides slightly against the targets as the housing reaches the coldest point of the period. The text now names these sensors. It also says that cobweb threads cross the image that night, but the references stay sharp.
- **NORDEND-24** (PR04 target issue, the long label that crosses the range): it holds within the range, from its start on 17/08 05:15 to 23/08 05:15. It is not changed.
- One claim in NORDEND-36 and NORDEND-50 could not be checked: that other stations had a gap at the same time. No other station has data in August in the folder. Their bounds, metrics and images do hold.
## What happened
**The camera follows the heat of its housing, every day.** At sunrise the sun faces the camera, and the housing heats up all at once. The camera turns, and the compensation does not erase it all. The horizontal curves of PR14 to PR18 dip in the morning and come back in the afternoon or during the night. This is strong on the sunny days of 10 to 15/08 and weaker on the dull days that follow. On the coldest night (22→23/08) the vertical curves of most targets rise a little until the morning warming. Confirmed (pose, housing temperature, images of the sun); not a movement of the quarry face.
![Lit cobweb threads at 23:00, each night](nights_2300.png)
Look at the last four images: from 18/08 the infrared lights cobweb threads in front of the lens, every night until the end of the period.
**Cobweb in front of the lens, from 18/08.** On 18→19/08 a spider weaves in front of the camera. At one point it hides the reference CTR02, then a thread hides CTR03 for hours, and all the curves jump together. The web is there every night afterwards. It touches the curves on 19→20 and 21→22/08: targets are rejected and others jump. On 20→21 and 22→23/08 the threads are there but the curves stay calm, apart from PR04 (its own label) and the cold-night shift above. Confirmed on the images.
![Cold night 22→23/08: references against the targets](night_22_23_rigid.png)
Second panel: the reference CTR04 (red) slides down against the targets after midnight, while the targets stay together (grey band).
**CTR01 and the sun.** CTR01 is lost on sunny afternoons, when the sunlit rock around it is as bright as its spot. At sunrise it is lost for one or two points, when the camera faces the sun. On dull days (16, 17, 18, 19, 21/08) its weak spot is lost too, with PR07 and PR09 at times. Confirmed on the images for the sun; likely for the dull mornings.
**Gaps.** There are a few one- or two-step gaps at night (15, 19, 20, 21/08). There are longer ones on 19/08 in the afternoon, on 20/08 at the end of the night and in the morning, and on 22/08. The station keeps its voltage, and on 22/08 it keeps taking images while sending is held back. The cause is not established. The curves resume without any offset.
**Small events.** An animal very close to the lens moves PR12 on the night of 10/08. A disturbance in the afternoon of 18/08 and the sun on the wall late on 20/08 make a few targets jump.
## What to do
Clean the cobweb from the window in front of the lens: it comes back every night from 18/08. Check PR04 on site (its existing label).
## Not established
- Why the measurements are missing during the gaps: whether other stations missed them at the same time would settle it, but no August data from other stations is in the folder.
- The weather station chosen automatically for the place name is in the Valais (Les Marécottes). It may not be near the quarry, so I relied on the camera images instead.
## Labels
| Start (UTC) | End (UTC) | Family | Targets | In a few words |
|---|---|---|---|---|
| 10/08 01:15 | 10/08 02:30 | Obstruction | PR12 | animal at the lens (kept) |
| 10/08 05:30 → 22/08 06:00 | each next morning | Thermal displacement | PR14–PR18 mostly | daily camera cycle, 12 labels (kept) |
| 22/08 06:00 | 23/08 05:15 | Thermal displacement | PR14–PR18; cold night: most targets in y | **corrected text** |
| 10/08 → 14/08, 05:30–06:30 | | Visibility | CTR01 | sunrise dazzle, 5 labels (kept) |
| 10/08 → 20/08 afternoons | | Visibility | CTR01 | sunlit rock, 9 labels (kept) |
| 16/08 09:15, 19/08 06:45, 21/08 12:15 | | Visibility | CTR01 | weak spot, dull sky, 3 labels (kept) |
| 17/08 02:30 | 17/08 10:30 | Visibility | CTR01, PR07, PR09, PR01 | dark dull morning (kept) |
| 18/08 06:15 | 18/08 12:15 | Visibility | CTR01, PR07, PR09, PR14–16 | uneven morning light (kept) |
| 18/08 15:15 | 18/08 16:45 | Visibility | PR07, PR09, PR11, PR13–16 | passing disturbance (kept) |
| 18/08 17:30 | 19/08 04:00 | Visibility | CTR01, PR01–03, PR09 | cobweb night (kept) |
| 18/08 17:45 | 18/08 18:15 | Obstruction | CTR02, all | spider in front (kept) |
| 18/08 22:15 | 19/08 01:45 | Obstruction | CTR03, all | thread on CTR03 (kept) |
| 19/08 20:15 | 20/08 03:45 | Visibility | CTR01, PR07, PR08 | cobweb night (kept) |
| 20/08 16:15 | 20/08 17:15 | Visibility | PR07, PR14–16 | late sun on the wall (kept) |
| 21/08 15:45 | 22/08 07:30 | Visibility | most targets, PR08 | cobweb night (kept) |
| 15/08 01:00 … 22/08 16:30 | | No data | all | 9 gaps (8 kept) |
| 20/08 03:45 | 20/08 06:15 | No data | all | **corrected text** |
@@ -0,0 +1,6 @@
{
"station": "NORDEND",
"start": "2026-08-10T01:15Z",
"end": "2026-08-23T05:15Z",
"hints": "Verify the existing labels of the range (work/existing.jsonl): keep, correct, remove, add."
}
@@ -0,0 +1,26 @@
"""Fast deviations of corr_x/corr_y (vs median of +-N neighbours), flagged instants and coverage by non-thermal labels."""
import sys, json, statistics
sys.path.insert(0, 'tools/scripts')
import data
D = 'labeling/auto/analyses/NORDEND_2026-08-10T0115_2026-08-23T0515/'
S, E = data.parse_time('2026-08-10T01:15Z'), data.parse_time('2026-08-23T05:15Z')
K = float(sys.argv[1]) if len(sys.argv) > 1 else 6
N = int(sys.argv[2]) if len(sys.argv) > 2 else 4
labs = [json.loads(l) for l in open(D + 'work/existing.jsonl')]
labs = [(data.parse_time(l['start']), data.parse_time(l['end']), l['id'], l['family']) for l in labs if l['family'] != 'Thermal displacement']
allm = data.load('data/NORDEND')
flags = {}
for s, ms in allm.items():
ms = data.filter_window(ms, S, E)
for c in ('corr_x', 'corr_y'):
v = [(m['t'], m[c]) for m in ms if m[c] is not None]
if len(v) < 20: continue
noise = statistics.median(abs(v[i+1][1]-v[i][1]) for i in range(len(v)-1))
for i, (t, x) in enumerate(v):
nb = [y for _, y in v[max(0, i-N):i] + v[i+1:i+1+N]]
d = (x - statistics.median(nb)) / noise if noise else 0
if abs(d) > K:
flags.setdefault(t, []).append(f"{s}:{c[-1]}{d:+.0f}")
for t in sorted(flags):
cov = [i for a, b, i, f in labs if a <= t <= b]
print(data.iso(t), len(flags[t]), ' '.join(flags[t]), '| ' + (','.join(cov) if cov else 'UNCOVERED'))
@@ -0,0 +1,18 @@
"""Pose (pan, tilt, scale) at the native step around each morning, and median target corr_x deviation, to check thermal starts."""
import sys, statistics
sys.path.insert(0, 'tools/scripts')
import data
from datetime import timedelta
cam = {p['t']: p for p in data.load_camera('data/NORDEND')}
day0 = data.parse_time('2026-08-10T00:00Z')
h1, h2 = (sys.argv[1], sys.argv[2]) if len(sys.argv) > 2 else ('04:00', '09:30')
for d in range(14):
base = day0 + timedelta(days=d)
a = data.parse_time(base.strftime('%Y-%m-%dT') + h1 + 'Z'); b = data.parse_time(base.strftime('%Y-%m-%dT') + h2 + 'Z')
row = []
t = a
while t <= b:
p = cam.get(t)
row.append(f"{t:%H%M} " + (f"{p['pan']*1000:+.0f}/{p['tilt']*1000:+.0f}/{(p['scale']-1)*1e5:+.0f}" if p else '-'))
t += timedelta(minutes=15)
print(base.strftime('%d/%m'), ' '.join(row))
@@ -0,0 +1,15 @@
"""Contact sheet of whole camera images (downscaled): sheet.py OUT.png TIME1 TIME2 ... (YYYYMMDDTHHMM)."""
import sys, os, glob
import matplotlib; matplotlib.use('Agg')
import matplotlib.pyplot as plt
import matplotlib.image as mpimg
out, times = sys.argv[1], sys.argv[2:]
n = len(times); cols = 3; rows = (n + cols - 1) // cols
fig, axs = plt.subplots(rows, cols, figsize=(cols * 6, rows * 4))
for ax in axs.flat: ax.axis('off')
for ax, t in zip(axs.flat, times):
f = sorted(glob.glob(f'data/NORDEND/images/{t}Z_*.jpg'))
if not f: ax.set_title(t + ' none'); continue
im = mpimg.imread(f[0])[::4, ::4]
ax.imshow(im, cmap='gray', vmin=0, vmax=255); ax.set_title(t)
plt.tight_layout(); plt.savefig(out, dpi=60); print(out)
@@ -0,0 +1,17 @@
"""Write labels.jsonl: existing labels kept as they are (without id), two corrected (review dropped)."""
import json
D = 'labeling/auto/analyses/NORDEND_2026-08-10T0115_2026-08-23T0515/'
fix = {
"NORDEND-40": "No measurement at the end of the night, for a few hours: all the curves are missing from 04:00 to 06:00. The images and the system metrics are missing too from 04:00; the voltage is normal before and after. The image and a synchronisation (last_sync) come back at 06:00, one acquisition before the first measurement (06:15): at that instant the station is running and only the measurement is missing. No other station has data on that date to compare; cause not established. The curves resume without any offset of their own (the pose started with the morning, in the thermal cycle labelled separately): nothing to do.",
"NORDEND-49": "Thermal cycle of the camera, poorly compensated. In the morning, when the housing heats up, the camera turns all at once (tilt rising, pan dropping, scale changing); the raw positions of all the targets and references move together. The compensation does not erase everything: the corr_x of PR18, PR14, PR16 and PR15 drops markedly, the corr_y of PR18 rises, then the curves come back in the afternoon; the camera then comes back slowly, in the evening and all night (the pan rises again), until the start of the next morning. The following night is the coldest of the batch: as the housing temperature keeps falling, the camera keeps turning (scale dropping, rotation and pan rising), the registration error rises, and the reference CTR04 slides a little downward against the targets while CTR02 slides the other way; through the compensation, the corr_y of most targets rises a little and stays up from midnight to the end of the night (PR15, PR07, PR10, PR06, PR14, PR16 above all, and the reference CTR02, while CTR03 goes down), then comes back as the housing warms up in the next morning. The targets do not move relative to each other, their error_value stays at its level, and the reference thumbnails show sharp spots, although lit cobweb threads cross the image all night (20:00 and 03:00 images). Deduced cause: the pose follows the housing temperature, and the rock face of the quarry cannot move with the temperature. This is not a movement of the structure: nothing to do.",
}
out = []
for l in open(D + 'work/existing.jsonl'):
d = json.loads(l)
i = d.pop('id')
if i in fix:
d.pop('review', None); d['description'] = fix[i]
out.append(d)
with open(D + 'labels.jsonl', 'w') as f:
for d in out: f.write(json.dumps(d, ensure_ascii=False) + '\n')
print(len(out))