1.1 KiB
1.1 KiB
Request
As received (Support tab, aimsight-app):
Station: data/NADELHORN/. Range: 2026-11-18T05:39Z → 2026-11-18T11:16Z (UTC). Output folder: /home/maxime/aimsight-app/labeling/auto/support/NADELHORN_2026-11-18T0539_2026-11-18T1116/. INSTRUCTIONS: /home/maxime/aimsight-app/instructions/support.md.
Question: Prépare moi un mail simple qui diagnostique cette plage. Le client a reçu deux alarmes m_c7_mon vertical_shift et m_c10_mon vertical_shift
Prépare donc le message avec 1 ou 2 images pour visualiser le problème
Reading
- Who asks: the expert (control station), for a client of NADELHORN.
- What is wanted: a simple mail to the client (French) diagnosing the range, with 1 or 2 images.
- Station: NADELHORN.
- Range: 2026-11-18T05:39Z → 11:16Z (UTC), selected by the expert in the Data page.
- Context: the client received two "vertical shift" alarms, on targets m_c7_mon and m_c10_mon.
- Question: what caused the vertical shift alarms on m_c7_mon and m_c10_mon in this range: a real movement or a measurement artefact?
- No labels nor analyses exist on this range: the analyst reads it.