NORDEND-243: the error_value of CTR02 and PR01 rises with the jolt at 12:00 (checked on the data), not 'nothing more'

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
maximeandClaude Opus 5.5 committed 2026-11-16 13:26:57 +01:00
1 parent f34616ae38
commit 7591488173
2 files changed
+2 -2

No files matched your search

@@ -1 +1 @@
{"start": "2026-11-05T11:45Z", "end": "2026-11-05T12:15Z", "family": "Displacement", "description": "For the duration of one measurement, at 12:00, in the middle of the camera thermal cycle (labelled separately), the pose makes a jolt: the rotation and the tilt jump then come back at the next measurement, and the raw positions of all sensors, references included, jump together in the image then come back, not quite by the same amount (CTR04 a little apart from the targets). The compensation does not quite erase it: the corr_y of PR01, PR10, PR02, PR04 and PR07 drops markedly, PR11, PR09 and PR17 a little, and the corr_x of PR01 and PR02 rises a little; everything comes back at 12:15. No reference is lost (all three stay in the compensation) and no target is rejected apart from CTR01, rejected as usual; the error_value of PR01, PR09 and CTR02, which comes and goes all morning with no effect on the curves, does nothing more here. On the 12:00 image, sunny day, the targets in shadow, nothing in front of them. Cause not established: a jolt of the camera or of its mount, deduced from the pose. This is not a movement of the structure; points to ignore, the camera is to be watched if it repeats."}
{"start": "2026-11-05T11:45Z", "end": "2026-11-05T12:15Z", "family": "Displacement", "description": "For the duration of one measurement, at 12:00, in the middle of the camera thermal cycle (labelled separately), the pose makes a jolt: the rotation and the tilt jump then come back at the next measurement, and the raw positions of all sensors, references included, jump together in the image then come back, not quite by the same amount (CTR04 a little apart from the targets). The compensation does not quite erase it: the corr_y of PR01, PR10, PR02, PR04 and PR07 drops markedly, PR11, PR09 and PR17 a little, and the corr_x of PR01 and PR02 rises a little; everything comes back at 12:15. No reference is lost (all three stay in the compensation) and no target is rejected apart from CTR01, rejected as usual; the error_value of the reference CTR02 and of PR01, which comes and goes all morning with no effect on the curves, rises clearly at 12:00 with the jolt, under the threshold, and comes back at 12:15; that of PR09 barely moves. On the 12:00 image, sunny day, the targets in shadow, nothing in front of them. Cause not established: a jolt of the camera or of its mount, deduced from the pose. This is not a movement of the structure; points to ignore, the camera is to be watched if it repeats."}