auto: CLARIDEN-12 and MICHIGAN-19 no longer point to labels that do not exist, WILDSTRUBEL-136 no longer repeats its return (review removed on the reworded CLARIDEN-12 and MICHIGAN-19); the analysis copies of the reviews aimsight-app wrote in the 9 stations committed in 9ccd04d, and the removal of WILDSTRUBEL-70's copy, so that each copy matches its final label at HEAD

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
maximeandClaude Opus 5.5 committed 2026-11-18 10:45:57 +01:00
1 parent fed05a7d10
commit de092c8008
17 files changed
+68 -69

No files matched your search

@@ -7,7 +7,7 @@
{"start": "2026-10-08T14:00Z", "end": "2026-10-08T14:30Z", "family": "Visibility", "description": "At 14:15, the image is very dark (thumbnails of R1, R2 and PB4 almost black): R1 and R2 are set aside, PA3_2 and PB4 rejected, and the basis changes for the time of one measurement; PB_5, PB1_2 and PB2_2 jump together, then come back at the next measurement. Cause: a capture that is too dark. The structure is not moving: point to ignore.", "review": "2026-11-17"}
{"start": "2026-10-08T14:30Z", "end": "2026-10-08T15:00Z", "family": "Visibility", "description": "At 14:45, again a very dark image: R1 and R2 are set aside, and PB4, PA3_2, PB_5 and PB1_2 jump together for the time of one measurement, then come back. Cause: a capture that is too dark, as at 14:15. The structure is not moving: point to ignore.", "review": "2026-11-17"}
{"start": "2026-10-08T16:00Z", "end": "2026-10-09T05:00Z", "family": "No data", "description": "No measurement for any sensor during the night. The station shuts down for lack of energy: just before the outage, the battery is at its lowest and the voltage below its usual night level, and the metrics stop with the measurements; it restarts at sunrise with the solar charge, the compute board still cold (metrics). The curves are missing; nothing moves on the structure, but the station does not have enough energy to last the night: to be checked (battery, panel).", "review": "2026-11-17"}
{"start": "2026-10-09T05:00Z", "end": "2026-10-09T12:30Z", "family": "Visibility", "description": "At sunrise, the compensation loses its references: none is retained from 05:00 to 05:30 (PA1_2, PA_8, R1 and R2 rejected or set aside, R3 rejected as every day), only three at 05:45 and four at 06:00. PA3_2, PA_9, PB4 and PB_5 are rejected; the targets still measured, PA2_2, PB1_2 and PB2_2, jump clearly on corr_x and corr_y, PA2_2 the most, and come back once the references are retained again, from 06:15. Later in the morning, the references PA1_2 and PA_8 drop out at times; at 09:45, without PA_8, PA2_2 jumps again on corr_x, just at the edge of the noise, for the time of one measurement. The rest of the day, the corrected curves are agitated but stay within their noise; the passages of 09:30 and 12:00 are apart. The measurements stop at 12:30. Cause: the low sun at sunrise and the daylight on the scene, which make the reference spots hard to find, as on the other mornings of this station; the images show the scene in full daylight. The jumps come from the change of references, not from the structure: points not to be trusted at sunrise."}
{"start": "2026-10-09T05:00Z", "end": "2026-10-09T12:30Z", "family": "Visibility", "description": "At sunrise, the compensation loses its references: none is retained from 05:00 to 05:30 (PA1_2, PA_8, R1 and R2 rejected or set aside, R3 rejected as every day), only three at 05:45 and four at 06:00. PA3_2, PA_9, PB4 and PB_5 are rejected; the targets still measured, PA2_2, PB1_2 and PB2_2, jump clearly on corr_x and corr_y, PA2_2 the most, and come back once the references are retained again, from 06:15. Later in the morning, the references PA1_2 and PA_8 drop out at times; at 09:45, without PA_8, PA2_2 jumps again on corr_x, just at the edge of the noise, for the time of one measurement. The rest of the day, the corrected curves are agitated but stay within their noise; the passages of 09:30 and 12:00 are apart. The measurements stop at 12:30. Cause: the low sun at sunrise and the daylight on the scene, which make the reference spots hard to find, as on the other mornings of this station; the images show the scene in full daylight. The jumps come from the change of references, not from the structure: points not to be trusted at sunrise.", "review": "2026-11-18"}
{"start": "2026-10-09T11:45Z", "end": "2026-10-09T12:15Z", "family": "Obstruction", "description": "Bright vehicle reflections appear near PA3_2 and PB4 (12:00 thumbnails, absent at 11:45): having stayed under the threshold, they lock onto them and their corr_x, corr_y make a huge jump for the time of one measurement; the reference R2 is set aside. Everything comes back at the next measurement. The structure is not moving: these points are false, to ignore.", "review": "2026-11-17"}
{"start": "2026-10-09T12:30Z", "end": "2026-10-15T08:00Z", "family": "No data", "description": "No measurement for any sensor for nearly six days. Until the early morning of 13/10, the station is mute: no metrics and no images, although the battery was not low just before (metrics of 09/10 at noon), so this is not the outage of each night. From 13/10, the metrics come back, the battery full and stable at night, and daytime images arrive every hour, but still no displacement measurement. Cause not established (station stopped, then measurement that does not restart; an intervention is possible). The curves are missing: to be checked with the operator.", "review": "2026-11-17"}
{"start": "2026-10-15T07:45Z", "end": "2026-10-15T08:15Z", "family": "Obstruction", "description": "A single measurement, in the middle of the outage, at 08:00: five of the six references are rejected (PA1_2, PA_8, PB3_2, R2, R3); R1 alone is kept, so the compensation can only remove a translation and the camera is not properly recalibrated. PA2_2, PA3_2, PB2_2 and PB4 are rejected; PA_9, PB1_2 and PB_5 keep a point, clearly far from their level in corr_y. Their raw positions show the whole scene shifted downward by a large step since the last measurements of 09/10: the camera moved during the outage, cause not established (an intervention is possible). The 08:00 image shows translucent blurry trails on the pavement and the road, like the passages seen on the other days. Probable cause of the rejections: a passage in front of the scene, on top of the shifted camera. With a single reference, these points are meaningless: points to ignore; the camera position is to be checked with the operator."}
{"start": "2026-10-15T07:45Z", "end": "2026-10-15T08:15Z", "family": "Obstruction", "description": "A single measurement, in the middle of the outage, at 08:00: five of the six references are rejected (PA1_2, PA_8, PB3_2, R2, R3); R1 alone is kept, so the compensation can only remove a translation and the camera is not properly recalibrated. PA2_2, PA3_2, PB2_2 and PB4 are rejected; PA_9, PB1_2 and PB_5 keep a point, clearly far from their level in corr_y. Their raw positions show the whole scene shifted downward by a large step since the last measurements of 09/10: the camera moved during the outage, cause not established (an intervention is possible). The 08:00 image shows translucent blurry trails on the pavement and the road, like the passages seen on the other days. Probable cause of the rejections: a passage in front of the scene, on top of the shifted camera. With a single reference, these points are meaningless: points to ignore; the camera position is to be checked with the operator.", "review": "2026-11-18"}