auto: CLARIDEN-12 and MICHIGAN-19 no longer point to labels that do not exist, WILDSTRUBEL-136 no longer repeats its return (review removed on the reworded CLARIDEN-12 and MICHIGAN-19); the analysis copies of the reviews aimsight-app wrote in the 9 stations committed in 9ccd04d, and the removal of WILDSTRUBEL-70's copy, so that each copy matches its final label at HEAD
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
1 parent
fed05a7d10
commit
de092c8008
17 files changed
+68
-69
No files matched your search
@@ -17,12 +17,12 @@
|
||||
{"start": "2026-08-19T20:15Z", "end": "2026-08-20T03:45Z", "family": "Visibility", "description": "Cobweb night: on the 22:00 and 02:00 images, very noisy, a lit blurred band crosses the top of the group of targets and blurred discs are at the bottom left. CTR01 is rejected all night, PR07 for a few measurements; the corr_x of PR07 jumps at the start of the night and that of PR08 departs in the second half of the night. The range is cut by measurement gaps (labelled separately). The structure does not move: do not trust these curves over the range.", "review": "2026-11-17"}
|
||||
{"start": "2026-08-19T20:30Z", "end": "2026-08-19T21:00Z", "family": "No data", "description": "One measurement is missing for all the sensors, just after the resumption from the afternoon gap: all the curves have a gap. The image is missing too, but the station synchronised at that instant (last_sync) and its voltage is normal. No other station has data on that date to compare; cause not established. The curves resume at the next measurement: nothing to do.", "review": "2026-11-17"}
|
||||
{"start": "2026-08-20T00:30Z", "end": "2026-08-20T01:00Z", "family": "No data", "description": "One measurement is missing for all the sensors, at night: all the curves have a gap. The image of that instant is missing too, but the station synchronised at that instant (last_sync) and its voltage is normal. No other station has data on that date to compare; cause not established. A gap of one or two measurements comes back around the same hour on many nights of the range. The curves resume at the next measurement: nothing to do.", "review": "2026-11-17"}
|
||||
{"start": "2026-08-20T03:45Z", "end": "2026-08-20T06:15Z", "family": "No data", "description": "No measurement at the end of the night, for a few hours: all the curves are missing from 04:00 to 06:00. The images and the system metrics are missing too from 04:00; the voltage is normal before and after. The image and a synchronisation (last_sync) come back at 06:00, one acquisition before the first measurement (06:15): at that instant the station is running and only the measurement is missing. No other station has data on that date to compare; cause not established. The curves resume without any offset of their own (the pose started with the morning, in the thermal cycle labelled separately): nothing to do."}
|
||||
{"start": "2026-08-20T03:45Z", "end": "2026-08-20T06:15Z", "family": "No data", "description": "No measurement at the end of the night, for a few hours: all the curves are missing from 04:00 to 06:00. The images and the system metrics are missing too from 04:00; the voltage is normal before and after. The image and a synchronisation (last_sync) come back at 06:00, one acquisition before the first measurement (06:15): at that instant the station is running and only the measurement is missing. No other station has data on that date to compare; cause not established. The curves resume without any offset of their own (the pose started with the morning, in the thermal cycle labelled separately): nothing to do.", "review": "2026-11-18"}
|
||||
{"start": "2026-08-20T06:15Z", "end": "2026-08-21T05:15Z", "family": "Thermal displacement", "description": "Thermal cycle of the camera, poorly compensated. The start of the morning falls in a measurement gap (labelled separately): when measurements resume, the pose has already moved (tilt up, pan down). The raw positions of all the targets and references move together; the compensation does not erase everything, the corr_x of PR18 and PR16 drops a little, then comes back in the afternoon; the camera then comes back slowly, in the evening and all night (the pan rises, the corr_x of PR18 too), until the start of the next morning. Deduced cause: the pose follows the housing temperature, and the rock face of the quarry cannot move with the temperature. This is not a movement of the structure: nothing to do.", "review": "2026-11-17"}
|
||||
{"start": "2026-08-20T08:00Z", "end": "2026-08-20T09:00Z", "family": "No data", "description": "Three measurements in a row are missing for all the sensors in the morning, the images too, with no synchronisation at those instants; the hourly metrics are there and the voltage is normal. No other station has data on that date to compare; cause not established. The curves then resume: nothing to do.", "review": "2026-11-17"}
|
||||
{"start": "2026-08-20T16:15Z", "end": "2026-08-20T17:15Z", "family": "Visibility", "description": "The sun reaches the wall in late afternoon (16:15, 16:30, 16:45 thumbnails): PR07 disappears and is rejected for one measurement, the corr_x of PR14, PR15 and PR16 jumps for the time of this measurement, PR05 and PR08 a little at the next, then everything comes back. Points to ignore, nothing to do.", "review": "2026-11-17"}
|
||||
{"start": "2026-08-21T00:30Z", "end": "2026-08-21T01:15Z", "family": "No data", "description": "Two measurements in a row are missing for all the sensors, at night: all the curves have a gap, the images are missing too; the station synchronised at the start of the gap (last_sync) and its voltage is normal. No other station has data on that date to compare; cause not established. A gap of one or two measurements comes back around the same hour on many nights of the range. The curves then resume: nothing to do.", "review": "2026-11-17"}
|
||||
{"start": "2026-08-21T05:15Z", "end": "2026-08-22T06:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the camera, poorly compensated. In the morning, when the housing heats up, the camera turns all at once (tilt rising, pan dropping, scale changing); the raw positions of all the targets and references move together. The compensation does not erase everything: the corr_x of PR18 drops markedly, the corr_y of PR18 rises, then the curves come back in the afternoon; the camera then comes back slowly, in the evening, then only very little at night, until the start of the next morning. In the evening and at night, the cobweb (labelled separately) makes its own jumps. Deduced cause: the pose follows the housing temperature, and the rock face of the quarry cannot move with the temperature. This is not a movement of the structure: nothing to do.", "review": "2026-11-17"}
|
||||
{"start": "2026-08-21T15:45Z", "end": "2026-08-22T07:30Z", "family": "Visibility", "description": "A cobweb settles in front of the lens in late afternoon: blurred bands are already visible by day (16:45 image), then at night as wide lit bands covering a large part of the scene (18:15, 19:15, 20:30, 03:00); the image becomes sharp again in the morning (07:30). PR07 is rejected from 16:00, CTR01 all night; at dusk, most of the targets are rejected at the same time and the corrected curves of the others jump in both directions; PR08 stays offset on corr_x until the morning. The structure does not move: do not trust the curves over the range, nothing to do.", "review": "2026-11-17"}
|
||||
{"start": "2026-08-22T06:00Z", "end": "2026-08-23T05:15Z", "family": "Thermal displacement", "description": "Thermal cycle of the camera, poorly compensated. In the morning, when the housing heats up, the camera turns all at once (tilt rising, pan dropping, scale changing); the raw positions of all the targets and references move together. The compensation does not erase everything: the corr_x of PR18, PR14, PR16 and PR15 drops markedly, the corr_y of PR18 rises, then the curves come back in the afternoon; the camera then comes back slowly, in the evening and all night (the pan rises again), until the start of the next morning. The following night is the coldest of the batch: as the housing temperature keeps falling, the camera keeps turning (scale dropping, rotation and pan rising), the registration error rises, and the reference CTR04 slides a little downward against the targets while CTR02 slides the other way; through the compensation, the corr_y of most targets rises a little and stays up from midnight to the end of the night (PR15, PR07, PR10, PR06, PR14, PR16 above all, and the reference CTR02, while CTR03 goes down), then comes back as the housing warms up in the next morning. The targets do not move relative to each other, their error_value stays at its level, and the reference thumbnails show sharp spots, although lit cobweb threads cross the image all night (20:00 and 03:00 images). Deduced cause: the pose follows the housing temperature, and the rock face of the quarry cannot move with the temperature. This is not a movement of the structure: nothing to do."}
|
||||
{"start": "2026-08-22T06:00Z", "end": "2026-08-23T05:15Z", "family": "Thermal displacement", "description": "Thermal cycle of the camera, poorly compensated. In the morning, when the housing heats up, the camera turns all at once (tilt rising, pan dropping, scale changing); the raw positions of all the targets and references move together. The compensation does not erase everything: the corr_x of PR18, PR14, PR16 and PR15 drops markedly, the corr_y of PR18 rises, then the curves come back in the afternoon; the camera then comes back slowly, in the evening and all night (the pan rises again), until the start of the next morning. The following night is the coldest of the batch: as the housing temperature keeps falling, the camera keeps turning (scale dropping, rotation and pan rising), the registration error rises, and the reference CTR04 slides a little downward against the targets while CTR02 slides the other way; through the compensation, the corr_y of most targets rises a little and stays up from midnight to the end of the night (PR15, PR07, PR10, PR06, PR14, PR16 above all, and the reference CTR02, while CTR03 goes down), then comes back as the housing warms up in the next morning. The targets do not move relative to each other, their error_value stays at its level, and the reference thumbnails show sharp spots, although lit cobweb threads cross the image all night (20:00 and 03:00 images). Deduced cause: the pose follows the housing temperature, and the rock face of the quarry cannot move with the temperature. This is not a movement of the structure: nothing to do.", "review": "2026-11-18"}
|
||||
{"start": "2026-08-22T16:30Z", "end": "2026-08-22T17:00Z", "family": "No data", "description": "One measurement is missing for all the sensors in late afternoon; the image of that instant exists. The system metrics are missing for several hours from that hour, then the entries waiting to be sent (DB_not_uploaded) accumulate until the next morning before being sent: the station is running, the sending of its data is hindered. According to the data documentation, FLORIDA and MISSISSIPPI also have a gap on the same day around the same hour (their data for this date are not in the folder): a common cause outside the station (transmission or reception of the data), not a station failure; it is not established. The curves resume at the next measurement: nothing to do on the station.", "review": "2026-11-17"}
|
||||
Reference in new issue