auto: CLARIDEN-12 and MICHIGAN-19 no longer point to labels that do not exist, WILDSTRUBEL-136 no longer repeats its return (review removed on the reworded CLARIDEN-12 and MICHIGAN-19); the analysis copies of the reviews aimsight-app wrote in the 9 stations committed in 9ccd04d, and the removal of WILDSTRUBEL-70's copy, so that each copy matches its final label at HEAD

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
maximeandClaude Opus 5.5 committed 2026-11-18 10:45:57 +01:00
1 parent fed05a7d10
commit de092c8008
17 files changed
+68 -69

No files matched your search

+1 -1
View File
@@ -9,4 +9,4 @@
{"id": "MICHIGAN-1", "start": "2026-10-03T00:00Z", "end": "2026-10-05T16:00Z", "family": "Target issue", "description": "From the start of the data to 5 October at noon, COLH21' and REFH22' give exactly the same positions, the same error_value and the same corrected curves: the two sensors are placed on the same point of a group of spots, and their corr_y is clearly lower than that of their neighbors. At the 16:00 measurement on 5 October, they separate: on the 12:00 and 16:00 thumbnails, the scene is the same, but COLH21' is now centered on the top of the group and REFH22' on the bottom; their corr_y jumps toward that of their neighbors and stays there, their error_value drops. At the same moment, the raw positions of several other targets, including COLH18', change a little without their corrected curves moving, and the camera does not move. Cause deduced, not established: the sensors were reconfigured, and COLH21' and REFH22' were badly configured before, placed on the same point; the jump at 16:00 is the return to normal. For the customer: this is not a movement of the structure; the curves of COLH21' and REFH22' from before 5 October at 16:00 are not to be trusted and cannot be compared with those after; check that the current configuration of these two targets is the right one.", "review": "2026-11-17", "analysis": "MICHIGAN_2026-10-03T0000_2026-10-12T1600"}
{"id": "MICHIGAN-17", "start": "2026-10-04T20:00Z", "end": "2026-10-05T12:00Z", "family": "Thermal displacement", "description": "On 5 October, at the 00:00 measurement, the corr_y of all the targets rises together, a little, most clearly for COLH19N', POUH19N', COLH21'', COLH18S''' and COLH19N''; it partly comes back at 04:00, when the corr_x of several targets (COLH20'', POUH21'', COLH21' and REFH22') rises a little in turn; the corr_y of COLH19N', POUH19N' and COLH19N'' rises a little again at 08:00, then everything is back at 12:00. At the same time, the camera housing temperature drops at once and stays low until it rises again at 12:00, and the camera moves with it: at 00:00 its rotation turns and its tilt goes back a little, at 04:00 and 08:00 it nods forward and its scale drops, at 12:00 it comes back. The raw positions of all the sensors, references included, slide together, the targets without moving relative to each other; the reference REFPOU22 slides a little differently from the targets, and the compensation, still on three references, does not erase all of this movement. COLH21' and REFH22', still placed on the same point (labelled apart), move like the others. Same signature as the night of 6 October (labelled apart). Cause deduced from the curves, the camera pose and the camera housing temperature; nothing in front of the targets on the 00:00 and 08:00 images. Small deviation. For the customer: this is not a movement of the structure, nothing to do.", "review": "2026-11-18", "analysis": "MICHIGAN_2026-10-03T0000_2026-10-12T1600"}
{"id": "MICHIGAN-18", "start": "2026-10-06T00:00Z", "end": "2026-10-06T20:00Z", "family": "Thermal displacement", "description": "On 6 October, at the 04:00 measurement, the corr_y of most targets goes down together, a little, COLH20', COLH21', REFH22', COLH21'', POUH21'' and COLH18S''' the most, and the corr_x of COLH21' and COLH20' rises a little; most come back at 08:00, but the corr_y of COLH18S''' stays low, and a little that of POUH18' and COLH18', until 16:00, and comes back at 20:00. At the same moment, the camera housing temperature makes a brief drop, lowest at 04:00, then rises again until 16:00; the camera nods forward (tilt rising, scale dropping) at 04:00, then comes back gradually until 16:00, and the raw positions of all the sensors, references included, slide together: it is the camera that moves, not the targets; the compensation, still on three references, does not erase all of this movement. The error_value of COLH18', POUH18' and COLH19N' rises a little at 04:00 and returns at 16:00. Same signature as the night of 5 October (labelled apart). Cause deduced from the curves, the camera pose and the camera housing temperature; nothing in front of the targets on the 04:00 image. Small deviation. For the customer: this is not a movement of the structure, nothing to do.", "review": "2026-11-18", "analysis": "MICHIGAN_2026-10-03T0000_2026-10-12T1600"}
{"id": "MICHIGAN-19", "start": "2026-10-08T00:00Z", "end": "2026-10-12T16:00Z", "family": "Displacement", "description": "From 8 to 12 October, the camera gradually nods forward: its tilt rises, its pan and its rotation decrease, and all the targets slide together in the image, shrinking slightly, without moving relative to each other. Until 9 October, on three references, the compensation absorbs most of this movement, but not all: from the 04:00 measurement on 8 October, when the camera takes a clearer step forward, the corr_x of COLH18', POUH18', POUH19N', COLH21', COLH19N' and COLH18S''' rises a little and stays up, the corr_y of POUH19N' goes down a little, and the corrections of the references REF42 and REFG43N move apart. Since the loss of REFPOU22 on 9 October at 12:00 (separate label, which also covers the jump of that measurement), the compensation runs on REF42 and REFG43N alone, which do not follow this movement as the targets do (the scale computed on them even rises): the corr_x of all the targets rises slowly and clearly until the end of the range, under the back-and-forth agitation of the two-reference compensation. Its stop and slight return from the evening of 12 October are labelled apart. Deduced from the curves, the camera pose and the raw positions of the targets; nothing on the images. According to the expert, BREITHORN, MICHIGAN and NEBRASKA are in the same building: the cameras of the three stations tilt together, in the same direction and on the same dates (advance until 12 October, stop and slight backward movement from 13 to 16, resumption from the 17th to the end of the month), which points to a cause common to the building rather than a fault of this camera alone; at equal housing temperature, the cameras are more tilted at the end of the month than in the middle: temperature does not explain it alone, link not established. For the customer: the targets do not move relative to each other, this is not a movement of the structure; the camera tilt is to be monitored, and restoring a third reference will make the curves reliable again.", "review": "2026-11-18", "analysis": "MICHIGAN_2026-10-03T0000_2026-10-12T1600"}
{"id": "MICHIGAN-19", "start": "2026-10-08T00:00Z", "end": "2026-10-12T16:00Z", "family": "Displacement", "description": "From 8 to 12 October, the camera gradually nods forward: its tilt rises, its pan and its rotation decrease, and all the targets slide together in the image, shrinking slightly, without moving relative to each other. Until 9 October, on three references, the compensation absorbs most of this movement, but not all: from the 04:00 measurement on 8 October, when the camera takes a clearer step forward, the corr_x of COLH18', POUH18', POUH19N', COLH21', COLH19N' and COLH18S''' rises a little and stays up, the corr_y of POUH19N' goes down a little, and the corrections of the references REF42 and REFG43N move apart. Since the loss of REFPOU22 on 9 October at 12:00 (separate label, which also covers the jump of that measurement), the compensation runs on REF42 and REFG43N alone, which do not follow this movement as the targets do (the scale computed on them even rises): the corr_x of all the targets rises slowly and clearly until the end of the range, under the back-and-forth agitation of the two-reference compensation. From the evening of 12 October, the camera stops and comes back slightly; this is not labelled apart. Deduced from the curves, the camera pose and the raw positions of the targets; nothing on the images. According to the expert, BREITHORN, MICHIGAN and NEBRASKA are in the same building: the cameras of the three stations tilt together, in the same direction and on the same dates (advance until 12 October, stop and slight backward movement from 13 to 16, resumption from the 17th to the end of the month), which points to a cause common to the building rather than a fault of this camera alone; at equal housing temperature, the cameras are more tilted at the end of the month than in the middle: temperature does not explain it alone, link not established. For the customer: the targets do not move relative to each other, this is not a movement of the structure; the camera tilt is to be monitored, and restoring a third reference will make the curves reliable again.", "analysis": "MICHIGAN_2026-10-03T0000_2026-10-12T1600"}
+1 -1
View File
@@ -93,7 +93,7 @@
{"id": "WILDSTRUBEL-132", "start": "2026-10-01T03:15Z", "end": "2026-10-01T05:45Z", "family": "No data", "description": "No measurement for any sensor during the night, except two isolated measurements at 04:45 and 05:15 before the restart. The station shuts down for lack of energy: just before the outage, the battery is at its lowest and the voltage below its usual night level, and the metrics stop with the measurements; it restarts at sunrise with the solar charge, the compute board still cold (metrics). The curves are missing; nothing moves on the structure, but the station does not have enough energy to last the night: to be checked (battery, panel).", "review": "2026-11-17", "analysis": "WILDSTRUBEL_2026-09-24T0230_2026-10-06T1945"}
{"id": "WILDSTRUBEL-133", "start": "2026-10-01T04:45Z", "end": "2026-10-01T12:30Z", "family": "Thermal displacement", "description": "From sunrise until around noon, the camera moves through thermal effect, as every day: the tilt started to rise (the camera nods down) during the end-of-night outage: a little above its night level at the isolated measurement of 04:45, markedly at 06:00; it goes markedly below its level in late morning (at 10:45) and regains at 12:30 its afternoon level, a little below that of the night. The pan drops a little at sunrise (around 05:00-06:00); the rotation goes above its level around 10:00-10:30 and comes back around 12:30; at 08:30, when all the references are lost together, the pose makes a one-measurement jump (separate label); the scale rises with the temperature (markedly at 11:45) and comes back down only in the afternoon, still above its night level at 19:00. In the image, targets and references move together, as a block: y markedly positive at 06:00, then a little negative at 11:00 (ensemble.py --rigide; the targets move away from the block only barely). The housing temperature rises strongly from 04h to 07h (a little less hot at 09h, again at 11h) and stays hot at 12h: the tilt rises with the warming of the morning and comes back while the housing is still hot; the scale follows the temperature and comes back down with it. The compensation follows: on the corrected curves, the tilt wave explains little: before the loss of PA_8, barely more than the noise on each target, except PB1_2 (markedly on corr_x, over few measurements only); what remains is the daytime agitation, the steps of the loss of PA_8 and the common shift taken that day (separate labels). Cause given by the expert for this station (label of 27/09): the camera moves through thermal effect, on its lens or its mount; the road does not move with temperature. Normal, nothing to do.", "review": "2026-11-17", "analysis": "WILDSTRUBEL_2026-09-24T0230_2026-10-06T1945"}
{"id": "WILDSTRUBEL-135", "start": "2026-10-01T08:15Z", "end": "2026-10-01T13:15Z", "family": "Visibility", "description": "The reference PA_8 is rejected continuously from 08:30 to 13:00: the compensation runs without it, and the basis changes. PA_9, its neighbour in the image, rises markedly on corr_x and y stays on a step throughout the range; PA2_2, PA3_2, PB2_2 and PB_5 rise a little. At 08:30 and 09:15, all the references are lost together (08:30 image darker, the scene in shadow, with no obstacle): all targets jump for the time of one measurement, PA_9 especially. Everything comes back in part at 13:15, when PA_8 is taken again; PA_9 stays a little above its morning level until the evening. Cause: PA_8 poorly seen in full daylight, its spot faint on the background (14:00 thumbnail). The step is not a movement: curves of PA_9, PA2_2, PA3_2, PB2_2 and PB_5 not to be trusted over the range.", "review": "2026-11-17", "analysis": "WILDSTRUBEL_2026-09-24T0230_2026-10-06T1945"}
{"id": "WILDSTRUBEL-136", "start": "2026-10-01T13:00Z", "end": "2026-10-01T13:30Z", "family": "Perturbation", "description": "When the reference PA_8 is taken again, on 01/10 at 13:15, all the targets find themselves shifted from their level of late September, with the six references in the compensation: corr_y lower for all of them, together; corr_x higher for PA_9 and PA2_2, lower for PB1_2 and PB_5. The shift occurred between the night and noon, under the thermal movement of the morning and the loss of PA_8 (labelled separately): it cannot be dated more precisely. Relative to the overall movement of the targets, the references PA1_2 and PA_8 moved apart a little, mostly vertically, and R1 horizontally, whereas they followed it the evening before: the basis of references has changed a little, and all the targets inherit it together. The shift remains on 02/10 and 03/10 and fades on 04/10 (return labelled separately). Cause not established (a remainder of the camera movement poorly compensated, or a change in the appearance of these references). The shift fades on 04/10 (return labelled separately): nothing to do, do not read these days as a movement.", "analysis": "WILDSTRUBEL_2026-09-24T0230_2026-10-06T1945"}
{"id": "WILDSTRUBEL-136", "start": "2026-10-01T13:00Z", "end": "2026-10-01T13:30Z", "family": "Perturbation", "description": "When the reference PA_8 is taken again, on 01/10 at 13:15, all the targets find themselves shifted from their level of late September, with the six references in the compensation: corr_y lower for all of them, together; corr_x higher for PA_9 and PA2_2, lower for PB1_2 and PB_5. The shift occurred between the night and noon, under the thermal movement of the morning and the loss of PA_8 (labelled separately): it cannot be dated more precisely. Relative to the overall movement of the targets, the references PA1_2 and PA_8 moved apart a little, mostly vertically, and R1 horizontally, whereas they followed it the evening before: the basis of references has changed a little, and all the targets inherit it together. The shift remains on 02/10 and 03/10 and fades on 04/10 (return labelled separately). Cause not established (a remainder of the camera movement poorly compensated, or a change in the appearance of these references). Nothing to do: do not read these days as a movement.", "analysis": "WILDSTRUBEL_2026-09-24T0230_2026-10-06T1945"}
{"id": "WILDSTRUBEL-227", "start": "2026-10-01T13:45Z", "end": "2026-10-01T14:15Z", "family": "Visibility", "description": "The reference PA_8 is set aside again for the time of one measurement, after its long loss of the late morning (separate label): its spot is faint on the 14:00 thumbnail. The basis changes: PA2_2 and PB1_2 jump on corr_x, PA_9 and PA3_2 a little. Everything comes back at the next measurement. Cause: PA_8 poorly seen in daylight, as the same morning. The structure is not moving: point to ignore.", "review": "2026-11-18", "analysis": "WILDSTRUBEL_2026-09-24T0230_2026-10-06T1945"}
{"id": "WILDSTRUBEL-137", "start": "2026-10-01T21:30Z", "end": "2026-10-02T05:15Z", "family": "No data", "description": "No measurement for any sensor during the night, except one isolated measurement at 04:45. The station shuts down for lack of energy: just before the outage, the battery is at its lowest and the voltage below its usual night level, and the metrics stop with the measurements; it restarts at sunrise with the solar charge, the compute board still cold (metrics). The curves are missing; nothing moves on the structure, but the station does not have enough energy to last the night: to be checked (battery, panel).", "review": "2026-11-17", "analysis": "WILDSTRUBEL_2026-09-24T0230_2026-10-06T1945"}
{"id": "WILDSTRUBEL-138", "start": "2026-10-02T04:45Z", "end": "2026-10-02T13:00Z", "family": "Thermal displacement", "description": "From sunrise until around noon, the camera moves through thermal effect, as every day: its tilt (the camera nods down) is already high at the isolated measurement of 04:45, highest at 06:15, markedly above its afternoon rest; it goes markedly below this rest in late morning (at 11:30) and regains it at 13:00. The pan is a little lower than in the afternoon in the morning (around 05:15); the rotation goes markedly above its level (at 10:15) and comes back at 13:00; the scale rises with the temperature (markedly at 08:30) and comes back down in the afternoon, at its level around 17:30. In the image, targets and references move together, as a block: y markedly positive at 06:15, then a little negative at 11:30 (ensemble.py --rigide; the targets move away from the block only barely). The housing temperature rises strongly from 04h to 09h and stays hot at 13h: the tilt rises with the warming of the morning and comes back while the housing is still hot; the scale follows the temperature and comes back down with it. The compensation follows: on the corrected curves, the tilt wave explains little, apart from the steps of the loss of PA_8 (from 06:00 to 13:00) and of the first measurements without PA1_2 or PA_8, which make the targets jump; these episodes and the daytime agitation are labelled separately. Cause given by the expert for this station (label of 27/09): the camera moves through thermal effect, on its lens or its mount; the road does not move with temperature. Normal, nothing to do.", "review": "2026-11-17", "analysis": "WILDSTRUBEL_2026-09-24T0230_2026-10-06T1945"}
@@ -1,11 +1,11 @@
{"start": "2026-10-11T09:45Z", "end": "2026-10-11T10:15Z", "family": "Visibility", "description": "r1_r, one of the only two references of the station, sees its error_value rise above the threshold for the duration of one measurement, in the morning: it is rejected and the camera is no longer registered. The corrected curves are then computed on p1_r alone: the corr_x of Sellette 5 and Sellette 4 jump a little and return at the next registration. Pont Ernen, the twin of r1_r, leaves its usual zero when it is not rejected too. Raw positions of the targets without a step. Cause not established. With a single reference, no measurement is possible: data of the range not to be trusted; this is not a movement. If it repeats, check the prism r1_r.", "review": "2026-11-17"}
{"start": "2026-10-11T09:45Z", "end": "2026-10-11T22:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day; the corr_x of Sellette 5 goes down a little during the day and returns in the evening. Deduced: the camera movement follows the housing temperature, ordinary error_value outside the other episodes. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-12T00:30Z", "end": "2026-10-12T01:00Z", "family": "Obstruction", "description": "At night, the raw position of the reference p1_r, one of the only two references of the station, shifts for one measurement while the targets do not move in the image (rigid fit on the targets) and its error_value does not rise: the camera pose jumps (pan, tilt, scale) and the corr_x of Sellette 4 and Sellette 5 jump clearly upward together, their corr_y a little, then come back at the next one. On the thumbnails of the hours of this night, a small bright point just beside the spot of p1_r is there at the measurements without a jump and absent at those with a jump: the measurement of p1_r is disturbed by this neighbouring point; its nature is not established. Same jumps later this night, labeled apart. It is not a movement of the structure: points to ignore."}
{"start": "2026-10-12T01:45Z", "end": "2026-10-12T03:00Z", "family": "Obstruction", "description": "At night, the raw position of the reference p1_r, one of the only two references of the station, shifts for one measurement, then again a little later while the targets do not move in the image (rigid fit on the targets) and its error_value does not rise: the camera pose jumps (pan, tilt, scale) and the corr_x of Sellette 4 and Sellette 5 jump clearly upward together, their corr_y a little, then come back in between only halfway, fully after the second. On the thumbnails of the hours of this night, a small bright point just beside the spot of p1_r is there at the measurements without a jump and absent at those with a jump: the measurement of p1_r is disturbed by this neighbouring point; its nature is not established. Seen on the thumbnails of 01:00, 02:00 and 03:00. It is not a movement of the structure: points to ignore."}
{"start": "2026-10-12T03:45Z", "end": "2026-10-12T04:30Z", "family": "Obstruction", "description": "At night, the raw position of the reference p1_r, one of the only two references of the station, shifts for one measurement while the targets do not move in the image (rigid fit on the targets) and its error_value does not rise: the camera pose jumps (pan, tilt, scale) and the corr_x of Sellette 4 and Sellette 5 jump clearly upward together, their corr_y a little, then come back over the next two. On the thumbnails of the hours of this night, a small bright point just beside the spot of p1_r is there at the measurements without a jump and absent at those with a jump: the measurement of p1_r is disturbed by this neighbouring point; its nature is not established. Seen on the thumbnails of 03:00 and 04:00. It is not a movement of the structure: points to ignore."}
{"start": "2026-10-12T06:15Z", "end": "2026-10-12T06:45Z", "family": "Obstruction", "description": "At night, the raw position of the reference p1_r, one of the only two references of the station, shifts for one measurement while the targets do not move in the image (rigid fit on the targets) and its error_value does not rise: the camera pose jumps (pan, tilt, scale) and the corr_x of Sellette 4 and Sellette 5 jump clearly upward together, their corr_y a little, then come back at the next one. On the thumbnails of the hours of this night, a small bright point just beside the spot of p1_r is there at the measurements without a jump and absent at those with a jump: the measurement of p1_r is disturbed by this neighbouring point; its nature is not established. Same jumps earlier this night, labeled apart. It is not a movement of the structure: points to ignore."}
{"start": "2026-10-12T00:30Z", "end": "2026-10-12T01:00Z", "family": "Obstruction", "description": "At night, the raw position of the reference p1_r, one of the only two references of the station, shifts for one measurement while the targets do not move in the image (rigid fit on the targets) and its error_value does not rise: the camera pose jumps (pan, tilt, scale) and the corr_x of Sellette 4 and Sellette 5 jump clearly upward together, their corr_y a little, then come back at the next one. On the thumbnails of the hours of this night, a small bright point just beside the spot of p1_r is there at the measurements without a jump and absent at those with a jump: the measurement of p1_r is disturbed by this neighbouring point; its nature is not established. Same jumps later this night, labeled apart. It is not a movement of the structure: points to ignore.", "review": "2026-11-18"}
{"start": "2026-10-12T01:45Z", "end": "2026-10-12T03:00Z", "family": "Obstruction", "description": "At night, the raw position of the reference p1_r, one of the only two references of the station, shifts for one measurement, then again a little later while the targets do not move in the image (rigid fit on the targets) and its error_value does not rise: the camera pose jumps (pan, tilt, scale) and the corr_x of Sellette 4 and Sellette 5 jump clearly upward together, their corr_y a little, then come back in between only halfway, fully after the second. On the thumbnails of the hours of this night, a small bright point just beside the spot of p1_r is there at the measurements without a jump and absent at those with a jump: the measurement of p1_r is disturbed by this neighbouring point; its nature is not established. Seen on the thumbnails of 01:00, 02:00 and 03:00. It is not a movement of the structure: points to ignore.", "review": "2026-11-18"}
{"start": "2026-10-12T03:45Z", "end": "2026-10-12T04:30Z", "family": "Obstruction", "description": "At night, the raw position of the reference p1_r, one of the only two references of the station, shifts for one measurement while the targets do not move in the image (rigid fit on the targets) and its error_value does not rise: the camera pose jumps (pan, tilt, scale) and the corr_x of Sellette 4 and Sellette 5 jump clearly upward together, their corr_y a little, then come back over the next two. On the thumbnails of the hours of this night, a small bright point just beside the spot of p1_r is there at the measurements without a jump and absent at those with a jump: the measurement of p1_r is disturbed by this neighbouring point; its nature is not established. Seen on the thumbnails of 03:00 and 04:00. It is not a movement of the structure: points to ignore.", "review": "2026-11-18"}
{"start": "2026-10-12T06:15Z", "end": "2026-10-12T06:45Z", "family": "Obstruction", "description": "At night, the raw position of the reference p1_r, one of the only two references of the station, shifts for one measurement while the targets do not move in the image (rigid fit on the targets) and its error_value does not rise: the camera pose jumps (pan, tilt, scale) and the corr_x of Sellette 4 and Sellette 5 jump clearly upward together, their corr_y a little, then come back at the next one. On the thumbnails of the hours of this night, a small bright point just beside the spot of p1_r is there at the measurements without a jump and absent at those with a jump: the measurement of p1_r is disturbed by this neighbouring point; its nature is not established. Same jumps earlier this night, labeled apart. It is not a movement of the structure: points to ignore.", "review": "2026-11-18"}
{"start": "2026-10-12T07:45Z", "end": "2026-10-12T22:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day; the corr_x of Sellette 5 goes down during the day, the corr_y of Sellette 4 a little, and returns in the evening. Deduced: the camera movement follows the housing temperature, ordinary error_value outside the other episodes. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-12T22:15Z", "end": "2026-10-12T22:45Z", "family": "Obstruction", "description": "At night, the raw position of the reference p1_r, one of the only two references of the station, shifts for one measurement while the targets do not move in the image (rigid fit on the targets) and its error_value does not rise: the camera pose jumps (pan, tilt, scale) and the corr_x of Sellette 4 and Sellette 5 jump clearly upward together, their corr_y a little, then come back at the next one. On the thumbnails of the hours of this night, a small bright point just beside the spot of p1_r is there at the measurements without a jump and absent at those with a jump: the measurement of p1_r is disturbed by this neighbouring point; its nature is not established. Same signature as the jumps of the previous night; no image at that minute. It is not a movement of the structure: points to ignore."}
{"start": "2026-10-12T22:15Z", "end": "2026-10-12T22:45Z", "family": "Obstruction", "description": "At night, the raw position of the reference p1_r, one of the only two references of the station, shifts for one measurement while the targets do not move in the image (rigid fit on the targets) and its error_value does not rise: the camera pose jumps (pan, tilt, scale) and the corr_x of Sellette 4 and Sellette 5 jump clearly upward together, their corr_y a little, then come back at the next one. On the thumbnails of the hours of this night, a small bright point just beside the spot of p1_r is there at the measurements without a jump and absent at those with a jump: the measurement of p1_r is disturbed by this neighbouring point; its nature is not established. Same signature as the jumps of the previous night; no image at that minute. It is not a movement of the structure: points to ignore.", "review": "2026-11-18"}
{"start": "2026-10-13T08:45Z", "end": "2026-10-13T23:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day; the corr_x of Sellette 5 goes down during the day and returns in the evening. Deduced: the camera movement follows the housing temperature, ordinary error_value outside the other episodes. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-14T01:15Z", "end": "2026-10-14T01:45Z", "family": "No data", "description": "One measurement absent for all sensors, and no image at that moment; the station nevertheless synchronizes at that moment and its voltage is normal: it is running, the measurement is missing; measurements resume at the next one. This one-measurement gap in the night, around 02:00 UTC, falls on the same measurement at FLORIDA and SNCF01 on 09, 14 and 15/10, and only on them; other stations have the same night gap around the same hour in other weeks (JUNGFRAU and NORDEND in early September): a common cause outside the station, at night, is probable; it is not established. Nothing to do on the station if it does not get worse.", "review": "2026-11-17"}
{"start": "2026-10-14T08:45Z", "end": "2026-10-14T20:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day; the corr_x of Sellette 5 goes down during the day and returns in the evening. Deduced: the camera movement follows the housing temperature, ordinary error_value outside the other episodes. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-17"}
@@ -12,7 +12,7 @@
{"start": "2026-10-27T09:00Z", "end": "2026-10-27T09:30Z", "family": "No data", "description": "One measurement absent for all sensors; normal voltage around it. The same gap falls at the same moment on the other stations measuring at that time (CLARIDEN, JUNGFRAU, LENZSPITZE, NORDEND): a common cause outside the station (transmission or reception of the data), not a failure of the station; it is not established. The curves are missing over the range; nothing to do on the station.", "review": "2026-11-17"}
{"start": "2026-10-27T11:30Z", "end": "2026-10-27T20:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day; the corr_x of Sellette 6 goes down clearly in the afternoon, that of Sellette 5 a little, the corr_y of Sellette 5 rises a little, and everything returns in the evening. Deduced: the camera movement follows the housing temperature, ordinary error_value outside the other episodes. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-28T07:00Z", "end": "2026-10-28T10:30Z", "family": "Visibility", "description": "r1_r, one of the only two references of the station, sees its error_value rise above the threshold in the morning, one measurement then nine, after a slow rise of its error_value all night: it is rejected and the camera is no longer registered. The corrected curves are then computed on p1_r alone: the corr_x of Sellette 5 and Sellette 4 (and of Sellette 6 at the first loss) jump a little and return at the next registration. Pont Ernen, the twin of r1_r, leaves its usual zero when it is not rejected too. Raw positions of the targets without a step. Same scenario as the previous mornings; cause not established. With a single reference, no measurement is possible: data of the range not to be trusted; this is not a movement. If it repeats, check the prism r1_r.", "review": "2026-11-17"}
{"start": "2026-10-28T10:15Z", "end": "2026-10-28T19:45Z", "family": "Thermal displacement", "description": "Thermal cycle of the day, small: with the clear rise of the housing temperature in the morning, the camera pose turns (mostly the rotation, the tilt a little, the pan hardly moves) until the early afternoon, then returns in the late afternoon; the corr_y of Sellette 5 rises during the day and comes back toward its night level in the evening, the corr_x of Sellette 5 and Sellette 4 rise a little with it. The start is hidden under the loss of r1_r of the morning (separate label); the pose has already turned at the first registration after it. Deduced: the pose and the curves follow the housing temperature and come back with it, error_value at its level, the references calm. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do."}
{"start": "2026-10-28T10:15Z", "end": "2026-10-28T19:45Z", "family": "Thermal displacement", "description": "Thermal cycle of the day, small: with the clear rise of the housing temperature in the morning, the camera pose turns (mostly the rotation, the tilt a little, the pan hardly moves) until the early afternoon, then returns in the late afternoon; the corr_y of Sellette 5 rises during the day and comes back toward its night level in the evening, the corr_x of Sellette 5 and Sellette 4 rise a little with it. The start is hidden under the loss of r1_r of the morning (separate label); the pose has already turned at the first registration after it. Deduced: the pose and the curves follow the housing temperature and come back with it, error_value at its level, the references calm. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-18"}
{"start": "2026-10-29T06:45Z", "end": "2026-10-29T18:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day; the corr_y of Sellette 5 rises during the day and returns in the evening. Deduced: the camera movement follows the housing temperature, ordinary error_value outside the other episodes. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-30T07:45Z", "end": "2026-10-30T19:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day; the corr_y of Sellette 5 rises during the day and returns in the evening. Deduced: the camera movement follows the housing temperature, ordinary error_value outside the other episodes. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-31T06:45Z", "end": "2026-10-31T19:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day; the corr_y of Sellette 5 rises during the day and returns in the evening. Deduced: the camera movement follows the housing temperature, ordinary error_value outside the other episodes. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-17"}
@@ -1,6 +1,6 @@
{"start": "2026-10-10T16:15Z", "end": "2026-10-11T07:30Z", "family": "Thermal displacement", "description": "Cooling of the night: the corr_y of the bridge targets rises steadily until morning, the camera tilt follows. Deduced from the curves and the camera housing temperature, which drops: the bridge rises as it cools. Normal, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-11T07:30Z", "end": "2026-10-11T16:15Z", "family": "Thermal displacement", "description": "Warming of the day: the corr_y of the bridge targets sinks until the middle of the afternoon, then stays flat until nightfall; the camera pose follows. Deduced from the curves and the camera housing temperature. Normal, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-11T16:15Z", "end": "2026-10-12T07:30Z", "family": "Thermal displacement", "description": "Cooling of the evening and the night: from late afternoon the camera tilt rises again while the corr_y of the bridge targets stays at its trough, then from nightfall the corr_y of the bridge targets rises until morning, the camera tilt too; references stable, very stable error_value. Deduced from the curves and the camera housing temperature, which drops from late afternoon: the bridge rises as it cools, and the camera fixed to it compensates it poorly. Normal, nothing to do."}
{"start": "2026-10-11T16:15Z", "end": "2026-10-12T07:30Z", "family": "Thermal displacement", "description": "Cooling of the evening and the night: from late afternoon the camera tilt rises again while the corr_y of the bridge targets stays at its trough, then from nightfall the corr_y of the bridge targets rises until morning, the camera tilt too; references stable, very stable error_value. Deduced from the curves and the camera housing temperature, which drops from late afternoon: the bridge rises as it cools, and the camera fixed to it compensates it poorly. Normal, nothing to do.", "review": "2026-11-18"}
{"start": "2026-10-12T07:30Z", "end": "2026-10-12T17:45Z", "family": "Thermal displacement", "description": "Warming of the day: the corr_y of the bridge targets sinks strongly all day, the corr_x of most rises in the afternoon then returns; the camera pose follows. References stable, ordinary error_value. Deduced from the curves and the camera housing temperature. Normal, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-12T15:45Z", "end": "2026-10-12T16:15Z", "family": "Visibility", "description": "Small one-measurement jump on the corr_x of several targets (BJ_C, BJ_G, BL_G, PBJ_C, PBL_D, PM_D), then return. The error_value of the reference REF_G rises for the duration of one measurement, under its threshold: on the 16:00 thumbnail, the background behind it is lit by the sun and its spot drowns in it; the compensation is slightly distorted by it. This is not a movement; nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-12T17:45Z", "end": "2026-10-13T07:15Z", "family": "Thermal displacement", "description": "Cooling of the night: the corr_y of the bridge targets rises steadily until morning, the camera tilt follows. Deduced from the curves and the camera housing temperature, which drops: the bridge rises as it cools. Normal, nothing to do.", "review": "2026-11-17"}
@@ -12,22 +12,22 @@
{"start": "2026-10-14T09:15Z", "end": "2026-10-14T09:45Z", "family": "No data", "description": "One measurement is missing for all sensors, and the image of that moment too; the station nevertheless synchronizes at that moment and its voltage is normal (metrics): it is running, the measurement is not made or not recorded; only station affected that day at that hour, cause not established. The curves resume at the next measurement: nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-14T15:45Z", "end": "2026-10-14T16:15Z", "family": "Visibility", "description": "Small one-measurement jump on the corr_x of several targets (BJ_G, BL_G, PBJ_C, PM_C, PM_D), then return. The error_value of the reference REF_G rises for the duration of one measurement: on the 16:00 thumbnail, the background behind it is in full sun and its spot drowns in it. This is not a movement; nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-14T16:45Z", "end": "2026-10-15T08:30Z", "family": "Thermal displacement", "description": "Cooling of the night: the corr_y of the bridge targets rises steadily until morning, the camera tilt follows; the loss of the references in the middle of the night is superimposed on it (separate label), and the underlying trend remains this cooling. Deduced from the curves and the camera housing temperature, which drops. Normal, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-14T23:00Z", "end": "2026-10-15T08:00Z", "family": "Visibility", "description": "Two references lost, the camera is blind: the error_value of REF_G then REF_D rises strongly, the reprojection error rises first; REF_G is rejected, then REF_D too (the camera is no longer registered at all for two hours), then REF_G comes back alone with REF_CT (reprojection at zero, two references) before REF_D comes back. All the targets jump in steps on corr_x and corr_y at each switch, then return. Once accepted again, REF_D is still seen poorly, in jolts, until early morning, and the targets (BJ_D, BJ_G, PBJ_C above all) stay a little shifted until it becomes sharp again. The cause of the poor visibility of the references is not established (very humid night at the nearby MeteoSwiss station, no rain). Every measurement of the range is invalid; if it repeats, check the state of the reference prisms."}
{"start": "2026-10-14T23:00Z", "end": "2026-10-15T08:00Z", "family": "Visibility", "description": "Two references lost, the camera is blind: the error_value of REF_G then REF_D rises strongly, the reprojection error rises first; REF_G is rejected, then REF_D too (the camera is no longer registered at all for two hours), then REF_G comes back alone with REF_CT (reprojection at zero, two references) before REF_D comes back. All the targets jump in steps on corr_x and corr_y at each switch, then return. Once accepted again, REF_D is still seen poorly, in jolts, until early morning, and the targets (BJ_D, BJ_G, PBJ_C above all) stay a little shifted until it becomes sharp again. The cause of the poor visibility of the references is not established (very humid night at the nearby MeteoSwiss station, no rain). Every measurement of the range is invalid; if it repeats, check the state of the reference prisms.", "review": "2026-11-18"}
{"start": "2026-10-15T08:30Z", "end": "2026-10-15T17:00Z", "family": "Thermal displacement", "description": "Warming of the day: the corr_y of the bridge targets sinks strongly, the corr_x rises in the afternoon; the camera pose follows. References stable, ordinary error_value. Deduced from the curves and the camera housing temperature. Normal, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-15T09:30Z", "end": "2026-10-15T10:00Z", "family": "No data", "description": "One measurement is missing for all sensors, and the image of that moment too; the station nevertheless synchronizes at that moment and its voltage is normal (metrics): it is running, the measurement is not made or not recorded; only station affected that day at that hour, cause not established. The curves resume at the next measurement: nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-15T15:30Z", "end": "2026-10-15T16:15Z", "family": "Visibility", "description": "Small one-measurement jumps on the corr_x of a few targets (BJ_C, BJ_G, BL_G, PBJ_C), then return: the error_value of the reference REF_G rises for the duration of one measurement, like the other afternoons when the sun lights the background behind it (seen on the 15:45 thumbnail: the background behind it is in full sun and its spot drowns in it). This is not a movement; nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-15T17:00Z", "end": "2026-10-15T22:45Z", "family": "Thermal displacement", "description": "Start of the night cooling: the corr_y of the bridge targets rises steadily from late afternoon, until the measurements stop. Deduced from the curves and the camera housing temperature, which drops. Normal, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-15T22:45Z", "end": "2026-10-16T10:30Z", "family": "No data", "description": "No measurement for any sensor, and no image, for almost twelve hours, on the night of 15 to 16: all the curves are missing. The station metrics continue (normal voltage, regular synchronizations), and the number of unsent entries in its database rises all night then drops to zero in late morning: the station kept running and kept its data, but its measurements for the night are missing from the data. The gap starts at the same time, around 23:00, on the nine stations that were measuring then (LENZSPITZE only has its first measurements in the middle of that night, WILDSTRUBEL is already stopped), and their metrics stop at the same time on most of them; measurements and metrics resume at different times depending on the station, most of them in late morning. It is a common cause outside the stations (transmission or reception of the data), not a shutdown of the stations; it is not established. The curves are missing over the range; nothing to do on the station if it does not repeat.", "review": "2026-11-17"}
{"start": "2026-10-16T10:30Z", "end": "2026-10-16T16:45Z", "family": "Thermal displacement", "description": "Warming of the day: when the measurements resume, the corr_y of the bridge targets sinks until late afternoon, the corr_x rises; the camera housing temperature rises clearly in the early afternoon. Deduced from the curves and the temperature. Normal, nothing to do."}
{"start": "2026-10-16T10:30Z", "end": "2026-10-16T16:45Z", "family": "Thermal displacement", "description": "Warming of the day: when the measurements resume, the corr_y of the bridge targets sinks until late afternoon, the corr_x rises; the camera housing temperature rises clearly in the early afternoon. Deduced from the curves and the temperature. Normal, nothing to do.", "review": "2026-11-18"}
{"start": "2026-10-16T13:30Z", "end": "2026-10-16T14:00Z", "family": "No data", "description": "One measurement is missing for all sensors, and the image of that moment too; the station nevertheless synchronizes at that moment, normal voltage. The same gap falls at the same moment on the other stations measuring at that time (FLORIDA, NORDEND, SNCF01): a common cause outside the station (transmission or reception of the data), not a failure of the station; it is not established. The curves are missing over the range; nothing to do on the station.", "review": "2026-11-17"}
{"start": "2026-10-16T15:30Z", "end": "2026-10-16T16:15Z", "family": "Visibility", "description": "Small one-measurement jumps on the corr_x of several targets (BJ_G, BL_C, BL_G, PBJ_C, PM_C, PM_D), in one direction then the other: the error_value of the reference REF_G rises, under its threshold; on the 15:45 thumbnail, the background behind it is in full sun and its spot drowns in it. This is not a movement; nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-16T16:45Z", "end": "2026-10-18T08:15Z", "family": "Thermal displacement", "description": "Rise over several days with the drop in temperature: after the last warm day, the corr_y of the bridge targets rises almost without stopping for two nights and the day between them, with only a weak dip during the day; the clear thermal phases fade out, then the targets stabilize. The camera housing temperature drops over the whole range, with no more daytime peak. Deduced from the temperature: the bridge rises as it cools. A real movement can reasonably be ruled out; nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-17T00:15Z", "end": "2026-10-17T04:45Z", "family": "Visibility", "description": "The references REF_G and REF_D are seen less well at night: their error_value rises clearly, under the threshold; the corr_x and corr_y of several targets (BJ_C, BJ_G, BL_C, BL_G, PBJ_C, PBL_C, PBL_D) make small common jumps, then return when the references become sharp again. Nothing visible on the thumbnails; cause not established. This is not a movement.", "review": "2026-11-17"}
{"start": "2026-10-18T10:00Z", "end": "2026-10-19T10:15Z", "family": "Visibility", "description": "Visibility drops over the whole scene during a long rain: the error_value of almost all the targets and of the references REF_G and REF_CT rises clearly; PM_C is rejected almost all the time and disappears from the curves, PM_D and PBL_C are at times; the corrections become agitated, with common jumps and a shift of BJ_G, BJ_D, PBJ_C that are not movements. Rain measured at the nearby MeteoSwiss station from late morning to the early hours of 19/10, air close to saturation; seen on the 14:00 image: the road is wet and the scene slightly veiled; on the 21:00 image the background is veiled in grey and the spots have halos, nothing in front of the targets. The error_values stay high until the morning cutoff, after which everything returns. Do not trust the curves over the range."}
{"start": "2026-10-19T08:45Z", "end": "2026-10-19T10:15Z", "family": "No data", "description": "No measurement for any sensor for more than an hour: all the curves are missing; the station nevertheless takes its image at the first missing measurement and synchronizes within the hour, normal voltage around it. The same gap falls at the same moment on the other stations measuring at that time (CLARIDEN, FLORIDA, LENZSPITZE, NIEDERHORN, NORDEND, SNCF01): a common cause outside the station (transmission or reception of the data), not a failure of the station; it is not established. The curves are missing over the range; nothing to do on the station."}
{"start": "2026-10-18T10:00Z", "end": "2026-10-19T10:15Z", "family": "Visibility", "description": "Visibility drops over the whole scene during a long rain: the error_value of almost all the targets and of the references REF_G and REF_CT rises clearly; PM_C is rejected almost all the time and disappears from the curves, PM_D and PBL_C are at times; the corrections become agitated, with common jumps and a shift of BJ_G, BJ_D, PBJ_C that are not movements. Rain measured at the nearby MeteoSwiss station from late morning to the early hours of 19/10, air close to saturation; seen on the 14:00 image: the road is wet and the scene slightly veiled; on the 21:00 image the background is veiled in grey and the spots have halos, nothing in front of the targets. The error_values stay high until the morning cutoff, after which everything returns. Do not trust the curves over the range.", "review": "2026-11-18"}
{"start": "2026-10-19T08:45Z", "end": "2026-10-19T10:15Z", "family": "No data", "description": "No measurement for any sensor for more than an hour: all the curves are missing; the station nevertheless takes its image at the first missing measurement and synchronizes within the hour, normal voltage around it. The same gap falls at the same moment on the other stations measuring at that time (CLARIDEN, FLORIDA, LENZSPITZE, NIEDERHORN, NORDEND, SNCF01): a common cause outside the station (transmission or reception of the data), not a failure of the station; it is not established. The curves are missing over the range; nothing to do on the station.", "review": "2026-11-18"}
{"start": "2026-10-19T10:15Z", "end": "2026-10-19T20:00Z", "family": "Thermal displacement", "description": "Weak warming of the day: the corr_y of the bridge targets goes down slowly until evening, the camera housing temperature rises a little; the camera tilt goes down and stays low. Deduced from the curves and the temperature. Normal, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-19T16:15Z", "end": "2026-10-20T11:00Z", "family": "Visibility", "description": "The three large spots nearest the camera, BJ_C, BJ_G and BJ_D, are seen less well from late afternoon and all night: their error_value rises clearly, and measurement by measurement, in step with it, the corr_x of BJ_G goes down and that of BJ_D rises (the two targets at the edges move apart in opposite directions) and the corr_y of all three goes down, then they come back together when it drops; the error_value of the other targets rises a little, the references stay calm, the camera pose and the housing temperature stay almost flat. The night after the rain is very humid at the nearby MeteoSwiss station; the 00:00 image is slightly veiled in grey, nothing in front of the spots. Cause deduced: a poorer view of these near spots in the humid air, not a thermal movement (the temperature does not change). Everything returns in the late morning of 20/10 as their error_value comes down. This is not a movement; do not trust the curves of BJ_C, BJ_G and BJ_D over the range."}
{"start": "2026-10-19T16:15Z", "end": "2026-10-20T11:00Z", "family": "Visibility", "description": "The three large spots nearest the camera, BJ_C, BJ_G and BJ_D, are seen less well from late afternoon and all night: their error_value rises clearly, and measurement by measurement, in step with it, the corr_x of BJ_G goes down and that of BJ_D rises (the two targets at the edges move apart in opposite directions) and the corr_y of all three goes down, then they come back together when it drops; the error_value of the other targets rises a little, the references stay calm, the camera pose and the housing temperature stay almost flat. The night after the rain is very humid at the nearby MeteoSwiss station; the 00:00 image is slightly veiled in grey, nothing in front of the spots. Cause deduced: a poorer view of these near spots in the humid air, not a thermal movement (the temperature does not change). Everything returns in the late morning of 20/10 as their error_value comes down. This is not a movement; do not trust the curves of BJ_C, BJ_G and BJ_D over the range.", "review": "2026-11-18"}
{"start": "2026-10-19T20:30Z", "end": "2026-10-19T21:30Z", "family": "No data", "description": "Two measurements are missing half an hour apart, with a single measurement between them, for all sensors, and no image at those moments; normal voltage around them. The same gap falls at the same moment on the other stations measuring at that time (CLARIDEN, FLORIDA, LENZSPITZE, NIEDERHORN, NORDEND, SNCF01): a common cause outside the station (transmission or reception of the data), not a failure of the station; it is not established. The curves are missing over the range; nothing to do on the station. The hourly metrics of BREITHORN, MICHIGAN and NEBRASKA are also missing at 21:00.", "review": "2026-11-17"}
{"start": "2026-10-20T11:00Z", "end": "2026-10-20T16:00Z", "family": "Thermal displacement", "description": "Weak warming of the day: the corr_y of the bridge targets (BJ_C, BJ_G, BJ_D above all) goes down until mid-afternoon and BJ_D and BJ_G move apart again in corr_x; the camera housing temperature rises a little. From mid-afternoon, the drop in visibility (separate label) is mixed in and accentuates it. Deduced from the curves and the temperature. Normal, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-20T14:15Z", "end": "2026-10-21T09:15Z", "family": "Visibility", "description": "Visibility drops over the whole scene, mostly at night, during the rain: the error_value of almost all the targets and of the three references rises, very clearly for REF_D (peak in the evening) and REF_G (in jolts all night), without any reference being discarded; PM_C is rejected all evening then at times in the early morning. Seen on the 20:00 image: the background is veiled in gray, like a mist lit by the infrared, and the spots of REF_G and PM_C are smaller than on a clear night. The raw position of REF_G moves away from that of the other references, the camera pose computed from them is distorted and the corrections of many targets move slightly (corr_x of BL_C and PM_D, corr_y of the BJ targets); the thermal cycle of the evening is added and makes the case hard to read. Everything returns in the morning of 21/10. Cause: the rain, measured at the nearby MeteoSwiss station from late afternoon of 20/10 to the morning of 21/10 with air close to saturation, consistent with the grey veil of the night images; the structure does not move, data of the range less reliable, nothing to do."}
{"start": "2026-10-20T14:15Z", "end": "2026-10-21T09:15Z", "family": "Visibility", "description": "Visibility drops over the whole scene, mostly at night, during the rain: the error_value of almost all the targets and of the three references rises, very clearly for REF_D (peak in the evening) and REF_G (in jolts all night), without any reference being discarded; PM_C is rejected all evening then at times in the early morning. Seen on the 20:00 image: the background is veiled in gray, like a mist lit by the infrared, and the spots of REF_G and PM_C are smaller than on a clear night. The raw position of REF_G moves away from that of the other references, the camera pose computed from them is distorted and the corrections of many targets move slightly (corr_x of BL_C and PM_D, corr_y of the BJ targets); the thermal cycle of the evening is added and makes the case hard to read. Everything returns in the morning of 21/10. Cause: the rain, measured at the nearby MeteoSwiss station from late afternoon of 20/10 to the morning of 21/10 with air close to saturation, consistent with the grey veil of the night images; the structure does not move, data of the range less reliable, nothing to do.", "review": "2026-11-18"}
{"start": "2026-10-20T16:00Z", "end": "2026-10-21T10:30Z", "family": "Thermal displacement", "description": "Cooling of the evening and the night: the corr_y of the bridge targets (BJ_C, BJ_G, BJ_D, PBJ_C above all) rises until the middle of the morning of 21/10, BJ_D and BJ_G move closer in corr_x; the drop in visibility of the night (separate label) is superimposed and makes reading difficult. Deduced from the curves and the camera housing temperature, which drops. The bridge rises as it cools: normal, nothing to do.", "review": "2026-11-17"}
@@ -1,21 +1,21 @@
{"start": "2026-10-21T10:30Z", "end": "2026-10-21T16:30Z", "family": "Thermal displacement", "description": "Weak warming of the day: the corr_y of the bridge targets (BJ_C, PM_C, BJ_G, BJ_D) goes down a little until mid-afternoon; the camera housing temperature rises a little in late morning. The basis switches of the early afternoon are separate. Deduced from the curves and the temperature. Normal, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-21T12:45Z", "end": "2026-10-21T14:45Z", "family": "Visibility", "description": "The reference basis hesitates in the early afternoon, during rain: from one measurement to the next, the corrections of all the targets, and those of the references, switch together between two levels, mostly in corr_x (BJ_G, PBJ_C, BL_G, BJ_D), then calm down. The error_value of REF_G rises a little at times, that of REF_CT and of most targets a little too, without rejection. Thumbnails of 12:00 and 14:00: spot of REF_G whole on a light daytime background, nothing in front. Cause: rain likely, deduced from the nearby MeteoSwiss weather station (Nyon / Changins, a few km away), which measures rain at the same hours; no drop is seen on the images. This is not a movement; small deviations not to be trusted."}
{"start": "2026-10-21T12:45Z", "end": "2026-10-21T14:45Z", "family": "Visibility", "description": "The reference basis hesitates in the early afternoon, during rain: from one measurement to the next, the corrections of all the targets, and those of the references, switch together between two levels, mostly in corr_x (BJ_G, PBJ_C, BL_G, BJ_D), then calm down. The error_value of REF_G rises a little at times, that of REF_CT and of most targets a little too, without rejection. Thumbnails of 12:00 and 14:00: spot of REF_G whole on a light daytime background, nothing in front. Cause: rain likely, deduced from the nearby MeteoSwiss weather station (Nyon / Changins, a few km away), which measures rain at the same hours; no drop is seen on the images. This is not a movement; small deviations not to be trusted.", "review": "2026-11-18"}
{"start": "2026-10-21T16:30Z", "end": "2026-10-22T07:30Z", "family": "Thermal displacement", "description": "Cooling of the night: the corr_y of the bridge targets (PBJ_C, PM_C, BJ_C, BJ_D above all) rises from late afternoon to morning; the REF_G disturbance of the evening and that of the middle of the night (separate labels) are superimposed. Deduced from the curves and the camera housing temperature, which drops. The bridge rises as it cools: normal, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-21T16:45Z", "end": "2026-10-21T19:45Z", "family": "Visibility", "description": "At nightfall, during rain, the error_value of REF_G rises in jolts, under its threshold, and the corr_y of most targets (BJ_C, BJ_D, BJ_G, PM_C) jumps from one measurement to the next, in one direction then the other, until early evening. 18:00 thumbnail: spot of REF_G whole, nothing in front. Cause: rain likely, deduced from the nearby MeteoSwiss weather station (Nyon / Changins, a few km away), which measures rain at the same hours. This is not a movement; small deviations not to be trusted."}
{"start": "2026-10-22T00:15Z", "end": "2026-10-22T02:45Z", "family": "Visibility", "description": "REF_G poorly seen at night, and REF_D a little, during rain: their error_value rises clearly, far from the threshold, none is discarded; the targets and REF_CT do not move in error_value. Seen on the 01:30 and 02:15 thumbnails: the spot of REF_G shrinks and pales, that of REF_D a little, with no visible obstacle or veil on the background; that of REF_CT is intact. The camera registration degrades and the corrections of several targets slip slightly (corr_x of BJ_G, PBJ_C, BL_G), then return within two measurements when REF_G becomes sharp again, around 02:30, when the rain stops. Cause: rain likely, deduced from the nearby MeteoSwiss weather station (Nyon / Changins, a few km away), which measures rain at the same hours; the two references are in the open, off the bridge. The structure does not move; it is the reference basis that is disturbed, nothing to do."}
{"start": "2026-10-21T16:45Z", "end": "2026-10-21T19:45Z", "family": "Visibility", "description": "At nightfall, during rain, the error_value of REF_G rises in jolts, under its threshold, and the corr_y of most targets (BJ_C, BJ_D, BJ_G, PM_C) jumps from one measurement to the next, in one direction then the other, until early evening. 18:00 thumbnail: spot of REF_G whole, nothing in front. Cause: rain likely, deduced from the nearby MeteoSwiss weather station (Nyon / Changins, a few km away), which measures rain at the same hours. This is not a movement; small deviations not to be trusted.", "review": "2026-11-18"}
{"start": "2026-10-22T00:15Z", "end": "2026-10-22T02:45Z", "family": "Visibility", "description": "REF_G poorly seen at night, and REF_D a little, during rain: their error_value rises clearly, far from the threshold, none is discarded; the targets and REF_CT do not move in error_value. Seen on the 01:30 and 02:15 thumbnails: the spot of REF_G shrinks and pales, that of REF_D a little, with no visible obstacle or veil on the background; that of REF_CT is intact. The camera registration degrades and the corrections of several targets slip slightly (corr_x of BJ_G, PBJ_C, BL_G), then return within two measurements when REF_G becomes sharp again, around 02:30, when the rain stops. Cause: rain likely, deduced from the nearby MeteoSwiss weather station (Nyon / Changins, a few km away), which measures rain at the same hours; the two references are in the open, off the bridge. The structure does not move; it is the reference basis that is disturbed, nothing to do.", "review": "2026-11-18"}
{"start": "2026-10-22T07:30Z", "end": "2026-10-22T17:30Z", "family": "Thermal displacement", "description": "Warming of a sunny day, the strongest of the week: from the morning, the camera, fixed to the bridge, moves (raw positions of all the sensors, references included, together); the corr_y of the bridge targets (PBJ_C, PM_D, PM_C, BL_D) sinks strongly until late afternoon and their corr_x (PBJ_C, BJ_C, PM_D, BJ_G) rises. The error_value of the targets is at its lowest: they are seen very well. References stable relative to each other. Deduced from the curves, the camera pose and the housing temperature, very hot in the early afternoon. The bridge expands, partly poorly compensated by the camera: normal, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-22T15:15Z", "end": "2026-10-22T15:45Z", "family": "Visibility", "description": "Small one-measurement jump on the corr_x of several targets (BJ_G, BL_G, PBJ_C, PBL_C, PM_C), then return: the error_value of the reference REF_G rises for the duration of one measurement, under its threshold; on the 15:30 thumbnail, the background behind it, and that of REF_CT, are in full sun and its spot drowns in it. This is not a movement; nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-22T17:30Z", "end": "2026-10-23T07:00Z", "family": "Thermal displacement", "description": "Cooling of the night: the camera comes back, the corr_y of the bridge targets (PM_D, PBJ_C, PM_C, BL_D) rises steadily until morning and their corr_x goes back down. Deduced from the curves and the camera housing temperature, which drops. The bridge rises as it cools: normal, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-23T07:00Z", "end": "2026-10-23T16:00Z", "family": "Thermal displacement", "description": "Warming of the day, moderate: the corr_y of the bridge targets (PBJ_C, PM_C, PM_D, BL_D) goes down until mid-afternoon; the drop in visibility of the morning (separate label) is mixed in. Deduced from the curves and the camera housing temperature, which rises a little. Normal, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-23T07:15Z", "end": "2026-10-23T12:15Z", "family": "Visibility", "description": "Drop in visibility in the morning, during rain: the error_value of most targets and of REF_G rises from early morning until late morning, PM_C is rejected three times. The 09:00 image shows a grey scene without shadows and a wet road; on the thumbnails nothing is in front of the targets, and their spots look as they do after the episode. The corrections of most targets and of the references first jump together several times from one measurement to the next; then BJ_G and BJ_D move apart in corr_x in opposite directions, the corr_y of BJ_D sinks and BL_G, PBL_C, PBJ_C stay shifted in corr_x, until late morning; everything comes back when the error_value returns to its level. The drop in corr_y of the morning warming (separate label) is mixed in. Cause: rain, deduced from the wet road on the image and from the rain measured at the nearby MeteoSwiss weather station at the same hours. The structure does not move; curves of the morning not to be trusted, nothing to do."}
{"start": "2026-10-23T07:15Z", "end": "2026-10-23T12:15Z", "family": "Visibility", "description": "Drop in visibility in the morning, during rain: the error_value of most targets and of REF_G rises from early morning until late morning, PM_C is rejected three times. The 09:00 image shows a grey scene without shadows and a wet road; on the thumbnails nothing is in front of the targets, and their spots look as they do after the episode. The corrections of most targets and of the references first jump together several times from one measurement to the next; then BJ_G and BJ_D move apart in corr_x in opposite directions, the corr_y of BJ_D sinks and BL_G, PBL_C, PBJ_C stay shifted in corr_x, until late morning; everything comes back when the error_value returns to its level. The drop in corr_y of the morning warming (separate label) is mixed in. Cause: rain, deduced from the wet road on the image and from the rain measured at the nearby MeteoSwiss weather station at the same hours. The structure does not move; curves of the morning not to be trusted, nothing to do.", "review": "2026-11-18"}
{"start": "2026-10-23T16:00Z", "end": "2026-10-24T06:30Z", "family": "Thermal displacement", "description": "Cooling of the night: the corr_y of the bridge targets (PBJ_C, PM_D, PM_C, BL_D) rises until the middle of the night then stays flat; BJ_G and BJ_D move apart in corr_x in opposite directions; the REF_G disturbance of late evening (separate label) is superimposed. Deduced from the curves and the camera housing temperature, which drops. The bridge rises as it cools: normal, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-23T21:45Z", "end": "2026-10-23T23:45Z", "family": "Visibility", "description": "The reference REF_G is seen slightly less well in late evening, during rain: its error_value rises in jolts, under its threshold, that of most targets a little, and the corr_x of most targets (BL_G, BJ_G, BJ_C, BL_D) makes small common jumps in one direction then the other, with the corrections of the references, then calms down before midnight. On the 22:45 thumbnail the spot of REF_G is a little smaller than at 21:00 and at midnight, nothing in front; REF_CT and BL_D unchanged. Cause: rain likely, deduced from the nearby MeteoSwiss weather station (Nyon / Changins, a few km away), which measures rain at the same hours. This is not a movement; small deviations not to be trusted."}
{"start": "2026-10-24T03:00Z", "end": "2026-10-24T12:45Z", "family": "Visibility", "description": "Slight drop in visibility in the morning, during light rain: the error_value of REF_G rises in jolts, that of several targets (PM_C, PM_D, PBL_C, BL_C) a little; no measurement rejected besides PM_G, references all kept. The corrections of most targets make small common jumps from one measurement to the next all morning, then calm down in the early afternoon. Seen on the 08:00 thumbnail: REF_G sharp, nothing in front. Cause: rain likely, deduced from the nearby MeteoSwiss weather station (Nyon / Changins, a few km away), which measures rain at the same hours all morning. The structure does not move; small deviations not to be trusted, nothing to do."}
{"start": "2026-10-24T06:30Z", "end": "2026-10-24T17:00Z", "family": "Thermal displacement", "description": "Weak warming of a rainy day: the corr_y of the bridge targets goes down from the morning until late afternoon (PBJ_C above all, PM_D, PM_C, BL_D), while the camera housing temperature rises a little in the morning then stays flat; the camera pan rises a little from late morning. The drop in visibility of the morning (separate label) is superimposed until the early afternoon. Deduced from the curves, the housing temperature and the same cycle on the other days of the week. The bridge expands: normal, nothing to do."}
{"start": "2026-10-24T17:00Z", "end": "2026-10-25T00:15Z", "family": "Thermal displacement", "description": "Cooling of the evening: the corr_y of the bridge targets (PBJ_C, PM_D, BL_D, PBL_D) rises from late afternoon until midnight, while the camera housing temperature drops; the rain disturbance from late evening (separate label) is superimposed, and after midnight the thermal part can no longer be separated from it. Deduced from the curves and the housing temperature. The bridge rises as it cools: normal, nothing to do."}
{"start": "2026-10-23T21:45Z", "end": "2026-10-23T23:45Z", "family": "Visibility", "description": "The reference REF_G is seen slightly less well in late evening, during rain: its error_value rises in jolts, under its threshold, that of most targets a little, and the corr_x of most targets (BL_G, BJ_G, BJ_C, BL_D) makes small common jumps in one direction then the other, with the corrections of the references, then calms down before midnight. On the 22:45 thumbnail the spot of REF_G is a little smaller than at 21:00 and at midnight, nothing in front; REF_CT and BL_D unchanged. Cause: rain likely, deduced from the nearby MeteoSwiss weather station (Nyon / Changins, a few km away), which measures rain at the same hours. This is not a movement; small deviations not to be trusted.", "review": "2026-11-18"}
{"start": "2026-10-24T03:00Z", "end": "2026-10-24T12:45Z", "family": "Visibility", "description": "Slight drop in visibility in the morning, during light rain: the error_value of REF_G rises in jolts, that of several targets (PM_C, PM_D, PBL_C, BL_C) a little; no measurement rejected besides PM_G, references all kept. The corrections of most targets make small common jumps from one measurement to the next all morning, then calm down in the early afternoon. Seen on the 08:00 thumbnail: REF_G sharp, nothing in front. Cause: rain likely, deduced from the nearby MeteoSwiss weather station (Nyon / Changins, a few km away), which measures rain at the same hours all morning. The structure does not move; small deviations not to be trusted, nothing to do.", "review": "2026-11-18"}
{"start": "2026-10-24T06:30Z", "end": "2026-10-24T17:00Z", "family": "Thermal displacement", "description": "Weak warming of a rainy day: the corr_y of the bridge targets goes down from the morning until late afternoon (PBJ_C above all, PM_D, PM_C, BL_D), while the camera housing temperature rises a little in the morning then stays flat; the camera pan rises a little from late morning. The drop in visibility of the morning (separate label) is superimposed until the early afternoon. Deduced from the curves, the housing temperature and the same cycle on the other days of the week. The bridge expands: normal, nothing to do.", "review": "2026-11-18"}
{"start": "2026-10-24T17:00Z", "end": "2026-10-25T00:15Z", "family": "Thermal displacement", "description": "Cooling of the evening: the corr_y of the bridge targets (PBJ_C, PM_D, BL_D, PBL_D) rises from late afternoon until midnight, while the camera housing temperature drops; the rain disturbance from late evening (separate label) is superimposed, and after midnight the thermal part can no longer be separated from it. Deduced from the curves and the housing temperature. The bridge rises as it cools: normal, nothing to do.", "review": "2026-11-18"}
{"start": "2026-10-24T21:00Z", "end": "2026-10-25T17:15Z", "family": "Visibility", "description": "Visibility drops over the whole scene, moderately at night (the corr_y of the targets slips from late evening), then strongly all day on 25/10: the error_value of almost all the targets and of the three references (REF_CT, REF_D, REF_G) rises gradually until late afternoon; PM_C is rejected many times, then PM_D, BL_G, BL_C and PBL_C in the afternoon; no reference is discarded, but the raw position of REF_G becomes agitated. Seen on the images: at 15:00 the road is wet (rain) and the scene slightly veiled; on the thumbnails, the spots of the targets shrink through the day, compared with the day before at the same hour. The targets no longer move as a block and their corrections slip, mostly vertically (corr_y of BJ_C, and of PM_D, PM_C, BL_C, PBL_C), apparent movements that are not real. Everything returns within two or three measurements at nightfall: on the 17:00 thumbnail, under the infrared lighting, the spots are full again; the corrections return to their previous level. Cause: rain, seen from the wet road. The structure does not move; curves of the day not to be trusted, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-25T07:30Z", "end": "2026-10-25T16:45Z", "family": "Thermal displacement", "description": "Warming of the day, mixed with rain: the camera housing temperature rises until late afternoon and the corr_y of the bridge targets goes down (BJ_D, BJ_C, BJ_G, PM_D); the drop in visibility of the day (separate label) adds slips that are not real, and the thermal part cannot be separated. Deduced from the temperature and the other days of the week. Normal; curves of the day not to be trusted, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-25T16:45Z", "end": "2026-10-26T10:00Z", "family": "Thermal displacement", "description": "Cooling of the evening and the night: when visibility returns, the corr_y of the bridge targets (BJ_D, BJ_C, PM_D, BJ_G) rises all night and until mid-morning of 26/10, while the camera tilt already goes down; BJ_D goes back down in corr_x; the loss of REF_G during the night (separate label) is superimposed. Deduced from the curves and the camera housing temperature, which drops until morning. The bridge rises as it cools: normal, nothing to do."}
{"start": "2026-10-25T16:45Z", "end": "2026-10-26T10:00Z", "family": "Thermal displacement", "description": "Cooling of the evening and the night: when visibility returns, the corr_y of the bridge targets (BJ_D, BJ_C, PM_D, BJ_G) rises all night and until mid-morning of 26/10, while the camera tilt already goes down; BJ_D goes back down in corr_x; the loss of REF_G during the night (separate label) is superimposed. Deduced from the curves and the camera housing temperature, which drops until morning. The bridge rises as it cools: normal, nothing to do.", "review": "2026-11-18"}
{"start": "2026-10-26T00:00Z", "end": "2026-10-26T07:30Z", "family": "Visibility", "description": "One reference discarded, the basis changes: the error_value of the reference REF_G rises gradually from the start of the night until it exceeds its threshold, that of REF_D also rises, under its threshold; REF_G is rejected for more than three hours: the reprojection error of the two remaining references drops to zero, and all the targets jump together on corr_x and corr_y, then return all at once when REF_G reappears, with a few more jumps while REF_D becomes sharp again. On the 04:00 thumbnail, the spot of REF_G is only a tiny point, while that of the control target BL_D stays whole; nothing in front of the reference; the cause of this loss of brightness is not established. These jumps are not a movement; very bad sign for the measurement, which runs on two references: do not trust the curves over the range.", "review": "2026-11-17"}
{"start": "2026-10-26T10:00Z", "end": "2026-10-26T19:00Z", "family": "Thermal displacement", "description": "Warming of the day: the corr_y of the bridge targets goes down from late morning to evening (PBJ_C, BJ_C, BJ_G, PM_D above all); the camera pose follows the cycle; references stable. Deduced from the curves and the camera housing temperature, which rises during the day. The bridge expands, the camera fixed to it moves with it: normal, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-26T14:15Z", "end": "2026-10-26T15:00Z", "family": "No data", "description": "No measurement for any sensor for two measurement steps, and no image at that hour: all the curves are missing; normal voltage around it. The same gap falls at the same moment on the other stations measuring at that time (CLARIDEN, FLORIDA, LENZSPITZE, NIEDERHORN, NORDEND, SNCF01), and their metrics are also missing at the same minutes: a common cause outside the station (transmission or reception of the data), not a failure of the station; it is not established. The curves are missing over the range; nothing to do on the station. The hourly metrics of BREITHORN, MICHIGAN and NEBRASKA are also missing at 15:00.", "review": "2026-11-17"}
@@ -1,4 +1,4 @@
{"start": "2026-10-03T00:00Z", "end": "2026-10-05T16:00Z", "family": "Target issue", "description": "From the start of the data to 5 October at noon, COLH21' and REFH22' give exactly the same positions, the same error_value and the same corrected curves: the two sensors are placed on the same point of a group of spots, and their corr_y is clearly lower than that of their neighbors. At the 16:00 measurement on 5 October, they separate: on the 12:00 and 16:00 thumbnails, the scene is the same, but COLH21' is now centered on the top of the group and REFH22' on the bottom; their corr_y jumps toward that of their neighbors and stays there, their error_value drops. At the same moment, the raw positions of several other targets, including COLH18', change a little without their corrected curves moving, and the camera does not move. Cause deduced, not established: the sensors were reconfigured, and COLH21' and REFH22' were badly configured before, placed on the same point; the jump at 16:00 is the return to normal. For the customer: this is not a movement of the structure; the curves of COLH21' and REFH22' from before 5 October at 16:00 are not to be trusted and cannot be compared with those after; check that the current configuration of these two targets is the right one.", "review": "2026-11-17"}
{"start": "2026-10-04T20:00Z", "end": "2026-10-05T12:00Z", "family": "Thermal displacement", "description": "On 5 October, at the 00:00 measurement, the corr_y of all the targets rises together, a little, most clearly for COLH19N', POUH19N', COLH21'', COLH18S''' and COLH19N''; it partly comes back at 04:00, when the corr_x of several targets (COLH20'', POUH21'', COLH21' and REFH22') rises a little in turn; the corr_y of COLH19N', POUH19N' and COLH19N'' rises a little again at 08:00, then everything is back at 12:00. At the same time, the camera housing temperature drops at once and stays low until it rises again at 12:00, and the camera moves with it: at 00:00 its rotation turns and its tilt goes back a little, at 04:00 and 08:00 it nods forward and its scale drops, at 12:00 it comes back. The raw positions of all the sensors, references included, slide together, the targets without moving relative to each other; the reference REFPOU22 slides a little differently from the targets, and the compensation, still on three references, does not erase all of this movement. COLH21' and REFH22', still placed on the same point (labelled apart), move like the others. Same signature as the night of 6 October (labelled apart). Cause deduced from the curves, the camera pose and the camera housing temperature; nothing in front of the targets on the 00:00 and 08:00 images. Small deviation. For the customer: this is not a movement of the structure, nothing to do."}
{"start": "2026-10-06T00:00Z", "end": "2026-10-06T20:00Z", "family": "Thermal displacement", "description": "On 6 October, at the 04:00 measurement, the corr_y of most targets goes down together, a little, COLH20', COLH21', REFH22', COLH21'', POUH21'' and COLH18S''' the most, and the corr_x of COLH21' and COLH20' rises a little; most come back at 08:00, but the corr_y of COLH18S''' stays low, and a little that of POUH18' and COLH18', until 16:00, and comes back at 20:00. At the same moment, the camera housing temperature makes a brief drop, lowest at 04:00, then rises again until 16:00; the camera nods forward (tilt rising, scale dropping) at 04:00, then comes back gradually until 16:00, and the raw positions of all the sensors, references included, slide together: it is the camera that moves, not the targets; the compensation, still on three references, does not erase all of this movement. The error_value of COLH18', POUH18' and COLH19N' rises a little at 04:00 and returns at 16:00. Same signature as the night of 5 October (labelled apart). Cause deduced from the curves, the camera pose and the camera housing temperature; nothing in front of the targets on the 04:00 image. Small deviation. For the customer: this is not a movement of the structure, nothing to do."}
{"start": "2026-10-08T00:00Z", "end": "2026-10-12T16:00Z", "family": "Displacement", "description": "From 8 to 12 October, the camera gradually nods forward: its tilt rises, its pan and its rotation decrease, and all the targets slide together in the image, shrinking slightly, without moving relative to each other. Until 9 October, on three references, the compensation absorbs most of this movement, but not all: from the 04:00 measurement on 8 October, when the camera takes a clearer step forward, the corr_x of COLH18', POUH18', POUH19N', COLH21', COLH19N' and COLH18S''' rises a little and stays up, the corr_y of POUH19N' goes down a little, and the corrections of the references REF42 and REFG43N move apart. Since the loss of REFPOU22 on 9 October at 12:00 (separate label, which also covers the jump of that measurement), the compensation runs on REF42 and REFG43N alone, which do not follow this movement as the targets do (the scale computed on them even rises): the corr_x of all the targets rises slowly and clearly until the end of the range, under the back-and-forth agitation of the two-reference compensation. Its stop and slight return from the evening of 12 October are labelled apart. Deduced from the curves, the camera pose and the raw positions of the targets; nothing on the images. According to the expert, BREITHORN, MICHIGAN and NEBRASKA are in the same building: the cameras of the three stations tilt together, in the same direction and on the same dates (advance until 12 October, stop and slight backward movement from 13 to 16, resumption from the 17th to the end of the month), which points to a cause common to the building rather than a fault of this camera alone; at equal housing temperature, the cameras are more tilted at the end of the month than in the middle: temperature does not explain it alone, link not established. For the customer: the targets do not move relative to each other, this is not a movement of the structure; the camera tilt is to be monitored, and restoring a third reference will make the curves reliable again."}
{"start": "2026-10-04T20:00Z", "end": "2026-10-05T12:00Z", "family": "Thermal displacement", "description": "On 5 October, at the 00:00 measurement, the corr_y of all the targets rises together, a little, most clearly for COLH19N', POUH19N', COLH21'', COLH18S''' and COLH19N''; it partly comes back at 04:00, when the corr_x of several targets (COLH20'', POUH21'', COLH21' and REFH22') rises a little in turn; the corr_y of COLH19N', POUH19N' and COLH19N'' rises a little again at 08:00, then everything is back at 12:00. At the same time, the camera housing temperature drops at once and stays low until it rises again at 12:00, and the camera moves with it: at 00:00 its rotation turns and its tilt goes back a little, at 04:00 and 08:00 it nods forward and its scale drops, at 12:00 it comes back. The raw positions of all the sensors, references included, slide together, the targets without moving relative to each other; the reference REFPOU22 slides a little differently from the targets, and the compensation, still on three references, does not erase all of this movement. COLH21' and REFH22', still placed on the same point (labelled apart), move like the others. Same signature as the night of 6 October (labelled apart). Cause deduced from the curves, the camera pose and the camera housing temperature; nothing in front of the targets on the 00:00 and 08:00 images. Small deviation. For the customer: this is not a movement of the structure, nothing to do.", "review": "2026-11-18"}
{"start": "2026-10-06T00:00Z", "end": "2026-10-06T20:00Z", "family": "Thermal displacement", "description": "On 6 October, at the 04:00 measurement, the corr_y of most targets goes down together, a little, COLH20', COLH21', REFH22', COLH21'', POUH21'' and COLH18S''' the most, and the corr_x of COLH21' and COLH20' rises a little; most come back at 08:00, but the corr_y of COLH18S''' stays low, and a little that of POUH18' and COLH18', until 16:00, and comes back at 20:00. At the same moment, the camera housing temperature makes a brief drop, lowest at 04:00, then rises again until 16:00; the camera nods forward (tilt rising, scale dropping) at 04:00, then comes back gradually until 16:00, and the raw positions of all the sensors, references included, slide together: it is the camera that moves, not the targets; the compensation, still on three references, does not erase all of this movement. The error_value of COLH18', POUH18' and COLH19N' rises a little at 04:00 and returns at 16:00. Same signature as the night of 5 October (labelled apart). Cause deduced from the curves, the camera pose and the camera housing temperature; nothing in front of the targets on the 04:00 image. Small deviation. For the customer: this is not a movement of the structure, nothing to do.", "review": "2026-11-18"}
{"start": "2026-10-08T00:00Z", "end": "2026-10-12T16:00Z", "family": "Displacement", "description": "From 8 to 12 October, the camera gradually nods forward: its tilt rises, its pan and its rotation decrease, and all the targets slide together in the image, shrinking slightly, without moving relative to each other. Until 9 October, on three references, the compensation absorbs most of this movement, but not all: from the 04:00 measurement on 8 October, when the camera takes a clearer step forward, the corr_x of COLH18', POUH18', POUH19N', COLH21', COLH19N' and COLH18S''' rises a little and stays up, the corr_y of POUH19N' goes down a little, and the corrections of the references REF42 and REFG43N move apart. Since the loss of REFPOU22 on 9 October at 12:00 (separate label, which also covers the jump of that measurement), the compensation runs on REF42 and REFG43N alone, which do not follow this movement as the targets do (the scale computed on them even rises): the corr_x of all the targets rises slowly and clearly until the end of the range, under the back-and-forth agitation of the two-reference compensation. From the evening of 12 October, the camera stops and comes back slightly; this is not labelled apart. Deduced from the curves, the camera pose and the raw positions of the targets; nothing on the images. According to the expert, BREITHORN, MICHIGAN and NEBRASKA are in the same building: the cameras of the three stations tilt together, in the same direction and on the same dates (advance until 12 October, stop and slight backward movement from 13 to 16, resumption from the 17th to the end of the month), which points to a cause common to the building rather than a fault of this camera alone; at equal housing temperature, the cameras are more tilted at the end of the month than in the middle: temperature does not explain it alone, link not established. For the customer: the targets do not move relative to each other, this is not a movement of the structure; the camera tilt is to be monitored, and restoring a third reference will make the curves reliable again."}
@@ -1,4 +1,4 @@
{"start": "2026-10-03T00:00Z", "end": "2026-10-12T12:00Z", "family": "Displacement", "description": "From the start of the measurements, on 3 October, the corr_x of the targets at the top and the right of the image (COLJ20, POUJ20, POUJ19, COLJ19, then POUH19 and COLH19) rises slowly, without returning, until 12 October around noon; those at the bottom, near the references, hardly move. At the same time, the camera gradually nods forward: its tilt rises, its rotation turns and its scale drops, with a clearer step from the afternoon of 7 October to 8 October, which the compensation absorbs as long as the three references hold (no step on the curves that day). The rise of the targets is weak with three references and clearer after the loss of REFCOLH22 on 9 October (the jump of that day is another label). The raw positions of the targets move mostly with the camera: it is the compensation that renders this movement poorly. The camera housing temperature only drops a little over the phase. According to the expert, BREITHORN, MICHIGAN and NEBRASKA are in the same building: the cameras of the three stations tilt together, in the same direction and on the same dates (advance until 12 October, stop and slight backward movement from 13 to 16, resumption from the 17th to the end of the month), which points to a cause common to the building rather than a fault of this camera alone; at equal housing temperature, the cameras are more tilted at the end of the month than in the middle: temperature does not explain it alone, link not established. Deduced from the curves and the camera pose. For the customer: the camera tilts and the scene deforms with it: a movement of the structure is not established; the camera tilt is to be monitored, and restoring a third reference will make the curves reliable again.", "review": "2026-11-17"}
{"start": "2026-10-04T00:00Z", "end": "2026-10-04T16:00Z", "family": "Thermal displacement", "description": "Cool morning of 4 October: at the 04:00 and 08:00 measurements, the corr_x of the top targets rises together, COLJ20, POUJ20, POUJ19, POUH19 and COLJ19 the most, and the corr_y of POUJ20, POUH19 and COLH19 rises a little while that of COLJ23 goes down a little; at noon the curves are halfway back, POUJ20 and POUJ19 still a little high in corr_x, and everything is back at 16:00. At the same time the camera housing temperature, read in the metrics, makes its morning dip, lowest at 04:00, and rises again at noon; the camera moves with it: it nods forward, its rotation turns and its scale drops, most at 08:00, then it comes back at noon. The three references hold and stay at their place; the raw positions of all the sensors slide together with the camera, the top targets COLJ20 and POUJ20 deviating only slightly from the others: the compensation does not erase all of this camera movement. Nothing in front of the targets on the 08:00 image. According to the expert, BREITHORN, MICHIGAN and NEBRASKA are in the same building: the camera of BREITHORN moves the same morning. Same signature as the cool mornings of 5 and 6 October (labelled apart) and of later in October. Deduced from the curves, the camera pose and the housing temperature, under the slow tilt of the camera labelled apart. The targets do not move: nothing to do, do not trust these points."}
{"start": "2026-10-04T20:00Z", "end": "2026-10-05T16:00Z", "family": "Thermal displacement", "description": "Cool morning of 5 October: from the midnight measurement, the corr_y of the top targets (COLJ20, POUJ19, POUJ20, COLJ19) rises a little and the corr_x of COLJ19 and COLJ23 too; at 08:00 the corr_y rises clearly on POUH19, POUJ20, COLJ19, POUJ19, COLJ20 and COLH20, and the corr_x of COLJ19, POUH19 and COLH21 makes a peak; at noon the corr_y is mostly back, the corr_x of COLJ19 and POUJ19 still a little high, and everything is back at 16:00. At the same time the camera housing temperature, read in the metrics, drops at midnight, is lowest at 04:00 and rises again at noon; the camera moves with it: it nods forward from midnight, most at 08:00, its scale drops and its rotation turns, then it comes back in the afternoon. The three references hold; the raw positions of all the sensors slide together with the camera, COLJ20 and COLJ19 deviating only slightly from the others: the compensation does not erase all of this camera movement. Nothing in front of the targets on the 08:00 image. According to the expert, BREITHORN, MICHIGAN and NEBRASKA are in the same building: the cameras of BREITHORN and MICHIGAN move the same morning. Same signature as the cool mornings of 4 and 6 October (labelled apart). Deduced from the curves, the camera pose and the housing temperature, under the slow tilt of the camera labelled apart. The targets do not move: nothing to do, do not trust these points."}
{"start": "2026-10-05T20:00Z", "end": "2026-10-06T20:00Z", "family": "Thermal displacement", "description": "Cool day of 6 October, longer than the mornings before: from the midnight measurement, the corr_y of POUJ19 goes down clearly and stays low until 16:00, joined by COLJ20 and, in the afternoon, by POUJ20, COLJ19 and POUH19, whose corr_y first rises a little at 04:00; the corr_x of COLJ19 rises clearly from midnight, most at 04:00, and that of COLJ24 a little at 04:00; everything comes back at the 20:00 measurement. The camera housing temperature, read in the metrics, drops at midnight, is lowest at 04:00, then rises slowly and only regains its usual level at 20:00; the camera nods forward from midnight, most at 08:00, its scale drops and its rotation turns, and it is back at 16:00. Checked target by target on the raw positions: all the sensors slide with the camera, but POUJ19 (vertically) and COLJ19 (horizontally) also deviate from the overall movement of the other targets from midnight to 16:00, and come back at 20:00 with the housing temperature rather than with the camera; the three references hold. Nothing in front of the targets on the thumbnails of 08:00 and 16:00, which show POUJ19 and COLJ19 sharp and round, nor on the 08:00 image. According to the expert, BREITHORN, MICHIGAN and NEBRASKA are in the same building: the cameras of BREITHORN and MICHIGAN move the same morning, and on MICHIGAN some curves also stay low until the afternoon. Deduced from the curves, the camera pose, the raw positions and the housing temperature: a camera movement with the cold, incompletely compensated, and a deviation of POUJ19 and COLJ19 that follows the housing temperature and comes back with it, whose origin (the camera optics or these targets) is not established. Same signature as the cool mornings of 4 and 5 October (labelled apart). Everything comes back at equal temperature: nothing to do, do not trust these points."}
{"start": "2026-10-04T00:00Z", "end": "2026-10-04T16:00Z", "family": "Thermal displacement", "description": "Cool morning of 4 October: at the 04:00 and 08:00 measurements, the corr_x of the top targets rises together, COLJ20, POUJ20, POUJ19, POUH19 and COLJ19 the most, and the corr_y of POUJ20, POUH19 and COLH19 rises a little while that of COLJ23 goes down a little; at noon the curves are halfway back, POUJ20 and POUJ19 still a little high in corr_x, and everything is back at 16:00. At the same time the camera housing temperature, read in the metrics, makes its morning dip, lowest at 04:00, and rises again at noon; the camera moves with it: it nods forward, its rotation turns and its scale drops, most at 08:00, then it comes back at noon. The three references hold and stay at their place; the raw positions of all the sensors slide together with the camera, the top targets COLJ20 and POUJ20 deviating only slightly from the others: the compensation does not erase all of this camera movement. Nothing in front of the targets on the 08:00 image. According to the expert, BREITHORN, MICHIGAN and NEBRASKA are in the same building: the camera of BREITHORN moves the same morning. Same signature as the cool mornings of 5 and 6 October (labelled apart) and of later in October. Deduced from the curves, the camera pose and the housing temperature, under the slow tilt of the camera labelled apart. The targets do not move: nothing to do, do not trust these points.", "review": "2026-11-18"}
{"start": "2026-10-04T20:00Z", "end": "2026-10-05T16:00Z", "family": "Thermal displacement", "description": "Cool morning of 5 October: from the midnight measurement, the corr_y of the top targets (COLJ20, POUJ19, POUJ20, COLJ19) rises a little and the corr_x of COLJ19 and COLJ23 too; at 08:00 the corr_y rises clearly on POUH19, POUJ20, COLJ19, POUJ19, COLJ20 and COLH20, and the corr_x of COLJ19, POUH19 and COLH21 makes a peak; at noon the corr_y is mostly back, the corr_x of COLJ19 and POUJ19 still a little high, and everything is back at 16:00. At the same time the camera housing temperature, read in the metrics, drops at midnight, is lowest at 04:00 and rises again at noon; the camera moves with it: it nods forward from midnight, most at 08:00, its scale drops and its rotation turns, then it comes back in the afternoon. The three references hold; the raw positions of all the sensors slide together with the camera, COLJ20 and COLJ19 deviating only slightly from the others: the compensation does not erase all of this camera movement. Nothing in front of the targets on the 08:00 image. According to the expert, BREITHORN, MICHIGAN and NEBRASKA are in the same building: the cameras of BREITHORN and MICHIGAN move the same morning. Same signature as the cool mornings of 4 and 6 October (labelled apart). Deduced from the curves, the camera pose and the housing temperature, under the slow tilt of the camera labelled apart. The targets do not move: nothing to do, do not trust these points.", "review": "2026-11-18"}
{"start": "2026-10-05T20:00Z", "end": "2026-10-06T20:00Z", "family": "Thermal displacement", "description": "Cool day of 6 October, longer than the mornings before: from the midnight measurement, the corr_y of POUJ19 goes down clearly and stays low until 16:00, joined by COLJ20 and, in the afternoon, by POUJ20, COLJ19 and POUH19, whose corr_y first rises a little at 04:00; the corr_x of COLJ19 rises clearly from midnight, most at 04:00, and that of COLJ24 a little at 04:00; everything comes back at the 20:00 measurement. The camera housing temperature, read in the metrics, drops at midnight, is lowest at 04:00, then rises slowly and only regains its usual level at 20:00; the camera nods forward from midnight, most at 08:00, its scale drops and its rotation turns, and it is back at 16:00. Checked target by target on the raw positions: all the sensors slide with the camera, but POUJ19 (vertically) and COLJ19 (horizontally) also deviate from the overall movement of the other targets from midnight to 16:00, and come back at 20:00 with the housing temperature rather than with the camera; the three references hold. Nothing in front of the targets on the thumbnails of 08:00 and 16:00, which show POUJ19 and COLJ19 sharp and round, nor on the 08:00 image. According to the expert, BREITHORN, MICHIGAN and NEBRASKA are in the same building: the cameras of BREITHORN and MICHIGAN move the same morning, and on MICHIGAN some curves also stay low until the afternoon. Deduced from the curves, the camera pose, the raw positions and the housing temperature: a camera movement with the cold, incompletely compensated, and a deviation of POUJ19 and COLJ19 that follows the housing temperature and comes back with it, whose origin (the camera optics or these targets) is not established. Same signature as the cool mornings of 4 and 5 October (labelled apart). Everything comes back at equal temperature: nothing to do, do not trust these points.", "review": "2026-11-18"}
@@ -1,2 +1,2 @@
{"start": "2026-10-09T08:00Z", "end": "2026-11-01T00:00Z", "family": "Target issue", "description": "The reference REFCOLH22 is lost at the 9 October noon measurement and does not come back until the end of the month: its error_value jumps almost to the maximum and all its measurements are rejected. On the thumbnails, its spot, sharp and round until the morning of 9 October, has disappeared from its place at the next measurement, while the neighboring spot and the other references are intact; what made it disappear (prism fallen, removed, hidden) is not visible on the whole image. At the same measurement, MICHIGAN, in the same building as NEBRASKA according to the expert, also loses one of its references (REFPOU22), whose spot disappears in the same way with no visible obstacle: a cause common to both, in the building, is to be looked for; it is not established. At the loss, all the targets jump together in one step: corr_x upward, most on COLJ20, POUJ19, POUJ20 and POUH19, and corr_y upward on COLH19, COLH20, COLJ23 and COLJ24; the jump does not return, it is not a movement. The compensation then runs on the two only references REFH22 and REFP''21 (the corrections of these two references cancel): a more fragile basis, which no longer compensates the camera movement well and makes all the targets move at the slightest deviation of a reference. Very bad sign for the measurement: check the prism of REFCOLH22 on site and restore it.", "review": "2026-11-17"}
{"start": "2026-10-16T20:00Z", "end": "2026-11-01T00:00Z", "family": "Displacement", "description": "Long upward drift of the corr_x of all the targets, strongest on the targets at the top and the right of the image (COLJ20, POUJ20, POUJ19, COLJ19, then COLH19, POUH19, COLH20) and weak in the image on those close to the references (COLH21, COLJ23, COLJ24), although COLJ24, far from the camera, drifts as much as the others in mm; the corr_y of COLH19, POUH19, POUJ20, COLJ19 and COLH20 goes down, that of POUH20 and COLH21 rises; no return at the end of the month. The camera keeps nodding forward as in the first half of the month (tilt rising, pan and rotation turning, scale dropping), and the compensation on two references only renders it poorly, so that the targets drift with it. The camera housing temperature drops from 16 October and the drift follows its jolts: fast rise until 19 October, slower until 24 October, stop and slight backward movement when the temperature rises again from 25 to 28 October, new rise with the cold of 28 and 29 October, slight backward movement when it rises again on 31 October. But the camera was already nodding forward from 3 to 12 October when the temperature was hardly dropping, and it stays more tilted at the end of the month than in the middle at equal temperature: temperature does not explain it alone, link not established. According to the expert, BREITHORN, MICHIGAN and NEBRASKA are in the same building: the cameras of the three stations tilt together, in the same direction and on the same dates (advance until 12 October, stop and slight backward movement from 13 to 16, resumption from the 17th to the end of the month), which points to a cause common to the building rather than a fault of this camera alone. Checked target by target (the raw positions against the overall movement of the targets, and a camera transformation fitted on the other targets): the scene does not move quite as a block, it deforms while the camera tilts. POUH20 moves away the most from the other targets, its neighbor POUH21 hardly at all; then COLH21, and the targets at the edges of the image (COLJ19, COLJ20, COLH19); hence the rise of the corr_y of POUH20 and COLH21. These deviations follow the camera tilt in both directions: POUH20 rises with it on 11 and 12 October, goes back down when it straightens from 13 to 16 October, rises fast with it from 17 to 19 October, then slowly until the end of the month; COLH21 only moves away from 18 October, when the camera exceeds its tilt of the 12th. It is the same movement as that of the camera, not a separate event; at equal tilt, POUH20 stays slightly higher after 17 October than before. Cause not established (the camera moving slightly as it tilts, targets at different distances, or a movement of the structure with the building). Deduced from the curves, the raw positions, the pose and the temperatures; images with nothing clear. For the customer: the camera tilts and the scene deforms with it: a movement of the structure is not established; to be monitored, the camera tilt and the curves of POUH20 and COLH21, which move away the most; restoring a third reference will make the curves reliable again."}
{"start": "2026-10-16T20:00Z", "end": "2026-11-01T00:00Z", "family": "Displacement", "description": "Long upward drift of the corr_x of all the targets, strongest on the targets at the top and the right of the image (COLJ20, POUJ20, POUJ19, COLJ19, then COLH19, POUH19, COLH20) and weak in the image on those close to the references (COLH21, COLJ23, COLJ24), although COLJ24, far from the camera, drifts as much as the others in mm; the corr_y of COLH19, POUH19, POUJ20, COLJ19 and COLH20 goes down, that of POUH20 and COLH21 rises; no return at the end of the month. The camera keeps nodding forward as in the first half of the month (tilt rising, pan and rotation turning, scale dropping), and the compensation on two references only renders it poorly, so that the targets drift with it. The camera housing temperature drops from 16 October and the drift follows its jolts: fast rise until 19 October, slower until 24 October, stop and slight backward movement when the temperature rises again from 25 to 28 October, new rise with the cold of 28 and 29 October, slight backward movement when it rises again on 31 October. But the camera was already nodding forward from 3 to 12 October when the temperature was hardly dropping, and it stays more tilted at the end of the month than in the middle at equal temperature: temperature does not explain it alone, link not established. According to the expert, BREITHORN, MICHIGAN and NEBRASKA are in the same building: the cameras of the three stations tilt together, in the same direction and on the same dates (advance until 12 October, stop and slight backward movement from 13 to 16, resumption from the 17th to the end of the month), which points to a cause common to the building rather than a fault of this camera alone. Checked target by target (the raw positions against the overall movement of the targets, and a camera transformation fitted on the other targets): the scene does not move quite as a block, it deforms while the camera tilts. POUH20 moves away the most from the other targets, its neighbor POUH21 hardly at all; then COLH21, and the targets at the edges of the image (COLJ19, COLJ20, COLH19); hence the rise of the corr_y of POUH20 and COLH21. These deviations follow the camera tilt in both directions: POUH20 rises with it on 11 and 12 October, goes back down when it straightens from 13 to 16 October, rises fast with it from 17 to 19 October, then slowly until the end of the month; COLH21 only moves away from 18 October, when the camera exceeds its tilt of the 12th. It is the same movement as that of the camera, not a separate event; at equal tilt, POUH20 stays slightly higher after 17 October than before. Cause not established (the camera moving slightly as it tilts, targets at different distances, or a movement of the structure with the building). Deduced from the curves, the raw positions, the pose and the temperatures; images with nothing clear. For the customer: the camera tilts and the scene deforms with it: a movement of the structure is not established; to be monitored, the camera tilt and the curves of POUH20 and COLH21, which move away the most; restoring a third reference will make the curves reliable again.", "review": "2026-11-18"}
@@ -1,39 +1,39 @@
{"start": "2026-10-11T05:00Z", "end": "2026-10-11T07:00Z", "family": "No data", "description": "One measurement is missing for all the sensors, references and targets: one point absent on all the curves; there is no image at that hour either. The station is running (metrics present at that hour, normal voltage before and after) and no other station misses this measurement; the cause of the gap is not established (measurement not made or not transmitted). The curves resume at the next measurement without a jump: nothing to do."}
{"start": "2026-10-11T05:00Z", "end": "2026-10-11T07:00Z", "family": "No data", "description": "One measurement is missing for all the sensors, references and targets: one point absent on all the curves; there is no image at that hour either. The station is running (metrics present at that hour, normal voltage before and after) and no other station misses this measurement; the cause of the gap is not established (measurement not made or not transmitted). The curves resume at the next measurement without a jump: nothing to do.", "review": "2026-11-18"}
{"start": "2026-10-11T15:00Z", "end": "2026-10-11T18:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day (11/10). The housing temperature rises a little from the morning until 15:00, fastest between 13:00 and 14:00, where it gains a little. The camera pose follows: the tilt rises a little at 16:00 and comes back at 17:00; the pan rises a little until 17:00 and goes back down until about 20:00. This day, the cycle is weak: only the pan stands out of its noise, from 16:00 to 17:00, and among the targets only PWD_IMP_B07_018_C09 drops markedly; the compensation follows the pose well enough that the other corrected curves hardly show it. The raw positions of all the sensors, references included, move together in the image; the compensation follows it in part: the corr_x of PWD_IMP_B07_018_C09 and PWD_IMP_B07_017_C09 in the centre and on the right drops markedly, that of PWD_RMP_B15_019_C09 in the centre and on the right rises a little. Deduced cause: the camera and its mount move with the housing temperature (pose and temperature go together), the fixed references on the road move with the targets in the image. Normal, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-11T21:00Z", "end": "2026-10-12T06:00Z", "family": "Visibility", "description": "In the evening and through the night of 11 to 12.10, for several hours: the recognition error of many targets rises, several are rejected at times (especially PWD_RMP_B12_019_C09, e06, e09, PWD_RMP_B15_018_C09, PWD_RMP_B16_026_C09, PWD_IMP_B07_017_C09, PWD_IMP_B07_018_C09, PWD_RMP_B12_017_C09 and PWD_RMP_B12_018_C09) and the others fluctuate; just under the threshold, the corr_x of PWD_RMP_B15_020_C09, PWD_IMP_B08_025_C09, e10, e15 and PWD_RMP_B16_026_C09 drops strongly at the worst of it; the references hold, higher up on the road. Worst in the middle of the night, then a gradual return: after the train of 04:00 (labelled apart), PWD_RMP_B15_020_C09 and PWD_IMP_B08_025_C09 are still off their level at 05:00 and back at 06:00. Probable cause: rain or mist (smaller and weaker spots on the 01:00 and 03:00 thumbnails than on a clear night, without any obstacle). The structure does not move: do not trust the curves over the range."}
{"start": "2026-10-11T21:00Z", "end": "2026-10-12T06:00Z", "family": "Visibility", "description": "In the evening and through the night of 11 to 12.10, for several hours: the recognition error of many targets rises, several are rejected at times (especially PWD_RMP_B12_019_C09, e06, e09, PWD_RMP_B15_018_C09, PWD_RMP_B16_026_C09, PWD_IMP_B07_017_C09, PWD_IMP_B07_018_C09, PWD_RMP_B12_017_C09 and PWD_RMP_B12_018_C09) and the others fluctuate; just under the threshold, the corr_x of PWD_RMP_B15_020_C09, PWD_IMP_B08_025_C09, e10, e15 and PWD_RMP_B16_026_C09 drops strongly at the worst of it; the references hold, higher up on the road. Worst in the middle of the night, then a gradual return: after the train of 04:00 (labelled apart), PWD_RMP_B15_020_C09 and PWD_IMP_B08_025_C09 are still off their level at 05:00 and back at 06:00. Probable cause: rain or mist (smaller and weaker spots on the 01:00 and 03:00 thumbnails than on a clear night, without any obstacle). The structure does not move: do not trust the curves over the range.", "review": "2026-11-18"}
{"start": "2026-10-12T03:00Z", "end": "2026-10-12T05:00Z", "family": "Obstruction", "description": "A single measurement: e02, e06, e09, e10, PWD_RMP_B16_026_C09, PWD_RMP_B17_026_C09, PWD_IMP_B08_025_C09, e14, e15, PWD_RMP_B15_020_C09, PWD_IMP_B07_018_C09, PWD_RMP_B15_019_C09, PWD_RMP_B15_018_C09 are rejected and missing from the corrected curves; the references stay intact. Remaining under the threshold, e13, PWD_RMP_B12_018_C09, PWD_IMP_B07_017_C09, PWD_RMP_B12_017_C09, PWD_RMP_B15_017_C09 make a one-measurement jump on corr_x or corr_y, then come back. Cause seen: a freight train, wagon numbers legible, on the 04:00 image. Everything comes back at the next measurement: the structure does not move, point to ignore.", "review": "2026-11-17"}
{"start": "2026-10-12T15:00Z", "end": "2026-10-13T00:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day (12/10). The housing temperature rises markedly from the morning until 19:00, fastest between 15:00 and 16:00, where it gains a little. The camera pose follows: the tilt drops a little at 19:00 and comes back at 20:00; the rotation rises a little at 18:00 and comes back at 19:00; the pan rises markedly until 18:00 and goes back down until about 21:00; the scale rises markedly until 19:00 and only comes back slowly, during the night. This day, the cycle starts late, with the temperature rise around 16:00, and the tilt and the rotation move opposite to the other days, for a single measurement. The raw positions of all the sensors, references included, move together in the image; the compensation follows poorly: the corr_x of PWD_IMP_B07_018_C09, PWD_RMP_B12_018_C09, PWD_IMP_B08_025_C09 and PWD_RMP_B12_017_C09 in the centre and on the right drops markedly, that of PWD_RMP_B15_018_C09, PWD_RMP_B17_026_C09, e06 and PWD_RMP_B15_019_C09 rises markedly; the corr_y moves in the opposite direction, less strongly: it rises for PWD_RMP_B12_017_C09, it drops for PWD_IMP_B07_017_C09, e10 and PWD_RMP_B12_019_C09. The targets do not quite move as one block: against the overall movement, the residual of those that depart from it most, small in the morning, grows markedly during the day. From one measurement to the next, as long as the housing is hot (13:00-22:00), the pose and the curves also fluctuate: the step from one measurement to the next is far larger than at night on the pan, the tilt and the rotation, a little larger on the corr_x of the targets; the recognition error of the targets, however, does not rise (it drops a little). The curves return to their night level around 00:00. Deduced cause: the camera and its mount move with the housing temperature (pose and temperature go together), the fixed references on the road move with the targets in the image. Normal, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-12T16:00Z", "end": "2026-10-12T19:00Z", "family": "Obstruction", "description": "PWD_IMP_B07_016_C09 alone: at times its recognition error jumps almost to the maximum and the measurement is rejected, or, just under the threshold, its corr_x or corr_y makes a one-measurement spike, then comes back; its neighbours do not move. Cause seen on the 17:00 thumbnail: leaves cover the spot, which can no longer be seen; it is the foreground plant, shaken by the wind, which, according to the expert, passes in front of this target. The structure does not move: ignore this target's curve over the range.", "review": "2026-11-17"}
{"start": "2026-10-13T07:00Z", "end": "2026-10-13T20:00Z", "family": "Obstruction", "description": "PWD_IMP_B07_016_C09 alone: at times its recognition error jumps almost to the maximum and the measurement is rejected, or, just under the threshold, its corr_x or corr_y makes a one-measurement spike, then comes back; its neighbours do not move. Cause seen on the 13:00 thumbnail: leaves cover the spot; it is the foreground plant, shaken by the wind, which, according to the expert, passes in front of this target. The structure does not move: ignore this target's curve over the range.", "review": "2026-11-17"}
{"start": "2026-10-13T08:00Z", "end": "2026-10-13T15:00Z", "family": "Visibility", "description": "At night and in the morning, for several hours: the recognition error of many targets rises and many are rejected at times (especially PWD_IMP_B07_017_C09, PWD_RMP_B12_017_C09, PWD_RMP_B12_018_C09, PWD_RMP_B15_018_C09, PWD_RMP_B15_019_C09, e06, e09 and the targets on the left), and the corrected curves of the targets still measured move far beyond their noise: from 09:00 to 12:00 the corr_x of PWD_RMP_B15_020_C09, PWD_IMP_B08_025_C09, PWD_RMP_B16_026_C09, e15 and e14 drops strongly, deepest between 10:00 and 12:00, then comes back; at 12:00 PWD_RMP_B12_017_C09 jumps up on corr_x, PWD_RMP_B12_018_C09 and PWD_RMP_B15_018_C09 on corr_y; at 14:00 the corr_x of e06 and e09 drops for one measurement and the corr_y of e14 jumps up, before the return to normal in late morning. The references hold, higher up on the road. The train of 13:00 and the plant in front of PWD_IMP_B07_016_C09 are labelled apart. Probable cause: rain or mist (smaller and weaker spots on the 11:00 thumbnails, without any obstacle). The structure does not move: do not trust the curves over the range."}
{"start": "2026-10-13T08:00Z", "end": "2026-10-13T15:00Z", "family": "Visibility", "description": "At night and in the morning, for several hours: the recognition error of many targets rises and many are rejected at times (especially PWD_IMP_B07_017_C09, PWD_RMP_B12_017_C09, PWD_RMP_B12_018_C09, PWD_RMP_B15_018_C09, PWD_RMP_B15_019_C09, e06, e09 and the targets on the left), and the corrected curves of the targets still measured move far beyond their noise: from 09:00 to 12:00 the corr_x of PWD_RMP_B15_020_C09, PWD_IMP_B08_025_C09, PWD_RMP_B16_026_C09, e15 and e14 drops strongly, deepest between 10:00 and 12:00, then comes back; at 12:00 PWD_RMP_B12_017_C09 jumps up on corr_x, PWD_RMP_B12_018_C09 and PWD_RMP_B15_018_C09 on corr_y; at 14:00 the corr_x of e06 and e09 drops for one measurement and the corr_y of e14 jumps up, before the return to normal in late morning. The references hold, higher up on the road. The train of 13:00 and the plant in front of PWD_IMP_B07_016_C09 are labelled apart. Probable cause: rain or mist (smaller and weaker spots on the 11:00 thumbnails, without any obstacle). The structure does not move: do not trust the curves over the range.", "review": "2026-11-18"}
{"start": "2026-10-13T12:00Z", "end": "2026-10-13T14:00Z", "family": "Obstruction", "description": "A single measurement: e02, e06, e09, e10, PWD_RMP_B16_026_C09, PWD_RMP_B17_026_C09, PWD_IMP_B08_025_C09, e14, e15, PWD_RMP_B15_020_C09, PWD_IMP_B07_018_C09, PWD_RMP_B15_019_C09, PWD_RMP_B12_018_C09, PWD_RMP_B15_018_C09, PWD_IMP_B07_017_C09, PWD_RMP_B12_017_C09, PWD_IMP_B07_016_C09 are rejected and missing from the corrected curves; the references stay intact. Remaining under the threshold, e13, PWD_RMP_B12_020_C09, PWD_RMP_B12_019_C09 make a one-measurement jump on corr_x or corr_y, then come back. Cause seen: a freight train, wagon numbers legible, on the 13:00 image. Everything comes back at the next measurement: the structure does not move, point to ignore.", "review": "2026-11-17"}
{"start": "2026-10-13T13:00Z", "end": "2026-10-14T06:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day (13/10). The housing temperature rises strongly from the morning until 18:00, fastest between 13:00 and 14:00, where it gains markedly, then falls all night. The camera pose follows: from 14:00 to 16:00, the tilt rises markedly and the rotation drops markedly, then both come back at once at 17:00; the tilt then drops markedly below its morning level at 19:00 and only comes back by 05:00; the pan rises markedly until 17:00, then goes back down below its morning level, lowest around 00:00, and comes back slowly during the night; the scale rises strongly until 20:00 and only comes back slowly, during the night. The raw positions of all the sensors, references included, move together in the image; the compensation follows poorly: the corr_x of PWD_IMP_B07_018_C09, PWD_RMP_B12_018_C09, PWD_IMP_B07_017_C09 and PWD_RMP_B12_017_C09 in the centre and on the right drops strongly, that of e02 and PWD_RMP_B15_018_C09 rises markedly; the corr_y moves in the opposite direction, less strongly: it rises for PWD_RMP_B12_017_C09 and PWD_IMP_B07_017_C09, it drops for PWD_RMP_B12_019_C09, PWD_RMP_B12_018_C09 and PWD_RMP_B12_020_C09. From one measurement to the next, as long as the housing is hot (13:00-22:00), the pose and the curves also fluctuate: the step from one measurement to the next is far larger than at night on the pan, the tilt and the rotation, markedly larger on the corr_x of the targets; the recognition error of the targets, however, does not rise (it drops a little). The curves come back to their night level only in the night, around 05:00, PWD_IMP_B07_018_C09 and PWD_RMP_B12_018_C09 last. Deduced cause: the camera and its mount move with the housing temperature (pose and temperature go together), the fixed references on the road move with the targets in the image. Normal, nothing to do."}
{"start": "2026-10-13T13:00Z", "end": "2026-10-14T06:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day (13/10). The housing temperature rises strongly from the morning until 18:00, fastest between 13:00 and 14:00, where it gains markedly, then falls all night. The camera pose follows: from 14:00 to 16:00, the tilt rises markedly and the rotation drops markedly, then both come back at once at 17:00; the tilt then drops markedly below its morning level at 19:00 and only comes back by 05:00; the pan rises markedly until 17:00, then goes back down below its morning level, lowest around 00:00, and comes back slowly during the night; the scale rises strongly until 20:00 and only comes back slowly, during the night. The raw positions of all the sensors, references included, move together in the image; the compensation follows poorly: the corr_x of PWD_IMP_B07_018_C09, PWD_RMP_B12_018_C09, PWD_IMP_B07_017_C09 and PWD_RMP_B12_017_C09 in the centre and on the right drops strongly, that of e02 and PWD_RMP_B15_018_C09 rises markedly; the corr_y moves in the opposite direction, less strongly: it rises for PWD_RMP_B12_017_C09 and PWD_IMP_B07_017_C09, it drops for PWD_RMP_B12_019_C09, PWD_RMP_B12_018_C09 and PWD_RMP_B12_020_C09. From one measurement to the next, as long as the housing is hot (13:00-22:00), the pose and the curves also fluctuate: the step from one measurement to the next is far larger than at night on the pan, the tilt and the rotation, markedly larger on the corr_x of the targets; the recognition error of the targets, however, does not rise (it drops a little). The curves come back to their night level only in the night, around 05:00, PWD_IMP_B07_018_C09 and PWD_RMP_B12_018_C09 last. Deduced cause: the camera and its mount move with the housing temperature (pose and temperature go together), the fixed references on the road move with the targets in the image. Normal, nothing to do.", "review": "2026-11-18"}
{"start": "2026-10-13T22:00Z", "end": "2026-10-14T00:00Z", "family": "Obstruction", "description": "A single measurement: e02, e06, e09, e10, PWD_RMP_B16_026_C09, PWD_RMP_B17_026_C09, PWD_IMP_B08_025_C09, PWD_RMP_B15_020_C09, PWD_RMP_B15_019_C09, PWD_RMP_B15_018_C09 are rejected and missing from the corrected curves; the references stay intact. Remaining under the threshold, e13, e14, e15, PWD_RMP_B12_020_C09, PWD_RMP_B12_019_C09, PWD_IMP_B07_018_C09, PWD_RMP_B12_018_C09, PWD_IMP_B07_017_C09, PWD_RMP_B12_017_C09 make a one-measurement jump on corr_x or corr_y, then come back. This is not a train: on the 23:00 image, a swarm of flying insects, lit by the floodlight, passes very close to the lens over the left half of the image, as large blurred white spots. Everything comes back at the next measurement: the structure does not move, point to ignore.", "review": "2026-11-17"}
{"start": "2026-10-14T07:00Z", "end": "2026-10-15T02:00Z", "family": "Obstruction", "description": "PWD_IMP_B07_016_C09 alone: at times its recognition error jumps almost to the maximum and the measurement is rejected, or, just under the threshold, its corr_x or corr_y makes a one-measurement spike, then comes back; its neighbours do not move. Cause seen on the 08:00, 19:00 and 23:00 thumbnails: leaves cover the spot, clear at 10:00; it is the foreground plant, shaken by the wind, which, according to the expert, passes in front of this target. The structure does not move: ignore this target's curve over the range.", "review": "2026-11-17"}
{"start": "2026-10-14T11:00Z", "end": "2026-10-14T14:00Z", "family": "Visibility", "description": "At daybreak, one measurement mostly: e06, e09, PWD_RMP_B16_026_C09, PWD_IMP_B07_018_C09, PWD_RMP_B15_018_C09, PWD_IMP_B07_017_C09 are rejected, other targets jump then come back; the references hold. Cause seen on the 12:00 image: the scene is veiled, milky, as under mist. The structure does not move: points to ignore.", "review": "2026-11-17"}
{"start": "2026-10-14T13:00Z", "end": "2026-10-14T23:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day (14/10). The housing temperature rises markedly from the morning until 21:00, fastest between 13:00 and 14:00, where it gains markedly. The camera pose follows: from 13:00 to 14:00, the tilt rises a little and the rotation drops a little; the tilt comes back at 15:00, the rotation at 21:00; the pan rises markedly until 21:00 and goes back down until about 22:00. This day, the cycle is weak and the tilt only stands out of its noise for one measurement; the pan peaks in the evening. The raw positions of all the sensors, references included, move together in the image; the compensation follows poorly: the corr_x of PWD_IMP_B07_018_C09, PWD_RMP_B12_018_C09 and PWD_IMP_B07_017_C09 in the centre and on the right drops markedly, that of e06, PWD_RMP_B15_018_C09, e13 and e02 rises markedly; the corr_y moves in the opposite direction, less strongly: it rises for PWD_IMP_B07_017_C09. The targets do not quite move as one block: against the overall movement, the residual of those that depart from it most, small in the morning, grows a little during the day. The curves return to their night level around 23:00. Deduced cause: the camera and its mount move with the housing temperature (pose and temperature go together), the fixed references on the road move with the targets in the image. Normal, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-15T01:00Z", "end": "2026-10-15T03:00Z", "family": "Obstruction", "description": "A single measurement, at night: e01 is rejected and missing from its corrected curve; remaining under the threshold, e09 makes a one-measurement jump on corr_x and corr_y, e10 and PWD_RMP_B16_026_C09 jump on corr_x beyond the level where they then stay, and the corr_y of the references PWD_REF11_C09, PWD_REF12_C09 and PWD_REF09_C09 jumps a little, then comes back. Cause seen on the 02:00 image: lit flying insects pass very close to the lens, as large blurred pale spots, one over the left group of targets and others near the references; there are none on the 03:00 image. Everything but the step labelled apart comes back at the next measurement: the structure does not move, point to ignore."}
{"start": "2026-10-15T01:00Z", "end": "2026-10-15T04:00Z", "family": "Displacement", "description": "At the 02:00 measurement, at night, PWD_RMP_B16_026_C09 steps up on corr_y, clearly, and on corr_x, a little, and stays at the new level; e10 and e13 shift a little the same way and stay. At the same measurement, the recognition error of e09, e10 and PWD_RMP_B16_026_C09 goes up a level, that of e13 a little, and stays there until the gap of the following night (NIEDERHORN#72). The other targets and the references keep their level. On the night images, a faint haze surrounds the spots of e09, e10 and PWD_RMP_B16_026_C09 at 02:00, 03:00 and 05:00, absent the night before; at 02:00 lit insects fly in front of the lens (labelled apart). After the gap, the same left-edge targets change level again (NIEDERHORN#73). Cause not established: something left close to the lens over this part of the image (an insect, a spider web) is possible; a movement of these targets is not excluded. To check: look at the lens and at these targets, monitor them."}
{"start": "2026-10-15T01:00Z", "end": "2026-10-15T03:00Z", "family": "Obstruction", "description": "A single measurement, at night: e01 is rejected and missing from its corrected curve; remaining under the threshold, e09 makes a one-measurement jump on corr_x and corr_y, e10 and PWD_RMP_B16_026_C09 jump on corr_x beyond the level where they then stay, and the corr_y of the references PWD_REF11_C09, PWD_REF12_C09 and PWD_REF09_C09 jumps a little, then comes back. Cause seen on the 02:00 image: lit flying insects pass very close to the lens, as large blurred pale spots, one over the left group of targets and others near the references; there are none on the 03:00 image. Everything but the step labelled apart comes back at the next measurement: the structure does not move, point to ignore.", "review": "2026-11-18"}
{"start": "2026-10-15T01:00Z", "end": "2026-10-15T04:00Z", "family": "Displacement", "description": "At the 02:00 measurement, at night, PWD_RMP_B16_026_C09 steps up on corr_y, clearly, and on corr_x, a little, and stays at the new level; e10 and e13 shift a little the same way and stay. At the same measurement, the recognition error of e09, e10 and PWD_RMP_B16_026_C09 goes up a level, that of e13 a little, and stays there until the gap of the following night (NIEDERHORN#72). The other targets and the references keep their level. On the night images, a faint haze surrounds the spots of e09, e10 and PWD_RMP_B16_026_C09 at 02:00, 03:00 and 05:00, absent the night before; at 02:00 lit insects fly in front of the lens (labelled apart). After the gap, the same left-edge targets change level again (NIEDERHORN#73). Cause not established: something left close to the lens over this part of the image (an insect, a spider web) is possible; a movement of these targets is not excluded. To check: look at the lens and at these targets, monitor them.", "review": "2026-11-18"}
{"start": "2026-10-15T13:00Z", "end": "2026-10-15T22:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day (15/10). The housing temperature rises a little from the morning until 18:00, fastest between 16:00 and 17:00, where it gains a little. The camera pose follows: from 14:00 to 17:00, the tilt rises a little and the rotation drops a little, then both come back largely at once at 18:00; the pan rises a little until 19:00 and goes back down until about 22:00. This day, the cycle is weak: the housing temperature gains only very little and only PWD_IMP_B07_018_C09 drops markedly; the measurements stop at 22:00 (NIEDERHORN#72). The raw positions of all the sensors, references included, move together in the image; the compensation follows poorly: the corr_x of PWD_IMP_B07_018_C09 in the centre and on the right drops markedly, that of PWD_RMP_B15_018_C09 in the centre and on the right rises a little; the corr_y moves in the opposite direction, less strongly: it rises for PWD_RMP_B15_018_C09 and PWD_IMP_B07_016_C09. The targets do not quite move as one block: against the overall movement, the residual of those that depart from it most, small in the morning, grows a little during the day. From one measurement to the next, as long as the housing is hot (13:00-22:00), the pose and the curves also fluctuate: the step from one measurement to the next is markedly larger than at night on the pan, the tilt and the rotation, a little larger on the corr_x of the targets; the recognition error of the targets, however, does not rise (it drops a little). The curves return to their night level around 22:00. Deduced cause: the camera and its mount move with the housing temperature (pose and temperature go together), the fixed references on the road move with the targets in the image. Normal, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-15T22:00Z", "end": "2026-10-16T11:00Z", "family": "No data", "description": "No measurement for any sensor during the night of 15 to 16.10: all the curves are missing, and there is no image. The station metrics are also missing for a good part of the night, then come back in the early morning before the measurements; the voltage is normal before the gap, with no sign of a power cut. The gap starts at the same hour, around 23:00, on all the stations that were measuring then (LENZSPITZE only has its first measurements in the middle of this night, WILDSTRUBEL is already stopped), and their metrics stop at the same time on most of them; measurements and metrics resume at different hours depending on the station, most of them in late morning. JUNGFRAU, whose metrics continue, accumulates unsent entries all night, sent off in late morning, and its night measurements are nonetheless missing from the data: a common cause outside the stations (transmission or reception of the data), not a station failure; it is not established. On return, several targets on the left resume at another level (next label). The curves are missing over the range; check whether an intervention took place.", "review": "2026-11-17"}
{"start": "2026-10-15T22:00Z", "end": "2026-10-16T12:00Z", "family": "Displacement", "description": "After the gap of the night of 15 to 16.10, the targets on the left edge e06, e09, e10, e13, e15 and PWD_RMP_B16_026_C09 resume at another level: corr_x markedly lower for e06, e09, e10, e13 and PWD_RMP_B16_026_C09, higher for e15, corr_y higher for e09, e10, e13 and e15; they stay there in the following weeks, with their cycle each day. At the same time, the recognition error of e06, e13 and PWD_RMP_B16_026_C09 goes up a level and stays there, e06 close to its threshold. The other targets and the references do not change level; the raw positions of these targets depart from the overall movement and stay offset. On the 14:00 thumbnail of 16.10 the spot of e06 looks split and that of e13 carries an appendage, and on the night images of the following days the spots of this left part look smeared, two neighbours merging, which they did not before 15.10; the night before, at 02:00 on 15.10, a first smaller step of some of these targets came with a faint haze over this part of the image (labelled apart). Cause not established: something close to the lens over the left part of the image (a spider web or a deposit) is possible; a local movement of this part of the tracks or an intervention during the gap is not excluded. To check: look at the lens and at these targets on site, monitor them."}
{"start": "2026-10-16T11:00Z", "end": "2026-10-16T18:00Z", "family": "Visibility", "description": "When measurements resume after the night gap, in the early morning: many targets are rejected at the first measurements (PWD_IMP_B07_017_C09, PWD_IMP_B07_018_C09, the PWD_RMP_B12 row, PWD_RMP_B15_018_C09, PWD_RMP_B15_019_C09, e02, e06, e09), and the corrected curves of the targets still measured move far beyond their noise: at the first two measurements the corr_x of PWD_IMP_B08_025_C09 drops strongly, that of PWD_RMP_B15_020_C09, PWD_RMP_B17_026_C09, PWD_IMP_B08_024_C09 and e14 clearly, and they only come back at 14:00; at 13:00 PWD_RMP_B15_019_C09 jumps up on corr_y and PWD_RMP_B17_026_C09 drops again on corr_x; until the afternoon, PWD_RMP_B16_026_C09 and e10, on the left edge, stay unsettled and jump on corr_x from one measurement to the next, on top of the level change of the left-edge targets labelled apart. The references hold. The trains of 17:00 and 19:00 are labelled apart. Weaker spots on the 12:00 image, without any obstacle: probable cause, a night of rain or mist like the others, not established. The structure does not move: do not trust the curves over the range."}
{"start": "2026-10-16T11:00Z", "end": "2026-10-17T12:00Z", "family": "Thermal displacement", "description": "Weak, short warming then a long cooling, when measurements resume after the night gap (NIEDERHORN#72). The housing temperature rises a little from 12:00 to 15:00, then falls strongly all evening and all night, until 12:00 on 17.10, far lower than on the previous nights. The camera scale rises a little with it until 15:00, then drops steadily all night, far below its level of the previous nights; the pan drops a little until 13:00, then rises steadily all evening and night, markedly; the tilt and the rotation do not move. In the morning the corrected curves show no readable cycle (the disturbance after the gap, NIEDERHORN#74, and the new level of the left-edge targets, NIEDERHORN#73); during the night, the compensation follows the slow drift poorly: the corr_x of PWD_RMP_B12_018_C09 and PWD_RMP_B12_020_C09 rises markedly, that of PWD_IMP_B08_025_C09 and e10 drops; the corr_y of e09, e06 and PWD_RMP_B12_018_C09 rises markedly, that of PWD_RMP_B12_017_C09 drops a little. The drift lasts until the start of the cycle of 17.10 (labelled apart), which brings the pose back; at equal housing temperature the pose is back at the same place. Deduced cause: the camera and its mount move with the housing temperature. Normal, nothing to do."}
{"start": "2026-10-15T22:00Z", "end": "2026-10-16T12:00Z", "family": "Displacement", "description": "After the gap of the night of 15 to 16.10, the targets on the left edge e06, e09, e10, e13, e15 and PWD_RMP_B16_026_C09 resume at another level: corr_x markedly lower for e06, e09, e10, e13 and PWD_RMP_B16_026_C09, higher for e15, corr_y higher for e09, e10, e13 and e15; they stay there in the following weeks, with their cycle each day. At the same time, the recognition error of e06, e13 and PWD_RMP_B16_026_C09 goes up a level and stays there, e06 close to its threshold. The other targets and the references do not change level; the raw positions of these targets depart from the overall movement and stay offset. On the 14:00 thumbnail of 16.10 the spot of e06 looks split and that of e13 carries an appendage, and on the night images of the following days the spots of this left part look smeared, two neighbours merging, which they did not before 15.10; the night before, at 02:00 on 15.10, a first smaller step of some of these targets came with a faint haze over this part of the image (labelled apart). Cause not established: something close to the lens over the left part of the image (a spider web or a deposit) is possible; a local movement of this part of the tracks or an intervention during the gap is not excluded. To check: look at the lens and at these targets on site, monitor them.", "review": "2026-11-18"}
{"start": "2026-10-16T11:00Z", "end": "2026-10-16T18:00Z", "family": "Visibility", "description": "When measurements resume after the night gap, in the early morning: many targets are rejected at the first measurements (PWD_IMP_B07_017_C09, PWD_IMP_B07_018_C09, the PWD_RMP_B12 row, PWD_RMP_B15_018_C09, PWD_RMP_B15_019_C09, e02, e06, e09), and the corrected curves of the targets still measured move far beyond their noise: at the first two measurements the corr_x of PWD_IMP_B08_025_C09 drops strongly, that of PWD_RMP_B15_020_C09, PWD_RMP_B17_026_C09, PWD_IMP_B08_024_C09 and e14 clearly, and they only come back at 14:00; at 13:00 PWD_RMP_B15_019_C09 jumps up on corr_y and PWD_RMP_B17_026_C09 drops again on corr_x; until the afternoon, PWD_RMP_B16_026_C09 and e10, on the left edge, stay unsettled and jump on corr_x from one measurement to the next, on top of the level change of the left-edge targets labelled apart. The references hold. The trains of 17:00 and 19:00 are labelled apart. Weaker spots on the 12:00 image, without any obstacle: probable cause, a night of rain or mist like the others, not established. The structure does not move: do not trust the curves over the range.", "review": "2026-11-18"}
{"start": "2026-10-16T11:00Z", "end": "2026-10-17T12:00Z", "family": "Thermal displacement", "description": "Weak, short warming then a long cooling, when measurements resume after the night gap (NIEDERHORN#72). The housing temperature rises a little from 12:00 to 15:00, then falls strongly all evening and all night, until 12:00 on 17.10, far lower than on the previous nights. The camera scale rises a little with it until 15:00, then drops steadily all night, far below its level of the previous nights; the pan drops a little until 13:00, then rises steadily all evening and night, markedly; the tilt and the rotation do not move. In the morning the corrected curves show no readable cycle (the disturbance after the gap, NIEDERHORN#74, and the new level of the left-edge targets, NIEDERHORN#73); during the night, the compensation follows the slow drift poorly: the corr_x of PWD_RMP_B12_018_C09 and PWD_RMP_B12_020_C09 rises markedly, that of PWD_IMP_B08_025_C09 and e10 drops; the corr_y of e09, e06 and PWD_RMP_B12_018_C09 rises markedly, that of PWD_RMP_B12_017_C09 drops a little. The drift lasts until the start of the cycle of 17.10 (labelled apart), which brings the pose back; at equal housing temperature the pose is back at the same place. Deduced cause: the camera and its mount move with the housing temperature. Normal, nothing to do.", "review": "2026-11-18"}
{"start": "2026-10-16T14:00Z", "end": "2026-10-17T01:00Z", "family": "Obstruction", "description": "PWD_IMP_B07_016_C09 alone: at times its recognition error jumps almost to the maximum and the measurement is rejected, or, just under the threshold, its corr_x or corr_y makes a one-measurement spike, then comes back; its neighbours do not move. Cause seen on the 15:00 thumbnail: leaves cover the spot; it is the foreground plant, shaken by the wind, which, according to the expert, passes in front of this target. The structure does not move: ignore this target's curve over the range.", "review": "2026-11-17"}
{"start": "2026-10-16T16:00Z", "end": "2026-10-16T18:00Z", "family": "Obstruction", "description": "A single measurement: e02, e06, e09, PWD_IMP_B07_016_C09 are rejected and missing from the corrected curves; the references stay intact. Remaining under the threshold, PWD_RMP_B17_026_C09 makes a one-measurement jump on corr_x or corr_y, then comes back. Cause seen: a double-decker passenger train, motion blur, on the 17:00 image. Everything comes back at the next measurement: the structure does not move, point to ignore.", "review": "2026-11-17"}
{"start": "2026-10-16T18:00Z", "end": "2026-10-16T20:00Z", "family": "Obstruction", "description": "A single measurement: e02, e06, e09 are rejected and missing from the corrected curves; the references stay intact. Remaining under the threshold, PWD_RMP_B16_026_C09, PWD_RMP_B17_026_C09 make a one-measurement jump on corr_x or corr_y, then come back. Cause seen: a passenger train on the far track, on the 19:00 image. Everything comes back at the next measurement: the structure does not move, point to ignore.", "review": "2026-11-17"}
{"start": "2026-10-17T12:00Z", "end": "2026-10-17T16:00Z", "family": "Visibility", "description": "At sunrise, over a few measurements: the recognition error of the references PWD_REF08_C09 and PWD_REF09_C09 rises markedly from 12:00, that of PWD_REF10_C09 and PWD_REF11_C09 a little at 13:00, without rejection, and only comes back slowly over the morning; the compensation is slightly disturbed and the corr_x, corr_y of many targets jump or fluctuate; e09 and e02, on the left, are rejected at 13:00. Cause seen on the image of 17.10 at 13:00: the rising sun enters the field just above the road of the references, with halo and rays across the upper part of the image; it comes back at the same hours on clear days. The structure does not move: do not trust the curves on these measurements."}
{"start": "2026-10-17T12:00Z", "end": "2026-10-17T16:00Z", "family": "Visibility", "description": "At sunrise, over a few measurements: the recognition error of the references PWD_REF08_C09 and PWD_REF09_C09 rises markedly from 12:00, that of PWD_REF10_C09 and PWD_REF11_C09 a little at 13:00, without rejection, and only comes back slowly over the morning; the compensation is slightly disturbed and the corr_x, corr_y of many targets jump or fluctuate; e09 and e02, on the left, are rejected at 13:00. Cause seen on the image of 17.10 at 13:00: the rising sun enters the field just above the road of the references, with halo and rays across the upper part of the image; it comes back at the same hours on clear days. The structure does not move: do not trust the curves on these measurements.", "review": "2026-11-18"}
{"start": "2026-10-17T12:00Z", "end": "2026-10-18T00:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day (17/10). The housing temperature rises strongly from the morning until 19:00, fastest between 12:00 and 13:00, where it gains markedly. The camera pose follows: from 13:00 to 16:00, the tilt rises strongly and the rotation drops strongly, then both come back at once at 17:00; the pan rises strongly until 17:00 and goes back down until about 21:00; the scale rises strongly until 19:00 and only comes back slowly, during the night. The raw positions of all the sensors, references included, move together in the image; the compensation follows poorly: the corr_x of PWD_RMP_B12_018_C09, PWD_IMP_B07_018_C09, PWD_RMP_B12_017_C09 and PWD_IMP_B07_017_C09 in the centre and on the right drops strongly, that of e02, e10, e06 and e09 on the left of the image rises markedly; the corr_y moves in the opposite direction, less strongly: it rises for PWD_RMP_B12_017_C09, PWD_IMP_B07_017_C09 and PWD_RMP_B15_018_C09, it drops for e02, e09 and e15. The targets do not quite move as one block: against the overall movement, the residual of those that depart from it most, small in the morning, grows markedly during the day. From one measurement to the next, as long as the housing is hot (13:00-22:00), the pose and the curves also fluctuate: the step from one measurement to the next is much larger than at night on the pan, the tilt and the rotation, much larger on the corr_x of the targets; the recognition error of the targets, however, does not rise (it drops a little). The curves return to their night level around 23:00. Deduced cause: the camera and its mount move with the housing temperature (pose and temperature go together), the fixed references on the road move with the targets in the image. Normal, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-18T12:00Z", "end": "2026-10-18T15:00Z", "family": "Visibility", "description": "At sunrise, over a few measurements: the recognition error of the reference PWD_REF09_C09 jumps at 12:00, those of PWD_REF08_C09, PWD_REF10_C09 and PWD_REF11_C09 rise markedly at 13:00 and are still above their level at 14:00, without rejection; the compensation is slightly disturbed and the corr_x, corr_y of many targets jump or fluctuate, the references PWD_REF11_C09 and PWD_REF12_C09 moving apart on corr_x at 13:00 and 14:00; e06 and e09, on the left, are rejected at 13:00. Cause seen on the image of 18.10 at 13:00: the rising sun enters the field just above the road of the references, with halo and rays across the upper part of the image; it comes back at the same hours on clear days. The structure does not move: do not trust the curves on these measurements."}
{"start": "2026-10-18T12:00Z", "end": "2026-10-18T15:00Z", "family": "Visibility", "description": "At sunrise, over a few measurements: the recognition error of the reference PWD_REF09_C09 jumps at 12:00, those of PWD_REF08_C09, PWD_REF10_C09 and PWD_REF11_C09 rise markedly at 13:00 and are still above their level at 14:00, without rejection; the compensation is slightly disturbed and the corr_x, corr_y of many targets jump or fluctuate, the references PWD_REF11_C09 and PWD_REF12_C09 moving apart on corr_x at 13:00 and 14:00; e06 and e09, on the left, are rejected at 13:00. Cause seen on the image of 18.10 at 13:00: the rising sun enters the field just above the road of the references, with halo and rays across the upper part of the image; it comes back at the same hours on clear days. The structure does not move: do not trust the curves on these measurements.", "review": "2026-11-18"}
{"start": "2026-10-18T12:00Z", "end": "2026-10-19T00:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day (18/10). The housing temperature rises strongly from the morning until 16:00, fastest between 12:00 and 13:00, where it gains markedly. The camera pose follows: from 13:00 to 15:00, the tilt rises strongly and the rotation drops strongly, then both come back at once at 17:00; the pan rises markedly until 17:00 and goes back down until about 19:00; the scale rises strongly until 19:00 and only comes back slowly, during the night. The raw positions of all the sensors, references included, move together in the image; the compensation follows poorly: the corr_x of PWD_IMP_B07_018_C09, PWD_RMP_B12_018_C09, PWD_IMP_B07_017_C09 and PWD_RMP_B12_017_C09 in the centre and on the right drops strongly, that of e02, e06, PWD_RMP_B17_026_C09 and PWD_RMP_B15_018_C09 rises markedly; the corr_y moves in the opposite direction, less strongly: it rises for PWD_RMP_B12_017_C09, PWD_IMP_B07_017_C09 and PWD_RMP_B15_018_C09, it drops for e02, e09 and e15. The targets do not quite move as one block: against the overall movement, the residual of those that depart from it most, small in the morning, grows strongly during the day. From one measurement to the next, as long as the housing is hot (13:00-22:00), the pose and the curves also fluctuate: the step from one measurement to the next is far larger than at night on the pan, the tilt and the rotation, much larger on the corr_x of the targets; the recognition error of the targets, however, does not rise (it drops a little). The curves return to their night level around 23:00. Deduced cause: the camera and its mount move with the housing temperature (pose and temperature go together), the fixed references on the road move with the targets in the image. Normal, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-19T05:00Z", "end": "2026-10-19T22:00Z", "family": "Obstruction", "description": "PWD_IMP_B07_016_C09 alone: at times its recognition error jumps almost to the maximum and the measurement is rejected, or, just under the threshold, its corr_x or corr_y makes a one-measurement spike, then comes back; its neighbours do not move. Cause seen on the 13:00 and 15:00 thumbnails: the tips of leaves touch the spot; it is the foreground plant, shaken by the wind, which, according to the expert, passes in front of this target. The structure does not move: ignore this target's curve over the range.", "review": "2026-11-17"}
{"start": "2026-10-19T09:00Z", "end": "2026-10-19T11:00Z", "family": "No data", "description": "One measurement is missing for all the sensors, references and targets: one point absent on all the curves. The station metrics are also missing at that hour, and there is no image; normal voltage before and after. The curves resume at the next measurement without a jump. The same gap falls at the same moment on the other stations measuring at that time (CLARIDEN, FLORIDA, JUNGFRAU, LENZSPITZE, NORDEND, SNCF01): a common cause outside the station (transmission or reception of the data), not a station failure; it is not established. The curves are missing over the range; nothing to do on the station.", "review": "2026-11-17"}
{"start": "2026-10-19T11:00Z", "end": "2026-10-19T15:00Z", "family": "Visibility", "description": "At sunrise, over a few measurements: the recognition error of the reference PWD_REF09_C09 jumps at 12:00, those of PWD_REF08_C09, PWD_REF10_C09 and PWD_REF11_C09 rise markedly at 13:00 and are still above their level at 14:00, without rejection; the compensation is disturbed: at 12:00 the corr_x of most targets on the left of the image drops together for one measurement, then the corr_x, corr_y of many targets jump or fluctuate; e06, on the left, is rejected at 13:00 and 14:00, e09 at 13:00. Cause seen on the image of 19.10 at 13:00: the rising sun enters the field just above the road of the references, with halo and rays across the upper part of the image; it comes back at the same hours on clear days. The structure does not move: do not trust the curves on these measurements."}
{"start": "2026-10-19T11:00Z", "end": "2026-10-19T15:00Z", "family": "Visibility", "description": "At sunrise, over a few measurements: the recognition error of the reference PWD_REF09_C09 jumps at 12:00, those of PWD_REF08_C09, PWD_REF10_C09 and PWD_REF11_C09 rise markedly at 13:00 and are still above their level at 14:00, without rejection; the compensation is disturbed: at 12:00 the corr_x of most targets on the left of the image drops together for one measurement, then the corr_x, corr_y of many targets jump or fluctuate; e06, on the left, is rejected at 13:00 and 14:00, e09 at 13:00. Cause seen on the image of 19.10 at 13:00: the rising sun enters the field just above the road of the references, with halo and rays across the upper part of the image; it comes back at the same hours on clear days. The structure does not move: do not trust the curves on these measurements.", "review": "2026-11-18"}
{"start": "2026-10-19T11:00Z", "end": "2026-10-20T00:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day (19/10). The housing temperature rises strongly from the morning until 19:00, fastest between 13:00 and 14:00, where it gains markedly. The camera pose follows: from 12:00 to 16:00, the tilt rises strongly and the rotation drops strongly, then both come back at once at 17:00; the pan rises markedly until 17:00 and goes back down until about 19:00; the scale rises strongly until 19:00 and only comes back slowly, during the night. The raw positions of all the sensors, references included, move together in the image; the compensation follows poorly: the corr_x of PWD_IMP_B07_018_C09, PWD_RMP_B12_018_C09, PWD_IMP_B07_017_C09 and PWD_RMP_B12_017_C09 in the centre and on the right drops strongly, that of e02, e06, PWD_RMP_B17_026_C09 and PWD_RMP_B15_018_C09 rises markedly; the corr_y moves in the opposite direction, less strongly: it rises for PWD_RMP_B12_017_C09, PWD_RMP_B15_018_C09 and PWD_IMP_B07_017_C09, it drops for PWD_RMP_B12_019_C09, e15 and e10. The targets do not quite move as one block: against the overall movement, the residual of those that depart from it most, small in the morning, grows strongly during the day. From one measurement to the next, as long as the housing is hot (13:00-22:00), the pose and the curves also fluctuate: the step from one measurement to the next is far larger than at night on the pan, the tilt and the rotation, much larger on the corr_x of the targets; the recognition error of the targets, however, does not rise (it drops a little). The curves return to their night level around 23:00. Deduced cause: the camera and its mount move with the housing temperature (pose and temperature go together), the fixed references on the road move with the targets in the image. Normal, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-19T20:00Z", "end": "2026-10-19T22:00Z", "family": "No data", "description": "One measurement is missing for all the sensors, references and targets: one point absent on all the curves. The station metrics are also missing at that hour, and there is no image; normal voltage before and after. The curves resume at the next measurement without a jump. The same gap falls at the same moment on the other stations measuring at that time (CLARIDEN, FLORIDA, JUNGFRAU, LENZSPITZE, NORDEND, SNCF01): a common cause outside the station (transmission or reception of the data), not a station failure; it is not established. The curves are missing over the range; nothing to do on the station. The hourly metrics of BREITHORN, MICHIGAN and NEBRASKA are also missing at 21:00.", "review": "2026-11-17"}
{"start": "2026-10-20T05:00Z", "end": "2026-10-20T13:00Z", "family": "Obstruction", "description": "PWD_IMP_B07_016_C09 alone: at times its recognition error jumps almost to the maximum and the measurement is rejected, or, just under the threshold, its corr_x or corr_y makes a one-measurement spike, then comes back; its neighbours do not move. Cause: the foreground plant, shaken by the wind, passes in front of the target; on the 07:00 and 09:00 thumbnails, the tip of a leaf touches the spot, which looks cut off. The structure does not move: ignore this target's curve over the range.", "review": "2026-11-17"}
{"start": "2026-10-20T11:00Z", "end": "2026-10-20T13:00Z", "family": "Obstruction", "description": "A single measurement: e02, e06, e09, e10, PWD_RMP_B16_026_C09, PWD_RMP_B17_026_C09, PWD_IMP_B08_025_C09, e14, PWD_RMP_B15_019_C09, PWD_IMP_B07_017_C09, PWD_IMP_B07_016_C09 are rejected and missing from the corrected curves; the references stay intact. Remaining under the threshold, e15, PWD_RMP_B12_020_C09, PWD_RMP_B15_020_C09, PWD_RMP_B12_019_C09, PWD_RMP_B12_018_C09, PWD_RMP_B15_018_C09 make a one-measurement jump on corr_x or corr_y, then come back. Cause seen: a dark band cutting across the tracks on the 12:00 image, a train in the dim dawn light. Everything comes back at the next measurement: the structure does not move, point to ignore.", "review": "2026-11-17"}
{"start": "2026-10-20T12:00Z", "end": "2026-10-20T15:00Z", "family": "Visibility", "description": "At sunrise, over a few measurements: the recognition error of the references PWD_REF10_C09 and PWD_REF11_C09 rises markedly at 13:00, that of PWD_REF08_C09 a little, and is still above its level at 14:00, without rejection; the compensation is slightly disturbed and the corr_x, corr_y of many targets jump or fluctuate, the references PWD_REF11_C09 and PWD_REF12_C09 moving apart on corr_x at 13:00 and 14:00; e06 and e09, on the left, are rejected at 13:00 (at 12:00 they are hidden by the train labelled apart). Cause seen on the image of 20.10 at 13:00: the rising sun enters the field just above the road of the references, with halo and rays across the upper part of the image; it comes back at the same hours on clear days. The structure does not move: do not trust the curves on these measurements."}
{"start": "2026-10-20T12:00Z", "end": "2026-10-20T15:00Z", "family": "Visibility", "description": "At sunrise, over a few measurements: the recognition error of the references PWD_REF10_C09 and PWD_REF11_C09 rises markedly at 13:00, that of PWD_REF08_C09 a little, and is still above its level at 14:00, without rejection; the compensation is slightly disturbed and the corr_x, corr_y of many targets jump or fluctuate, the references PWD_REF11_C09 and PWD_REF12_C09 moving apart on corr_x at 13:00 and 14:00; e06 and e09, on the left, are rejected at 13:00 (at 12:00 they are hidden by the train labelled apart). Cause seen on the image of 20.10 at 13:00: the rising sun enters the field just above the road of the references, with halo and rays across the upper part of the image; it comes back at the same hours on clear days. The structure does not move: do not trust the curves on these measurements.", "review": "2026-11-18"}
{"start": "2026-10-20T12:00Z", "end": "2026-10-20T23:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day (20/10). The housing temperature rises strongly from the morning until 15:00, fastest between 13:00 and 14:00, where it gains markedly. The camera pose follows: from 13:00 to 15:00, the tilt rises strongly and the rotation drops strongly, then both come back at once at 17:00; the pan rises strongly until 17:00 and goes back down until about 22:00; the scale rises markedly until 19:00 then comes back in the evening. The raw positions of all the sensors, references included, move together in the image; the compensation follows poorly: the corr_x of PWD_IMP_B07_018_C09, PWD_RMP_B12_018_C09, PWD_IMP_B08_025_C09 and PWD_IMP_B07_017_C09 in the centre and on the right drops strongly, that of e06, e02, e13 and PWD_RMP_B17_026_C09 on the left of the image rises markedly; the corr_y moves in the opposite direction, less strongly: it rises for PWD_RMP_B12_017_C09, PWD_IMP_B07_017_C09 and PWD_IMP_B08_025_C09, it drops for e15, e02 and e09. The targets do not quite move as one block: against the overall movement, the residual of those that depart from it most, small in the morning, grows strongly during the day. From one measurement to the next, as long as the housing is hot (13:00-22:00), the pose and the curves also fluctuate: the step from one measurement to the next is much larger than at night on the pan, the tilt and the rotation, markedly larger on the corr_x of the targets; the recognition error of the targets, however, does not rise (it drops a little). The curves return to their night level around 23:00. Deduced cause: the camera and its mount move with the housing temperature (pose and temperature go together), the fixed references on the road move with the targets in the image. Normal, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-20T16:00Z", "end": "2026-10-20T18:00Z", "family": "Obstruction", "description": "A single measurement: e02, e06, e09 are rejected and missing from the corrected curves; the references stay intact. Remaining under the threshold, PWD_RMP_B17_026_C09, e15 make a one-measurement jump on corr_x or corr_y, then come back. Cause seen: a double-decker passenger train on the far track, on the 17:00 image. Everything comes back at the next measurement: the structure does not move, point to ignore.", "review": "2026-11-17"}
{"start": "2026-10-20T20:00Z", "end": "2026-10-20T22:00Z", "family": "No data", "description": "One measurement is missing for all the sensors, references and targets: one point absent on all the curves. The camera took the 21:00 image and the metrics are present: the measurement was not made or not transmitted. The measurements of CLARIDEN are also missing at that hour, and those of no other station: a common cause is possible, not established. The curves resume at the next measurement without a jump: nothing to do.", "review": "2026-11-17"}
@@ -17,12 +17,12 @@
{"start": "2026-08-19T20:15Z", "end": "2026-08-20T03:45Z", "family": "Visibility", "description": "Cobweb night: on the 22:00 and 02:00 images, very noisy, a lit blurred band crosses the top of the group of targets and blurred discs are at the bottom left. CTR01 is rejected all night, PR07 for a few measurements; the corr_x of PR07 jumps at the start of the night and that of PR08 departs in the second half of the night. The range is cut by measurement gaps (labelled separately). The structure does not move: do not trust these curves over the range.", "review": "2026-11-17"}
{"start": "2026-08-19T20:30Z", "end": "2026-08-19T21:00Z", "family": "No data", "description": "One measurement is missing for all the sensors, just after the resumption from the afternoon gap: all the curves have a gap. The image is missing too, but the station synchronised at that instant (last_sync) and its voltage is normal. No other station has data on that date to compare; cause not established. The curves resume at the next measurement: nothing to do.", "review": "2026-11-17"}
{"start": "2026-08-20T00:30Z", "end": "2026-08-20T01:00Z", "family": "No data", "description": "One measurement is missing for all the sensors, at night: all the curves have a gap. The image of that instant is missing too, but the station synchronised at that instant (last_sync) and its voltage is normal. No other station has data on that date to compare; cause not established. A gap of one or two measurements comes back around the same hour on many nights of the range. The curves resume at the next measurement: nothing to do.", "review": "2026-11-17"}
{"start": "2026-08-20T03:45Z", "end": "2026-08-20T06:15Z", "family": "No data", "description": "No measurement at the end of the night, for a few hours: all the curves are missing from 04:00 to 06:00. The images and the system metrics are missing too from 04:00; the voltage is normal before and after. The image and a synchronisation (last_sync) come back at 06:00, one acquisition before the first measurement (06:15): at that instant the station is running and only the measurement is missing. No other station has data on that date to compare; cause not established. The curves resume without any offset of their own (the pose started with the morning, in the thermal cycle labelled separately): nothing to do."}
{"start": "2026-08-20T03:45Z", "end": "2026-08-20T06:15Z", "family": "No data", "description": "No measurement at the end of the night, for a few hours: all the curves are missing from 04:00 to 06:00. The images and the system metrics are missing too from 04:00; the voltage is normal before and after. The image and a synchronisation (last_sync) come back at 06:00, one acquisition before the first measurement (06:15): at that instant the station is running and only the measurement is missing. No other station has data on that date to compare; cause not established. The curves resume without any offset of their own (the pose started with the morning, in the thermal cycle labelled separately): nothing to do.", "review": "2026-11-18"}
{"start": "2026-08-20T06:15Z", "end": "2026-08-21T05:15Z", "family": "Thermal displacement", "description": "Thermal cycle of the camera, poorly compensated. The start of the morning falls in a measurement gap (labelled separately): when measurements resume, the pose has already moved (tilt up, pan down). The raw positions of all the targets and references move together; the compensation does not erase everything, the corr_x of PR18 and PR16 drops a little, then comes back in the afternoon; the camera then comes back slowly, in the evening and all night (the pan rises, the corr_x of PR18 too), until the start of the next morning. Deduced cause: the pose follows the housing temperature, and the rock face of the quarry cannot move with the temperature. This is not a movement of the structure: nothing to do.", "review": "2026-11-17"}
{"start": "2026-08-20T08:00Z", "end": "2026-08-20T09:00Z", "family": "No data", "description": "Three measurements in a row are missing for all the sensors in the morning, the images too, with no synchronisation at those instants; the hourly metrics are there and the voltage is normal. No other station has data on that date to compare; cause not established. The curves then resume: nothing to do.", "review": "2026-11-17"}
{"start": "2026-08-20T16:15Z", "end": "2026-08-20T17:15Z", "family": "Visibility", "description": "The sun reaches the wall in late afternoon (16:15, 16:30, 16:45 thumbnails): PR07 disappears and is rejected for one measurement, the corr_x of PR14, PR15 and PR16 jumps for the time of this measurement, PR05 and PR08 a little at the next, then everything comes back. Points to ignore, nothing to do.", "review": "2026-11-17"}
{"start": "2026-08-21T00:30Z", "end": "2026-08-21T01:15Z", "family": "No data", "description": "Two measurements in a row are missing for all the sensors, at night: all the curves have a gap, the images are missing too; the station synchronised at the start of the gap (last_sync) and its voltage is normal. No other station has data on that date to compare; cause not established. A gap of one or two measurements comes back around the same hour on many nights of the range. The curves then resume: nothing to do.", "review": "2026-11-17"}
{"start": "2026-08-21T05:15Z", "end": "2026-08-22T06:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the camera, poorly compensated. In the morning, when the housing heats up, the camera turns all at once (tilt rising, pan dropping, scale changing); the raw positions of all the targets and references move together. The compensation does not erase everything: the corr_x of PR18 drops markedly, the corr_y of PR18 rises, then the curves come back in the afternoon; the camera then comes back slowly, in the evening, then only very little at night, until the start of the next morning. In the evening and at night, the cobweb (labelled separately) makes its own jumps. Deduced cause: the pose follows the housing temperature, and the rock face of the quarry cannot move with the temperature. This is not a movement of the structure: nothing to do.", "review": "2026-11-17"}
{"start": "2026-08-21T15:45Z", "end": "2026-08-22T07:30Z", "family": "Visibility", "description": "A cobweb settles in front of the lens in late afternoon: blurred bands are already visible by day (16:45 image), then at night as wide lit bands covering a large part of the scene (18:15, 19:15, 20:30, 03:00); the image becomes sharp again in the morning (07:30). PR07 is rejected from 16:00, CTR01 all night; at dusk, most of the targets are rejected at the same time and the corrected curves of the others jump in both directions; PR08 stays offset on corr_x until the morning. The structure does not move: do not trust the curves over the range, nothing to do.", "review": "2026-11-17"}
{"start": "2026-08-22T06:00Z", "end": "2026-08-23T05:15Z", "family": "Thermal displacement", "description": "Thermal cycle of the camera, poorly compensated. In the morning, when the housing heats up, the camera turns all at once (tilt rising, pan dropping, scale changing); the raw positions of all the targets and references move together. The compensation does not erase everything: the corr_x of PR18, PR14, PR16 and PR15 drops markedly, the corr_y of PR18 rises, then the curves come back in the afternoon; the camera then comes back slowly, in the evening and all night (the pan rises again), until the start of the next morning. The following night is the coldest of the batch: as the housing temperature keeps falling, the camera keeps turning (scale dropping, rotation and pan rising), the registration error rises, and the reference CTR04 slides a little downward against the targets while CTR02 slides the other way; through the compensation, the corr_y of most targets rises a little and stays up from midnight to the end of the night (PR15, PR07, PR10, PR06, PR14, PR16 above all, and the reference CTR02, while CTR03 goes down), then comes back as the housing warms up in the next morning. The targets do not move relative to each other, their error_value stays at its level, and the reference thumbnails show sharp spots, although lit cobweb threads cross the image all night (20:00 and 03:00 images). Deduced cause: the pose follows the housing temperature, and the rock face of the quarry cannot move with the temperature. This is not a movement of the structure: nothing to do."}
{"start": "2026-08-22T06:00Z", "end": "2026-08-23T05:15Z", "family": "Thermal displacement", "description": "Thermal cycle of the camera, poorly compensated. In the morning, when the housing heats up, the camera turns all at once (tilt rising, pan dropping, scale changing); the raw positions of all the targets and references move together. The compensation does not erase everything: the corr_x of PR18, PR14, PR16 and PR15 drops markedly, the corr_y of PR18 rises, then the curves come back in the afternoon; the camera then comes back slowly, in the evening and all night (the pan rises again), until the start of the next morning. The following night is the coldest of the batch: as the housing temperature keeps falling, the camera keeps turning (scale dropping, rotation and pan rising), the registration error rises, and the reference CTR04 slides a little downward against the targets while CTR02 slides the other way; through the compensation, the corr_y of most targets rises a little and stays up from midnight to the end of the night (PR15, PR07, PR10, PR06, PR14, PR16 above all, and the reference CTR02, while CTR03 goes down), then comes back as the housing warms up in the next morning. The targets do not move relative to each other, their error_value stays at its level, and the reference thumbnails show sharp spots, although lit cobweb threads cross the image all night (20:00 and 03:00 images). Deduced cause: the pose follows the housing temperature, and the rock face of the quarry cannot move with the temperature. This is not a movement of the structure: nothing to do.", "review": "2026-11-18"}
{"start": "2026-08-22T16:30Z", "end": "2026-08-22T17:00Z", "family": "No data", "description": "One measurement is missing for all the sensors in late afternoon; the image of that instant exists. The system metrics are missing for several hours from that hour, then the entries waiting to be sent (DB_not_uploaded) accumulate until the next morning before being sent: the station is running, the sending of its data is hindered. According to the data documentation, FLORIDA and MISSISSIPPI also have a gap on the same day around the same hour (their data for this date are not in the folder): a common cause outside the station (transmission or reception of the data), not a station failure; it is not established. The curves resume at the next measurement: nothing to do on the station.", "review": "2026-11-17"}
@@ -1,5 +1,5 @@
{"start": "2026-09-17T05:45Z", "end": "2026-09-18T06:30Z", "family": "Thermal displacement", "description": "Thermal cycle of the camera, poorly compensated. In the morning, when the housing heats up, the camera turns gradually (tilt rising, pan dropping, scale changing); the raw positions of all the targets and references move together. The compensation does not erase everything: the corr_x of PR18, PR16 and PR15 drops a little, the corr_y of PR18 hardly moves, then the curves come back in the afternoon; the camera then comes back slowly, in the evening, then only very little at night, until the start of the next morning. Deduced cause: the pose follows the housing temperature, and the rock face of the quarry cannot move with the temperature. This is not a movement of the structure: nothing to do.", "review": "2026-11-17"}
{"start": "2026-09-17T14:30Z", "end": "2026-09-17T15:00Z", "family": "Visibility", "description": "CTR01 (local reference, treated as a target) makes a clear corr_x jump for one measurement in the afternoon and comes back at the next, without being rejected: its error_value rises just under the threshold for that measurement alone, so its point stays on the curve, wrong; its corr_y does not move. Seen on the thumbnail of 14:45: the rock around the target is in full sun, as bright as the spot, which drowns in it; at 14:00 the rock is less lit and at 15:15 it is in shade, the spot sharp. Same hour and same cause as the other sunny afternoons, where CTR01 is rejected instead and its curve is only missing. The other targets show nothing. The structure does not move: ignore this point of CTR01."}
{"start": "2026-09-17T14:30Z", "end": "2026-09-17T15:00Z", "family": "Visibility", "description": "CTR01 (local reference, treated as a target) makes a clear corr_x jump for one measurement in the afternoon and comes back at the next, without being rejected: its error_value rises just under the threshold for that measurement alone, so its point stays on the curve, wrong; its corr_y does not move. Seen on the thumbnail of 14:45: the rock around the target is in full sun, as bright as the spot, which drowns in it; at 14:00 the rock is less lit and at 15:15 it is in shade, the spot sharp. Same hour and same cause as the other sunny afternoons, where CTR01 is rejected instead and its curve is only missing. The other targets show nothing. The structure does not move: ignore this point of CTR01.", "review": "2026-11-18"}
{"start": "2026-09-17T20:00Z", "end": "2026-09-17T22:45Z", "family": "Obstruction", "description": "At night, PR07 is rejected at times (its curve is missing) and makes one-measurement jumps; PR14, PR15 and PR16 also depart for one or two measurements. A cobweb lit by the infrared crosses the field of the targets (23:00 image), the spot of PR07 is tiny on the 22:00 one. Deduced cause: the cobweb seen on the field of the targets. The structure does not move: ignore these points.", "review": "2026-11-17"}
{"start": "2026-09-18T06:30Z", "end": "2026-09-19T06:15Z", "family": "Thermal displacement", "description": "Thermal cycle of the camera, poorly compensated. In the morning, when the housing heats up, the camera turns gradually (tilt rising, pan dropping, scale changing); the raw positions of all the targets and references move together. The compensation does not erase everything: the corr_x of PR18, PR16, PR15 and PR14 drops markedly, the corr_y of PR18 rises, then the curves come back in the afternoon; the camera then comes back slowly, in the evening, then only very little at night, until the start of the next morning. Deduced cause: the pose follows the housing temperature, and the rock face of the quarry cannot move with the temperature. This is not a movement of the structure: nothing to do.", "review": "2026-11-17"}
{"start": "2026-09-19T06:15Z", "end": "2026-09-20T07:30Z", "family": "Thermal displacement", "description": "Thermal cycle of the camera, poorly compensated. In the morning, when the housing heats up, the camera turns gradually (tilt rising, pan dropping, scale changing); the raw positions of all the targets and references move together. The compensation does not erase everything: the corr_x of PR18 and PR16 drops a little, the corr_y of PR18 rises, then the curves come back in the afternoon; the camera then comes back slowly, in the evening, then only very little at night, until the start of the next morning. Deduced cause: the pose follows the housing temperature, and the rock face of the quarry cannot move with the temperature. This is not a movement of the structure: nothing to do.", "review": "2026-11-17"}
@@ -1,47 +1,47 @@
{"start": "2026-09-01T00:00Z", "end": "2026-09-07T00:00Z", "family": "Target issue", "description": "The reference R3 is rejected every day, from about 04:00 to 15:00-16:30, and almost never at night: almost all its measurements from 05:00 to 15:00, almost none from 18:00 to 03:00, from 01/09 to 06/09 as since the start of the data (29/08). Its median error_value is markedly above the threshold by day, and markedly below it at night. On its daytime thumbnails (03/09 at 06:00 and 10:00), its spot cannot be seen, while those of R1 and R2 can; at night, under the infrared, it is sharp, smaller than those of R1 and R2 (03/09 at 02:00). The compensation therefore runs every day on five references, and on three as soon as two others are lost (passages in front of R1 and R2, PA_8 or PA1_2 poorly seen in the sun); the entries and exits of R3 do not make the targets jump (median jump of the corr no more than a little above the noise, like the other steps of the day, apart from the passage of 01/09 at 11:00). Cause not established: a reflector too weak for daytime (small, dirty or poorly oriented). Ignore the curve of R3 by day; act on the target (clean it, reorient it or replace it) to give a sixth reference back to the daytime compensation.", "review": "2026-11-17"}
{"start": "2026-09-01T03:45Z", "end": "2026-09-01T16:15Z", "family": "Visibility", "description": "By day, from sunrise to sunset: the error_value of all sensors, references included, rises at sunrise then comes back down in the evening; the peak is at sunrise, when the sun enters the field (seen on the dawn images of the other days). The reference R3 is rejected almost all day, as every day (Target issue, separate label), the target PA_9 at sunrise with the references PA_8 and PA1_2; the corrected curves of the targets are more agitated than at night, without a step. The camera moves in the morning through a thermal effect and the compensation absorbs it: the corrected curves do not keep its wave beyond the noise (not labelled). Cause: daytime heat shimmer above the road, as every day on this station; it cannot be seen directly, the images show the scene in full sun, the spots of the reflectors drowned in the background. Overall well compensated: the structure is not moving, nothing to do; the small daytime oscillations are not a movement."}
{"start": "2026-09-01T03:45Z", "end": "2026-09-01T16:15Z", "family": "Visibility", "description": "By day, from sunrise to sunset: the error_value of all sensors, references included, rises at sunrise then comes back down in the evening; the peak is at sunrise, when the sun enters the field (seen on the dawn images of the other days). The reference R3 is rejected almost all day, as every day (Target issue, separate label), the target PA_9 at sunrise with the references PA_8 and PA1_2; the corrected curves of the targets are more agitated than at night, without a step. The camera moves in the morning through a thermal effect and the compensation absorbs it: the corrected curves do not keep its wave beyond the noise (not labelled). Cause: daytime heat shimmer above the road, as every day on this station; it cannot be seen directly, the images show the scene in full sun, the spots of the reflectors drowned in the background. Overall well compensated: the structure is not moving, nothing to do; the small daytime oscillations are not a movement.", "review": "2026-11-18"}
{"start": "2026-09-01T04:15Z", "end": "2026-09-01T16:30Z", "family": "Visibility", "description": "PB1_2 alone, by day: its error_value rises much more than that of its neighbours PB2_2 and PB4 and approaches the threshold; its corr_x moves away on one side all day and comes back in the evening. On the daytime thumbnails, the target is placed at the edge of the pavement kerb, bright in full sun, and its spot is hard to make out there; at night, under the infrared, the spot is sharp. Cause deduced from the thumbnails: the daylight on the neighbouring kerb; the same time slot comes back every day. The structure is not moving: do not trust the curve of PB1_2 by day.", "review": "2026-11-17"}
{"start": "2026-09-01T14:30Z", "end": "2026-09-01T15:00Z", "family": "Obstruction", "description": "PA3_2 alone: for the time of one measurement, a row of bright points appears just above the target (14:45 thumbnail, absent at 14:30 and at 15:00), probably the lights or reflectors of a passing vehicle; the measurement locks onto one of them while staying under the threshold, and corr_x, corr_y of PA3_2 make a very large jump, then come back at the next measurement. The other targets and the compensation do not move. The structure is not moving: this point of PA3_2 is false, to ignore.", "review": "2026-11-17"}
{"start": "2026-09-01T16:15Z", "end": "2026-09-01T16:45Z", "family": "Obstruction", "description": "At nightfall, for the time of one measurement, the spot of the reference R1 disappears (16:30 thumbnail): its error_value jumps very high, it is rejected; R2, R3 and the target PB4 also rise. Without R1, the basis changes: PB2_2, PB4 and PB_5 jump together on corr_x or corr_y, then come back at the next measurement; their raw positions do not move. Probable cause: a vehicle passing in front of R1, which the night image does not show. The structure is not moving: point to ignore.", "review": "2026-11-17"}
{"start": "2026-09-02T03:45Z", "end": "2026-09-02T16:15Z", "family": "Visibility", "description": "By day, from sunrise to sunset: the error_value of all sensors, references included, rises at sunrise then comes back down in the evening; at sunrise, the sun is in the field, with reflections on the lens (04:45 image). The reference R3 is rejected almost all day, as every day (Target issue, separate label), PA_9 at sunrise with PA_8 and PA1_2; at 05:15 the compensation rejects all its references for the time of one measurement and PA3_2 is rejected; at 07:30 and at 11:15, vehicles pass near the references R1 and R2 (separate labels). The corrected curves of the targets are more agitated than at night, without a step; the camera moves in the morning through a thermal effect and the compensation absorbs it: the corrected curves do not keep its wave beyond the noise (not labelled). Cause: daytime heat shimmer above the road, as every day on this station, not seen directly. Overall well compensated: the structure is not moving, nothing to do."}
{"start": "2026-09-02T03:45Z", "end": "2026-09-02T16:15Z", "family": "Visibility", "description": "By day, from sunrise to sunset: the error_value of all sensors, references included, rises at sunrise then comes back down in the evening; at sunrise, the sun is in the field, with reflections on the lens (04:45 image). The reference R3 is rejected almost all day, as every day (Target issue, separate label), PA_9 at sunrise with PA_8 and PA1_2; at 05:15 the compensation rejects all its references for the time of one measurement and PA3_2 is rejected; at 07:30 and at 11:15, vehicles pass near the references R1 and R2 (separate labels). The corrected curves of the targets are more agitated than at night, without a step; the camera moves in the morning through a thermal effect and the compensation absorbs it: the corrected curves do not keep its wave beyond the noise (not labelled). Cause: daytime heat shimmer above the road, as every day on this station, not seen directly. Overall well compensated: the structure is not moving, nothing to do.", "review": "2026-11-18"}
{"start": "2026-09-02T04:15Z", "end": "2026-09-02T16:45Z", "family": "Visibility", "description": "PB1_2 alone, by day: its error_value rises much more than that of its neighbours and approaches the threshold; its corr_x moves away on one side all day and comes back in the evening. On the daytime thumbnails (05:00, 09:00, 13:00), the target is at the edge of the pavement kerb, bright in full sun, and its spot is hard to make out there; at night, the spot is sharp. Cause deduced from the thumbnails: the daylight on the neighbouring kerb, every day. The structure is not moving: do not trust the curve of PB1_2 by day.", "review": "2026-11-17"}
{"start": "2026-09-02T07:15Z", "end": "2026-09-02T07:45Z", "family": "Obstruction", "description": "At 07:30, vehicles pass near the references R1 and R2: headlights and bright spots on their 07:30 thumbnails. The compensation rejects them for the time of one measurement, the basis changes, and PB4 and PB_5 jump on corr_x (PB4 also on corr_y); everything comes back at the next measurement. The structure is not moving: point to ignore.", "review": "2026-11-17"}
{"start": "2026-09-02T11:00Z", "end": "2026-09-02T11:30Z", "family": "Obstruction", "description": "At 11:15, the references R1 and R2 are rejected for the time of one measurement: on their 11:15 thumbnails, blurry translucent shapes (an inscription near R1, a bright spot near R2), a passing vehicle. The basis changes, PB4 and PB_5 jump on corr_x; everything comes back at the next measurement. The structure is not moving: point to ignore.", "review": "2026-11-17"}
{"start": "2026-09-02T11:45Z", "end": "2026-09-02T12:15Z", "family": "Obstruction", "description": "A vehicle passes in front of PA3_2 and PA_9 (trails and reflections on their 12:00 thumbnails): their error_value jumps, their measurements are rejected for the time of one measurement, along with the reference R2. The other targets do not move; everything comes back at the next measurement. The structure is not moving: point to ignore.", "review": "2026-11-17"}
{"start": "2026-09-03T02:45Z", "end": "2026-09-06T03:00Z", "family": "Obstruction", "description": "PB1_2 alone: at 03:00 on 03/09, its spot almost disappears (03:00 and 03:15 thumbnails, while that of its neighbour PB2_2 is sharp) and its error_value jumps very high. Then, for three days, its spot stays smaller at night (23:00 thumbnails on 03/09 and 04/09, compared with 02/09) and its night error_value stays above its level; by day, it exceeds the threshold for most of the day (measurements rejected) and its corr_x dips much more than on the other days; the night level of its corr_x drops, not that of its neighbours. On 06/09 at 02:45, a one-measurement spike on corr_x, then the night error_value comes back to its level and the spot becomes whole again (06/09 23:00 thumbnail). Cause: something partly covers the spot of PB1_2, of a nature not seen on the images. The structure is not moving: do not trust the curve of PB1_2 over the range; look at what is in front of the target if it comes back.", "review": "2026-11-17"}
{"start": "2026-09-03T03:45Z", "end": "2026-09-03T15:15Z", "family": "Visibility", "description": "By day, from sunrise to sunset: the error_value of all sensors, references included, rises at sunrise then comes back down in the afternoon. The reference R3 is rejected almost all day, as every day (Target issue, separate label), PA_9 at sunrise with PA_8 and PA1_2; at 07:30, a vehicle passes near the references R1 and R2 (separate label); at 09:15, R2 is rejected alone for the time of one measurement, with no jump of the targets. The corrected curves of the targets are more agitated than at night, without a step; the camera moves in the morning through a thermal effect and the compensation absorbs it: the corrected curves do not keep its wave beyond the noise (not labelled). Cause: daytime heat shimmer above the road, as every day on this station, not seen directly. Overall well compensated: the structure is not moving, nothing to do."}
{"start": "2026-09-03T03:45Z", "end": "2026-09-03T15:15Z", "family": "Visibility", "description": "By day, from sunrise to sunset: the error_value of all sensors, references included, rises at sunrise then comes back down in the afternoon. The reference R3 is rejected almost all day, as every day (Target issue, separate label), PA_9 at sunrise with PA_8 and PA1_2; at 07:30, a vehicle passes near the references R1 and R2 (separate label); at 09:15, R2 is rejected alone for the time of one measurement, with no jump of the targets. The corrected curves of the targets are more agitated than at night, without a step; the camera moves in the morning through a thermal effect and the compensation absorbs it: the corrected curves do not keep its wave beyond the noise (not labelled). Cause: daytime heat shimmer above the road, as every day on this station, not seen directly. Overall well compensated: the structure is not moving, nothing to do.", "review": "2026-11-18"}
{"start": "2026-09-03T03:45Z", "end": "2026-09-03T15:15Z", "family": "Visibility", "description": "PB1_2 alone, by day: its error_value exceeds the threshold for most of the day (measurements rejected) and its corr_x moves away on one side, more strongly than on the previous days, before slowly coming back in the evening. As every day, the target is at the edge of the pavement kerb, bright in full sun on the daytime thumbnails; that day its spot is also partly covered (separate label, from 03/09 to 06/09). Cause deduced from the thumbnails: the daylight on the neighbouring kerb. The structure is not moving: do not trust the curve of PB1_2 by day.", "review": "2026-11-17"}
{"start": "2026-09-03T07:15Z", "end": "2026-09-03T07:45Z", "family": "Obstruction", "description": "At 07:30, the headlights of a vehicle shine near the references R2 and R1 (07:30 thumbnails): they are rejected for the time of one measurement, the basis changes, and PB2_2, PB4 and PB_5 jump on corr_x, PB4 also on corr_y; everything comes back at the next measurement. The structure is not moving: point to ignore.", "review": "2026-11-17"}
{"start": "2026-09-03T08:00Z", "end": "2026-09-03T08:30Z", "family": "Obstruction", "description": "A large vehicle passes very close to the camera, in front of the whole scene, seen as translucent on the 08:15 image: the references R1, R2, R3, PA1_2 and PA_8 are rejected, the camera is not recalibrated, the targets PA3_2 and PA_9 are rejected (PB1_2 already is all morning, hindered by the daylight) and PB4 makes a small jump on corr_x. Everything comes back at the next measurement. The structure is not moving: point to ignore.", "review": "2026-11-17"}
{"start": "2026-09-04T03:45Z", "end": "2026-09-04T15:15Z", "family": "Visibility", "description": "By day, from sunrise to sunset: the error_value of all sensors, references included, rises at sunrise then comes back down in the afternoon. The reference R3 is rejected almost all day, as every day (Target issue, separate label), PA_9 at sunrise with PA_8 and PA1_2; at 05:45 and 06:00, at the height of sunrise, the compensation rejects all its references and PA2_2, PA3_2 and PB_5 make a small jump; at 10:15, a vehicle passes near the references R1 and R2 (separate label). The corrected curves of the targets are more agitated than at night, without a step; the camera moves in the morning through a thermal effect and the compensation absorbs it: the corrected curves do not keep its wave beyond the noise (not labelled). Cause: daytime heat shimmer above the road, as every day on this station, not seen directly. Overall well compensated: the structure is not moving, nothing to do."}
{"start": "2026-09-04T03:45Z", "end": "2026-09-04T15:15Z", "family": "Visibility", "description": "By day, from sunrise to sunset: the error_value of all sensors, references included, rises at sunrise then comes back down in the afternoon. The reference R3 is rejected almost all day, as every day (Target issue, separate label), PA_9 at sunrise with PA_8 and PA1_2; at 05:45 and 06:00, at the height of sunrise, the compensation rejects all its references and PA2_2, PA3_2 and PB_5 make a small jump; at 10:15, a vehicle passes near the references R1 and R2 (separate label). The corrected curves of the targets are more agitated than at night, without a step; the camera moves in the morning through a thermal effect and the compensation absorbs it: the corrected curves do not keep its wave beyond the noise (not labelled). Cause: daytime heat shimmer above the road, as every day on this station, not seen directly. Overall well compensated: the structure is not moving, nothing to do.", "review": "2026-11-18"}
{"start": "2026-09-04T03:45Z", "end": "2026-09-04T15:30Z", "family": "Visibility", "description": "PB1_2 alone, by day: its error_value exceeds the threshold for a large part of the day (measurements rejected in late morning) and its corr_x moves away on one side, then comes back in the evening. As every day, the target is at the edge of the pavement kerb, bright in full sun on the 09:00 thumbnail; its spot is also partly covered over the range from 03/09 to 06/09 (separate label). Cause deduced from the thumbnails: the daylight on the neighbouring kerb. The structure is not moving: do not trust the curve of PB1_2 by day.", "review": "2026-11-17"}
{"start": "2026-09-04T06:30Z", "end": "2026-09-04T07:00Z", "family": "Obstruction", "description": "A vehicle passes in front of the targets (headlights near PA3_2, light-coloured bodywork behind PA2_2 and PB2_2 on the 06:45 thumbnails): PA_9 and PB_5 are rejected, with the references PA_8 and R2; PA3_2, which stayed under the threshold, locks onto a headlight and its corr_x, corr_y make a very large jump. Everything comes back at the next measurement. The structure is not moving: this point is false, to ignore.", "review": "2026-11-17"}
{"start": "2026-09-04T10:00Z", "end": "2026-09-04T10:30Z", "family": "Obstruction", "description": "At 10:15, a vehicle passes near the references R1 and R2: lights near R1 and translucent shapes near R2 on their 10:15 thumbnails. They are rejected for the time of one measurement, the basis changes, and PB4, PB_5 and PA3_2 jump; everything comes back at the next measurement. The structure is not moving: point to ignore.", "review": "2026-11-17"}
{"start": "2026-09-05T02:00Z", "end": "2026-09-05T02:30Z", "family": "No data", "description": "The 02:15 measurement is missing for all sensors, the image of that hour too; the metrics continue, the battery and the voltage at their night level. JUNGFRAU and NORDEND also lose a measurement around the same hour on those nights (outside their batches): a common cause outside the station, at night, is probable; it is not established. The curves are missing for the time of one measurement; nothing to do.", "review": "2026-11-17"}
{"start": "2026-09-05T03:30Z", "end": "2026-09-05T08:00Z", "family": "Obstruction", "description": "Cars parked along the pavement hide the reference PB3_2 and the targets PA2_2, PA3_2, PB2_2 and PB_5, seen on the images from 03:45 to 07:45; the scene is clear at 08:00. These sensors have a very high error_value and are rejected almost throughout the range; PA2_2, kept at 04:30, makes a very large jump for the time of one measurement (the measurement probably locks onto a reflection on a car). With PB3_2 hidden and, at sunrise, PA_8 and R3 rejected, the compensation runs on few references, then on none at 05:45 and 06:00 (no recalibration at 06:00): PB4 then makes a one-measurement spike on corr_y. Everything comes back at 08:00. The structure is not moving: ignore the curves of these targets and the spike of PB4 over the range.", "review": "2026-11-17"}
{"start": "2026-09-05T03:45Z", "end": "2026-09-05T15:15Z", "family": "Visibility", "description": "By day, from sunrise to sunset: the error_value of all sensors, references included, rises at sunrise, the sun in the field (03:45 image), then comes back down in the afternoon. The reference R3 is rejected almost all day, as every day (Target issue, separate label), PA_9 at sunrise; at 09:15, a vehicle passes in front of PA_9, which is rejected alone, without effect on the other curves; the morning is mixed with the parked cars in front of some of the targets (separate label). The corrected curves of the targets are more agitated than at night, without a step; the camera moves in the morning through a thermal effect and the compensation absorbs it: the corrected curves do not keep its wave beyond the noise (not labelled). Cause: daytime heat shimmer above the road, as every day on this station, not seen directly. Overall well compensated: the structure is not moving, nothing to do."}
{"start": "2026-09-05T03:45Z", "end": "2026-09-05T15:15Z", "family": "Visibility", "description": "By day, from sunrise to sunset: the error_value of all sensors, references included, rises at sunrise, the sun in the field (03:45 image), then comes back down in the afternoon. The reference R3 is rejected almost all day, as every day (Target issue, separate label), PA_9 at sunrise; at 09:15, a vehicle passes in front of PA_9, which is rejected alone, without effect on the other curves; the morning is mixed with the parked cars in front of some of the targets (separate label). The corrected curves of the targets are more agitated than at night, without a step; the camera moves in the morning through a thermal effect and the compensation absorbs it: the corrected curves do not keep its wave beyond the noise (not labelled). Cause: daytime heat shimmer above the road, as every day on this station, not seen directly. Overall well compensated: the structure is not moving, nothing to do.", "review": "2026-11-18"}
{"start": "2026-09-05T03:45Z", "end": "2026-09-05T16:45Z", "family": "Visibility", "description": "PB1_2 alone, by day: its error_value exceeds the threshold for a large part of the day (measurements rejected from late morning to early afternoon) and its corr_x moves away on one side, then comes back in the evening. As every day, the target is at the edge of the pavement kerb, bright in full sun on the 09:00 thumbnail; its spot is also partly covered over the range from 03/09 to 06/09 (separate label). Cause deduced from the thumbnails: the daylight on the neighbouring kerb. The structure is not moving: do not trust the curve of PB1_2 by day.", "review": "2026-11-17"}
{"start": "2026-09-05T11:45Z", "end": "2026-09-05T12:15Z", "family": "Obstruction", "description": "A vehicle passes in front of PA3_2 and PB4 (blurry shapes on their 12:00 thumbnails): their measurements are rejected for the time of one measurement, with the reference R2, and PA2_2 makes a small jump. Everything comes back at the next measurement. The structure is not moving: point to ignore.", "review": "2026-11-17"}
{"start": "2026-09-06T01:45Z", "end": "2026-09-06T02:15Z", "family": "No data", "description": "The 02:00 measurement is missing for all sensors, the image of that hour too; the metrics continue, the battery and the voltage at their night level. JUNGFRAU and NORDEND also lose a measurement around the same hour on those nights (outside their batches): a common cause outside the station, at night, is probable; it is not established. The curves are missing for the time of one measurement; nothing to do.", "review": "2026-11-17"}
{"start": "2026-09-06T03:45Z", "end": "2026-09-06T14:30Z", "family": "Visibility", "description": "PB1_2 alone, by day: its error_value rises much more than that of its neighbours, exceeds the threshold at times (a few measurements rejected), and its corr_y then its corr_x move away from their level before coming back in the evening. As every day, the target is at the edge of the pavement kerb, bright in full sun on the 09:00 thumbnail. Cause deduced from the thumbnails: the daylight on the neighbouring kerb. The structure is not moving: do not trust the curve of PB1_2 by day.", "review": "2026-11-17"}
{"start": "2026-09-06T03:45Z", "end": "2026-09-06T15:00Z", "family": "Visibility", "description": "By day, from sunrise to sunset: the error_value of all sensors, references included, rises at sunrise then comes back down in the afternoon. The reference R3 is rejected almost all day, as every day (Target issue, separate label), PA_9 at sunrise with PA_8; at 07:15, when the compensation rejects its references for the time of one measurement, PB4, PB2_2 and PB_5 make a small jump; at 09:30, a vehicle passes (separate label). The corrected curves of the targets are more agitated than at night, without a step; the camera moves in the morning through a thermal effect and the compensation absorbs it: the corrected curves do not keep its wave beyond the noise (not labelled). Cause: daytime heat shimmer above the road, as every day on this station, not seen directly. Overall well compensated: the structure is not moving, nothing to do."}
{"start": "2026-09-06T03:45Z", "end": "2026-09-06T15:00Z", "family": "Visibility", "description": "By day, from sunrise to sunset: the error_value of all sensors, references included, rises at sunrise then comes back down in the afternoon. The reference R3 is rejected almost all day, as every day (Target issue, separate label), PA_9 at sunrise with PA_8; at 07:15, when the compensation rejects its references for the time of one measurement, PB4, PB2_2 and PB_5 make a small jump; at 09:30, a vehicle passes (separate label). The corrected curves of the targets are more agitated than at night, without a step; the camera moves in the morning through a thermal effect and the compensation absorbs it: the corrected curves do not keep its wave beyond the noise (not labelled). Cause: daytime heat shimmer above the road, as every day on this station, not seen directly. Overall well compensated: the structure is not moving, nothing to do.", "review": "2026-11-18"}
{"start": "2026-09-06T05:45Z", "end": "2026-09-06T06:15Z", "family": "Obstruction", "description": "At sunrise, a blurry silhouette passes on the pavement near PB1_2 and PB2_2 (06:00 image), which are rejected for the time of one measurement; with the references rejected by the morning light, the compensation retains none at that moment, and PA3_2, PB4 and PB_5 make a small jump on corr_x. Everything comes back at the next measurement. Probable cause: a passer-by; the structure is not moving, point to ignore.", "review": "2026-11-17"}
{"start": "2026-09-06T09:15Z", "end": "2026-09-06T09:45Z", "family": "Obstruction", "description": "For the time of one measurement, a vehicle passes in the background, near the references R1 and R2: its lights and bodywork can be seen as translucent on their 09:30 thumbnails. R1, R2 and PA_8 are rejected, the basis changes and PB4 makes a small jump; everything comes back at the next measurement. The structure is not moving: point to ignore.", "review": "2026-11-17"}
{"start": "2026-09-06T12:00Z", "end": "2026-09-06T12:30Z", "family": "Obstruction", "description": "A light-coloured vehicle passes on the lane along the pavement and covers PB1_2 and PB2_2 (12:15 thumbnails): they are rejected for the time of one measurement, with the reference PA_8. Everything comes back at the next measurement. The structure is not moving: point to ignore.", "review": "2026-11-17"}
{"start": "2026-09-06T14:15Z", "end": "2026-09-06T14:45Z", "family": "Obstruction", "description": "For the time of one measurement, bright points appear near PA_9 and the reference PA_8 (14:30 thumbnail, absent at 14:15 and at 14:45), probably the reflections of a passing vehicle: PA_8 is rejected; PA_9, which stayed under the threshold, locks onto one of them and its corr_x, corr_y make a very large jump. Everything comes back at the next measurement. The structure is not moving: this point of PA_9 is false, to ignore.", "review": "2026-11-17"}
{"start": "2026-09-07T03:30Z", "end": "2026-09-07T16:00Z", "family": "Visibility", "description": "By day, from sunrise to mid-afternoon: the error_value of all sensors, references included, rises at sunrise and comes back down in the afternoon; the reference R3 is rejected almost all day, as every day (Target issue, separate label). PA_9 is rejected at sunrise with the references PA_8 and R2; at 06:45 the compensation retains no reference and PB4 is rejected, the roadway covered with bright reflections of the low sun on the 06:45 image; PA2_2 and PA3_2 are rejected at 06:00, PB1_2 with the reference PA1_2 at 05:00 and 10:15, when PA2_2 and PA3_2 make a small jump; at 09:45, a vehicle passes in front of R1 and R2 (separate label). Before the outage of 09/09, the reflectors are seen less well by day than after (08/09 thumbnails compared with 23/09) and these rejections are more numerous. The corrected curves of the targets are more agitated than at night, without a clean step; the camera moves in the morning through a thermal effect and the compensation absorbs it: the corrected curves do not keep its wave beyond the noise (not labelled). Deduced cause: daytime heat shimmer above the road, which the expert gives as a trait of the station (curve noise and error_value rising by day only), and the low sun at sunrise; it cannot be seen directly, the images show the scene in full daylight. Overall compensated: the structure is not moving, do not trust the small oscillations of the day."}
{"start": "2026-09-07T03:30Z", "end": "2026-09-07T16:00Z", "family": "Visibility", "description": "By day, from sunrise to mid-afternoon: the error_value of all sensors, references included, rises at sunrise and comes back down in the afternoon; the reference R3 is rejected almost all day, as every day (Target issue, separate label). PA_9 is rejected at sunrise with the references PA_8 and R2; at 06:45 the compensation retains no reference and PB4 is rejected, the roadway covered with bright reflections of the low sun on the 06:45 image; PA2_2 and PA3_2 are rejected at 06:00, PB1_2 with the reference PA1_2 at 05:00 and 10:15, when PA2_2 and PA3_2 make a small jump; at 09:45, a vehicle passes in front of R1 and R2 (separate label). Before the outage of 09/09, the reflectors are seen less well by day than after (08/09 thumbnails compared with 23/09) and these rejections are more numerous. The corrected curves of the targets are more agitated than at night, without a clean step; the camera moves in the morning through a thermal effect and the compensation absorbs it: the corrected curves do not keep its wave beyond the noise (not labelled). Deduced cause: daytime heat shimmer above the road, which the expert gives as a trait of the station (curve noise and error_value rising by day only), and the low sun at sunrise; it cannot be seen directly, the images show the scene in full daylight. Overall compensated: the structure is not moving, do not trust the small oscillations of the day.", "review": "2026-11-18"}
{"start": "2026-09-07T04:00Z", "end": "2026-09-07T12:45Z", "family": "Visibility", "description": "The reference PA_8 is rejected for a good part of the morning, intermittently: the compensation runs without it (and without R3), and the basis changes. The targets PA_9, its neighbour in the image, and PA2_2, PA3_2 rise on corr_x and y stay there as long as PA_8 is missing, PA_9 especially, less markedly than on the two following days; they come back in the afternoon when PA_8 is taken again. On the daytime thumbnails from before the outage (08/09 and 09/09 at 09:00), the spot of PA_8 is only a dull point on the light background, while it is sharp on that of 23/09 at the same hour. Cause: PA_8 poorly seen in full daylight. This is not a movement: curves of PA_9, PA2_2 and PA3_2 not to be trusted over the range.", "review": "2026-11-17"}
{"start": "2026-09-07T06:45Z", "end": "2026-09-07T15:00Z", "family": "Visibility", "description": "PB1_2 alone, by day: its error_value rises much more than that of its neighbours PB2_2 and PB4, and its corr_x moves away on one side from the morning to mid-afternoon, then comes back. As on the other days, the target is at the edge of the pavement kerb, bright in full sun (28/09 daytime thumbnails: its dark spot touches the light band of the kerb); at night, under the infrared, the spot is sharp. Cause deduced from the thumbnails: the daylight on the neighbouring kerb. The structure is not moving: do not trust the curve of PB1_2 over the range.", "review": "2026-11-17"}
{"start": "2026-09-07T09:30Z", "end": "2026-09-07T10:00Z", "family": "Obstruction", "description": "A vehicle passes in front of the references R1 and R2, seen as translucent on their 09:45 thumbnails, a bus and cars on the image: R1 and R2 are rejected, R3 set aside, the basis changes for the time of one measurement; the targets barely move, PB4 a little on corr_x. Everything comes back at the next measurement. The structure is not moving: point to ignore.", "review": "2026-11-17"}
{"start": "2026-09-07T14:00Z", "end": "2026-09-07T14:45Z", "family": "Obstruction", "description": "A group of passers-by crosses in front of the targets: on the 14:30 image, a line of translucent silhouettes passes in front of PA3_2, PB_5, PB4 and the reference R2. PA_9 is rejected at 14:15 and 14:30, PA3_2, PB4 and R2 at 14:30; PB_5, which stayed under the threshold, makes a small jump on corr_x. Everything comes back at the next measurement. The structure is not moving: points to ignore.", "review": "2026-11-17"}
{"start": "2026-09-08T02:30Z", "end": "2026-09-08T03:15Z", "family": "Obstruction", "description": "At night, PB1_2 alone: its corr_x makes a jump at 02:45, then its corr_y at 03:00, and everything comes back at 03:15; the other targets and the compensation do not move. The 02:45 thumbnail shows no clear change in its spot. Cause not established, not seen: a passing disturbance in front of the spot, like those that come back at the same hour of the night on the kerb targets (PB1_2 on 03/09 and 01/10, PB2_2 on 24 and 25/09). The structure is not moving: point to ignore.", "review": "2026-11-17"}
{"start": "2026-09-08T03:30Z", "end": "2026-09-08T15:30Z", "family": "Visibility", "description": "By day, from sunrise to mid-afternoon: the error_value of all sensors, references included, rises at sunrise and comes back down in the afternoon; the reference R3 is rejected almost all day, as every day (Target issue, separate label). PA_9 is rejected almost throughout sunrise; at 05:30, PA2_2, PA3_2, PB4 and PB_5 are rejected with R2 and PA_8; at 06:00 and from 06:30 to 06:45, the compensation retains no reference (R1, R2, PA_8, R3 rejected), PA3_2 is rejected at 06:00, PB4 at 06:30; R1, right at its threshold, is rejected several times in the morning; from 08:15 to 09:00, vehicles pass in front of R2 (two separate labels). Before the outage of 09/09, the reflectors are seen less well by day than after (09:00 thumbnails compared with 23/09). The corrected curves of the targets are more agitated than at night, without a clean step; the camera moves in the morning through a thermal effect and the compensation absorbs it: the corrected curves do not keep its wave beyond the noise (not labelled). Deduced cause: daytime heat shimmer above the road, which the expert gives as a trait of the station (curve noise and error_value rising by day only), and the low sun at sunrise; it cannot be seen directly, the images show the scene in full daylight. Overall compensated: the structure is not moving, do not trust the small oscillations of the day."}
{"start": "2026-09-08T03:30Z", "end": "2026-09-08T15:30Z", "family": "Visibility", "description": "By day, from sunrise to mid-afternoon: the error_value of all sensors, references included, rises at sunrise and comes back down in the afternoon; the reference R3 is rejected almost all day, as every day (Target issue, separate label). PA_9 is rejected almost throughout sunrise; at 05:30, PA2_2, PA3_2, PB4 and PB_5 are rejected with R2 and PA_8; at 06:00 and from 06:30 to 06:45, the compensation retains no reference (R1, R2, PA_8, R3 rejected), PA3_2 is rejected at 06:00, PB4 at 06:30; R1, right at its threshold, is rejected several times in the morning; from 08:15 to 09:00, vehicles pass in front of R2 (two separate labels). Before the outage of 09/09, the reflectors are seen less well by day than after (09:00 thumbnails compared with 23/09). The corrected curves of the targets are more agitated than at night, without a clean step; the camera moves in the morning through a thermal effect and the compensation absorbs it: the corrected curves do not keep its wave beyond the noise (not labelled). Deduced cause: daytime heat shimmer above the road, which the expert gives as a trait of the station (curve noise and error_value rising by day only), and the low sun at sunrise; it cannot be seen directly, the images show the scene in full daylight. Overall compensated: the structure is not moving, do not trust the small oscillations of the day.", "review": "2026-11-18"}
{"start": "2026-09-08T04:00Z", "end": "2026-09-08T14:30Z", "family": "Visibility", "description": "The reference PA_8 is rejected almost all day: the compensation runs without it (and without R3), and the basis changes. The targets PA_9, its neighbour in the image, and PA2_2, PA3_2 rise on corr_x and y stay there as long as PA_8 is missing, PA_9 especially; they come back in the afternoon when PA_8 is taken again. On the daytime thumbnails from before the outage (08/09 and 09/09 at 09:00), the spot of PA_8 is only a dull point on the light background, while it is sharp on that of 23/09 at the same hour. Cause: PA_8 poorly seen in full daylight. This is not a movement: curves of PA_9, PA2_2 and PA3_2 not to be trusted over the range.", "review": "2026-11-17"}
{"start": "2026-09-08T06:45Z", "end": "2026-09-08T16:00Z", "family": "Visibility", "description": "PB1_2 alone, by day: its error_value rises much more than that of its neighbours PB2_2 and PB4, and its corr_x moves away on one side from the morning to late afternoon; its corr_y also drops and comes back only in part in the evening. As on the other days, the target is at the edge of the pavement kerb, bright in full sun (28/09 daytime thumbnails: its dark spot touches the light band of the kerb); at night, under the infrared, the spot is sharp. Cause deduced from the thumbnails: the daylight on the neighbouring kerb. The structure is not moving: do not trust the curve of PB1_2 over the range.", "review": "2026-11-17"}
{"start": "2026-09-08T08:00Z", "end": "2026-09-08T08:45Z", "family": "Obstruction", "description": "Vehicles pass in front of the reference R2: a line of bright reflections near it and PB4 on the 08:15 image, a flash on R2 at 08:30. R2 is rejected two measurements in a row; at 08:15, with R1 right at its threshold and PA_8 poorly seen that day, the compensation retains no reference; at 08:30, PA_9, PA2_2 and PB_5 make a small jump on corr_x. Everything comes back at 08:45. The structure is not moving: points to ignore.", "review": "2026-11-17"}
{"start": "2026-09-08T08:45Z", "end": "2026-09-08T09:15Z", "family": "Obstruction", "description": "A vehicle passes in front of PA3_2 and the reference R2, seen as translucent on the 09:00 image: PA_9 and PA3_2 are rejected for the time of one measurement, with R2, R3 and PA_8; PA2_2 makes a small jump on corr_x. Everything comes back at the next measurement. The structure is not moving: point to ignore.", "review": "2026-11-17"}
{"start": "2026-09-08T13:15Z", "end": "2026-09-08T13:45Z", "family": "Obstruction", "description": "Passers-by walk on the pavement near PA2_2 and the reference PA1_2, blurry silhouettes on the 13:30 image: PA1_2 is rejected and PA2_2 makes a jump on corr_x for the time of one measurement. Everything comes back at the next measurement. The structure is not moving: point to ignore.", "review": "2026-11-17"}
{"start": "2026-09-09T03:30Z", "end": "2026-09-09T15:45Z", "family": "Visibility", "description": "By day, from sunrise to mid-afternoon: the error_value of all sensors, references included, rises at sunrise and comes back down in the afternoon; the reference R3 is rejected almost all day, as every day (Target issue, separate label). PA_9 is rejected throughout sunrise; from 05:30 to 06:30, the compensation retains no reference (PA1_2, PA_8, R2, R3 rejected), PA2_2, PA3_2 and PB_5 are rejected at 05:45, PB4 at 05:15, and at 06:30 PA2_2, PA3_2, PB4 and PB_5 make a small jump. Before the outage, the reflectors are seen less well by day than after (09:00 thumbnails compared with 23/09). The corrected curves of the targets are more agitated than at night, without a clean step; the camera moves in the morning through a thermal effect and the compensation absorbs it: the corrected curves do not keep its wave beyond the noise (not labelled). Deduced cause: daytime heat shimmer above the road, which the expert gives as a trait of the station (curve noise and error_value rising by day only), and the low sun at sunrise; it cannot be seen directly, the images show the scene in full daylight. Overall compensated: the structure is not moving, do not trust the small oscillations of the day."}
{"start": "2026-09-09T03:30Z", "end": "2026-09-09T15:45Z", "family": "Visibility", "description": "By day, from sunrise to mid-afternoon: the error_value of all sensors, references included, rises at sunrise and comes back down in the afternoon; the reference R3 is rejected almost all day, as every day (Target issue, separate label). PA_9 is rejected throughout sunrise; from 05:30 to 06:30, the compensation retains no reference (PA1_2, PA_8, R2, R3 rejected), PA2_2, PA3_2 and PB_5 are rejected at 05:45, PB4 at 05:15, and at 06:30 PA2_2, PA3_2, PB4 and PB_5 make a small jump. Before the outage, the reflectors are seen less well by day than after (09:00 thumbnails compared with 23/09). The corrected curves of the targets are more agitated than at night, without a clean step; the camera moves in the morning through a thermal effect and the compensation absorbs it: the corrected curves do not keep its wave beyond the noise (not labelled). Deduced cause: daytime heat shimmer above the road, which the expert gives as a trait of the station (curve noise and error_value rising by day only), and the low sun at sunrise; it cannot be seen directly, the images show the scene in full daylight. Overall compensated: the structure is not moving, do not trust the small oscillations of the day.", "review": "2026-11-18"}
{"start": "2026-09-09T03:45Z", "end": "2026-09-09T15:00Z", "family": "Visibility", "description": "The reference PA_8 is rejected almost all day: the compensation runs without it (and without R3), and the basis changes. The targets PA_9, its neighbour in the image, and PA2_2, PA3_2 rise on corr_x and y stay there as long as PA_8 is missing, PA_9 especially; they come back in the afternoon when PA_8 is taken again. On the daytime thumbnails from before the outage (08/09 and 09/09 at 09:00), the spot of PA_8 is only a dull point on the light background, while it is sharp on that of 23/09 at the same hour. Cause: PA_8 poorly seen in full daylight. This is not a movement: curves of PA_9, PA2_2 and PA3_2 not to be trusted over the range.", "review": "2026-11-17"}
{"start": "2026-09-09T07:30Z", "end": "2026-09-09T21:45Z", "family": "Visibility", "description": "PB1_2 alone, by day: its error_value rises much more than that of its neighbours PB2_2 and PB4, and its corr_x moves away on one side from mid-morning; in the evening, it comes back only in part, and stays lower until the night outage. As on the other days, the target is at the edge of the pavement kerb, bright in full sun; at night, under the infrared, the spot is sharp. Cause deduced from the thumbnails: the daylight on the neighbouring kerb, without the evening return being complete. The structure is not moving: do not trust the curve of PB1_2 over the range.", "review": "2026-11-17"}
{"start": "2026-09-09T09:30Z", "end": "2026-09-09T10:00Z", "family": "Obstruction", "description": "A vehicle passes in front of PA3_2, R2, PB4 and R1, seen as translucent on the 09:45 image: PA3_2 and PB4 are rejected, with the references PB3_2, R2 and PA_8, and the compensation retains no reference; PB_5 makes a jump on corr_x and corr_y. Everything comes back at the next measurement. The structure is not moving: point to ignore.", "review": "2026-11-17"}
@@ -1,5 +1,4 @@
{"start": "2026-09-07T00:00Z", "end": "2026-10-01T00:00Z", "family": "Target issue", "description": "The reference R3 is rejected on every measured day of the batch (from 07 to 09/09, then from 22 to 30/09), from sunrise until mid-afternoon, and almost never at night: by day, its error_value stays above its threshold at almost every measurement, a little less often in the last days of September; at night, it is well below. On its daytime thumbnail (30/09 at 10:00), its spot cannot be seen, while those of R1 and R2 can; at night, under the infrared, it is sharp, smaller than theirs (03/09 at 02:00 thumbnail). It is rejected as much before as after the outage from 09/09 to 22/09, when the other reflectors are better seen: it is the target, not the daytime sun. The compensation therefore runs every day on five references, and on three or fewer as soon as two others are lost (PA_8 poorly seen before the outage, passages in front of R1 and R2, sunrise, separate labels); its entries and exits do not make the targets jump. Cause not established: a reflector too weak for daytime (small, dirty or poorly oriented). Ignore the curve of R3 by day; act on the target (clean it, reorient it or replace it) to give a sixth reference back to the daytime compensation.", "review": "2026-11-17"}
{"start": "2026-09-09T21:45Z", "end": "2026-09-22T08:45Z", "family": "No data", "description": "No measurement for any sensor for nearly two weeks; the metrics and the images stop with the measurements. Just before, the battery empties and the voltage falls well below its level of the other nights (metrics): the station shuts down for lack of energy. It restarts on 22/09 in the morning, the battery full and a voltage much higher than usual, as on an external power supply; on return, the tilt of the camera is no longer at the same night level as before the outage. The curves are missing: the station ran out of energy, to be checked (battery, panel, possible intervention).", "review": "2026-11-17"}
{"start": "2026-09-09T21:45Z", "end": "2026-09-22T09:00Z", "family": "Displacement", "description": "During the outage from 09/09 to 22/09, the corrected curves change level and do not resume the one from before: corr_y of PB1_2 markedly lower, corr_y of PB2_2 lower, corr_x of PB_5, PA2_2, PA3_2 and PB4 lower, corr_y of PA_9 higher, from the first measurement. The jump is hidden in the outage; the step lasts until the end of the batch, except for PB_5, back near its level from before on 30/09 (labelled separately), and PB1_2 keeps going down from 25 to 29/09 (labelled separately). The camera is no longer at the same night level (tilt and rotation shifted). Relative to the overall movement of the targets, the raw position of PB1_2 has shifted alone, and the references PA_8 and PA1_2 a little relative to each other, which changes the basis of the other targets. After the restart, the reflectors are seen better, by day and by night, and the error_value of all sensors is lower; the housing temperature has the same cycle before and after. Cause not established: an intervention on the station during the outage (adjustment, cleaning), or, for PB1_2, a movement of the kerb. For the targets that follow the basis, this is not a movement of the structure: do not compare the levels from before and after the outage, to be checked with the operator; for PB1_2, a movement is not excluded: look at the target, keep watching.", "review": "2026-11-17"}
{"start": "2026-10-01T00:00Z", "end": "2026-11-01T00:00Z", "family": "Target issue", "description": "The reference R3 is rejected every measured day, from the first measurement of the morning (04:30 to 05:45) until 13:30-16:30, and almost never at night: most of the measurements from 05:00 to 15:00, often all of them, from 01/10 to 09/10, and at the only daytime measurement of 15/10 (08:00); almost none at night. Its median error_value is markedly above the threshold by day, and a little below it at night. It is as much so on the days when the housing heats up least (on 08/10, almost all its daytime measurements): it is not the daytime sun, it is the target. On its daytime thumbnails, its spot cannot be seen (30/09 at 10:00), while those of R1 and R2 can. The compensation therefore runs every day on five references, and on three or fewer when two others are lost (passages, PA_8 and PA1_2 poorly seen in the sun, separate labels); its entries and exits do not make the targets jump (median jump of the corr no more than a little above the noise, like the other steps of the day, apart from the moments already labelled). No daytime measurement after 15/10: no return seen, until the end of the batch. Cause not established: a reflector too weak for daytime (small, dirty or poorly oriented). Ignore the curve of R3 by day; act on the target (clean it, reorient it or replace it).", "review": "2026-11-17"}
{"start": "2026-10-15T08:00Z", "end": "2026-10-31T20:15Z", "family": "No data", "description": "No measurement for any sensor for more than two weeks; the metrics and the images are also missing almost all that time (two isolated values on 25/10), and come back only on 30/10 in the evening, the battery well charged but not full; it is full only on 31/10 in the morning, with daytime images on 31/10, still without a displacement measurement until that evening. Cause not established (station stopped). The curves are missing: to be checked with the operator."}
{"start": "2026-10-15T08:00Z", "end": "2026-10-31T20:15Z", "family": "No data", "description": "No measurement for any sensor for more than two weeks; the metrics and the images are also missing almost all that time (two isolated values on 25/10), and come back only on 30/10 in the evening, the battery well charged but not full; it is full only on 31/10 in the morning, with daytime images on 31/10, still without a displacement measurement until that evening. Cause not established (station stopped). The curves are missing: to be checked with the operator.", "review": "2026-11-18"}
@@ -1,11 +1,11 @@
{"start": "2026-09-22T08:45Z", "end": "2026-09-22T09:00Z", "family": "Visibility", "description": "First measurement after the restart of the station: the image of 08:45 is darker over the whole scene than those just before and after (thumbnails), the error_value of most sensors is high, and the references R1, R2 and R3 are rejected with the targets PB4 and PA3_2; the compensation runs on the three remaining references and the basis changes: PB_5 jumps strongly on corr_x, PB2_2 on corr_x and corr_y, PB1_2 on corr_y, PA2_2 and PA_9 a little, together. Everything is back at the next measurement. Cause deduced from the images: an exposure not yet settled at the first image after the restart; why is not established. The structure is not moving: point to ignore."}
{"start": "2026-09-22T08:45Z", "end": "2026-09-22T12:30Z", "family": "Thermal displacement", "description": "At the restart, in mid-morning, the camera is still nodded down: its tilt, high, comes back down until noon, goes a little below its evening level then returns to it in early afternoon, with its scale (which comes back more slowly), and all the raw positions, references included, move together in the image, like the next day at the same hours, while the housing temperature is at its daytime high. The compensation absorbs most of it, not all: the corr_y of PB2_2, and less of PB1_2, stay clearly above their night level while the tilt is high and come back down with it in late morning; the other targets keep nothing of it beyond the noise. Deduced cause: the mount or the lens of the camera heats up in the sun (the targets PB2_2 and PB1_2 keep a remainder that follows the tilt, on both days); according to the expert, the road hardly moves with temperature. Normal, nothing to do for the structure; the small morning rise of corr_y on PB2_2 and PB1_2 is not a movement."}
{"start": "2026-09-22T08:45Z", "end": "2026-09-22T13:00Z", "family": "Visibility", "description": "PB1_2 alone, on the morning of the restart: its corr_x moves strongly away on one side, then comes back little by little until early afternoon; relative to the overall movement of the targets, its raw position slides alone in the image and comes back, while its neighbours PB2_2 and PB4 stay with the others. Its error_value rises by day like that of all the targets, not more. On the thumbnails of 09:00 and 11:00, the spot of PB1_2 sits on the light band of the pavement kerb, bright in full sun; at 14:45 the kerb is in the shade and the curve is back; at night, under the infrared, the spot is sharp. Cause deduced from the thumbnails: the sunlit kerb next to the spot pulls its measured centre. The next morning, under the same light, the dip is much weaker. The structure is not moving: do not trust the curve of PB1_2 over the range."}
{"start": "2026-09-22T08:45Z", "end": "2026-09-22T15:15Z", "family": "Visibility", "description": "By day, from the restart in mid-morning to mid-afternoon: the error_value of all sensors, references included, is high and comes back down in the afternoon; the reference R3 is rejected almost all day, as every day (Target issue, separate label). The corrected curves of the targets are more agitated than at night, isolated points of PA3_2 and of other targets standing out a little beyond the noise, without a step; nothing like this at night. The jump of the first measurement after the restart, the slide of PB1_2 and the remainder of the camera movement on PB2_2 have their own labels. Deduced cause: daytime heat shimmer above the road, which the expert gives as a trait of the station (curve noise and error_value rising by day only); it cannot be seen directly, the images show the scene in full daylight. The structure is not moving: do not trust the small oscillations of the day."}
{"start": "2026-09-22T08:45Z", "end": "2026-09-22T09:00Z", "family": "Visibility", "description": "First measurement after the restart of the station: the image of 08:45 is darker over the whole scene than those just before and after (thumbnails), the error_value of most sensors is high, and the references R1, R2 and R3 are rejected with the targets PB4 and PA3_2; the compensation runs on the three remaining references and the basis changes: PB_5 jumps strongly on corr_x, PB2_2 on corr_x and corr_y, PB1_2 on corr_y, PA2_2 and PA_9 a little, together. Everything is back at the next measurement. Cause deduced from the images: an exposure not yet settled at the first image after the restart; why is not established. The structure is not moving: point to ignore.", "review": "2026-11-18"}
{"start": "2026-09-22T08:45Z", "end": "2026-09-22T12:30Z", "family": "Thermal displacement", "description": "At the restart, in mid-morning, the camera is still nodded down: its tilt, high, comes back down until noon, goes a little below its evening level then returns to it in early afternoon, with its scale (which comes back more slowly), and all the raw positions, references included, move together in the image, like the next day at the same hours, while the housing temperature is at its daytime high. The compensation absorbs most of it, not all: the corr_y of PB2_2, and less of PB1_2, stay clearly above their night level while the tilt is high and come back down with it in late morning; the other targets keep nothing of it beyond the noise. Deduced cause: the mount or the lens of the camera heats up in the sun (the targets PB2_2 and PB1_2 keep a remainder that follows the tilt, on both days); according to the expert, the road hardly moves with temperature. Normal, nothing to do for the structure; the small morning rise of corr_y on PB2_2 and PB1_2 is not a movement.", "review": "2026-11-18"}
{"start": "2026-09-22T08:45Z", "end": "2026-09-22T13:00Z", "family": "Visibility", "description": "PB1_2 alone, on the morning of the restart: its corr_x moves strongly away on one side, then comes back little by little until early afternoon; relative to the overall movement of the targets, its raw position slides alone in the image and comes back, while its neighbours PB2_2 and PB4 stay with the others. Its error_value rises by day like that of all the targets, not more. On the thumbnails of 09:00 and 11:00, the spot of PB1_2 sits on the light band of the pavement kerb, bright in full sun; at 14:45 the kerb is in the shade and the curve is back; at night, under the infrared, the spot is sharp. Cause deduced from the thumbnails: the sunlit kerb next to the spot pulls its measured centre. The next morning, under the same light, the dip is much weaker. The structure is not moving: do not trust the curve of PB1_2 over the range.", "review": "2026-11-18"}
{"start": "2026-09-22T08:45Z", "end": "2026-09-22T15:15Z", "family": "Visibility", "description": "By day, from the restart in mid-morning to mid-afternoon: the error_value of all sensors, references included, is high and comes back down in the afternoon; the reference R3 is rejected almost all day, as every day (Target issue, separate label). The corrected curves of the targets are more agitated than at night, isolated points of PA3_2 and of other targets standing out a little beyond the noise, without a step; nothing like this at night. The jump of the first measurement after the restart, the slide of PB1_2 and the remainder of the camera movement on PB2_2 have their own labels. Deduced cause: daytime heat shimmer above the road, which the expert gives as a trait of the station (curve noise and error_value rising by day only); it cannot be seen directly, the images show the scene in full daylight. The structure is not moving: do not trust the small oscillations of the day.", "review": "2026-11-18"}
{"start": "2026-09-22T17:00Z", "end": "2026-09-22T17:30Z", "family": "Obstruction", "description": "At nightfall, the headlights of a vehicle appear very close to the reference R1 (17:15 thumbnail): the measurement of R1 locks onto a headlight, the compensation rejects it and the basis changes; PB4 makes a jump on corr_x for the time of one measurement. Everything comes back at the next measurement. The structure is not moving: point to ignore.", "review": "2026-11-17"}
{"start": "2026-09-23T04:00Z", "end": "2026-09-23T05:00Z", "family": "Visibility", "description": "At sunrise, the sun enters the field of the camera (04:15 image: the sun just above the buildings, flare across the image, the scene underexposed): the error_value of all sensors jumps, the reference PA_8 is rejected for two measurements and PA_9 for two; the compensation runs without PA_8 and the basis changes: PA_9 and PA2_2 jump clearly on corr_x, PA2_2 also on corr_y, PB1_2 a little, together. Back at the next measurement once the sun has passed. Cause seen on the image: the sun in the field. The structure is not moving: points to ignore."}
{"start": "2026-09-23T04:00Z", "end": "2026-09-23T12:15Z", "family": "Thermal displacement", "description": "At sunrise, the camera nods down: its tilt rises, with its scale, while its rotation and its pan first dip then swing above their night level in mid-morning, and all the raw positions, references included, move together in the image; the tilt peaks in early morning, goes below its night level in late morning, then comes back to it in early afternoon, while the housing temperature rises strongly; the scale comes back more slowly, until mid-afternoon. The compensation absorbs most of it, not all: the corr_y of PB1_2 and PB2_2 rise clearly above their night level while the tilt is high and come back with it in late morning; the other targets keep nothing of it beyond the noise. Deduced cause: the mount or the lens of the camera heats up in the sun (the same remainder on PB2_2 and PB1_2 as the day before, following the tilt); according to the expert, the road hardly moves with temperature. Normal, nothing to do for the structure; the small morning rise of corr_y on PB1_2 and PB2_2 is not a movement."}
{"start": "2026-09-23T04:00Z", "end": "2026-09-23T15:15Z", "family": "Visibility", "description": "By day, from sunrise to mid-afternoon: the error_value of all sensors, references included, rises at sunrise and comes back down in the afternoon; the reference R3 is rejected almost all day, as every day (Target issue, separate label). In early morning, with the low sun, PB4 is rejected for about an hour, R2 for two measurements, and PA_9 makes small jumps. The corrected curves of the targets are more agitated than at night, isolated points of PA_9, PA3_2, PB1_2, PB2_2 and PB_5 standing out a little beyond the noise, without a step; nothing like this at night. The sun in the field at sunrise, the remainder of the camera movement on PB1_2 and PB2_2, and the vehicle passages have their own labels. Deduced cause: daytime heat shimmer above the road, which the expert gives as a trait of the station (curve noise and error_value rising by day only), and the low sun in the morning; the shimmer cannot be seen directly, the images show the scene in full daylight. The structure is not moving: do not trust the small oscillations of the day."}
{"start": "2026-09-23T04:00Z", "end": "2026-09-23T05:00Z", "family": "Visibility", "description": "At sunrise, the sun enters the field of the camera (04:15 image: the sun just above the buildings, flare across the image, the scene underexposed): the error_value of all sensors jumps, the reference PA_8 is rejected for two measurements and PA_9 for two; the compensation runs without PA_8 and the basis changes: PA_9 and PA2_2 jump clearly on corr_x, PA2_2 also on corr_y, PB1_2 a little, together. Back at the next measurement once the sun has passed. Cause seen on the image: the sun in the field. The structure is not moving: points to ignore.", "review": "2026-11-18"}
{"start": "2026-09-23T04:00Z", "end": "2026-09-23T12:15Z", "family": "Thermal displacement", "description": "At sunrise, the camera nods down: its tilt rises, with its scale, while its rotation and its pan first dip then swing above their night level in mid-morning, and all the raw positions, references included, move together in the image; the tilt peaks in early morning, goes below its night level in late morning, then comes back to it in early afternoon, while the housing temperature rises strongly; the scale comes back more slowly, until mid-afternoon. The compensation absorbs most of it, not all: the corr_y of PB1_2 and PB2_2 rise clearly above their night level while the tilt is high and come back with it in late morning; the other targets keep nothing of it beyond the noise. Deduced cause: the mount or the lens of the camera heats up in the sun (the same remainder on PB2_2 and PB1_2 as the day before, following the tilt); according to the expert, the road hardly moves with temperature. Normal, nothing to do for the structure; the small morning rise of corr_y on PB1_2 and PB2_2 is not a movement.", "review": "2026-11-18"}
{"start": "2026-09-23T04:00Z", "end": "2026-09-23T15:15Z", "family": "Visibility", "description": "By day, from sunrise to mid-afternoon: the error_value of all sensors, references included, rises at sunrise and comes back down in the afternoon; the reference R3 is rejected almost all day, as every day (Target issue, separate label). In early morning, with the low sun, PB4 is rejected for about an hour, R2 for two measurements, and PA_9 makes small jumps. The corrected curves of the targets are more agitated than at night, isolated points of PA_9, PA3_2, PB1_2, PB2_2 and PB_5 standing out a little beyond the noise, without a step; nothing like this at night. The sun in the field at sunrise, the remainder of the camera movement on PB1_2 and PB2_2, and the vehicle passages have their own labels. Deduced cause: daytime heat shimmer above the road, which the expert gives as a trait of the station (curve noise and error_value rising by day only), and the low sun in the morning; the shimmer cannot be seen directly, the images show the scene in full daylight. The structure is not moving: do not trust the small oscillations of the day.", "review": "2026-11-18"}
{"start": "2026-09-23T08:30Z", "end": "2026-09-23T09:00Z", "family": "Obstruction", "description": "Bright reflections appear near the reference R2 on the 08:45 image, the reflections of a passing vehicle, deduced from their shape and their duration of one measurement: R1 is rejected, R2 set aside by the compensation, and the basis changes; PB4, PB_5, PB2_2 and PB1_2 jump together on corr_x or corr_y for the time of one measurement. Everything comes back at the next measurement. The structure is not moving: point to ignore.", "review": "2026-11-17"}
{"start": "2026-09-23T09:15Z", "end": "2026-09-23T09:45Z", "family": "Obstruction", "description": "The reference R1 locks onto a bright reflection, that of a passing vehicle (09:30 thumbnail, absent at 09:15): its position jumps, it is rejected and the basis changes for the time of one measurement; PB4 makes a small jump on corr_x. Everything comes back at the next measurement. The structure is not moving: point to ignore.", "review": "2026-11-17"}
{"start": "2026-09-23T13:15Z", "end": "2026-09-23T13:45Z", "family": "Obstruction", "description": "A vehicle passes in front of PB4 and the reference R2, seen as translucent on the 13:30 image: PB4 and R2 are rejected for the time of one measurement, the compensation runs without R2 and the basis changes: PA3_2 jumps a little on corr_x, PA2_2 and PB1_2 on corr_y, together, just beyond the daytime noise. Everything comes back at the next measurement. The structure is not moving: point to ignore."}
{"start": "2026-09-23T13:15Z", "end": "2026-09-23T13:45Z", "family": "Obstruction", "description": "A vehicle passes in front of PB4 and the reference R2, seen as translucent on the 13:30 image: PB4 and R2 are rejected for the time of one measurement, the compensation runs without R2 and the basis changes: PA3_2 jumps a little on corr_x, PA2_2 and PB1_2 on corr_y, together, just beyond the daytime noise. Everything comes back at the next measurement. The structure is not moving: point to ignore.", "review": "2026-11-18"}
@@ -26,7 +26,7 @@
{"start": "2026-10-01T03:15Z", "end": "2026-10-01T05:45Z", "family": "No data", "description": "No measurement for any sensor during the night, except two isolated measurements at 04:45 and 05:15 before the restart. The station shuts down for lack of energy: just before the outage, the battery is at its lowest and the voltage below its usual night level, and the metrics stop with the measurements; it restarts at sunrise with the solar charge, the compute board still cold (metrics). The curves are missing; nothing moves on the structure, but the station does not have enough energy to last the night: to be checked (battery, panel).", "review": "2026-11-17"}
{"start": "2026-10-01T04:45Z", "end": "2026-10-01T12:30Z", "family": "Thermal displacement", "description": "From sunrise until around noon, the camera moves through thermal effect, as every day: the tilt started to rise (the camera nods down) during the end-of-night outage: a little above its night level at the isolated measurement of 04:45, markedly at 06:00; it goes markedly below its level in late morning (at 10:45) and regains at 12:30 its afternoon level, a little below that of the night. The pan drops a little at sunrise (around 05:00-06:00); the rotation goes above its level around 10:00-10:30 and comes back around 12:30; at 08:30, when all the references are lost together, the pose makes a one-measurement jump (separate label); the scale rises with the temperature (markedly at 11:45) and comes back down only in the afternoon, still above its night level at 19:00. In the image, targets and references move together, as a block: y markedly positive at 06:00, then a little negative at 11:00 (ensemble.py --rigide; the targets move away from the block only barely). The housing temperature rises strongly from 04h to 07h (a little less hot at 09h, again at 11h) and stays hot at 12h: the tilt rises with the warming of the morning and comes back while the housing is still hot; the scale follows the temperature and comes back down with it. The compensation follows: on the corrected curves, the tilt wave explains little: before the loss of PA_8, barely more than the noise on each target, except PB1_2 (markedly on corr_x, over few measurements only); what remains is the daytime agitation, the steps of the loss of PA_8 and the common shift taken that day (separate labels). Cause given by the expert for this station (label of 27/09): the camera moves through thermal effect, on its lens or its mount; the road does not move with temperature. Normal, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-01T08:15Z", "end": "2026-10-01T13:15Z", "family": "Visibility", "description": "The reference PA_8 is rejected continuously from 08:30 to 13:00: the compensation runs without it, and the basis changes. PA_9, its neighbour in the image, rises markedly on corr_x and y stays on a step throughout the range; PA2_2, PA3_2, PB2_2 and PB_5 rise a little. At 08:30 and 09:15, all the references are lost together (08:30 image darker, the scene in shadow, with no obstacle): all targets jump for the time of one measurement, PA_9 especially. Everything comes back in part at 13:15, when PA_8 is taken again; PA_9 stays a little above its morning level until the evening. Cause: PA_8 poorly seen in full daylight, its spot faint on the background (14:00 thumbnail). The step is not a movement: curves of PA_9, PA2_2, PA3_2, PB2_2 and PB_5 not to be trusted over the range.", "review": "2026-11-17"}
{"start": "2026-10-01T13:00Z", "end": "2026-10-01T13:30Z", "family": "Perturbation", "description": "When the reference PA_8 is taken again, on 01/10 at 13:15, all the targets find themselves shifted from their level of late September, with the six references in the compensation: corr_y lower for all of them, together; corr_x higher for PA_9 and PA2_2, lower for PB1_2 and PB_5. The shift occurred between the night and noon, under the thermal movement of the morning and the loss of PA_8 (labelled separately): it cannot be dated more precisely. Relative to the overall movement of the targets, the references PA1_2 and PA_8 moved apart a little, mostly vertically, and R1 horizontally, whereas they followed it the evening before: the basis of references has changed a little, and all the targets inherit it together. The shift remains on 02/10 and 03/10 and fades on 04/10 (return labelled separately). Cause not established (a remainder of the camera movement poorly compensated, or a change in the appearance of these references). The shift fades on 04/10 (return labelled separately): nothing to do, do not read these days as a movement."}
{"start": "2026-10-01T13:00Z", "end": "2026-10-01T13:30Z", "family": "Perturbation", "description": "When the reference PA_8 is taken again, on 01/10 at 13:15, all the targets find themselves shifted from their level of late September, with the six references in the compensation: corr_y lower for all of them, together; corr_x higher for PA_9 and PA2_2, lower for PB1_2 and PB_5. The shift occurred between the night and noon, under the thermal movement of the morning and the loss of PA_8 (labelled separately): it cannot be dated more precisely. Relative to the overall movement of the targets, the references PA1_2 and PA_8 moved apart a little, mostly vertically, and R1 horizontally, whereas they followed it the evening before: the basis of references has changed a little, and all the targets inherit it together. The shift remains on 02/10 and 03/10 and fades on 04/10 (return labelled separately). Cause not established (a remainder of the camera movement poorly compensated, or a change in the appearance of these references). Nothing to do: do not read these days as a movement."}
{"start": "2026-10-01T13:45Z", "end": "2026-10-01T14:15Z", "family": "Visibility", "description": "The reference PA_8 is set aside again for the time of one measurement, after its long loss of the late morning (separate label): its spot is faint on the 14:00 thumbnail. The basis changes: PA2_2 and PB1_2 jump on corr_x, PA_9 and PA3_2 a little. Everything comes back at the next measurement. Cause: PA_8 poorly seen in daylight, as the same morning. The structure is not moving: point to ignore.", "review": "2026-11-18"}
{"start": "2026-10-01T21:30Z", "end": "2026-10-02T05:15Z", "family": "No data", "description": "No measurement for any sensor during the night, except one isolated measurement at 04:45. The station shuts down for lack of energy: just before the outage, the battery is at its lowest and the voltage below its usual night level, and the metrics stop with the measurements; it restarts at sunrise with the solar charge, the compute board still cold (metrics). The curves are missing; nothing moves on the structure, but the station does not have enough energy to last the night: to be checked (battery, panel).", "review": "2026-11-17"}
{"start": "2026-10-02T04:45Z", "end": "2026-10-02T13:00Z", "family": "Thermal displacement", "description": "From sunrise until around noon, the camera moves through thermal effect, as every day: its tilt (the camera nods down) is already high at the isolated measurement of 04:45, highest at 06:15, markedly above its afternoon rest; it goes markedly below this rest in late morning (at 11:30) and regains it at 13:00. The pan is a little lower than in the afternoon in the morning (around 05:15); the rotation goes markedly above its level (at 10:15) and comes back at 13:00; the scale rises with the temperature (markedly at 08:30) and comes back down in the afternoon, at its level around 17:30. In the image, targets and references move together, as a block: y markedly positive at 06:15, then a little negative at 11:30 (ensemble.py --rigide; the targets move away from the block only barely). The housing temperature rises strongly from 04h to 09h and stays hot at 13h: the tilt rises with the warming of the morning and comes back while the housing is still hot; the scale follows the temperature and comes back down with it. The compensation follows: on the corrected curves, the tilt wave explains little, apart from the steps of the loss of PA_8 (from 06:00 to 13:00) and of the first measurements without PA1_2 or PA_8, which make the targets jump; these episodes and the daytime agitation are labelled separately. Cause given by the expert for this station (label of 27/09): the camera moves through thermal effect, on its lens or its mount; the road does not move with temperature. Normal, nothing to do.", "review": "2026-11-17"}
@@ -7,7 +7,7 @@
{"start": "2026-10-08T14:00Z", "end": "2026-10-08T14:30Z", "family": "Visibility", "description": "At 14:15, the image is very dark (thumbnails of R1, R2 and PB4 almost black): R1 and R2 are set aside, PA3_2 and PB4 rejected, and the basis changes for the time of one measurement; PB_5, PB1_2 and PB2_2 jump together, then come back at the next measurement. Cause: a capture that is too dark. The structure is not moving: point to ignore.", "review": "2026-11-17"}
{"start": "2026-10-08T14:30Z", "end": "2026-10-08T15:00Z", "family": "Visibility", "description": "At 14:45, again a very dark image: R1 and R2 are set aside, and PB4, PA3_2, PB_5 and PB1_2 jump together for the time of one measurement, then come back. Cause: a capture that is too dark, as at 14:15. The structure is not moving: point to ignore.", "review": "2026-11-17"}
{"start": "2026-10-08T16:00Z", "end": "2026-10-09T05:00Z", "family": "No data", "description": "No measurement for any sensor during the night. The station shuts down for lack of energy: just before the outage, the battery is at its lowest and the voltage below its usual night level, and the metrics stop with the measurements; it restarts at sunrise with the solar charge, the compute board still cold (metrics). The curves are missing; nothing moves on the structure, but the station does not have enough energy to last the night: to be checked (battery, panel).", "review": "2026-11-17"}
{"start": "2026-10-09T05:00Z", "end": "2026-10-09T12:30Z", "family": "Visibility", "description": "At sunrise, the compensation loses its references: none is retained from 05:00 to 05:30 (PA1_2, PA_8, R1 and R2 rejected or set aside, R3 rejected as every day), only three at 05:45 and four at 06:00. PA3_2, PA_9, PB4 and PB_5 are rejected; the targets still measured, PA2_2, PB1_2 and PB2_2, jump clearly on corr_x and corr_y, PA2_2 the most, and come back once the references are retained again, from 06:15. Later in the morning, the references PA1_2 and PA_8 drop out at times; at 09:45, without PA_8, PA2_2 jumps again on corr_x, just at the edge of the noise, for the time of one measurement. The rest of the day, the corrected curves are agitated but stay within their noise; the passages of 09:30 and 12:00 are apart. The measurements stop at 12:30. Cause: the low sun at sunrise and the daylight on the scene, which make the reference spots hard to find, as on the other mornings of this station; the images show the scene in full daylight. The jumps come from the change of references, not from the structure: points not to be trusted at sunrise."}
{"start": "2026-10-09T05:00Z", "end": "2026-10-09T12:30Z", "family": "Visibility", "description": "At sunrise, the compensation loses its references: none is retained from 05:00 to 05:30 (PA1_2, PA_8, R1 and R2 rejected or set aside, R3 rejected as every day), only three at 05:45 and four at 06:00. PA3_2, PA_9, PB4 and PB_5 are rejected; the targets still measured, PA2_2, PB1_2 and PB2_2, jump clearly on corr_x and corr_y, PA2_2 the most, and come back once the references are retained again, from 06:15. Later in the morning, the references PA1_2 and PA_8 drop out at times; at 09:45, without PA_8, PA2_2 jumps again on corr_x, just at the edge of the noise, for the time of one measurement. The rest of the day, the corrected curves are agitated but stay within their noise; the passages of 09:30 and 12:00 are apart. The measurements stop at 12:30. Cause: the low sun at sunrise and the daylight on the scene, which make the reference spots hard to find, as on the other mornings of this station; the images show the scene in full daylight. The jumps come from the change of references, not from the structure: points not to be trusted at sunrise.", "review": "2026-11-18"}
{"start": "2026-10-09T11:45Z", "end": "2026-10-09T12:15Z", "family": "Obstruction", "description": "Bright vehicle reflections appear near PA3_2 and PB4 (12:00 thumbnails, absent at 11:45): having stayed under the threshold, they lock onto them and their corr_x, corr_y make a huge jump for the time of one measurement; the reference R2 is set aside. Everything comes back at the next measurement. The structure is not moving: these points are false, to ignore.", "review": "2026-11-17"}
{"start": "2026-10-09T12:30Z", "end": "2026-10-15T08:00Z", "family": "No data", "description": "No measurement for any sensor for nearly six days. Until the early morning of 13/10, the station is mute: no metrics and no images, although the battery was not low just before (metrics of 09/10 at noon), so this is not the outage of each night. From 13/10, the metrics come back, the battery full and stable at night, and daytime images arrive every hour, but still no displacement measurement. Cause not established (station stopped, then measurement that does not restart; an intervention is possible). The curves are missing: to be checked with the operator.", "review": "2026-11-17"}
{"start": "2026-10-15T07:45Z", "end": "2026-10-15T08:15Z", "family": "Obstruction", "description": "A single measurement, in the middle of the outage, at 08:00: five of the six references are rejected (PA1_2, PA_8, PB3_2, R2, R3); R1 alone is kept, so the compensation can only remove a translation and the camera is not properly recalibrated. PA2_2, PA3_2, PB2_2 and PB4 are rejected; PA_9, PB1_2 and PB_5 keep a point, clearly far from their level in corr_y. Their raw positions show the whole scene shifted downward by a large step since the last measurements of 09/10: the camera moved during the outage, cause not established (an intervention is possible). The 08:00 image shows translucent blurry trails on the pavement and the road, like the passages seen on the other days. Probable cause of the rejections: a passage in front of the scene, on top of the shifted camera. With a single reference, these points are meaningless: points to ignore; the camera position is to be checked with the operator."}
{"start": "2026-10-15T07:45Z", "end": "2026-10-15T08:15Z", "family": "Obstruction", "description": "A single measurement, in the middle of the outage, at 08:00: five of the six references are rejected (PA1_2, PA_8, PB3_2, R2, R3); R1 alone is kept, so the compensation can only remove a translation and the camera is not properly recalibrated. PA2_2, PA3_2, PB2_2 and PB4 are rejected; PA_9, PB1_2 and PB_5 keep a point, clearly far from their level in corr_y. Their raw positions show the whole scene shifted downward by a large step since the last measurements of 09/10: the camera moved during the outage, cause not established (an intervention is possible). The 08:00 image shows translucent blurry trails on the pavement and the road, like the passages seen on the other days. Probable cause of the rejections: a passage in front of the scene, on top of the shifted camera. With a single reference, these points are meaningless: points to ignore; the camera position is to be checked with the operator.", "review": "2026-11-18"}