{"start": "2026-10-23T20:00Z", "end": "2026-10-25T04:00Z", "family": "Thermal displacement", "description": "Cool day of 24 October for the camera housing: its temperature drops from the evening of the 23rd, stays low all through the 24th and rises again at the 00:00 measurement of the 25th. The camera nods forward, its pan moves away and its scale drops from the 00:00 measurement of the 24th, most at 04:00 and through the day, then everything returns at the 04:00 measurement of the 25th; the raw positions of all the targets slide together in the image and come back, the targets do not move relative to each other, while the two remaining references REFH22 and REFP''21 do not follow this movement exactly. Through the compensation on these two references, the corr_y of COLJ23, COLJ24, POUH21 and COLH19 goes down a little at 00:00 and 04:00, COLH19 and POUJ20 again at 12:00, and comes back in the evening; the corr_x of COLH19, POUH21 and COLJ24 is a little higher during the day and partly comes back on the 25th, under the long upward drift labelled apart. The error_value rises only a little, on COLH19 and COLH20; spots unchanged on the 04:00 and 16:00 thumbnails, nothing in front of the targets on the 04:00 image. According to the expert, BREITHORN, MICHIGAN and NEBRASKA are in the same building: the cameras of BREITHORN and MICHIGAN move the same day, with the same cooling. Deduced from the curves, the pose and the temperatures: a camera movement with the cold, poorly compensated by the two-reference basis. Not a movement of the structure: nothing to do, do not trust these points."}
{"start": "2026-10-26T00:00Z", "end": "2026-10-26T20:00Z", "family": "Thermal displacement", "description": "Cool morning of 26 October: from 04:00 to 16:00, the corr_y of the top targets rises (POUJ19, COLJ20, COLJ19, POUJ20 above all), then returns in the evening; the corr_x hardly moves. The camera nods forward and rotates at the same moment, at the trough of the camera housing temperature, read in the metrics, then partly returns. Nothing in front of the targets on the 08:00 image. According to the expert, BREITHORN, MICHIGAN and NEBRASKA are in the same building: the cameras of BREITHORN and MICHIGAN move the same morning, at the same cooling. Deduced from the curves, the pose and the temperatures: a brief camera movement with the cold, poorly compensated by the two-reference basis. The targets do not move: nothing to do, do not trust these points.", "review": "2026-11-17"}
{"start": "2026-10-27T20:00Z", "end": "2026-10-28T16:00Z", "family": "Thermal displacement", "description": "Cool morning of 28 October: from midnight to noon, the corr_y of most targets goes down (COLH19, POUH19, POUJ20, COLJ20, COLH20 above all), then returns in the afternoon; the corr_x of almost all the targets makes a peak at the 08:00 measurement (COLJ19, COLJ20, POUJ19, POUH20, POUH21). The camera moves at the same time, at the coldest hour of the morning for its housing: its pan and rotation move away at 04:00, it nods forward and its scale drops at 08:00, then everything returns at noon; no reference poorly seen, nothing on the images. Deduced from the curves, the pose and the temperatures: a brief camera movement with the cold, poorly compensated by the two-reference basis. The targets do not move: nothing to do, do not trust these points.", "review": "2026-11-17"}
{"start": "2026-10-28T20:00Z", "end": "2026-10-29T12:00Z", "family": "Thermal displacement", "description": "Coldest night of the month for the camera housing, from 28 to 29 October: from midnight to morning, the camera nods forward, its pan, rotation and scale move away, most at 04:00, then everything returns at noon. The corr_x of almost all the targets rises over these measurements, peaking at 04:00; the corr_y of most jumps upward at 04:00 (COLJ20, POUJ19, COLH19, POUH19, COLH20 above all), framed by lower measurements at 00:00 and 08:00. At 04:00, the two remaining references move slightly relative to each other in the image, which the two-reference basis translates into a rotation of the whole scene; the error_value of REFH22, COLH19 and COLH20 also rises, far from the threshold, without rejection. Thumbnails of REFH22, REFP''21 and COLH20 with nothing clear, spots unchanged. Deduced from the curves, the pose and the temperatures: thermal effect on the camera; the cause of the rise in error_value is not established. Not a movement of the structure: nothing to do, do not trust the curves over these measurements.", "review": "2026-11-17"}
{"start": "2026-10-29T20:00Z", "end": "2026-10-30T16:00Z", "family": "Thermal displacement", "description": "Same thing on the following cold night, from 29 to 30 October: the camera nods forward, its rotation and scale move away, most at 04:00, then return in the afternoon. The corr_x of the targets is higher from midnight to noon; the corr_y of most jumps upward at 04:00 (COLJ20, POUJ19, POUH20, POUJ20 above all), then downward at 08:00. The error_value of REFH22 and COLH20 rises to its highest of the month at 04:00, that of COLH19 too, far from the threshold, without rejection. 04:00 thumbnails with nothing clear, spots unchanged. Deduced from the curves, the pose and the temperatures: thermal effect on the camera, poorly compensated by the two-reference basis; the cause of the rise in error_value is not established. Not a movement: do not trust the curves over these measurements.", "review": "2026-11-17"}
{"start": "2026-10-31T00:00Z", "end": "2026-10-31T16:00Z", "family": "Thermal displacement", "description": "Slight cooling of the camera housing on 31 October, lowest from the end of the night to late morning, then rising again in the afternoon. The camera nods forward a little, its pan moves away and its scale drops at the 04:00 and 08:00 measurements, then everything returns at 16:00; the raw positions of all the targets slide a little together, the targets do not move relative to each other, while the reference REFH22 moves slightly upward relative to them. Through the compensation on the two remaining references, the corr_y of most targets goes down together at 04:00 (COLJ20, POUJ20, COLH19, POUJ19, POUH19 above all), stays low at 08:00 and 12:00 and returns at 16:00; the corr_x of COLH19, COLJ23 and POUH20 rises a little at 04:00. The error_value stays at its level; spots unchanged on the 00:00, 04:00 and 08:00 thumbnails; on the 08:00 image, lights are on in the background below the targets, away from the spots. Same signature as the cold nights of 28 to 30 October, weaker; according to the expert, MICHIGAN is in the same building, and its curves drop the same day. Deduced from the curves, the pose and the temperatures: a camera movement with the cold, poorly compensated by the two-reference basis. Not a movement of the structure: nothing to do, do not trust these points."}
{"start": "2026-10-31T20:00Z", "end": "2026-11-01T00:00Z", "family": "Thermal displacement", "description": "Start of a new cooling of the camera housing at the end of the range: at the 00:00 measurement of 1 November, the camera nods forward, its pan moves away and its scale drops, and the corr_y of most targets goes down together (POUH21, COLH21, POUH19, POUJ20, COLJ20 above all); the corr_x hardly moves. The movement goes on after this measurement, which ends the range: the label is to be extended with the following range. The error_value stays at its level; nothing in front of the targets on the 00:00 image. Deduced from the curves, the pose and the temperatures: a camera movement with the cold, poorly compensated by the two-reference basis, like the cold nights at the end of October. Not a movement of the structure: nothing to do, do not trust these points."}