NORDEND: a morning of thermal cycle, and a camera jolt at noon
The selection runs from 05/11 06:00 to 05/11 12:00 (UTC), without hints. The question: what do the corrected curves show over this morning, and what is not yet labeled?
What the data show
- 06:30 → noon (and until the next day): the thermal cycle of the camera. Already labeled (NORDEND-234).
- The housing heats from about 19 °C to 28 °C. The camera turns: the pan drops, the tilt rises, the scale increases.
- The whole scene, references included, slides together in the image. The compensation almost absorbs it: a drift of a few hundredths of a px remains on the targets of the right edge (PR18, PR16, PR15, PR13 in
corr_x) and on PR04 and PR08. - Cause: strongly supported. The pose follows the housing temperature, and the rock face does not move with the temperature.
- Commands:
overview.py data/NORDEND --start 2026-11-05T04:00Z --end 2026-11-05T14:00Z --min 1;metrics.pyon the same window.
- 12:00, one measurement: a camera jolt that the compensation does not erase. New label, Displacement.
- The rotation and the tilt jump then come back at 12:15. The raw positions of all sensors, references included, jump together then come back.
- The
corr_yof PR01, PR10, PR02, PR04 and PR07 drops clearly, by 5 to 7 times their noise. Thecorr_xof PR01 and PR02 rises a little. Everything comes back at 12:15. - What does not move: no reference lost, no rejection outside CTR01 (as usual), nothing in front of the targets on the image of 12:00.
- Cause: a jolt of the camera or its mount, consistent with the pose; not seen, therefore not established.
- Commands:
ranges.py data/NORDEND --start 2026-11-05T04:00Z --end 2026-11-05T14:00Z --columns corr_x,corr_y --rolling 4 --instants 3(8 sensors off level at 12:00 only);overview.py ... --rigid 2026-11-05T06:00Z.
- The missing points: all already labeled.
- CTR01 is rejected over almost the whole range: Target issue, NORDEND-230.
- PR09 is rejected at times until 09:30: thread of the spider web seen at night, NORDEND-232.
- Command:
inventory.py data/NORDEND --start 2026-11-05T06:00Z --end 2026-11-05T12:00Z.
- 09:45, one measurement: PR09, PR10 and PR12 drop a little in
corr_y, then come back.- It is the moment when the thermal drift goes fastest, without a pose jolt.
- I leave it in the thermal cycle, whose label already cites it.
The corr_y of PR01, PR02, PR04, PR07 and PR10 dips at 12:00 (grey zone) and comes back at 12:15. The small dip of 09:45 is also visible, weaker.
At the top, the pose drifts all morning with the heat (thermal cycle). At 12:00, the rotation, the tilt and the raw position of all sensors make a one-measurement peak, then come back.
Sunny day. The targets are in the shade, at the bottom right, and nothing is in front of them.
The slow drift of the right edge (PR18, PR16, PR15, PR13) over the morning: it is the rest of the thermal cycle.
What remains not established
- The cause of the jolt of 12:00: a brief movement of the camera or its mount, without an image of the instant that shows it. A second jolt of the same shape follows at 12:30, outside the selection and not read.
- The end of NORDEND-232 (PR09) is perhaps one step too early: PR09 is still a little low at 10:00.
- The back-and-forth of the
error_valueof CTR02, PR01 and PR09 all morning, without effect on the curves, remains unexplained.
Labels
- 05/11 11:45 → 12:15, Displacement: one-measurement jolt of the camera at 12:00, several targets drop in
corr_yand come back; not a movement of the structure, points to ignore, camera to monitor if it repeats. - Kept as they are: NORDEND-229, NORDEND-234 (Thermal displacement), NORDEND-230 (Target issue, CTR01), NORDEND-232 (Obstruction, PR09).