Fixes of the final review: families.md gives one answer for an unexplained movement that returns (Perturbation); NORDEND-257 keeps its hypotheses next to "not established"

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
maximeandClaude Opus 5.5 committed 2026-11-18 10:41:17 +01:00
1 parent 82edc98a29
commit fed05a7d10
3 files changed
+3 -3

No files matched your search

+1 -1
View File
@@ -108,7 +108,7 @@
{"id": "NORDEND-99", "start": "2026-09-07T05:30Z", "end": "2026-09-08T06:45Z", "family": "Thermal displacement", "description": "Thermal cycle of the camera, poorly compensated. In the morning, when the housing heats up strongly, the camera turns all at once (tilt rising, pan dropping, scale changing); the raw positions of all the targets and references move together. The compensation does not erase everything: the corr_x of PR18, PR16, PR15 and PR14 drops strongly, the corr_y of PR18 rises, then the curves come back in the afternoon; the camera then comes back slowly, in the evening, then only very little at night, until the start of the next morning. Deduced cause: the pose follows the housing temperature, and the rock face of the quarry cannot move with the temperature. This is not a movement of the structure: nothing to do.", "review": "2026-11-17", "analysis": "NORDEND_2026-09-04T0615_2026-09-17T0545"}
{"id": "NORDEND-100", "start": "2026-09-08T00:45Z", "end": "2026-09-08T01:15Z", "family": "No data", "description": "One measurement is missing for all the sensors, at night: all the curves have a gap. The image of that instant exists, the station synchronised at that instant (last_sync) and its voltage is normal: the station is running, the measurement of that instant is missing from the data. JUNGFRAU (which loses the previous measurement) and WILDSTRUBEL measure at that instant: gap specific to the station, cause not established. The curves resume at the next measurement: nothing to do.", "review": "2026-11-17", "analysis": "NORDEND_2026-09-04T0615_2026-09-17T0545"}
{"id": "NORDEND-256", "start": "2026-09-08T01:45Z", "end": "2026-09-08T02:45Z", "family": "Visibility", "description": "At night, PR07 is rejected for two measurements: its curve is missing; at the same time PR16 jumps on corr_x and corr_y, and PR15 a little on corr_x, then they come back at the measurement that follows the rejections. The 02:00 image is very noisy and the weak spot of PR07 is lost in it. Points to ignore, nothing to do.", "review": "2026-11-18", "analysis": "NORDEND_2026-09-04T0615_2026-09-17T0545"}
{"id": "NORDEND-257", "start": "2026-09-08T05:30Z", "end": "2026-09-08T08:15Z", "family": "Perturbation", "description": "Early in the morning, the corr_x of PR07 alone drops below its level, a little at first, then clearly for more than an hour, without rejection, and comes back gradually; its corr_y rises a little and its error_value rises at the same time, without reaching the threshold. The other targets do not follow it. Its spot is weak on the 07:00 thumbnail, without visible obstacle. Cause not established; the curve comes back by itself the same morning: nothing to do, points to ignore.", "analysis": "NORDEND_2026-09-04T0615_2026-09-17T0545"}
{"id": "NORDEND-257", "start": "2026-09-08T05:30Z", "end": "2026-09-08T08:15Z", "family": "Perturbation", "description": "Early in the morning, the corr_x of PR07 alone drops below its level, a little at first, then clearly for more than an hour, without rejection, and comes back gradually; its corr_y rises a little and its error_value rises at the same time, without reaching the threshold. The other targets do not follow it. Its spot is weak on the 07:00 thumbnail, without visible obstacle. Cause not established (a weakened spot, or a brief movement of PR07 itself); the curve comes back by itself the same morning: nothing to do, points to ignore.", "analysis": "NORDEND_2026-09-04T0615_2026-09-17T0545"}
{"id": "NORDEND-103", "start": "2026-09-08T06:45Z", "end": "2026-09-09T06:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the camera, poorly compensated. In the morning, when the housing heats up, the camera turns gradually (tilt rising, pan dropping, scale changing); the raw positions of all the targets and references move together. The compensation does not erase everything: the corr_x of PR18 drops a little, the corr_y of PR18 hardly moves, then the curves come back in the afternoon; the camera then comes back slowly, in the evening and all night (the pan rises again), until the start of the next morning. In early evening, when the pose starts moving again, several targets move a little for one measurement. Deduced cause: the pose follows the housing temperature, and the rock face of the quarry cannot move with the temperature. This is not a movement of the structure: nothing to do.", "review": "2026-11-17", "analysis": "NORDEND_2026-09-04T0615_2026-09-17T0545"}
{"id": "NORDEND-105", "start": "2026-09-09T06:00Z", "end": "2026-09-10T04:30Z", "family": "Thermal displacement", "description": "Thermal cycle of the camera, poorly compensated. In the morning, when the housing heats up, the camera turns all at once (tilt rising, pan dropping, scale changing); the raw positions of all the targets and references move together. The compensation does not erase everything: the corr_x of PR18, PR16, PR15 and PR14 drops markedly, the corr_y of PR18 rises, then the curves come back in the afternoon; the camera then comes back slowly, in the evening and all night (the pan rises again), until the start of the next morning. Deduced cause: the pose follows the housing temperature, and the rock face of the quarry cannot move with the temperature. This is not a movement of the structure: nothing to do.", "review": "2026-11-17", "analysis": "NORDEND_2026-09-04T0615_2026-09-17T0545"}
{"id": "NORDEND-258", "start": "2026-09-09T14:45Z", "end": "2026-09-09T16:00Z", "family": "Visibility", "description": "CTR01 (local reference, treated as a target) is rejected for two measurements in a row in the afternoon: its corr_x and corr_y curves are missing. Deduced cause: same hour and same signature as the other sunny afternoons, where the thumbnails show the rock in full sun around the target and the spot drowning in it (16/08, 21 and 22/09). At the second of them, the error_value of almost all the sensors rises and several targets move a little: PR18, PR15 and PR08 on corr_y, PR14, PR05 and PR01 on corr_x, most for one measurement, PR08 and PR15 coming back on corr_y only half an hour later. The other targets remain measured. The structure does not move: nothing to do, CTR01's curve is missing on sunny afternoons.", "review": "2026-11-18", "analysis": "NORDEND_2026-09-04T0615_2026-09-17T0545"}
@@ -12,7 +12,7 @@
{"start": "2026-09-07T05:30Z", "end": "2026-09-08T06:45Z", "family": "Thermal displacement", "description": "Thermal cycle of the camera, poorly compensated. In the morning, when the housing heats up strongly, the camera turns all at once (tilt rising, pan dropping, scale changing); the raw positions of all the targets and references move together. The compensation does not erase everything: the corr_x of PR18, PR16, PR15 and PR14 drops strongly, the corr_y of PR18 rises, then the curves come back in the afternoon; the camera then comes back slowly, in the evening, then only very little at night, until the start of the next morning. Deduced cause: the pose follows the housing temperature, and the rock face of the quarry cannot move with the temperature. This is not a movement of the structure: nothing to do.", "review": "2026-11-17"}
{"start": "2026-09-08T00:45Z", "end": "2026-09-08T01:15Z", "family": "No data", "description": "One measurement is missing for all the sensors, at night: all the curves have a gap. The image of that instant exists, the station synchronised at that instant (last_sync) and its voltage is normal: the station is running, the measurement of that instant is missing from the data. JUNGFRAU (which loses the previous measurement) and WILDSTRUBEL measure at that instant: gap specific to the station, cause not established. The curves resume at the next measurement: nothing to do.", "review": "2026-11-17"}
{"start": "2026-09-08T01:45Z", "end": "2026-09-08T02:45Z", "family": "Visibility", "description": "At night, PR07 is rejected for two measurements: its curve is missing; at the same time PR16 jumps on corr_x and corr_y, and PR15 a little on corr_x, then they come back at the measurement that follows the rejections. The 02:00 image is very noisy and the weak spot of PR07 is lost in it. Points to ignore, nothing to do.", "review": "2026-11-18"}
{"start": "2026-09-08T05:30Z", "end": "2026-09-08T08:15Z", "family": "Perturbation", "description": "Early in the morning, the corr_x of PR07 alone drops below its level, a little at first, then clearly for more than an hour, without rejection, and comes back gradually; its corr_y rises a little and its error_value rises at the same time, without reaching the threshold. The other targets do not follow it. Its spot is weak on the 07:00 thumbnail, without visible obstacle. Cause not established; the curve comes back by itself the same morning: nothing to do, points to ignore."}
{"start": "2026-09-08T05:30Z", "end": "2026-09-08T08:15Z", "family": "Perturbation", "description": "Early in the morning, the corr_x of PR07 alone drops below its level, a little at first, then clearly for more than an hour, without rejection, and comes back gradually; its corr_y rises a little and its error_value rises at the same time, without reaching the threshold. The other targets do not follow it. Its spot is weak on the 07:00 thumbnail, without visible obstacle. Cause not established (a weakened spot, or a brief movement of PR07 itself); the curve comes back by itself the same morning: nothing to do, points to ignore."}
{"start": "2026-09-08T06:45Z", "end": "2026-09-09T06:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the camera, poorly compensated. In the morning, when the housing heats up, the camera turns gradually (tilt rising, pan dropping, scale changing); the raw positions of all the targets and references move together. The compensation does not erase everything: the corr_x of PR18 drops a little, the corr_y of PR18 hardly moves, then the curves come back in the afternoon; the camera then comes back slowly, in the evening and all night (the pan rises again), until the start of the next morning. In early evening, when the pose starts moving again, several targets move a little for one measurement. Deduced cause: the pose follows the housing temperature, and the rock face of the quarry cannot move with the temperature. This is not a movement of the structure: nothing to do.", "review": "2026-11-17"}
{"start": "2026-09-09T06:00Z", "end": "2026-09-10T04:30Z", "family": "Thermal displacement", "description": "Thermal cycle of the camera, poorly compensated. In the morning, when the housing heats up, the camera turns all at once (tilt rising, pan dropping, scale changing); the raw positions of all the targets and references move together. The compensation does not erase everything: the corr_x of PR18, PR16, PR15 and PR14 drops markedly, the corr_y of PR18 rises, then the curves come back in the afternoon; the camera then comes back slowly, in the evening and all night (the pan rises again), until the start of the next morning. Deduced cause: the pose follows the housing temperature, and the rock face of the quarry cannot move with the temperature. This is not a movement of the structure: nothing to do.", "review": "2026-11-17"}
{"start": "2026-09-09T14:45Z", "end": "2026-09-09T16:00Z", "family": "Visibility", "description": "CTR01 (local reference, treated as a target) is rejected for two measurements in a row in the afternoon: its corr_x and corr_y curves are missing. Deduced cause: same hour and same signature as the other sunny afternoons, where the thumbnails show the rock in full sun around the target and the spot drowning in it (16/08, 21 and 22/09). At the second of them, the error_value of almost all the sensors rises and several targets move a little: PR18, PR15 and PR08 on corr_y, PR14, PR05 and PR01 on corr_x, most for one measurement, PR08 and PR15 coming back on corr_y only half an hour later. The other targets remain measured. The structure does not move: nothing to do, CTR01's curve is missing on sunny afternoons.", "review": "2026-11-18"}
+1 -1
View File
@@ -31,7 +31,7 @@ For the client, some varieties of a family (the `label` of the detectors' episod
- **Obstruction, whatever the duration**: an obstacle that stays (parked vehicle, machine, plant, animal or insects against the lens, mark on the glass in front of a single spot) is Obstruction.
- **A hindered reference** (phenomena: "A reference dropped", "Two references lost"): the family of its cause. A passage in front of a reference that makes the base jump is Obstruction when the object is seen, or deduced from a passage signature; a reference right at its threshold, with nothing in front of it, is not a passage: Visibility, or Perturbation without a cause; Displacement if the base stays changed. The description says it is a reference, and that the targets move together because of it.
- **A jump then the return**: the family of its cause, seen on the images. A passing vehicle, and its reflection, are Obstruction (a reflection on the roadway lasting only one measurement is a vehicle: read the measurement before and the one after); the reflection of the sun on the fixed scene is Visibility. Without an established cause: Perturbation.
- **Thermal displacement or Displacement**: what follows the temperature of the housing **and comes back with it** (same position at equal temperature), even over several days, or whose thermal cause the expert gives, is Thermal displacement; what follows it only as a trend, without coming back at equal temperature, and what the temperature does not explain, are Displacement. What does not follow it and comes back is Perturbation.
- **Thermal displacement or Displacement**: what follows the temperature of the housing **and comes back with it** (same position at equal temperature), even over several days, or whose thermal cause the expert gives, is Thermal displacement; what follows it only as a trend, without coming back at equal temperature, and what the temperature does not explain and does not come back, are Displacement. What does not follow it and comes back is Perturbation.
- **Displacement or Perturbation**: decided by the return, not by the cause. What moved and has not come back by the end of the range (a target, a reference, the camera outside a thermal effect) is Displacement; what comes back, even after days, is Perturbation. A camera that moves and stays is Displacement even when the compensation absorbs it afterwards; the description says it is the camera. A partial return is not a return.
- **Thermal displacement or Visibility**: curves that follow the scale and rotation of the camera with the housing temperature, the `error_value` at its level or rising only a little, nothing on the images, several targets moving apart in opposite directions through the rest of the compensation, are Thermal displacement. References moving apart from each other and from the targets, an `error_value` rising on most sensors, an episode with sharp edges, or a nuisance seen on the images, are Visibility, even at the temperature trough. The two can coexist: two labels. A daytime agitation, the pose shaking without the `error_value` rising, is not turbulence.
- **A gap**: curves missing because targets are rejected are not labeled for themselves, the station filtered them; the episode that rejects them is labeled only if it moves the other curves beyond the noise, in the family of its cause (Visibility, Obstruction); a target rejected almost always is a Target issue; all curves missing, no measurement: No data. The cause of a No data can be outside the station: a gap at the same minutes on several stations is a common cause (transmission or reception), not an outage. The station is running if a synchronization falls at the missing instant, if the image of that instant exists, or if `DB_not_uploaded` rises then falls.