auto: CLARIDEN-12 no longer points to a thermal label that does not exist (review removed); only this line, the rest of CLARIDEN's pending re-analysis left as it is — completes de092c8, whose message already named it
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
1 parent
de092c8008
commit
de2bc4a5ab
2 files changed
+2
-2
No files matched your search
@@ -10,4 +10,4 @@
|
||||
{"start": "2026-10-05T10:30Z", "end": "2026-10-05T11:20Z", "family": "Obstruction", "description": "First measurement after the gap: the whole scene, references included, is shifted by several pixels in the image and the camera is tilted, then it returns within twenty minutes; the compensation absorbs it poorly for the duration of one measurement, and the corrected curves of many targets jump then return (D-303-C, D-302-B and PR_BG, D-306-B, D-304-B, P-299-C above all; D-303-B stays slightly shifted until 11:10). D-304-C is rejected. The 10:30 image shows a large blurred object very close to the lens, on the right, which hides D-304-C, and a worker in reflective clothing in the tunnel, at the top left: work is going on around the camera. Points to ignore; the structure does not move.", "review": "2026-11-17"}
|
||||
{"start": "2026-10-05T12:10Z", "end": "2026-10-05T12:30Z", "family": "Obstruction", "description": "For the duration of one measurement, the whole right-hand row C (D-300-C, D-301-C, D-303-C, D-304-C, P-298-C, P-299-C) and the reference D-302-C are rejected, their recognition error almost at 1; the compensation runs without D-302-C and the targets that stayed under the threshold jump then return at the next measurement (D-306-B above all vertically, D-303-B, D-304-B, P-299-B, P-301-B, D-302-B and PR_BG). No image at 12:20: the cause is not seen, but the signature is that of something passing in front of the right-hand part of the scene. Point to ignore.", "review": "2026-11-17"}
|
||||
{"start": "2026-10-06T13:00Z", "end": "2026-10-06T13:30Z", "family": "Displacement", "description": "Around 13:10 the whole scene, references included, shifts by a step vertically in the image: the camera tilt makes a step, which it keeps. The compensation absorbs it for all the targets except D-303-B, whose raw position follows only part of the shift: its vertical corrected curve drops by a step and stays low into the evening (D-303-C and D-304-C at most slightly). Ordinary recognition error. Over the following days, D-303-B keeps following the camera tilt in the same partial way (the drift labeled from the evening of the 6th; the opposite camera step of the 8th leaves it only a remainder within the noise). Cause of the camera step not established; the step of D-303-B is the remainder of the camera movement, not a movement of the structure: the camera is to be monitored."}
|
||||
{"start": "2026-10-06T18:00Z", "end": "2026-10-06T22:10Z", "family": "Visibility", "description": "For four hours, the corrected curves of the same group of targets take a step that starts and ends sharply: D-301-C horizontally above all, D-302-B and PR_BG (same prism) horizontally then vertically, D-304-B vertically, and at times P-301-B, D-303-B, D-302_A, D-301-A, D-304-C. The recognition error of the references PR-293, PR-295, PR-296 and of a few targets rises a little; the references move away from each other in the image. The camera housing temperature drops clearly over these hours. Nothing visible on the 20:00 image. View obstruction of cause not established, probably the tunnel air (colder); the curves and the recognition error return at 22:00, before the camera scale (see the thermal label of the same evening). The structure does not move: curves to ignore over the range.", "review": "2026-11-17"}
|
||||
{"start": "2026-10-06T18:00Z", "end": "2026-10-06T22:10Z", "family": "Visibility", "description": "For four hours, the corrected curves of the same group of targets take a step that starts and ends sharply: D-301-C horizontally above all, D-302-B and PR_BG (same prism) horizontally then vertically, D-304-B vertically, and at times P-301-B, D-303-B, D-302_A, D-301-A, D-304-C. The recognition error of the references PR-293, PR-295, PR-296 and of a few targets rises a little; the references move away from each other in the image. The camera housing temperature drops clearly over these hours. Nothing visible on the 20:00 image. View obstruction of cause not established, probably the tunnel air (colder); the curves and the recognition error return at 22:00, before the camera scale. The structure does not move: curves to ignore over the range."}
|
||||