auto: CLARIDEN-12 and MICHIGAN-19 no longer point to labels that do not exist, WILDSTRUBEL-136 no longer repeats its return (review removed on the reworded CLARIDEN-12 and MICHIGAN-19); the analysis copies of the reviews aimsight-app wrote in the 9 stations committed in 9ccd04d, and the removal of WILDSTRUBEL-70's copy, so that each copy matches its final label at HEAD
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
1 parent
fed05a7d10
commit
de092c8008
17 files changed
+68
-69
No files matched your search
@@ -12,7 +12,7 @@
|
||||
{"start": "2026-10-27T09:00Z", "end": "2026-10-27T09:30Z", "family": "No data", "description": "One measurement absent for all sensors; normal voltage around it. The same gap falls at the same moment on the other stations measuring at that time (CLARIDEN, JUNGFRAU, LENZSPITZE, NORDEND): a common cause outside the station (transmission or reception of the data), not a failure of the station; it is not established. The curves are missing over the range; nothing to do on the station.", "review": "2026-11-17"}
|
||||
{"start": "2026-10-27T11:30Z", "end": "2026-10-27T20:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day; the corr_x of Sellette 6 goes down clearly in the afternoon, that of Sellette 5 a little, the corr_y of Sellette 5 rises a little, and everything returns in the evening. Deduced: the camera movement follows the housing temperature, ordinary error_value outside the other episodes. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-17"}
|
||||
{"start": "2026-10-28T07:00Z", "end": "2026-10-28T10:30Z", "family": "Visibility", "description": "r1_r, one of the only two references of the station, sees its error_value rise above the threshold in the morning, one measurement then nine, after a slow rise of its error_value all night: it is rejected and the camera is no longer registered. The corrected curves are then computed on p1_r alone: the corr_x of Sellette 5 and Sellette 4 (and of Sellette 6 at the first loss) jump a little and return at the next registration. Pont Ernen, the twin of r1_r, leaves its usual zero when it is not rejected too. Raw positions of the targets without a step. Same scenario as the previous mornings; cause not established. With a single reference, no measurement is possible: data of the range not to be trusted; this is not a movement. If it repeats, check the prism r1_r.", "review": "2026-11-17"}
|
||||
{"start": "2026-10-28T10:15Z", "end": "2026-10-28T19:45Z", "family": "Thermal displacement", "description": "Thermal cycle of the day, small: with the clear rise of the housing temperature in the morning, the camera pose turns (mostly the rotation, the tilt a little, the pan hardly moves) until the early afternoon, then returns in the late afternoon; the corr_y of Sellette 5 rises during the day and comes back toward its night level in the evening, the corr_x of Sellette 5 and Sellette 4 rise a little with it. The start is hidden under the loss of r1_r of the morning (separate label); the pose has already turned at the first registration after it. Deduced: the pose and the curves follow the housing temperature and come back with it, error_value at its level, the references calm. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do."}
|
||||
{"start": "2026-10-28T10:15Z", "end": "2026-10-28T19:45Z", "family": "Thermal displacement", "description": "Thermal cycle of the day, small: with the clear rise of the housing temperature in the morning, the camera pose turns (mostly the rotation, the tilt a little, the pan hardly moves) until the early afternoon, then returns in the late afternoon; the corr_y of Sellette 5 rises during the day and comes back toward its night level in the evening, the corr_x of Sellette 5 and Sellette 4 rise a little with it. The start is hidden under the loss of r1_r of the morning (separate label); the pose has already turned at the first registration after it. Deduced: the pose and the curves follow the housing temperature and come back with it, error_value at its level, the references calm. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-18"}
|
||||
{"start": "2026-10-29T06:45Z", "end": "2026-10-29T18:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day; the corr_y of Sellette 5 rises during the day and returns in the evening. Deduced: the camera movement follows the housing temperature, ordinary error_value outside the other episodes. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-17"}
|
||||
{"start": "2026-10-30T07:45Z", "end": "2026-10-30T19:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day; the corr_y of Sellette 5 rises during the day and returns in the evening. Deduced: the camera movement follows the housing temperature, ordinary error_value outside the other episodes. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-17"}
|
||||
{"start": "2026-10-31T06:45Z", "end": "2026-10-31T19:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day; the corr_y of Sellette 5 rises during the day and returns in the evening. Deduced: the camera movement follows the housing temperature, ordinary error_value outside the other episodes. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-17"}
|
||||
Reference in new issue